WHITE PAPER ANSI/TIA-606-B



Similar documents
ANSI/TIA/EIA-606. Administration Standard for the Telecommunications Infrastructure of Commercial Buildings

Data Center Standards Making Progress on Many Fronts. Jonathan Jew J&M Consultants, Inc

Telecommunications Infrastructure Standard for Data Centers ANSI/TIA-942

ANSI/TIA-942 Telecommunications Infrastructure Standards for Data Centers

Telecommunications Infrastructure Standard for Data Centers Tutorial

ANSI/TIA-942 Telecommunications Infrastructure Standard for Data Centers

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

DIVISION 27 COMMUNICATIONS. A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).

TIA-942 Data Centre Standards Overview WHITE PAPER

A N S I/T I A/EIA 606A

Standards. 5 ANSI/TIA/EIA-569-A (CSA T530)

AMP NETCONNECT Data Center Cabling Solutions

SECTION TELECOMMUNICATION ROOMS

Dat Da a t Cen t Cen er t St andar St d andar s d R o R undup o BICSI, TIA, CENELEC CENELE, ISO Steve Kepekci, RCDD

InstaPATCH Cu Cabling Solutions for Data Centers

ANSI/TIA/EIA A A Revisited. Residential Telecommunications Cabling Standard (Draft 6/22/99) Larry L. Hamlin, RCDD

Network Design. Yiannos Mylonas

TIA 569 Standards Update Pathways & Spaces. Ignacio Diaz, RCDD April 25, 2012

TCTC Cabling Specifications

Innovation. Volition Network Solutions. Leading the way in Network Migration through Innovative Connectivity Solutions. 3M Telecommunications

Structured Wiring Specifications ERAU Daytona Beach Campus (Dec )

ADC s Data Center Optical Distribution Frame: The Data Center s Main Cross-Connect WHITE PAPER

Structured Cabling Statement of Work

NUIG Campus Network - Structured Cabling System Standards Information s Solutions & Services (ISS)

DEPARTMENTAL REGULATION

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS

Telecommunications Systems Narrative Page 1 The Engineering Enterprise

Data Center Topology Guide

This presentation to be used in conjunction with:

Migration Strategy for 40G and 100G Ethernet over Multimode Fiber

Running 1000BASE-T Gigabit Ethernet over Copper Cabling 30 March 1999 Colin Mick/The Mick Group with Bruce Tolley/3Com and Willem Wery/Intel

Scope: Communications and Electronic Systems addressed in this section include:

Security & Surveillance Cabling Systems

Data Center Optimization: Component Choice. Innovative Design. Enabling Infrastructure

UT Southwestern Medical Center Information Resources Cable Installation Standard

DESIGN GUIDELINES. Local Area Network

Data Centre & Enterprise Solutions. RapidNet

Minimum Standards for Data/Voice Infrastructure in New Building Construction

Structured and Point to Point Network Cabling for Industrial Automation

DATA CENTER NETWORK INFRASTRUCTURE. Cable and Connectivity for the Most Demanding Networks. BerkTekLevitonTechnologies.com

Maintaining Proper Polarity for Modular Pre-terminated Fiber Systems. Rudolph A. Montgelas Fiber Optic Senior Product Manager Ortronics/Legrand

TC Grounding and Bonding for Telecommunications Systems

Fiber Plant Design Considerations for Active DAS Mike Brownson VP DAS Technical Solutions Hutton Communications

SYSTIMAX SCS PowerSum and GigaSPEED XL Cabling Installation Guidelines

Data Center Design Considerations

SECTION COMMUNICATIONS OPTICAL FIBER OSP CABLING

Multiple Solutions for Connecting Multiple Dwelling Units (MDUs) WHITE PAPER

Building Telecommunications Infrastructure Requirements

How To Write An Infrastructural Standard For Data Center Infrastructure

Data Center Design for 40/100G

Managing High-Density Fiber in the Data Center: Three Real-World Case Studies

What is a Datacenter?

