Rotary Plate DT1600. Operating Manual. Table of Contents



Similar documents
TIG INVERTER INSTRUCTION MANUAL

Product and functional description

FF30. Flexicon. Operator s Manual. FF30-F In-feed Rotary Table. OPERATOR S MANUAL Serial Number yyww xxxx. Filling and Capping System

MINI MCR-SL-R-UI(-SP)

CMC III Temperatur-/ Feuchtesensor CMC III Temperature/ Humidity Sensor

1115 4G SERIES GOVERNOR ma ANALOGUE DIGITAL SPEED SETTING

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

- Designed to meet with the environmental stresses of ships and heavy industry. SESOBS

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

ZMR 80 STEREO MODULAR ZONER USERS MANUAL

INFRARED QUARTZ WALL HEATER

CYMAQ Marking System AS200 + DS7050 N-14

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.

PowlVac Vacuum Integrity Tester

Remote Head REMO ONE. Code Manual

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

Operating Instuctions. Shaking device SV 14 / 22 SV 29 / 45. page 1

Installation guide H A. HSI hardwired system interface

Thyristor-controlled power supplies and battery chargers

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Power Generation. Power Control PCL System Generator Set Control

MB-Accumulator Operator's Manual

SYSTEM DESCRIPTION Termination Boards

BroadBand PowerShield. User Manual

Achat 208 HL / 208 HR passive mid-range speaker. user manual


PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: TABLE OF CONTENTS

alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

Achat 115MA full-range speaker. user manual

SYSTEM 4C. C R H Electronics Design

OPL BASIC. Dosing System for Professional Laundry machines. Contents

User Manual. CFG253 3 MHz Function Generator

Manual Ranging MultiMeter

Operating Instructions for Plastic Flow Meter. Model: KSK

Power Thyristor TS3 (SP) 3ph. Installation Guide

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

Quick Connect. quick - simple - efficient.

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

Directions for use : Dosing chutes type DSX.

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

GAE953 Electrical Alarm Unit 19" with Indicator

mecotron Safety relay ESTOP-2 For emergency stop monitoring

PHOENIX CONTACT - 01/2007

SECTION VARIABLE FREQUENCY DRIVES

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

Antenna Splitter ASA 1. Instruction manual

Technical data UNIBLOCK UBSF

Installation and safety instructions for AC/DC built-in devices

BG or BGE Brake Rectifier

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Elektromotoren und Gerätebau Barleben GmbH

How To Service A Paper Shredder

FT-100 Fire Training Fog Machine User Manual English

46120-F0 Solar Energy Training System

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

ELECTRIC BICYCLE USER MANUAL

Safety Relays ESM/ESM-F

Instructions for Safe Use

PHOENIX CONTACT Features

19 LED Tube Controller ORDERCODE 41003

CELO5. User & Installation Manual.

Doc. No: Issue: 1 Date: Aug BTT-02 card printer manual THERMAL TRANSFER CARD PRINTER BTT-02

VIESMANN. Installation and service instructions VITOTROL 100. for contractors

Operating Instructions Drill rig DRU160

Ref. Nr LCP-288 LED COLOR PANEL 288X LED 5MM MANUAL

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

AutoRanging Digital MultiMeter

PART 1 - INTRODUCTION...

HERZ-Thermal Actuators

Mounting Instructions. Torque Transducer. A en

Operating Instructions

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

LOXONE 12 Channel Amplifier

Safety automation solutions

User s Manual Before using the inverter, you need to read and save the safety instructions.

Cable Plug acc. to DIN EN , Form A

CURRENT TRANSFORMERS INSTALLATION GUIDE

Operating Instructions. Incl. Declaration of Conformity. Control Unit RVG 050 C BG BE (0103) 1

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

Rittal TopTherm fan-and-filter unit

Gemini II. Subwoofer System OWNERS MANUAL

Fire Alarm Control Panel. Family. Operating Manual

High Security Heavy Duty Shredders VZ Perfect shredding and high performance in DIN security levels 4 and 5

MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances

How To Use A Cdm250 Digital Multimeter

Achat 110 M passive full-range speaker. user manual

A good connection. International approvals.

