ROCK WOOL Preformed Pipe Section



Similar documents
ProRox Slabs (formerly known as RW slabs)

Twiga Insul. India's Leading Thermal and Acoustic Insulation. Insulating India

ROCKWOOL Rigid, Semi-rigid and Flexible Slabs are high quality resin bonded slabs that can be used for thermal, acoustic and fire insulation.

Edition: Export Published: 09/2010. Product catalogue. Technical and industrial insulation. Lapinus

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

ROXUL Board Insulation Section Master Guide Specification (CAVITYROCK ) Page 1 April 2016

INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings

EcoTouch Insulation with PureFiber Technology

THERMAL INSULATION MATERIALS TEST METHOD SELECTION LIST

NEW NEW. Pipe Products Catalogue. ProRox NEW NEW. Pipe Insulation for High Temperature Industrial Applications PRODUCT NAMES

Marine & Offshore Insulation. - products and constructions November 2009

Roxul Board Insulation Section Master Guide Specification (CAVITYROCK DD) Page 1 October 2013

Fiberglas, Exterior Wall Thermal Insulation

Stonewool Insulation for Thermal, Acoustic and Fire Safety Building Applications

TABLE OF CONTENT

Rockwool Cladding Roll

Removable Insulation Blankets from A to Z

Mineral fibreglass insulation

Edition: Export Published: 11/2007. Product catalogue. Lapinus

Rockwool Flexi Insulation Application Guide

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation

SECTION FIBERGLASS INSULATION

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

2.1 DEFINITION OF INSULATION GENERIC TYPES AND FORMS OF INSULATION PROPERTIES OF INSULATION MAJOR INSULATION MATERIALS 4

03/05/14 REVISOR RSI/JC RD3945

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

Physically Crosslinked Foam Insulation

Formwork Direct International Ltd Phone No +44 (0151) Fax no +44 (0151)

PAGE 2. Figure 1: Difference between PWL ins and SPL 1m

ASTM Volume 04.06, November 2015 Thermal Insulation; Building and Environmental Acoustics

Technical Specification Fire Blanket Firemaster Fire Protection-Cables Tray Fire Protection Department

Annex of the certificate (Page 1/6) Accreditation Scope

Enclosures DuraSystems Barriers, Inc. The Passive Fire Protection Specialists

STENCA PIPE. High quality pipe insulation.

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors

Cannon T4 Modular Data Centres. For Outside Deployment & Challenging Environments

INSULATION PRODUCTS. The quality you expect. The options you need. Insulation Softboard. Cork Board. Fibreglass Insulation.

Marine Exhaust Insulation

SECTION HVAC INSULATION. A. All work specified in this Section is subject to the provisions of Section

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

COLD Heat Fire

Tremco Fire Protection Systems Group Technical Bulletin

HVAC Solutions. For heating and air conditioning applications

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

TARIFF CODE and updates standard

STENCA HT PIPE. Quality Insulation made of calcium silicate.

MECHANICAL INSULATION BEST PRACTICES GUIDE TABLE OF CONTENTS

SPREFIX SPRAY INSULATION _ in the marine market.

ROXUL TOPROCK DD & MONOBOARD. Roofing Insulation for Commercial Construction. ROXUL TOPROCK DD and MONOBOARD

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

High Temperature Industrial Textiles

UniPlate. Solar Collectors SOLAR SYSTEMS.

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

Environmental Education Associates. Asbestos in Construction

Fire & Soundproofing Insulation. Roxul SAFE N SOUND. Fire and Soundproofing Insulation for Interior Partition Walls and Floors.

Standard Specification for Cellular Glass Thermal Insulation 1

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP

Light-Weight Panels. High quality panels.

