Operating instructions Switching amplifier for fibre optics. OBF5xx 704876 / 00 08 / 2010



Similar documents
Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

Operating instructions Optical distance sensor O1D100 O1D / / 2012

Operating instructions Capacitive sensors

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Operating instructions. AS-i Profibus gateway AC1411 / AC /00 04/2014

Operating instructions. Monitor FR-1 / FR-1N / / 2011

Operating instructions Mechatronic flow sensor. SBY33x /06 03/2011

Color Mark Sensor with Red or Green LED E3S-VS

BOS 73K... BOS 74K...

DALI RC BASIC SO. Control unit Operating instructions

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems

Drayton Digistat +2RF/+3RF

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Fiber-Optic Photoelectric Sensor

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

POINTS POSITION INDICATOR PPI4

Points Position Indicator (PPI1) for Points Motors with Common Ground

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Digital input modules

WD-AMX Water Detection Controllers

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Smart Sensing Solutions Since 1954

Universal Voltage Terminal Photoelectric E3JM

Electrical connection

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

E3Z. Ordering Information. Photoelectric Sensor with Built-in Amplifier. Compact Sensor Offers Long Sensing Distance and Superior Noise-Immunity

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Miniature High-Resolution Registration Mark Sensor White LED AUTOSET Remote Setup Option

AUTODIALLER / QUICKDIALLER - SA132

INSTALLATION MANUAL VEHICLE SECURITY SYSTEM CE-SS200

MULTI-BEAM LS10 Light Screen System

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

COMPALARM AP GENERAL MAIN FEATURES

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation!

PUSH BUTTON START INSTALLATION MANUAL

Adjustment functions for both span and shift have been incorporated

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Control Box Wiring For PRSstandard Tool


Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

IO-DIM6 6-Channel, Digital to Analogue Converters

Thru-Beam 80 to 320 mm 0.05 to 0.08 mm

T0118 T2118 T3118. Instruction Manual

Contents. Document information

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

IO-RM3 3-Stage Relay Module

Inwall 4 Input / 4 Output Module

instabus KNX / EIB System System E F G H

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

INSTALLATION MANUAL XM3 Reader

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

How To Control A Car Alarm On A Car With A Remote Control System

Installation instructions CAN/RS232-USB interface CANfox EC / / 2010

Lighting Controls ! WARNING RISK OF ELECTRIC SHOCK. Installation Instructions DESCRIPTION

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Sensing method Appearance a Connection o method Sensing distance Model NPN output PNP output Through-beam Pre-wired (see note 3) Connector.

intelligent solutions


technical data (according to IEC )

ANTI-THEFT SYSTEM Volvo 850 DESCRIPTION & OPERATION BASIC ALARM ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems

GEARBOX MONITOR MODEL NR USER MANUAL

Power Socket (2 Gang)

Cross-beam scanning system to detect slim objects. 100 mm in

Installation & User Manual Radio Remote rev1.0.3

MOUNTING AND OPERATING INSTRUCTIONS

Electric Landing Gear controllers and sequencer LGC12 / LGC 13C

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Electronic Pressure Switch EDS 300

BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS

sensors Miniature Sensors - S100 The universal miniature photoelectric sensor

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

W150: Miniature photoelectric switch series with completely integrated electronics

R55F Series Fiber-Optic Color Mark Sensors

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

photoelectric highlights

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Mini Breakout-Board. CNC Interface for LPT Port. Installation Manual Version 4

Operating Manual UMB Analogue/Digital Converter ANACON Order Number: 8160.UANA

SLIM LINE FUME HOOD MONITOR

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

DMG 970. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners

Product and functional description

Operating instructions Electronic pressure sensor. PF265x /00 06/2011

LUT Luminescence scanners: Seeing what no-one else can

ASSEMBLY MANUAL SE-4S35

INSTALLATION GUIDE. FCC ID NOTICE

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

QUICK REFERENCE MANUAL

Talon and Talon SR User Manual

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

PRO PLM Installation Instructions

Transcription:

Operating instructions Switching amplifier for fibre optics OBF5xx 70876 / 00 08 / 00

Contents Preliminary note. Symbols used Functions and features. Applications Installation. Attaching the fibre optics Electrical connection 5 5 Operating and display elements 6 6 Settings 7 6. Automatic setting of the sensitivity 7 6.. The sensor is to switch when the object is detected 7 6.. The sensor is not to switch when the object is detected 8 6.. Measured value difference too small 8 6. Manual setting of the sensitivity 8 6. Setting of maximum sensitivity 9 6. Setting of the pulse stretching 0 6.5 Electronic lock 7 Operation 7. Set-up 7. Fault indications 8 Maintenance, repair, disposal

Preliminary note. Symbols used Instruction > Reaction, result [ ] Designation of pushbuttons, buttons or indications Cross-reference Important note Non-compliance can result in malfunctions or interference. Information Supplementary note. Functions and features The switching amplifier detects objects and materials without contact and indicates their presence by a switching signal.. Applications Only for use with ifm fibre optics type FE-50 and FT-50. The range is determined by the fibre optics. Pulse stretching, adjustable 0 or... 90 ms. Each input pulse is stretched to the set value. Installation Hook the unit into the DIN rail () and clip it into place () or fix it by means of a mounting fixture. Removal Lever out the mounting clip (A) with a screwdriver () and remove the unit. A

. Attaching the fibre optics Loosen the screw (A). Push the fibre optics into the sensor holes (B) until the end stop and hold them. A B Tighten the screw (A). A If the fibre optics are not in contact with the internal optics, the sensing range is reduced.