AXIS T81B22 DC 30W Midspan

FLEXIT S4 R S6 R S7 R

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

Brio-Rmanual:Cursamanual.qxd 08/04/ :25 Page1

Transcription:

Table of Contents 1.0 Manufacturer 2.0 Machine Type and Specifications 3.0 Delivery 4.0 Setup 5.0 Connection and Interfacing 6.0 Application and Processing Instructions 7.0 Safety Instructions 8.0 Description of Operating Elements 9.0 Taking into Service and Operation 10.0 Terminal Chart 11.0 Spare Parts List, Electrical 12.0 Maintenance and Care / Decommissioning 13.0 Troubleshooting 14.0 EC - Declaration of Conformity 15.0 Parameter List for Frequency Converter - 1 -

1.0 - Manufacturer ULMER GmbH Auf den Lüppen 35745 Herborn Hörbach Germany Telephone: +49(0)2772/51000 Fax: +49(0)2772/51677 Email: info@ulmer-gmbh.de Homepage: www.ulmer-gmbh.de Amtsgericht Herborn HR 191 Managing directors: Siegfried Ulmer Werner Ulmer 2.0 - Machine Type and Specifications Machine type: Rotary plate DT1600 Drive: Three-phase drive Speed: up to 60 m/minute Length: 2000 mm Width: 1600 mm Height: 700 mm (top edge of control cabinet) plus output arm Weight: approx. 220 kg Electrical connection: 230 V/50-60 Hz/10 A 3.0 Delivery Immediately after unpacking, check the rotary plate DT1600 for transport damage, such as distortion and/or loose parts. If damage is detected: Immediately contact ULMER GmbH. Important! Do this also if the packing is damaged! 3.1 - Scope of Supply Rotary plate DT1600 Operating Manual 3.2 - Available Accesories Connecting cable X3 / DT1600 WSM30/SM15 Connecting cable X4 / DT1600 WSM30/SM15 4.0 - Setup The rotary plate must be setup on a level surface. 5.1 Electrical Connection The rotary plate DT1600 must be connected to a properly connected power socket with protective earth conductor (230 V/50-60 Hz), using the installed plug. The line fuse must not exceed 10 A. - 2 -

5.2 Linkage When the rotary plate DT1600 is operated in conjunction with other machinery, the following connections for linkage must be achieved: EMERGENCY STOP signal from external machine EMERGENCY STOP signal to external machine 6.0 - Application and Processing Instructions The rotary plate DT1600 is designed to wind up corrugated tubing. During operation, the rotary plate will automatically increase or reduce its winding speed as needed. This will allow to place the corrugated tube in Layers in the transport carton. Be sure to position the carton at the center of the rotary plate (stop rail). Note! Applications not here listed must be approved in writing by ULMER GmbH. We are pleased to respond to your further questions. 7.0 - Safety Instructions The rotary plate must be set up safely on a level surface. Do not put objects onto the machine. Be sure to link the rotary plate DT1600 with subsequent machinery (sockets at the control cabinet). Before linking it to other machinery, please contact ULMER GmbH. Before starting maintenance work, separate the machine from the power supply. Protect the unit from moisture and do not operate it in wet rooms. Have transport to another site in your works performed by trained specialists. During operation, do not reach with your hands or objects into the danger area of the rotary plate. Do not stand on the rotary plate while it is operating. 8.0- Description of Operating Elements Red push-button STOP The rotary plate stops within the time defined with the frequency converter parameters. Green push-button START The rotary plate is set to the ready status and accelerates during the set acceleration time to the nominal speed. When the set speed ist reached, the timer relay is activated and the rotary plate speed is reduced continuously during the set time. After time out, the speed will increase again. Potentiometer FEED Use this potentiometer to set the maximum speed to be reached. Black push-button TOUCH- Control Depending on the selected sense of rotation, the rotary plate will rotate at the set slow speed as long as you keep this button pressed Selector switch SENSE OF RO- TATION This switch allows you to select the sense of rotation of the rotary plate. Timer relay RETURN TIME The relay defines the time during which the rotary plate is to operate at lower speed. After time-out of this time, the rotary plate will accelerate to the original setpoint. - 3 -