Conlit fire protection

PTFE Slide Bearings 04/10 149

Product Information Sheet. Fiberfrax Blanket and Mat Products

ROXUL COMMERCIAL ROOFING. Understanding Climate Requirements That Drive Performance. roxul.com

CHAPTER 7: Building Systems ROOFING SYSTEMS

PRODUCTS & SOLUTIONS - MARINE & OFFSHORE INSULATION. according to. SeaRox. Products & Solutions. Marine & Offshore Insulation

FLEX-WRAP Foam Pipe Wrap

SECTION HVAC INSULATION

European technical approval

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

Composite Panel Firewall Systems

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MECHANICAL INSULATION

Product Information Sheet

ISO Types 1-6: Construction Code Descriptions

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

Excerpts from the Canadian National Building Code (NBC)

Housing Fact Sheets. Insulation Check-Up

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with

Company and Product Presentation

SIGRAFLEX . Properties. Applications

Flanged and Butt-= Weld Type

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Pipe Protection Tape System

FIBRANgeo. Stonewool thermal insulation, sound insulation and fire protection products for building applications

Bafl-Sorb Sound Absorbing Ceiling Baffles

Asbestos in the home. A guidance booklet for tenants. Please keep this document as a reference guide- It contains important safety information

B. Types of mechanical insulation specified in this section include the following:

WEEKLY SAFETY MEETING All Euramax Subsidiaries COMBUSTIBLE DUST. Safety Meeting Contents. Meeting Notice. Leaders Guide.

8 EXTRA LIGHT GRC SANDWICH ELEMENTS FOR ROOFING IN INDUSTRIAL BUILDINGS

Industry Insulation. Insulation Solutions for Industry Applications. New CE marking and Isover TECH product range

3 Single-Coated Foam Tapes

OUTSTANDING CHARACTERISTICS OF TEKFOIL HI-PERFORMANCE REFLECTIVE INSULATION

European Technical Approval ETA 13/0526

ModuSec. Secure and efficient IT room solutions Composite Panel Systems Compared. Panel Systems are not all the same!

SANDWICH PANEL FILLING MATERIALS

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Anodes and Misc Equipment

Underwriters Laboratories Testing Information

Transcription:

ROCK WOOL Preformed Pipe Section Rockwool preformed Pipe section conforming ASTM C 547 and equivalent BS39584 is intended for the thermoacoustic insulation and fire protection of pipe works operating at temperatures up to 780 º C. The pipe insulation is manufactured from long noncombustible rock fibers with a high performance binder. It is easy to cut, fit, handle and has high levels of thermal efficiency and strength. each section is split and hinged for easy, snapon applications. Designed for tough thermal and acoustic insulation pipe works it's combination of density, strength, and excellent thermal conductivity at high temperatures offer efficient insulation. It is highly applicable for industrial steam and process pipe lines in oil refineries, chemical plants and power stations. It also has the versatility to be used in heating and ventilating or other nonindustrial applications. Facings: This product can be faced with aluminum fill. Types: Code CXXX C2XX Description Unfaced pipe section Pipe section with aluminium foil facing Acoustical Properties: Suitable for Acoustical insulation as per BS3638 and ISO0354. Standard Delivery: Thickness are available from 25 mm to 100 mm and 1/4" up to 24" pipe diameters. The density ranges from 90 to 180 for higher pipe sizes bevelled layers are available on request. Thermal Conductivity: Rockwool pipe section shows remarkably low thermal conductivity values. Typical figures are shown as tested in accordance with ASTM 335 Mean Temp C kvalue W/mk 100 kvalue W/mk 140150 50 0.037 0.035 100 0.044 0.041 150 0.052 0.048 200 0.061 0.056 250 0.072 0.065 300 0.084 0.078

Service Temperature: Has a maximum service of 750 º C ( 1440 º F ) when tested in accordance with DIN 52271 and ASTMC 411. It can be used in continuous service temperatures up to 850 Cº. Fire Safety: Non combustible when tested in accordance with BS476 part 4 and ASTM E 136. Class I, when tested in accordance with BS476 part7 and ASTM E84. Fire resistance with integrity up to240 min and insulation up to 196 min, when tested as per BS476 part 20. Compatibility: Compatible with all forms of material with which it is likely to come in contact in normal industrial and building applications. Physical Properties: Asbestos free with a short content of 4% mass/mass when tested in accordance to BS 2972 : Section 14 and ASTM612. Moisture: Waterrepellent, nonhygroscopic, noncapillary, it does not absorb any moisture from the air. Moisture has no effect on the stability of the products. Water absorption test certificate conducted under BS 2972 : section 12 and ASTM 209 are available on request. Chemical Neutrality: Chemically neutral with a ph value of 7.3 when tested in accordance with BS 2972 : Section 22 and ASTMC 871. It will neither cause nor promote corrosion. It meets the requirements of the standard specification for use over austenitic stainless steel as per ASTM C 692 ( Corrosion test ) and ASTM C871 ( Chemical Analysis ). It contains low level of chlorides when tested in accordance with BS 2972 : Section 21 and ASTM C871. Biological properties: Rotproof, nonhygroscopic, will not sustain vermin and will not encourage growth of bacteria, mould or fungi. Packaging: Supplied in cardboard cartons and shrink wrapped polyethylene. Unit Price: For details on price our sales office can be contacted. Technical advice: For further details of information on technical data, specialist product information, applications, heat loss calculations or economic thickness, our sales office can be approached.

