MasterFit. The Serviceman s Best Friend!

Similar documents
Direct drive vane axial fans. These totally enclosed/air over motors must be mounted within the airstream for proper cooling.

The Ultimate Truck Stock Motor

EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE.

We will discuss common industrial applications with guides for the proper use of electric motors on these.

FASCO FACTS TIME-SAVING MOTOR REPLACEMENT TIPS

Digi-Motor Installation Guide

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

Features and Benefits. Product Overview. Installation Overview. Sales Strategy Overview FPO

ECM Motors Manufactured By Regal Beloit. Products and Applications- What s an ECM? GEXPRO Regal Beloit s distribution arm for all ECM motor products

Baldor Electric Position on DOE Small Motor Rule

General Information. ME-business can be accessed through: www. marathonelectric.com.

AC Motor Speed. n s = synchronous speed (in RPM), f = frequency (in Hz), and p = the number of poles

SPEED CONTROL SYSTEM

What Do All Those Things on an AC Motor Nameplate Mean?

, User s Manual

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS.

Horizontal Jet Pumps 1/3-1-1/2 HP

E2 Series Electric Furnaces

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS

AC Replacement for DC Mill-Duty Motors

MDT5N25 & MTD5N40 SERVICE PARTS

SMART ELECTRIC. Smart Electric PRODUCT CATALOG. Toll Free

Basic Nameplate Information

This slide is hidden. It will not show up during presentation.

Fireplace Blower, Pellet Stove Auger Motor Woodstove Replacement Blowers

Electric Motor Brake Horsepower Calculations

Rotary Phase Converters

Documenting Results to Validate Energy Savings Projects: Case Study of Direct Drive Cooling Tower Installations: Before and After

Stock Motor Catalog. A Regal Brand

Introduction. Motor Types

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.

Universal electronic. Application: Integrates control of combustion blower and circulating fan operations for a gas warm air appliance

(3) Explosion proof. Designed to prevent ignition of any explosive gases or dust and dirt which may surround the motor.

I hope you find them useful and I would appreciate any comments or thoughts you might have for future improvements, corrections or topics.

Fundamentals of Inverter Fed Motors

UM Series UniModule. Pre-assembled, C-face Clutches and Brakes. Original Design Sizes 210 & 215. GEN 2 Design Sizes 50, 100 & 180

Score 1,500. bonus points online when you sign up for PRO Plus. (by registering through Ferguson Online)*

KTM AC to DC Stator Conversion Instructions (Floating the ground)

Specifying a Variable Frequency Drive s

Recirculating Roof Fans Models ESRMD, ESRMDF and ERD

DC MOTORS NEMA FRAME SCR RATED

AIR HANDLERS AIR HANDLERS AIR HANDLERS. RHLA- High Efficiency. featuring R-22 Refrigerant. RHLL- High Efficiency

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

Wound Rotor Induction Motors 4-12 poles, up to 8000 kw, HP

ECM SERVICE GUIDE. A Regal Brand Regal-Beloit Corporation

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

WE-350 Series ¼ Turn Electric Actuator

AC motors catalogue.

Solving VFD-sourced Bearing Current Problems in AC Motors.

Motor Specifications. Nameplate

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

SECTION MORTUARY REFRIGERATORS

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

300 Series PA Pump and Cooler Assemblies

Introduction. Upon completion of Basics of AC Motors you should be able to:

Talon and Talon SR User Manual

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

Thru-the-wall AIR CONDITIONERS COOL ONLY HEAT PUMPS ELECTRIC HEAT

Commercial Gas Furnace Upflow

Tuning Up DC Motors and Generators for Commutation and Performance

Motor Accessories. C-Face Kits for Field Conversion NEMA AC Motors

Diesel Engine Driven Generators Page 1 of 6

Installation Manual CLIFC Fan & Coil Variable Speed

COLEMAN-MACH AIR CONDITIONER PARTS In Section Q: Atwood Coleman (RVP) Cooling Units Dometic Norcold Powerhouse Suburban Thetford Wedgewood X-Reference

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

Performance Rating of Room Fan- Coils

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

TECHNICAL INFORMATION Bulletin

SEWER CHEWER Wastewater / Sludge Grinder Submersible Gearmotor

Data Sheet. AC Industrial Electric Motors

D.C. Motors. Products and specifications subject to change without notice.

