DC MOTOR ANALYSIS & TROUBLESHOOTING



Similar documents
Tuning Up DC Motors and Generators for Commutation and Performance

The DC Motor/Generator Commutation Mystery. Commutation and Brushes. DC Machine Basics

(3) Explosion proof. Designed to prevent ignition of any explosive gases or dust and dirt which may surround the motor.

Lab 8: DC generators: shunt, series, and compounded.

SYNCHRONOUS MACHINE TESTING WITH MOTOR CIRCUIT ANALYSIS INSTRUMENTATION

BRUSHHOLDERS AND THE PERFORMANCE OF CARBON BRUSHES

DIRECT CURRENT GENERATORS

Motor Fundamentals. DC Motor

DC GENERATOR THEORY. LIST the three conditions necessary to induce a voltage into a conductor.

1. The diagram below represents magnetic lines of force within a region of space.

Motors and Generators

Direct Current Motors

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

The Effect. Spring Pressure. Carbon Brush Wear Rate

The Charging System. Section 5. Charging System. Charging System. The charging system has two essential functions:

Preventive Maintenance. State Energy Assessment Workshop By: DTE Energy Partnership & Services

Single-Phase AC Synchronous Generator

Equipment: Power Supply, DAI, Wound rotor induction motor (8231), Electrodynamometer (8960), timing belt.

Windshield Wiper Motors

Odyssey of the Mind Technology Fair. Simple Electronics

Principles and Working of DC and AC machines

GOVERNMENT COLLEGE OF ENGINEERING, BARGUR

13 ELECTRIC MOTORS Basic Relations

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

UNIT 3 AUTOMOBILE ELECTRICAL SYSTEMS

Single and Three Phase Transformer Testing Using Static Motor Circuit Analysis Techniques

Evaluating Induction Motor Rotor Bars with Electrical Signature Analysis

AC generator theory. Resources and methods for learning about these subjects (list a few here, in preparation for your research):

Heavy Duty Alternator Charging System Troubleshooting

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS

COATING & WRAPPING OF UNDERGROUND PIPING

Static Drives vs Motor Generators

AC-Synchronous Generator

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Equipment: Power Supply, DAI, Universal motor (8254), Electrodynamometer (8960), timing belt.

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

Induction Motor Theory

Line Reactors and AC Drives

Load Cell Troubleshooting

DC generator theory. Resources and methods for learning about these subjects (list a few here, in preparation for your research):

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

Inductance. Motors. Generators

Understanding the Alternator

GUIDE TO THE MAINTENANCE, INSPECTION AND TESTING OF PORTABLE EQUIPMENT (ELECTRICAL APPLIANCES AND TOOLS) IN THE WORKPLACE

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

Pump Maintenance - Repair

12 Volt 30 Amp Digital Solar Charge Controller

The Starting System. Section 4. Starting System Overview. Starter. The starting system:

Rutland 913 Windcharger Fault Finding Guide

NEMA Magnet Wire Thermal Class Ratings

Understanding Insulation Resistance Testing

SALVAGING FLOOD DAMAGED ELECTRICAL EQUIPMENT

Chapter 22: Electric motors and electromagnetic induction

6/14/02 Chapter 14: Use of Electrical Test Equipment 1/20

ELECTRICAL FUNDAMENTALS

Federal Wage System Job Grading Standard for Electrical Equipment Repairing, Table of Contents

INSTALLATION and OPERATION RANGE BALL CONVEYOR MODEL NO: BC-001AN

Table Z. Troubleshooting Chart for Air Conditioners. Cause

Prof. Krishna Vasudevan, Prof. G. Sridhara Rao, Prof. P. Sasidhara Rao. x x. x x. Figure 10: Cross sectional view

Students will investigate the characteristics of electromagnetism and then use what they learn to plan and conduct an experiment on electromagnets.

ELECTRICAL SAFETY RISK ASSESSMENT

Lab 14: 3-phase alternator.

Basic Load Tap Changer Operation

Chapter 7 Hydraulic System Troubleshooting

COMPUTER AIDED ELECTRICAL DRAWING (CAED) 10EE65

Basics of Electricity

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

Diagnosing and Understanding Starting Problems on the ZR-1 Marc Haibeck 28-Sep-13

. Failure. Analysis... Report...