Preformed Pipe Sections Specification STANDARD CONFORMANCE ASTM C 547 " Standard Specification for Mineral Fiber Pipe Insulation" BS 3958 Part 4 "Specification for Bonded Preformed Mineral Wool Pipe Sections " ASTM C 795 "Standard Specification for Thermal Insulation for use in contact with austenitic stainless steel" Can be used to satisfy BS 5422 "Method for specifying thermal insulating materials for pipes, tanks, vessels, ductwork and equipment" PROPERTIES DENSITY LENGTH DIAMETER THICKNESS WEIGHT TEST METHOD ASTM C 302 BS 2972 Section 3 SERVICE TEMPERATURE ASTM C 447/ C 411 & DIN 52271 NON COMBUSTIBILITY BS 476 Part 4 & ASTM E 136 FIRE RESISTANCE BS 476 Part 20 & ASTM E 119 BURNING CHARACTERISTIC ASTM E 84 THERMAL CONDUCTIVITY ASTM C 335 & DIN 52613 ACOUSTICAL PROPERTIES BS 3638 / ISO 354 ASTM C 423 Sound Absorption COMPRESSION RESISTANCE ASTM C 165 CHEMICAL ANALYSIS CHLORIDE FLUORIDE PH CORROSION TEST ASTM C 871 BS 2972 Section 21 AGIQ135 ASTM C 692 (Preproduction Corrosion Test) SHOT CONTENT ASTM C 1335 / BS 2972 SECTION 14 WATER ABSORPTION ASTM C 209 SECTION 14 / BS 2972 SECTION 12 WATER VAPOUR SORPTION WATER VAPOUR TRANSMISSION ASTM C 1104 / C 1104 M ASTM E 96/ E 96M ODOR EMISSION ASTM C 1304 LINEAR SHRINKAGE ASTM C 356

Rockwool Semi Rigid Slabs Rockwool semi rigid slabs are designed for the thermal and acoustic insulation or slightly curved surfaces operating at temperatures up to 750.C. These semirigid slabs are produced from long, noncombustible resin bonded fibers. The slabs are easy to cut, fit and handle. The robust fibers in the slabs combine high levels of thermal efficiency and acoustic absorption. Facings: Code C Description Black ceiling veil A.1 Aluminium foil (Fire resistant). A2 Aluminium reinforced in one direction. A.3 Aluminium reinforced in two directions. G Fiber glass veil. P K Polyethylene sheet. Kraft paper Applications: Designed for a wide range of applications, at both high and low service temperatures. it can be used on flat or slightly curved surfaced for thermal and acoustic insulation.they are also suitable for thermal insulation of ducts, tanks large vessels, cavity walls, curtain walls and sandwich panels. Standard Delivery: Available in densities of 30 to 60, in standard widths of 500mm and 600mm and lengths of 1000 mm and 1200 mm. Thickness are available from 30 to 100 mm. other sizes are available upon request. Compatibility: Compatible with all forms of material with which it is likely to come in contact in normal industrial and building applications. Thermal Conductivity: Mean Temp C kvalue W/mk 30 kvalue W/mk 60 50 0.047 0.039 100 0.059 0.046 150 0.078 0.060 200 0.098 0.071 250 0.126 0.088 300 0.108 350 0.126