9.0- Taking into Service and Operation Switch the rotary plate DT1600 on using the main switch. By pressing the push-button TOUCH Control, turn the rotary plate until it has reached the feed position for the carton. Position the carton at the cen- tre of the rotary plate (stop rails). Select the sense of rotation at the selector switch. Set the speed at the potentio - meter FEED. Feed the material to the carton. Switch the rotary plate on by pressing the green push-button START. The rotary plate now winds up the corrugated tube fed. 10.0- Terminal Chart Designation in diagram Connection Terminal number Connection Designation in diagram Supply PE PE Supply L1 L1 1 F 1.11 Supply N N 3 F 1.11 EMERGENCY STOP from customer EMERGENCY STOP from customer EMERGENCY STOP signal to customer EMERGENCY STOP signal to customer PE 1 12 S 1.61 2 A1 K 1.61 3 21 S 1.61 4 22 S 1.61 External stop 5 34 S 3.41 External stop 6 18 A 4.21 External start 7 17 A 4.21 External start 8 A1 K 2.31 PE PE - 4 -

11.0 Spare Parts List, Electrical Design Article Type designation Supplier Location Article no. A 4.21 Frequency converter SK750/1FCT Nordac S A 4.21 Operating panel mc Nordac S F 1.11 Circuit-breaker 10A/1polig Siemens S F 1.31 Circuit-breaker 2A/1polig Siemens S F 1.41 Fuse holder 282-120 Wago F 1.41 Fine fuse 1A / 5x20 G 1.31 Power supply unit NTG24-1.00 Konzept S H 3.21 Light bulb BA9 / 30VDC Telemecanique S H 3.21 Lamp socket ZBV 6 Telemecanique S H 3.31 Light bulb BA9 / 30VDC Telemecanique S H 3.31 Lamp socket ZBV 6 Telemecanique S K 1.61 Power contactor DIL-EM-10G Moeller S K 2.31 Relay 55.34.9.024.0090E Finder S K 2.31 Relay socket 94.84.1 Finder S K 2.41 Relay 55.34.9.024.0090E Finder S K 2.41 Relay socket 94.84.1 Finder S K 2.51 Timer relay KOL 111 SAIA S K 2.71 Timer relay GT3A-4AD24-MK643 IDEC S K 2.71 Installation frame RTB-G01 IDEC S K 2.71 Connecting socket SR3P-05E IDEC S K 3.41 Relay 55.34.9.024.0090E Finder S K 3.41 Relay socket 94.84.1 Finder S K 3.51 Relay 55.34.9.024.0090E Finder S K 3.51 Relay socket 94.84.1 Finder S M 4.21 Three-phase drive Gearbox 0,55 kw Getriebebau NORD DT Q 1.11 Main switch KG20A T103/04 FT22 Kraus & Naimer S R 4.51 Potentiometer 10k Ohm Rossmanith S R 4.51 Pot drive ZB5 AD912 Telemecanique S R 4.51 Label carrier ZBZ 35 Telemecanique S - 5 -

11.0 - Spare Parts List, Electrical Bez. Artikel Typenbezeichnung Hersteller Ort Artikelnummer S 1.61 EMERGENCY STOP button ZB5 AS844 Telemecanique S S 1.61 Mounting flange AZ 009 Telemecanique S S 1.61 Contact element 1Ö ZBE 102 Telemecanique S S 1.61 Contact element 1Ö ZBE 102 Telemecanique S S 1.61 Contrast label ZBY 9230 Telemecanique S S 2.21 Luminous push-button, red ZB5 AW34 Telemecanique S S 2.21 Mounting flange AZ 009 Telemecanique S S 2.21 Contact element 1Ö ZBE 102 Telemecanique S S 2.21 Label carrier ZBZ 35 Telemecanique S S 2.31 Luminous push-button, green ZB5 AW33 Telemecanique S S 2.31 Mounting flange AZ 009 Telemecanique S S 2.31 Contact element 1S ZBE 101 Telemecanique S S 2.31 Label carrier ZBZ 35 Telemecanique S S 3.41 Selector switch ZB5 AD2 Telemecanique S S 3.41 Mounting flange AZ 009 Telemecanique S S 3.41 Contact element 1S ZBE 101 Telemecanique S S 3.41 Contact element 1Ö ZBE 102 S 3.41 Label carrier ZBZ 35 Telemecanique S S 4.71 Push-button, black ZB5 AA2 Telemecanique S S 4.71 Mounting flange AZ 009 Telemecanique S S 4.71 Contact element 1S ZBE 101 Telemecanique S S 4.71 Label carrier ZBZ 35 Telemecanique S 1 Stück Control cabinet AE1038/500 Rittal - 6 -