EM Series Electrically Released Brakes

Permanent Magnetic Couplings and Brakes for Drive Technology

TEST REPORT #44. System Drop-in Tests of Refrigerant R-32 in Single Packaged Vertical Heat Pump (SPVH)

TECHNICAL BULLETIN ALL S2 CX S. BEHR Heater system: modifications

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

Application Information

AC Electric Motors best practice

How To Drive A Compact Serie 1

COOLING TECHNOLOGY INSTITUTE

GE Industrial Systems. AC Motor Selection and Application Guide

Horizontal Split Case Fire Pumpset Electric Motor Driven 50 Hz

Low Profile Unit Cooler

AC axial fans A series

50Hz SUBMERSIBLE MOTORS APPLICATION INSTALLATION MAINTENANCE

Model 413 AURORA. 410 Series SINGLE STAGE SPLIT CASE PUMPS

EQUIPMENT GUIDE. Rvsd THIS GUIDE IS INTENDED FOR THE END USER. GEAR PLATE ASSEMBLY ELECTRIC MOTOR WIRING DIAGRAM DRUM SWITCH GFCI WARRANTY

Electric Motors and Drives

Owner s Manual EFX. Explosion-Proof Exhaust Fan. This manual covers installations, maintenance, repair and replacement parts. WARNING!

STAR Linear Bushings and Shafts Supplement RE / Linear Motion and Assembly Technologies

Roof Top Unit. Description Model Type Use With Air Distribution Box. Heat Pump B Integral Mechanical

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

1.9" (48mm) Slotless Brushless DC motor.

Motor Protection Voltage Unbalance and Single-Phasing

BASIC TRAINING. Go On-Line With LEESON! LEESON MOTORS, GEARS & DRIVES L E E S O N B A S I C

Transcription:

MasterFit The Serviceman s Best Friend!

MasterFit : One Motor Replaces Many Features: Energy Efficient Different Capacitor/ Speed Combinations Designed for 370V Capacitor (not furnished) Permanent Split Capacitor Ball and Sleeve Bearing Rotation Reversible Resilient Rings on Blower Motors Extended Thru Bolts Automatic Protector Class B Insulation 48 Frame Single Phase Continuous Duty Air Over Mounts by Belly Band, Thru Bolts or Shell Holes Rheem Mounting Holes in Shell 60 Hertz Benefits: Less Inventory Required Versatile Time Saver Easy Installations

MasterFit : Speeds to use Direct Drive Fan & Blower Motors Features: Energy Efficient 4 Speed Ambient 40 C Class B Insulation 60 Hertz Open Dripproof Permanent Split Capacitor Reversible Resilient Rings Mounts by Belly Band, Thru Bolts or Shell Holes Extended Thru Bolts Rheem Mounting Holes in Shell 1075 RPM Applications Sleeve Bearing Motor Speeds to Use * (Color/Approx. RPM) 370V FDL6001 FD6000 To Replace Cooling Heating Capacitor 115V FLA 208-230V FLA 1/2 HP High (Black/1100) Med-Hi (Blue/1050) or Med-Lo (Yellow/825) 10 mfd 7.0 3.9 1/3 HP High (Black/1120) Med-Hi (Blue/1090) or Med-Lo (Yellow/1030) 5 mfd** 6.7 3.6 1/4 HP Med-Hi (Blue/1125) Med-Lo (Yellow/1090) or Lo (Red/1010) 5 mfd** 4.4 2.5 1/5 HP Med-Lo (Yellow/1110) Lo (Red/1060) 5 mfd** 3.2 1.8 1/6 HP Lo (Red/1085) Lo (Red/1085) 5 mfd** 2.4 1.3 1075 RPM Applications Ball Bearing Motor Speeds to Use * (Color/Approx. RPM) 370V FDL6002 FD6001 To Replace Cooling Heating Capacitor 115V FLA 208-230V FLA 3/4 HP High (Black/1110) Med-Hi (Blue/1080) or Med-Lo (Yellow/1010) 10 mfd 9.1 3.9 1/2 HP High (Black/1130) Med-Lo (Yellow/1090) or Lo (Red/1035) 10 mfd 6.6 3.6 1/3 HP Med-Hi (Blue/1150) Med-Lo (Yellow/1130) or Lo (Red/1100) 5 mfd** 5.5 3.0 1/4 HP Med-Lo (Yellow/1150) Lo (Red/1130) 5 mfd** 3.0 2.3 1/5 HP Lo (Red/1140) Lo (Red/1140) 5 mfd** 2.3 2.0 *RPM data from cold motor at nominal horsepower. Actual load will determine effective rpm. **Using a 7.5 mfd/370v capacitor will results in an approximately 10% stronger motor.