Thermal conductivity is the main product property of thermal insulation material and products show remarkably low thermal conductivity values. Typical figures are shown below as tested in accordance with BS 874 : 1986. Service Temperature: Rockwool slabs when tested in accordance with DIN 52271 can withstand temperatures up to 750'C. Fire Safety: Non combustible when tested in accordance with BS 76 : Part 4 : 1970. Acoustical Properties: Typical sound absorption figures are shown below in accordance with BS 3638 & ISO 0354: Hz 30 60 125 0.22 0.22 250 0.60 0,63 500 0.86 0.90 1000 0.92 0.98 2000 0.99 1.05 4000 0.98 0.99 Moisture: Water repellent nonhygroscopic and noncapillary, it does not absorb any moisture from air nor does moisture have any effect on the stability of the slabs. Water absorption test certificate (partial immersion) conducted under BS 2972 : Section 12 are available upon request. Chemical Neutrality: Chemically neutral with ph value of 7.3 when tested in accordance with BS 2972 Section 22. It will neither cause nor promote corrosion. it meets the requirements of the standard specification for use over austenitic stainless steel as per ASTM c692 (Corrosion test) and ASTM C 871 (Chemical analysis). It contains low level of chlorides when tested in accordance with BS 2972 : Section 21. Biological properties: Rotproof, nonhygroscopic, will not sustain vermin and will not encourage growth of bacteria, mould or fungi. Packaging: Supplied in shrink wrapped polyethylene. Unit Price: For details on price our sales office can be contacted. Technical advice: For further details of information on technical data, specialist product information, applications, heat loss calculations or economic thickness, our sales office can be approached.

Rockwool Rigid Slabs Fujairah Rockwool rigid slabs to conforming to ASTMC 612 and equivalent BS39585 are designed for thermal and acoustic insulation of flat or slightly curved surfaces operating at temperatures up to 750º C. These semirigid slabs are produced from long, noncombustible resin bonded fibers with excellent load bearing characteristics. They are easy to cut, fit and handle. The robust fibers combine high levels of thermal efficiency and acoustic absorption. Facings: Code Description C Black ceiling veil A.1 Aluminium foil (Fire resistant). A2 Aluminium reinforced in one direction. A.3 Aluminium reinforced in two directions. Types: Code SXXX S2XX Class O S22X Class O S2XX S22X SZXX SG4X Description Slab without facing Slab with Aluminium foil (Fire resistant) on one side Slab with Aluminium foil (Fire resistant) facing on both sides Slab with Aluminium foil reinforced on one side Slab with Aluminium foil reinforced on both sides Slab Sealed in Polyethylene bag Slab with Black ceiling veil on one side Applications: Designed for a wide range of applications at both high and low service temperatures. It can be used on both flat and slightly curved surfaces for thermal and acoustic insulation of ductings, ovens, vessels and other industrial equipment. Ideal for insulation of flat surfaces of furnaces, boilers and tank, It is also suited for fire protection of steel structures, insulation of bulk heads and ship decks. Standard Delivery: Available in wide range of densities from 70 to 140, in standard widths of 600 mm and lengths of 1000 and 1200 mm. Thickness are available from 30 to 120 mm. Other sizes are available on request.

Thermal Conductivity: Fujairah products show remarkably low thermal conductivity values with typical figures shown below as tested in accordance with BS 874, Equivalent ASTMC 177/C 518 and DIN 52612 standards. Mean Temp C kvalue W/mk 80 kvalue W/mk 100 kvalue W/mk 140 10 0.033 0.033 0.033 50 0.038 0.037 0.037 100 0.046 0.044 0.043 150 0.054 0.052 0.049 200 0.066 0.061 0.058 250 0.080 0.072 0.068 300 0.096 0.084 0.080 350 0.115 0.098 0.093 400 0.134 0.118 0.102 Service Temperature: Can withstand temperature up to 750 º C when tested in accordance with DIN 52271 and ASTMC 411 Fire Safety: Non combustible when tested in accordance with BS476 part 4 and ASTME 136. Class I, when tested in accordance with BS476 part 7 and ASTME 84. Fire Resistant with integrity up to 240 min. and insulation up to 196 min,when tested as per BS476 part 20. Acoustical Properties: Typical sound absorption figures are shown below in accordance with BS 3638 & ISO 0354: Hz 70 100 125 0.22 0.23 250 0.62 0.66 500 0.91 1.05 1000 1.00 1.07 2000 1.00 1.05 4000 0.98 0.97 Compatibility: Compatible with all forms of material with which it is likely to come in contact in normal industrial and building applications. Moisture: Waterrepellent, nonhygroscopic, noncapillary, and does not absorb any moisture from air, Moisture has no effect on stability of slabs. Water absorption test certificate conducted under BS 2972 : Section 12 and ASTMC 209 are available upon request.