12.0 Maintenance and Care The rotary plate DT1600 requires little maintenance. Only ensure cleanliness and correct operation. Note! Do not use aggressive solvents for cleaning! Safety instruction! Check and clean the rotary plate only when it is disconnected from power! 12.1 Temporary De-Commissioning When decommissioning the rotary plate DT1600 disconnect the machine from the power supply and cover it to protect it from dust, moisture and dirt. 13.1 Red Checklight is not on after Power-Up Line fuse on sitedefective Circuit-breaker F1.11 has cut out Circuit-breaker F1.31 has cut out Power supply unit G1.31 defective Fuse F1.41 defective Failure of frequency converter A4.21 Consult the operating instructions of the manufacturer. 13.2 Rotary Plate cannot be started (red checklight is on) Switch-on relay K2.31 faulty 13.3 Rotary Plate always runs at the same speed Connection between frequency converter and potentiometer faulty Timer relay K 2.71 faulty Warning message of frequency converter A4.21 Consult the operating instructions of the manufacturer. 13.4 Rotary Plate shuts off automatically Failure of frequency converter A 4.21 Consult the operating instructions of the manufacturer. - 7 -

14.0 - Declaration of Conformity acc. to. EC Machinery Directive We ULMER GmbH Auf den Lüppen 35745 Herborn Hörbach Germany herewith declare at our sole descretion that the product XXXX / YYYY to which this declaration refers, is in conformity with the following standards and governing documents. 1. EC Machinery Directive, Annex 1 Essential health and safety requirements relating to the design and construction of machinery. 2. DIN EN 292 parts 1 and 2 Safety of machinery; basic concepts, general principles for design. 3. EN 60204/DIN VDE 0113 Electrical equipment of machinery. 4. DIN EN 294 Safety distances to prevent danger zones from being reached. We herewith confirm that the evaluation procedure according to the Directive 89/392/EEC (06/14/1989), ammended by 91/368/EEC (06/20/1991), ammended by 93/68/EEC (08/30/1993) Council directive on the approximation of the laws of the member states relating to machinery. Has been followed and that the requirements of the standard DIN EN 45 014 General criteria for supplier s declaration of conformity have been observed in the issue of the declaration of conformity. Signature Company stamp - 8 -

15.0 Parameter List for Frequency Converter of Parameter Function Adjustable range Set value OK P002 Run-up time 0... 650.0 sec. 32 sec. P003 Return time 0 650.0 sec. 32 sec. P006 Frequency setpoint select 0... 2 1 P007 Keypad operation 0... 1 0 P009 Key parameter 0... 3 0-3 P013 Maximum frequency 0... 650.0 Hz 97 Hz P022 Maximum frequency 0... 650.0 Hz 97 Hz P031 Touch-control setpoint, righthand 0... 650,0 Hz 20 Hz P032 Touch-control setpoint, lefthand 0... 650,0 Hz 20 Hz P033 Run-up value touch-control setpoint 0... 650,0 sec 8 sec P034 Return value touch-control setpoint 0... 650,0 sec 8 sec P051 Control function select 0 17 2 P052 Control function select 0 17 1 P053 Control function select 0 17 8 P054 Control function select 0 17 7 P055 Control function select 0 17 16 P062 Relay function select 0 17 7 P078 Static boost 0-250 % 50 % P080 Cos. PHI 0 650.0 0,69 P081 Rated motor frequency 0 650.0 Hz 50 Hz P082 Rated motor speed 0 9999 U/min 1390 U/min P083 Rated motor current 0.1 99.9 A 2,1 A P084 Rated motor voltage 0 1000 V 230 V P085 Rated motor output 0 50.0 kw 0.37 kw P086 Motor current limit 0 250 % 170 % Schlemmer GmbH Gruber Strasse 48 85586 Poing / Germany - 9 - info@schlemmer.com www.schlemmer.com www.schlemmer-ecotech.com