Motor suppressors. Standardized motor suppression from Murrelektronik



Similar documents
pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

48 SERIES Relay interface modules 10 A

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

49 Series - Relay interface modules A. Features

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Cable Plug acc. to DIN EN , Form A

Shunt lock function 3066

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

Product and functional description

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

HARTING Ethernet Cabling 4-poles Overview

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

BETA Protecting SITOR Semiconductor Fuses

mpm DIN CONNECTORS

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Reaction Torque Sensor

14 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN

Product Information Sheet UH28CS-12kV Hi Pot Tester

High Power Connectors for Power Supply and Power Circuits

Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules

KNX Interface. User Manual PM00A00IRI

Proximity Switches RS (Reed Switch)

Safety automation solutions

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

38 Series - Relay interface modules A

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

connecdim Gateway G1 Ethernet TCP/IP to DALI

New XUY roller sensors

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

HARTING mcon 3000 Introduction and features

Electric Rotary Actuator - On/Off or programmable control actuator

CONFIGURABLE SAFETY RELAYS

Operating Instructions Drill rig DRU160

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

RY2 miniature industrial relays

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

type V46, solenoid or pneumatic operated

HERZ-Thermal Actuators

IBS IP I/O Gateway. Data Sheet INTERBUS-S. Coupling Module for Two InterBus-S Lines

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

Digital inductive conductivity transmitter

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

Page 162. Page 154. Page 158 Page 146. Page 157. Page 152. Page 160. Page 149. Page 159. Page 156. Page 150


38 Series - Relay interface modules A

RT series Miniature Printed Circuit Board Relays, Sockets and Accessories

Safety technique. Emergency stop module BO 5988 safemaster

Installation Manual (English) Adjustable Active DP Terminator T1-Pepper Active RS485 segment termination for non-compliant cable

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

LENORD. +BAUER... automates motion. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space

MasterINTERFACE 39 Series - Relay interface modules

SMS 4 / SMS 5 safety mat Product information

Pluggable interface relays CR-P Pcb relays

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Line-Mounted Valves L Series

Flextec 450 PARTS LIST FOR RETURN TO MAIN INDEX

Life Expectancy : Class A Class B Class C Class D 30,000hrs 10,000hrs 3,000hrs 1000hrs

Hose and Tube Fittings Series 1-3

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A

General Purpose Relays Accessories. Accessories Miniature Relay PT

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range Schmersal T [] C

Mini USB and USB 2.0-IP67 Connector System

Inductive Proximity Sensors

TX OPEN RS232/485 module

POWER WAVE 455M/STT & (CE)

SITRANS F flowmeters SITRANS F M

General 1-2-Opto-electronics Safety Switches 4-Emergency

Type: DILM32 10(24V50HZ) Article No.:

Quick Connect. quick - simple - efficient.

in widespread use with Simplex sister Company, Simplex Onsite, providing nationwide load bank rentals.

Redundancy Module QUINT-DIODE/40

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

HARTING Ethernet Cabling 4-poles Overview

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

TECHNICAL DATASHEET Incremental Encoder RI 58-H

Digital input modules

HARTING Ethernet Cabling 8-poles Overview

Capacitive Prox E2K-X

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

AZ420 MINIATURE GENERAL PURPOSE RELAY

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

ISO /2 (VDMA 24563) ISO 02 (18 mm) - ISO 01 (26 mm) Valves

400 Series - Mini USB Buccaneer

4/2-Way Pneumatic Solenoid Valve

Transcription:

Standardized motor suppression from Murrelektronik In the guideline EN 60204/DE 0113 para. 11.2.2 it states, that motors in PLC or NC controlled machines and systems must be fitted with a suitable suppressor. Murrelektronik offers a suitable motor suppressor for every application. he suppressor should, if at all possible be mounted very close to the source of interference (Motor). he European norm (EN) 50262 has been valid since 12/31/1999 for metric threads and replaces the DIN 460 for PG threads. In this transitional period Murrelektronik offers both variants. here are also modules available which can be snapped onto DIN-rail. he use of motor suppression equipment protects the motor from high inductive voltage spikes when switching off. At the same time, it increases the contact life span of the control unit. ith the optimum suppression modules from Murrelektronik, you receive the highest level of operational safety. he machine or control panel will function within the EMC regulations, without affecting other electrical equipment in the surrounding area. Murrelektronik offers the perfect mounting method for every application! For connection to the motor terminal box he Murrelektronik motor suppressor in the series RC3, RC3R and RC3 RG have a M16 x 1.5, M20 x 1.5, PG 9 or PG 13.5 screw thread for direct mounting on to the the terminal box of the motor. Suppression, where the interference arises! nder the contactor he motor suppressor series RC3/RC3K snap on to 35 mm DlN-rail (EN 50022). he contactor can then be snapped piggy-back style on to the suppressor. RC3S contains additional contactor suppression as well. Space savings. Direct mounting in the terminal box Our smallest motor suppressor RC3 fit snugly into the terminal box of the motor. Direct suppression on the motor. Snaps on to DIN and C-rails Murrelektronik motor suppressors can be fitted with a snap foot to allow mounting on DIN-rail. he models are in a space saving 12mm housing. RC3, RC3G Snap on, connect, finished. Mounting direct on the motor ith the RC 3 S, the motor can be quickly connected and at the same time suppressed. Suppression and connection in one. 3.5.1