Chemical Neutrality: Chemically neutral with a ph value of 7.3 when tested in accordance with BD 2972 : Section 22 and ASTMC871. It will neither cause nor promote corrosion. It meets the requirements of the standard specification for use over austenitic stainless steel as per ASTM C 692 ( Corrosion ) test and ASTM C 871 ( Chemical Analysis ). It contains low level of chlorides when tested in accordance with BS 2972: Section 21 and ASTMC 871. Biological properties: Rotproof, nonhygroscopic, will not sustain vermin and will not encourage growth of bacteria, mould or fungi. Physical properties: Asbestos free and shot content is very low when tested as per ASTM C 612 and BS2972 Packaging: Supplied in shrink wrapped polyethylene. Unit Price: For details on price our sales office can be contacted. Technical advice: For further details of information on technical data, specialist product information, applications, heat loss calculations or economic thickness, our sales office can be approached.

Rockwool High Density Slabs Fujairah Rockwool high density slabs conforming to ASTM C 612 and Equivalent BS 3958 5 are designed for the thermal and acoustic insulation of flat or slightly curved surfaces operating at temperatures up to 750 º C. These high density slabs are produced from long, non combustible fibers designed to bear high loads. They are easy to cut, fit and handle. The robust fibers combine high levels of thermal efficiency and acoustic absorption. Facings: Code Description C Black ceiling veil A.1 Aluminium foil (Fire resistant). A2 Aluminium reinforced in one direction. A.3 Aluminium reinforced in two directions. Types: Code SXXX S2XX Class O S22X Class O S2XX S22X SZXX SG4X Description Slab without facing Slab with Aluminium foil (Fire resistant) on one side Slab with Aluminium foil (Fire resistant) facing on both sides Slab with Aluminium foil reinforced on one side Slab with Aluminium foil reinforced on both sides Slab Sealed in Polyethylene bag Slab with Black ceiling veil on one side Applications: Designed for a wide range of applications at both high and low service temperatures, It is suitable for applications where high compressive strengths are required and where the insulation is subjected to mechanical loads and vibrations. They are ideal for traffic areas and ideal insulation for tank roofs.

Standard Delivery: Available in densities of 150 to 200, In standard widths of 600 mm and lengths of 1000 and 1200 mm. Thickness vary from 30 to 120 mm. Other sizes are available on request. Thermal Conductivity: Fujairah Products show remarkably low thermal conductivity values. Typical figures are shown below as tested in accordance with BS 874 : 1986, and equivalent ASTMC 177/C 518. (ISO 8302 / ISO 8301) Mean Temp C kvalue W/mk 160 kvalue W/mk 200 50 0.035 0.034 100 0.041 0.041 150 0.048 0.046 200 0.057 0.055 250 0.067 0.064 300 0.079 0.076 350 0.091 0.088 400 0.103 0.098 Service Temperature: Can withstand temperature up to 750 º C when tested in accordance with DIN 52271 and ASTMC 411. It can also withstand continuous temperatures up to 850 º C. Fire Safety: Non combustible when tested in accordance with BS476 part 4 and ASTME 136. Class I, when tested in accordance with BS476 part 7 and ASTME 84. Fire Resistant with integrity up to 240 min. and insulation up to 196 min,when tested as per BS476 part 20. Acoustical Properties: Typical sound absorption figures are shown in accordance with BS 3638 & ISO 0354. Hz 70 100 125 0.23 0.22 250 0.70 0.71 500 1.06 1.00 1000 1.07 1.00 2000 1.00 1.00 4000 0.96 0.92