MasterFit : Speeds to use Condenser Fan Motors Features: Energy Efficient 2 Speed Ambient 60 C Class B Insulation 60 Hertz Totally Enclosed Permanent Split Capacitor Automatic Protector Reversible All Position Mounting Mounts by Belly Band, Thru Bolts or Shell Holes Extended Thru Bolts Rheem Mounting Holes in Shell LA FE6001 (208-230V) 825 RPM Applications Ball Bearing 1/3 HP High (Black/825) 10 7.5 1.9 1/4 HP High (Black/835) 10 7.5 1.5 1/5 HP Lo (Red/825) 10 7.5 1.2 1/6 HP Lo (Red/835) 10 7.5 1.0 FE6003 (208-230V) 825 RPM Applications Ball Bearing 1/2 HP High (Black/825) 12.5 10 2.4 1/3 HP High (Black/835) 12.5 10 1.7 1/4 HP Lo (Red/825) 12.5 10 1.4 1/5 HP Lo (Red/835) 12.5 10 1.1 LA FSE6000 (208-230V) 1075 RPM Applications Sleeve Bearing 1/3 HP High (Black/1110) 7.5 5 2.8 1/4 HP High (Black/1135) 7.5 5 2.0 1/5 HP Lo (Red/1110) 7.5 5 1.7 1/6 HP Lo (Red/1125) 7.5 5 1.5 FE6000 (208-230V) 1075 RPM Applications Ball Bearing 1/3 HP High (Black/1110) 7.5 5 2.8 1/4 HP High (Black/1135) 7.5 5 2.0 1/5 HP Lo (Red/1110) 7.5 5 1.7 1/6 HP Lo (Red/1125) 7.5 5 1.5 FE6002 (208-230V) 1075 RPM Applications Ball Bearing 1/2 HP High (Black/1110) 12.5 10 3.9 1/3 HP High (Black/1135) 12.5 10 2.2 1/4 HP Lo (Red/1110) 12.5 10 1.6 1/5 HP Lo (Red/1125) 12.5 10 1.3 FE6004 (208-230V) 1075 RPM Applications Ball Bearing 3/4 HP High (Black/1110) 15 12.5 5.3 1/2 HP High (Black/1135) 15 12.5 3.0 1/3 HP Lo (Red/1110) 15 12.5 1.9 1/4 HP Lo (Red/1125) 15 12.5 1.0 *RPM data from cold motor at nominal horsepower. Actual load will determine effective rpm. ***Note: based on using a 370V capacitor.