on the motor terminal box inside the motor terminal box inside the distribution box on 35 mm DIN-rail to EN 50022, and C-rail RC 3 RC 3 RC 3 RC 3 G with M16 x 1.5 with PG 9 screw screw RC-suppression aristor-suppression (DR) 6-wire 1 1 1 2 2 2 Ordering data Art.-No. Art.-No. Art.-No. Art.-No. oltage Motor rating suppression suppression suppression suppression 3 x 400 AC 4 k RC 23022 RC 23020 RC 23050 RC 23104 4k RC 2) 231428 DR 23100 4 k DR 23115 RC 7,5 k DR 23115 RC 23104 10 k RC 23011 RC 23010 DR 23118 RC 23106 10 k RC/6-wire 23043 RC/6-wire 23040 20 k DR 23118 DR 23101 3 x 575 AC 4 k RC 23050 7,5 k RC 23035 RC 23030 RC 23104 20 k DR 23102 45 k RC/6-wire 23103 3 x 690 AC 4 k RC 23056 RC 23104 7,5 k RC 23104 20 k DR 23105 echnical data Frequency for RC: 50 60 z for DR: 10 400 z Material flame retardant plastic to L 94 Potting compound 2-component epoxy emperature range -20 +60 C Connection method approx. 500 mm PC cable approx. 200 mm single core approx. 500 mm single core 3 x 0,75 mm 2 resp. 6 x 0,75 mm 2 0,5 mm 2 1 mm 2 self-securing M4 fork terminal ends Dimensions x x 41 x 41 x 41 mm 40 x 15 x 43 mm 61 x 25 x 92 mm M16 x 1,5 or PG 9 3.5.2 For DIN-rail mounting use 2 x Art.-No. 20900 adapter feet. For DIN-rail mounting use 1 x Art.-No. 20900 adapter feet. For DIN-rail mounting use 2 x Art.-No. 20900 adapter feet. For other voltages, frequencies and motor ratings, please inquire. Do not use RC motor suppressors on variable frequency drives. 1 x Art.-No. 23103 required per phase. 2) Art.-No. 231428 has ferrule ends.

with M16 x 1.5 and M20 x 1.5 PG 9 and PG 13.5 screw connector on body on motor terminal box with plug connectors RC 3 R RC 3 R RC 3 R RC 3 R RC 3 RG RC 3 RG with M16 x 1,5 with PG 9 with M16 x 1,5 with PG 9 with M20 x 1,5 with PG 13,5 screw screw screw screw screw screw RC-suppression aristor-suppression (DR) 6-wire ire numbering: =1, =2, =3, 2=4, 2=5, 2=6 1 1 1 2 2 2 Ordering data Art.-No. Art.-No. Art.-No. Art.-No. Art.-No. Art.-No. oltage Motor rating suppression suppression suppression suppression suppression suppression 3 x 400 AC 4 k DR 23170 DR 23110 DR 23175 DR 23119 RC 23141 RC 23140 4k 4k 7,5 k DR 23171 DR 23111 10 k DR 23142 DR 23120 10 k DR/6-wire 23143 DR/6-wire 23125 20 k DR 23144 DR 23121 3 x 575 AC 4 k DR 23172 DR 23112 7,5 k DR 23173 DR 23113 10 k DR 23145 DR 23122 20 k DR 23146 DR 23123 20 k DR/6-wire 23147 DR/6-wire 23126 3 x 690 AC 7,5 k DR 23174 DR 23114 20 k DR/6-wire 2) 23148 DR/6-wire 2) 23127 20 k DR 23149 DR 23124 echnical data Frequency for RC: 50 60 z for DR: 10 400 z Material flame retardant plastic Potting compound 2-component epoxy to L 94 emperature range -20 +60 C Connection method approx. 100 mm single core approx. 150 mm approx 0,5 mm 2 1 mm 2 Ring terminals insulated M6 insulated M4 insulated M6 Dimensions 40 mm, Ø 24,5 mm 44 mm, Ø 39 mm M16 x 1.5 or PG 9 M20 x 1.5 or PG 13,5 33 For other voltages, frequencies, motor ratings, resp. Cable/wire lengths please inquire. Do not use RC motor suppressors on variable frequency drives. wire diameter 1,5 mm 2 2) to max. 660 AC. 3.5.3