Compatibility: Compatible with all forms of material with which it is likely to come in contact in normal industrial and building applications. Compression Resistance: % Compression load kpa 200 load kpa 160 1 6 4 2 12 8 3 18 12 4 24 16 5 30 20 Moisture: Waterrepellent, nonhygroscopic, noncapillary, and does not absorb any moisture from air, Moisture has no effect on stability of slabs. Water absorption test certificate conducted under BS 2972 : Section 12 and ASTMC 209 are available upon request. Chemical Neutrality: Chemically neutral with a ph value of 7.3 when tested in accordance with BD 2972 : Section 22 and ASTMC871. It will neither cause nor promote corrosion. It meets the requirements of the standard specification for use over austenitic stainless steel as per ASTM C 692 ( Corrosion ) test and ASTM C 871 ( Chemical Analysis ). It contains low level of chlorides when tested in accordance with BS 2972 : Section 21 and ASTMC 871. Biological properties: Rotproof, nonhygroscopic, will not sustain vermin and will not encourage growth of bacteria, mould or fungi. Physical properties: Asbestos free and shot content is very low when tested as per ASTM C 612 and BS2972 Packaging: Supplied in shrink wrapped polyethylene. Unit Price: For details on price our sales office can be contacted. Technical advice: For further details of information on technical data, specialist product information, applications, heat loss calculations or economic thickness, our sales office can be approached.

Semi Rigid, Rigid & High Density Slabs Specifications STANDARD CONFORMANCE ASTM C 612 "Standard Specification for Mineral Fiber Block and Board Thermal Insulation" BS 3958 Part 5 "Specification for bonded manmade mineral fiber slabs. ASTM C 795 "Standard Specification for Thermal Insulation for use in contact with austenitic stainless steel" Can be used to satisfy BS 5422 "Method for specifying thermal insulating materials for pipes, tanks, vessels, ductwork and equipment" PROPERTIES TEST METHOD DENSITY LENGTH WIDTH THICKNESS WEIGHT ASTM C 303 BS 2972 Section 3 SERVICE TEMPERATURE ASTM C 447/ C 411 & DIN 52271 NON COMBUSTIBILITY BS 476 Part 4 & ASTM E 136 FIRE RESISTANCE BS 476 Part 20 & ASTM E 119 BURNING CHARACTERISTIC ASTM E 84 THERMAL CONDUCTIVITY ASTM C 177 / C 518, ISO 8302/ISO 8301 EQUIVALENT TO BS 874, DIN 52612 ACOUSTICAL PROPERTIES BS 3638/ISO 354 ASTM C 423 Sound Absorption ASTM E 90 Sound Transmission Loss ASTM E 413 Sound Transmission Class COMPRESSION RESISTANCE ASTM C 165 CHEMICAL ANALYSIS CHLORIDE FLUORIDE PH CORROSION TEST ASTM C871 BS 2972 Section 21 AGIQ135 ASTM C 692 (Preproduction Corrosion Test) SHOT CONTENT ASTM C 1335 / BS 2972 SECTION 14 WATER ABSORPTION ASTM C 209 SECTION 14 / BS 2972 SECTION 12 WATER VAPOUR SORPTION WATER VAPOUR TRANSMISSION ASTM C 1104 / C 1104 M ASTM E 96/ E 96M ODOR EMISSION ASTM C 1304 LINEAR SHRINKAGE ASTM C 356 RIGIDITY AND FLEXIBILITY CLASSIFICATION ASTM C 1101 / 1101M

Rockwool Blankets Fujairah Rockwool Blanket conforming to ASTMC 553, C 592 and equivalent BS3958 part 3 is a lightly bonded insulating material available with or without facing. These products can be faced on one side or both sides to form a firm but flexible multipurpose insulating materials. Facings: Code Description A.1 Aluminium foil (Fire resistant). A2 Aluminium reinforced in one direction. A.3 Aluminium reinforced in two directions. w. Wiremesh Types: Code BXXX B2XX Class O B22X Class O B2XX B22X BWXX BWWX BWXX (S.S) BWWX (S.S) Description Blanket without facing Blanket with Aluminium foil (Fire resistant) facing on one side Blanket with Aluminium foil (Fire resistant) facing on both sides Blanket with Aluminium foil on one side Blanket with Aluminium foil on both sides Blanket with G.1. wire mesh support on one side Blanket with G.1. wire mesh support on both sides Blanket with stainless steel wire mesh 5upport on one side Blanket with stainless steel wire mesh support on both sides Applications: Highly recommended for use in the thermal insulation of large vessels, boilers, small machinery, equipment, ducts, flange, valves and plants operating at high temperatures. The Mattress is exceptionally suited for wrapping large curved surfaces or for cutting to fit over irregular shapes. Standard Delivery: Available in densities of 70 to 150 ; In standard widths of 1000mm and 1200mm; and 4000mm length. Thickness are available from 30 to 120mm; and 4000mm length. Thickness are available from 30 to 120mm. Other lengths and width sizes are available on request.