MasterFit : Specifications Condenser Fan Motors Ambient 60 C Totally Enclosed Capacitor Stock 370 Volts Speeds to Lead Shell Shaft No. HP 208V 230V Use Amps RPM Volts Bearings Lengths Dimension Length FE6001 1/3 10 mfd 7.5 High 1.9 825 208-230 Ball 36 5.24 1/2 x 5 1/4 10 mfd 7.5 High 1.5 1/5 10 mfd 7.5 Low 1.2 1/6 10 mfd 7.5 Low 1.0 FE6003 1/2 12.5 mfd 10 High 2.4 825 208-230 Ball 36 5.61 1/2 x 6 1/3 12.5 mfd 10 High 1.7 1/4 12.5 mfd 10 Low 1.4 1/5 12.5 mfd 10 Low 1.1 FSE6000 1/3 7.5 mfd 5 High 2.8 1075 208-230 Sleeve 36 4.86 1/2 x 6 1/4 7.5 mfd 5 High 2.0 1/5 7.5 mfd 5 Low 1.7 1/6 7.5 mfd 5 Low 1.5 FE6000 1/3 7.5 mfd 5 High 2.8 1075 208-230 Ball 36 4.86 1/2 x 6 1/4 7.5 mfd 5 High 2.0 1/5 7.5 mfd 5 Low 1.7 1/6 7.5 mfd 5 Low 1.5 FE6002 1/2 12.5 mfd 10 High 3.9 1075 208-230 Ball 36 5.24 1/2 x 5 1/3 12.5 mfd 10 High 2.2 1/4 12.5 mfd 10 Low 1.6 1/5 12.5 mfd 10 Low 1.3 FE6004 3/4 15 mfd 12.5 High 5.3 1075 208-230 Ball 36 5.87 1/2 x 6 1/2 15 mfd 12.5 High 3.0 1/3 15 mfd 12.5 Low 1.9 1/4 15 mfd 12.5 Low 1.0 Direct Drive Fan & Blower Motors Ambient 40 C Open Dripproof n Motor is approximately 10% stronger and has higher starting torque for 1/6, 1/5, 1/4, and 1/3 HP rating with the 7.5 mfd 370 Vac capacitor. Stock Capacitor Speeds to Lead Shell Shaft No. HP 370 Volts Use Amps RPM Volts Bearings Lengths Dimension Length FDL6001 1/2 10 mfd All 7.0 1075 115 Sleeve 26 4.86 1/2 x 5 1/3 5 mfd 7.5 n All 6.7 1/4 5 mfd 7.5 n Lo,Med-Lo,Med-Hi 4.4 1/5 5 mfd 7.5 n Lo,Med-Lo 3.2 1/6 5 mfd 7.5 n Lo 2.4 FD6000 1/2 10 mfd All 3.9 1075 208-230 Sleeve 26 4.86 1/2 x 5 1/3 5 mfd 7.5 n All 3.6 1/4 5 mfd 7.5 n Lo,Med-Lo,Med-Hi 2.5 1/5 5 mfd 7.5 n Lo,Med-Lo 1.8 1/6 5 mfd 7.5 n Lo 1.3 FDL6002 3/4 10 mfd All 9.1 1075 115 Ball 38 4.86 1/2 x 5 1/2 10 mfd All 6.8 1/3 5 mfd 7.5 n All 5.5 1/4 5 mfd 7.5 n Lo,Med-Lo,Med-Hi 3.0 1/5 5 mfd 7.5 n Lo,Med-Lo 2.3 FD6001 3/4 10 mfd All 3.9 1075 208-230 Ball 38 4.86 1/2 x 5 1/2 10 mfd All 3.6 1/3 5 mfd 7.5 n All 3.0 1/4 5 mfd 7.5 n Lo,Med-Lo,Med-Hi 2.3 1/5 5 mfd 7.5 n Lo,Med-Lo 2.0

MasterFit : Cross Reference Condenser Fan Motors A. O. Smith Grainger Emerson G.E. Protech Fasco Marathon FE6001 1UME6 5464 3469 D2826 FE6003 * FSE6000 * 51-23053-21 D837 FE6000 4ME30 5462 3465 D2827 X072 FE6002 * 5465 3468 X076 FE6004 * *Via through Grainger sourcing - ask your Grainger Representative for more information Direct Drive Fan & Blower Motors A. O. Smith Grainger Emerson G.E. Protech Fasco Marathon FDL6001 4ME32 5460 3463 51-23012-41 D2835 X077 FD6000 4ME34 5461 3464 51-23022-41 D833 X073 FDL6002 4ME26 5470 3466 D2832 X074 FD6001 4ME28 5471 3467 D2833 X075 Copyright 2009 A. O. Smith Corporation Bulletin #6000B-WWG 4-09