IA Renewal Seminar 2014

THE LUCAS C40 DYNAMO & ITS ARMATURE.

Rotating Machinery Diagnostics & Instrumentation Solutions for Maintenance That Matters

Synchronous motor. Type. Non-excited motors

ELECTRODYNAMICS 05 AUGUST 2014

Power-factor testing of rotating machinery is another valuable test

Georgia Performance Standards Framework for Physical Science 8 th Grade. Powering Satellites

Federal Wage System Job Grading Standard for Powered Support Systems Mechanic, Table of Contents

HYDRAULIC LIFT TABLE CART 2200-LB.

This chapter is devided into two sections:

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

PS-6.2 Explain the factors that determine potential and kinetic energy and the transformation of one to the other.

The Simple DC Motor: A Teacher s Guide

Application Information

Electrical Domestic Appliances (EDA)

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

AC Generators and Motors

TROUBLESHOOTING PRELIMINARY

ELECTRICAL CIRCUITS. Electrical Circuits

Checking Wheel Brakes Wear

Trouble Shooting. Pump

16. APTA PR-IM-S Standard for Pantograph Current Collection Equipment Periodic Inspection and Maintenance

STUDY GUIDE: ELECTRICITY AND MAGNETISM

Lab 37: Magnetic Field ; Magnets - Drawing magnetic fields - Magnetic poles - Forces between magnets

Installation, Operating and Maintenance Instructions for AEON Metal Seated Gate Valve (MSGV) Water

SYNCHRONOUS MACHINES

AC Electric Motors best practice

PARTS LIST (G-2536GP) (Automotive Start Unit )

The DC Motor. Physics 1051 Laboratory #5 The DC Motor

Diesel Engine starting Systems

BUILDING A BASIC CIRCUIT

Transcription:

DC MOTOR ANALYSIS & TROUBLESHOOTING By Don Shaw Condition assessment of DC motors requires a basic understanding of the design and operating characteristics of the various types available: the series motor, the shunt motor, and the compound motor. Each type has unique operating characteristics and applications. These characteristics enable the operator to perform a wide variety of tasks. DC motor fault zone analysis is a vital part of any DC motor maintenance program. Visual inspection and electrical testing of the armature and fields give the maintenance personnel an understanding of the condition of the motor. Implementing a predictive maintenance program takes a PM program to the next level. We will review some case studies that will illustrate the utilization of an effective predictive program. Series DC Motor Components of a series motor include the armature, labeled A1 and A2, and the field, S1 and S2. The same current is impressed upon the armature and the series field. The coils in the series field are made of a few turns of large gauge wire, to facilitate large current flow. This provides high starting torque, approximately 2 ¼ times the rated load torque. Series motor armatures are usually lap wound. Lap windings are good for high current, low voltage applications because they have additional parallel paths for current flow. Series motors have very poor speed control, running slowly with heavy loads and quickly with light loads. A series motor should never drive machines with a belt. If the belt breaks, the load would be removed and cause the motor to overspeed and destroy itself in a matter of seconds. Common uses of the series motor include crane hoists, where large heavy loads will be raised and lowered and bridge and trolley drives on large overhead cranes. The series motor provides the starting torque required for moving large loads. Traction motors used to drive trains are series motors that provide the required torque and horsepower to get massive amounts of weight moving. On the coldest days of winter the series motor that starts your car overcomes the extreme cold temperatures and thick lubricant to get your car going. Shunt DC Motor The shunt motor is probably the most common dc motor used in industry today. Components of the shunt motor are the armature, labeled A1 and A2, and the field, labeled F1 and F2. The coils in the shunt field are composed of many turns of small wire, resulting in low shunt field current and moderate armature current. This motor provides starting torque that varies with the load applied

and good speed regulation by controlling the shunt field voltage. If the shunt motor loses it s field it will accelerate slightly until CEMF rises to a value sufficient to shut off the torque producing current. In other words, the shunt motor will not destroy itself if it loses its field, but it won t have the torque required to do the job it was designed for. Some of the common uses of the shunt motor are machine shop lathes, and industry process lines where speed and tension control are critical. Compound DC Motor When comparing the advantages of the series and shunt motors, the series motor has greater torque capabilities while the shunt motor has more constant and controllable speed over various loads. These two desirable characteristics can be found in the same motor by placing both a series field and shunt field winding on the same pole. Thus, we have the compound motor. The compound motor responds better to heavy load changes than a shunt motor because of the increased current through the series field coils. This boosts the field strength, providing added torque and speed. If a shunt coil is added to a series motor at light loads (when a series motor tends to overspeed) the added shunt field flux limits the top speed, eliminating self-destruction.