Thermal Conductivity: products show remarkably low thermal conductivity values. Typical figures are shown as tested in accordance with corresponding standards. Mean Temp C kvalue W/mk 80 kvalue W/mk 100 kvalue W/mk 128 50 0.038 0.037 0.034 100 0.044 0.043 0.042 150 0.052 0.051 0.050 200 0.063 0.060 0.058 250 0.077 0.072 0.070 300 0.092 0.085 0.081 350 0.110 0.100 0.094 400 0.130 0.118 0.102 Service Temperature: Has a service temperature of 750'C when tested in accordance with DIN 52271 and ASTMC 411 but can also be used at continuous operating temperatures up to 850'C. Fire Safety: Non combustible when tested in accordance with BS476 part4 and ASTM E 136. Class I, when tested in accordance with BS476 part 7,(ASTM E84). Fine resistance with integrity up to 240 min and insulation up to 196 min, when tested as per BS476, part 20. Acoustical Properties: Suitable for acoustical insulation as per BS3638 and ISO 0354. Compatibility: Compatible with all forms of material with which it is likely to come in contact in normal industrial and building application. Moisture: Water repellent, nonhygroscopic, noncapillary it does not absorb and moisture from air.water absorption test certificates conducted under BS 2972 : Section 12 ASTMC 209. Chemical Neutrality: Chemical neutral with a ph value of 7.3 when tested in accordance with BS 2972 : Section 22 and ASTMC871. It will neither cause nor promote corrosion. It meets the requirements of the standard specification from use over austenitic stainless steel when measured according to standard modes ASTM C 692 Corrosion test and ASTM C871 (Chemical Analysis). It contains low level of chlorides of 6.5 PPM when tested in accordance with BS 2972; Section 21 and ASTMC 871. Biological properties: Rotproof, nonhygroscopic, will not sustain vermin and will not encourage growth of bacteria, mould or fungi. Unit Price: For details on price our sales office can be contacted. Technical advice: For further details of information on technical data, specialist product information, applications, heat loss calculations or economic thickness, our sales office can be approached.

Fujairah Rockwool Duct wrap Rockwool Duct wrap is a low density flexible mattress faced with reinforced aluminum foil on one side Applications: Designed for thermal and acoustic insulation of various applications such as duct and cladding or other equipment in heating, ventilating and airconditioning applications Care should be taken during installation to see all lap and joints should be securely sealed to avoid vapor leaks. Service Temperature: Has a service temperature of 750º C when tested in accordance with DIN 52271. Fire Safety: Non combustible when tested in accordance with BS 476: Part 4 : 1970 Standard Delivery: Available in densities of 30 to 50 ; in standard widths of 1000 and 1200 mm; and 5000 mm length. Thickness are available from 30 to 120 mm. Other lengths and width sizes are available upon request. Facing: Faced with reinforced aluminum foil. Thermal Conductivity: Mean Temp C value W/mk 40 50 0.039 100 0.047 150 0.058 200 0.070 250 0.085 Products shoe remarkably low thermal conductivity values. Typical figures are shown below as tested in accordance with BS 874 : 1986

Compatibility: Compatible with all other forms of material with which it is likely to come in contact in normal industrial and building applications. Biological Properties: Rotproof, nonhygroscopic, it will not sustain vermin and will not encourage growth of bacteria, mould or fungi. Moisture: Water repellent, nonhygroscopic, noncapillary it does not absorb any moisture from the air. Moisture has no effect on the stability of duct wrap. Water absorption test certificate(partial immersion) conducted under BS 2972 : Section 12 are available on request. Chemically Neutrality: Chemical neutral with a ph value of 7.3 when tested in accordance with BS 2972 : Section 22. It will neither cause nor promote corrosion. It meets the requirements of the standard specification for use over austenitic stainless steel as per ASTM C 692 (Corrosion test)and ASTM C 871 (Chemical Analysis).It contains low level of chlorides at 6.5 PPM when tested in accordance with BS 2972 : section 21. Packaging: Supplied in polyethylene bags. Unit Price: For details on price our sales office can be contacted. Technical advice: For further details of information on technical data, specialist product information, applications, heat loss calculations or economic thickness, our sales office can be approached.