Electrical connection The unit must be connected by a qualified electrician. The national and international regulations for the installation of electrical equipment must be adhered to. Voltage supply according to EN 5078, SELV, PELV. Disconnect power. Connect the unit as follows: Automatic PNP / NPN detection M8 M8 M Cable L+ L L+ L BN BK VT BU L+ L L+ L L+ L BN VT BK BU L+ L Core colours: BN (brown), BU (blue), BK (black), VT (violet). On power up, the unit detects automatically if the switching output is connected to L- (= PNP) or to L+ (= NPN). The polarity of the function check output is set according to the polarity of the switching output. Both outputs must be connected with the same polarity: PNP or NPN! 5

5 Operating and display elements : Row of LEDs ( x LED green x LED red) Excess gain in % Input signal strength Pulse stretching in ms : Programming button [OUT on] Automatic setting "OUT on" Manual setting "+" Pulse stretching "+" : LED yellow Switching status LED green Operating status 5: Programming button [OUT off] Automatic setting "OUT off" Manual setting "-" Pulse stretching "-" 5 6

6 Settings 6. Automatic setting of the sensitivity 6.. The sensor is to switch when the object is detected Diffuse reflection optics (FT-50) Position the object. Press [OUT on] for > s to < 6 s. > > The sensitivity is set to the object. > > The green LED lights, the yellow LED flashes x. Remove the object. Press [OUT off]. > > The sensitivity is set without object. > > The green LED lights, the yellow LED indicates the switching status. > > The programming is finished. Through-beam optics (FE-50) Position the object. transmitter Press [OUT on] for > s to < 6 s. > > The sensitivity is set to the object. > > The green LED lights, the yellow LED flashes x. receiver 7

Remove the object. transmitter Press [OUT off]. > > The sensitivity is set without object. > > The green LED lights, the yellow LED indicates the switching status. > > The programming is finished. receiver 6.. The sensor is not to switch when the object is detected Position the object (see figure ) and press [OUT off]. Remove the object (see figure ) and press [OUT on]. The settings can also be carried out first without object (step ) and then with object (step ). Timeout If no button is pressed for 5 min during the setting procedure, the unit changes to the normal operating mode with unchanged values. 6.. Measured value difference too small If the measured value difference is too small, the switching threshold can be manually adjusted. > > The unit changes to the manual setting mode. 7. Manual setting of the sensitivity / step. 6. Manual setting of the sensitivity Carry out the automatic setting prior to the manual setting to determine the light-on / dark-on mode. Diffuse reflection optics (FT-50) / through-beam optics (FE-50) Press [OUT off] for > 6 s to < 0 s. out on % 00 00 50 00 50 > > The green LED flashes with Hz, the yellow LED indicates the switching status. > > The row of LEDs indicates the input signal strength and flashes to indicate the switching threshold. 8

Modify the switching threshold Press [OUT off] to reduce the switching threshold. Press [OUT on] to increase the switching threshold. --Fast forward by keeping the button pressed. out on % 00 00 50 00 50 Exit setting Press [OUT on] + [OUT off] simultaneously. > > The unit changes to the normal operating mode. Check the safe switching function. If necessary, repeat the setting ( step ). Timeout If no button is pressed for 5 min during the setting procedure, the unit changes to the normal operating mode with unchanged values. 6. Setting of maximum sensitivity Align the fibre optics so that no light is received. The sensor is to switch when light is received First press [OUT on], then [OUT off]. The sensor is to switch when no light is received First press [OUT off], then [OUT on]. 9

6. Setting of the pulse stretching The length of the output signal can be adjusted. If the object does not stay in the detection zone long enough, it is possible to stretch the pulse time. Press [OUT on] for > 6 s to < 0 s. > > The green LED flashes with Hz, the yellow LED indicates the switching status. > > The row of LEDs indicates the pulse stretching. Set the pulse stretching time. Press [OUT off] to reduce the pulse stretching time. Press [OUT on] to increase the pulse stretching time. -- push on the button corresponds to ms. --Fast forward by keeping the button pressed. Exit setting Press [OUT on] + [OUT off] simultaneously. > > The unit changes to the normal operating mode. 0-0 - 0-0 - 0-50 5-60 6-70 7-80 8-90 time (ms) 90 70 50 0 0 lighting LEDs 0

Timeout If no button is pressed for 5 min during the setting procedure, the unit changes to the normal operating mode. 6.5 Electronic lock The unit can be locked electronically to prevent unauthorised setting. On delivery the unit is not locked. Locking / unlocking Press [OUT on] and [OUT off] simultaneously for 0 s. > > Acknowledgement is indicated by a change of the status of the yellow LED. > > The unit is locked. To unlock repeat this step. 7 Operation 7. Set-up After installation, electrical connection and parameter setting, check whether the unit operates correctly. > > Display by LEDs. The red LED lights and the output FC "function check output" is switched in case of a detection problem (insufficient object recognition, maladjustment, soiling of the lens). After rectification of the fault and several successful switching operations, the function check output is automatically switched off.

7. Fault indications Display Cause out on % 00 00 50 00 50 LED yellow flashes at Hz. LED green is off. Row of LEDs is off. Internal fault out on % 00 00 50 00 50 LED yellow flashes at 8 Hz. Green LED is lit. Row of LEDs is off. Timeout: Max. Programming time of 5 min. exceeded. Change to the normal operating mode. 8 Maintenance, repair, disposal Faulty sensors must only be repaired by the manufacturer. After use dispose of the unit in an environmentally friendly way in accordance with the applicable national regulations. Technical data and further information at www.ifm.com