Common uses of the compound motor include elevators, air compressors, conveyors, presses and shears. Compound motors can be operated as shunt motors by disconnecting the series field. Many manufacturing process lines are designed this way. The reason being that, most off the shelf motors are compound motors, and the series field can always be connected later to provide additional torque, if needed. Compound motors can be connected two ways, cumulatively and differentially. When connected cumulatively, the series field is connected to aid the shunt field, providing faster response than a straight shunt motor. When connected differentially, the series field opposes the shunt field. Differentially connected compound motors are sometimes referred to as suicide motors, because of their penchant for self-destruction. If perhaps, the shunt field circuit were to suddenly open during loading, the series field would then assume control and the polarity of all fields would reverse. This results in the motor stopping, and then restarting in the opposite direction. It then operates as an unloaded series motor and will destroy itself. Differentially connected motors can also start in the opposite direction if the load is too heavy. Therefore, it is seldom used in industry. Fault Zone Preventative Maintenance Fault zone preventative maintenance on dc motors includes electrical testing and visual inspection of the armature, commutator, brushes and fields. Over the years, people have been performing insulation to ground tests on DC equipment to evaluate the condition of insulation, particularly with regard to moisture and dirt. These parameters are valuable readings when taken under similar conditions at various times. High insulation resistance values do not necessarily indicate high dielectric strength. Insulation that is mechanically damaged may show high resistance values but fail at relatively low dielectric test voltages. Insulation resistance varies inversely to the temperature of the motor. As the temperature increases, resistance will decrease. Approximately 8 to 15 C temperature rise will half the resistance. Checking brushes and commutator condition are very important parts of an effective PM program. The brush face condition can provide valuable insight into the motor operation. The commutator surface condition can also indicate how the motor is reacting to various load and atmosphere conditions.

Armature Visual inspection of the armature should include the search for cracked or brittle insulation, loose or broken banding, and any dirt or oil contamination. Leakage to ground testing of the armature indicates the relative condition of the insulation. Performing a bar-to-bar resistance check will indicate any shorted windings or defective solder joints at the risers. Infrared inspection of the armature can reveal overheating of the brushes, commutator, as well as loose or hot connections on the risers. The ideal temperature for proper commutation is between 120-140 F. Figure below shows a typical leakage to ground profile graph Fields Visual inspection of the field coils will reveal cracked or brittle insulation. Leakage to ground testing provides a general assessment of the insulation condition. The most common method used to check for shorted windings is to perform a drop test. In this test an ac voltage, normally 110 volts, is applied to the field leads. The voltage drop across each field pole is measured with a voltmeter. In a healthy motor, all voltage drops should be equal. Commutator Commutator film is developed by the chemical reaction that takes place between the copper surface of the commutator, the graphite surface of the brush and the air surrounding both. This film is very delicate and any variation in load or atmosphere can destroy it. Where poor commutation is present excessive physical wear will result on both the commutator and the brushes. The following pages indicate common conditions that contribute to poor commutation.

High Mica: Mica is the insulation material used between each segment in a commutator. The mica is approximately 1/16 lower than the adjacent commutator bars. If the commutator bars are worn or if the mica becomes loose and extends higher than the commutator bars the result will be brush chatter. Putting the dumb end of a lead pencil, or other insulated device, on a brush while the motor is rotating and feeling for vibration can identify this. High Commutator Bars: This condition is usually caused by the wedge or wedge ring that hold the bars in place coming loose. Normally you can hear the brush chatter caused by this condition or you can use the pencil method described above. DC motors have definite applications in today s industry. Each type offers specific characteristics and strengths, depending on the task at hand. Because they are expensive to replace and repair, proper maintenance is a necessity. Utilizing fault zone analysis should be an integral part of any DC predictive maintenance program. Utilizing both electrical testing and visual inspection of the armature, commutator, brushes and fields will ensure a thorough understanding of overall motor condition, giving you the knowledge necessary to keep these motors operating.