STANDARD CONFORMANCE Blankets/Mattress Specification ASTM C 592" Standard Specification for Mineral Fiber Blanket Insulation and BlanketType Pipe Insulation (MetalMesh Covered) (Industrial Type)" ASTM C 553 "Specification for Mineral Fiber Blanket Thermal Insulation for Commercial and Industrial Applications" ASTM C 665 "Standard Specification for MineralFiber Blanket Thermal Insulation for Light Frame Construction and Manufactured Housing" ASTM C 795 "Standard Specification for Thermal Insulation for use in contact with austenitic stainless steel" BS 3958 Part 3 "British standard specification for Thermal Insulating Materials Part 3 Metal Mesh faced manmade mineral fibre mattresses" BS 5803 Part 1 "Specification for manmade mineral fibre Thermal Insulation Mats" Can be used to satisfy BS 5422 "Method for specifying thermal insulating materials for pipes, tanks, vessels, ductwork and equipment" PROPERTIES TEST METHOD DENSITY LENGTH WIDTH THICKNESS WEIGHT ASTM C 167 BS 2972 Section 3 SERVICE TEMPERATURE ASTM C 447/ C 411 & DIN 52271 NON COMBUSTIBILITY BS 476 Part 4 & ASTM E 136 FIRE RESISTANCE BS 476 Part 20 & ASTM E 119 BURNING CHARACTERISTIC ASTM E 84 THERMAL CONDUCTIVITY ASTM C 177 / C 518, ISO 8302/ISO 8301 EQUIVALENT TO BS 874, DIN 52612 ACOUSTICAL PROPERTIES BS 3638/ISO 354 ASTM C 423 Sound Absorption ASTM E 90 Sound Transmission Loss ASTM E 413 Sound Transmission Class COMPRESSION RESISTANCE ASTM C 165 CHEMICAL ANALYSIS CHLORIDE FLUORIDE PH ASTM C 871 BS 2972 Section 21 AGIQ135 CORROSION TEST ASTM C 692 (Preproduction Corrosion Test) SHOT CONTENT ASTM C 1335 / BS 2972 SECTION 14 WATER ABSORPTION ASTM C 209 SECTION 14 / BS 2972 SECTION 12 WATER VAPOUR SORPTION WATER VAPOUR TRANSMISSION ASTM C 1104/ C 1104M ASTM E 96/ E 96M ODOR EMISSION ASTM C 1304 LINEAR SHRINKAGE ASTM C 356 RIGIDITY AND FLEXIBILITY CLASSIFICATION ASTM C 1101 /C 1101M

Rockwool Fire Protection Boards Rockwool fire protection boards are manufactured from mineral boards to achieve maximum fire protection while at the same time has only the lightest possible weight. It is made with noncombustible mineral wool to achieve the maximum compression behavior. Advantages: With excellent thermal acoustic and fire insulation properties, fujairah rockwool fire protection boards are noncombustible, chemically inert, water resistant, vermin and rust proof and even resists high temperatures. easy to handle and maintenancefree these products are extremely cost effective. Dimensions: Available in L X W : 1200 * 600 of thickness 25, 40, 50 and 75 mm. Other dimensions can also be supplied on request. Facings: Supplied plain or foil faced for concealed use Compression Resistance: Have 10 % deformation at 200 KPa. Service Temperature: Can be used in continuous service at temperatures up to 750 º C without melting, and withstand temperatures up to 1000º C without melting. Fire Safety: NNon Combustible when tested in accordance with ISO 1182. Moisture: Impregnated Rockwool products are water repellent. Corrosion: Since Fujairah rockwool fire protection boards are made practically nonalkaline materials, It does not react chemically and consequently does not promote corrosion. Environment: No Cfcs or HCFCs are used in the manufacturing of Rockwool products. Quality Assurance: Well Established quality control system ensures strict quality controls. Standards: Noncombustible and nonspreading as per BS 476: Part 4 and 8.