on motor terminal box with plug connectors RC 3 S Connector with cable with or without suppression for the brake aristor-suppression (DR) L1 M L2 O L3 O rake R Ordering data Art.-No. Art.-No. oltage Motor rating without brake with brake 3 x 400 AC 4 k 4 k DR/star 23400 DR/star 23420 4 k DR/delta 23410 DR/delta 23430 7,5 k 10 k 10 k 20 k 3 x 575 AC 4 k 7,5 k 10 k 20 k 20 k 3 x 690 AC 7,5 k 20 k 20 k echnical data Frequency for RC: 50 60 z for DR: 10 400 z Plug connector female, 10-pole + PE ousing Aluminium pressure diecasting emperature range -20 +60 C Connection method 3 m PR cable, 4 x 1,5 mm 2 ; numbered wires 3 m PR cable, 7 x 1,5 mm 2 ; numbered wires Dimensions see dimension drawing 70 90 43 105 3.5.4 Pluggable motor connection to DESINA with 5m PR cable 4 x 1,5 mm 2 Art.-No. 236121 on request. Do not use RC motor suppressors on variable frequency drives.

on 35 mm DIN-rail to EN 50022 bolted together, stacked DIN-rail mounted under the control gear RC 3 RC 3 K RC 3 R Connects onto Siemens SIRIS contactors 3 R 10 RC-suppression aristor-suppression (DR) 6-wire 1 ( 1 (2) 1 (3) 2 (4) 2 (5) 2 (6) Ordering data Art.-No. Art.-No. Art.-No. oltage Motor rating suppression suppression suppression 3 x 400 AC 4 k RC 23000 RC 23001 4k RC 2) 23004 RC 2) 23005 4k RC 233463 5,5 k RC 236082 7,5 k 10 k RC 23002 RC 23003 20 k RC/6-wire 23009 20 k DR 23015 3 x 575 AC 7,5 k RC 23006 RC 23007 7,5 k RC 230563 10 k DR 23016 20 k RC 23018 3 x 660 AC 10 k RC 23017 echnical data Frequency for RC: 50 60 z for DR: 10 400 z Material flame retardant plastic to L 94 Potting compound 2-component epoxy emperature range -20 +60 C Connection method 250 mm single core (Art.-No. 23000; 300 mm) 3-pole terminal wire (solid core) 0,5 mm 2 (Art.-No. 23000; 1,5 mm 2 ) 2 x (0,75 2,5 mm 2 ) 1,5 mm 2 self-securing M4 fork terminal ends M4 Dimensions x x 75 x 45 x 42 mm 75 x 45 x 42 mm 40 x 15 x 43 mm For other voltages, frequencies and motor ratings, please inquire. Do not use RC motor suppressors on variable frequency drives. has ferrule ends. 2) max. nominal voltage 3 x 450 AC +10 %. 3.5.5

DIN-rail mounted under the control gear RC 3 AS RC 3 R Connects onto Siemens SIRIS contactors 3 R 10 fixes onto contactors available with integrated coil suppression 2 4 6 A1 A1 14 14 14 14 ire numbering: =1, =2, =3, 2=4, 2=5, 2=6 Appropriate contactors Motor contactors up to 5,5 k from Siemens, Siemens 3 R 10 Moeller, Sprecher + Schuh etc. Ordering data Art.-No. Art.-No. Art.-No. Art.-No. oltage Motor rating suppression suppression suppression suppression 3 x 400 AC 5,5 k RC 23160 DR 23163 RC 23180 DR 23183 5,5 k RC + Diode 23151 DR + Diode 23155 RC + Diode 23191 DR + Diode 23194 5,5 k RC + RC 23150 DR + RC 23154 RC + RC 23190 DR + RC 23197 3 x 575 AC 5,5 k RC 23161 DR 23164 RC 23181 DR 23184 5,5 k RC + Diode 23153 DR + Diode 23157 RC + Diode 23193 DR + Diode 23196 5,5 k RC + RC 23152 DR + RC 23156 RC + RC 23192 DR + RC 23195 3 x 690 AC 5,5 k RC 23182 DR 23185 echnical data Suppression Coil for RC: 230 AC/20 A for diode: 24 230 DC/36 Frequency for RC: 50 60 z, for DR: 10 400 z Material flame retardant plastic to L 94 emperature range -20 +60 C Connection method ferrules, load side securely fixed fits directly into SIRIS contactors, size 00 Dimensions x x 75 x 45 x max. 100 mm ( full stretch) 40 x 45 x 65,5 mm For other voltages, frequencies and motor ratings, please inquire. Do not use RC motor suppressors on variable frequency drives. 3.5.6