Section Grounding and Bonding for Communications

ATTACHMENT F 050R CABLE AND WIRING SERVICES FUNCTIONAL AREA I PRICE PROPOSAL FORM Amendment 6

Cabling Requirements for the District of Columbia on behalf of the Criminal Justice Coordinating Council

CommScope Intelligent Building Infrastructure Solutions (IBIS)

Category 6 Solutions. 4. Category 6 Solutions. 09/ IN TrueNet Structured Cabling. Introduction Cable Patch Panels... 4.

Implementing Fast Ethernet

Cat 5, 6 or 7? Standards. Background. A University Standard for Structured Wiring. Network Points Installed. British Standards.

ADC-APC Integrated Cisco Data Center Solutions

Policy Title-Aquia Data Center Operational Policy & Procedure. Policy ID - TSD-ADC001. Version - Version: 1.0. Supersedes Version 1.

The Need for Low-Loss Multifiber Connectivity

ANSI/TIA/EIA A, Commercial Building Telecommunications Cabling Standard.

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation

ADC KRONE s Data Centre Optical Distribution Frame: The Data Centre s Main Cross-Connect WHITE PAPER

A. All equipment and materials used shall be standard components that are regularly manufactured and used in the manufacturer s system.

The Three Principles of Data Center Infrastructure Design WHITE PAPER

TELECOMMUNICATIONS STRUCTURED CABLING GUIDELINES AND SPECIFICATIONS. University of Chicago IT Services Infrastructure Services October 2011

Design Guide. Universal Connectivity Grid. SYSTIMAX Solutions from CommScope

1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:

Zone Distribution in the Data Center

Data Center Network Infrastructure The Smart Choice For Your Data Center

Cabling and Building Infrastructure for Technology

21 st Century Campus Network Responsibility Matrix 5/26/10

FTE Cabling Best Practices Author: Todd Bill, RCDD/NTS

Design Guide. SYSTIMAX GigaSPEED X10D Solution Design and Installation Guidelines. June 2015

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

Intelligent Cable Management Systems

IT Cabling Solutions

Network Topologies and Distances

Terminating 25-Pair Cable and 4-Pair Cross Connects

Migration to 40/100G in the Data Center with OM3 and OM4 Optical Connectivity

FITNESS FACILITY WIRING SPECIFICATIONS. NETPULSE Inc rd Street San Francisco, CA Phone:

Data Center Solutions Guide. Solutions to Support, Protect, Enclose and Connect Data Center Equipment and Infrastructure

Table of Contents. Fiber Trunking 2. Copper Trunking 5. H-Series Enclosures 6. H-Series Mods/Adapter Panels 7. RSD Enclosures 8

Part 1: General Requirements TELECOMMUNICATIONS INDUSTRY ASSOCIATION

InstaPATCH ZERO Solution Guide

Corning Cable Systems Optical Cabling Solutions for Brocade

IT&T Infrastructure Standards

Things You Must Know About Gigabit Ethernet 1. Understanding Gigabit Ethernet

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

The Optical Fiber Ribbon Solution for the 10G to 40/100G Migration

Rack & Stack 123 TM. Enterprise Education Government Telecommunications Service Providers Tel:

ABOUT ANIXTER UNIVERSITY

C6 A modul and C6 A modul K. The new connection system for all applications of course with Cat.6 A

ADC Structured Cabling Solutions

Trends and Standards in LAN Cabling Systems Intelligent Buildings

Transcription:

WHITE PAPER ANSI/TIA-606-B

BACKGROUND American National Standards Institute (ANSI) Telecommunications Industry Association (TIA) Electrical Industries Alliance (EIA) International Standards Organization (ISO) International Electrotechnical Commission (IEC) ANSI/TIA-606-B is designed to be a generic labeling standard that applies to all types of premises. The standard is backward compatible with the legacy ANSI/TIA/EIA-606-A Addendum 1 and is compatible with the international standard ISO/IEC TR14763-2-1 identifiers. The original TIA-606-A was designed to identify and record the general administration, but did not address the specific needs of the data center design and installation. TIA-606-A was just reaffirmed back in 2007. The TIA-606-A Addendum 1 was published in 2008. The addendum reconciled the 606-A with the TIA s 942 data center standard. The current 606-A did not really consider data centers and the 942 did not consider administration. The two concepts came together in Addendum 1 to the 606-A. The development of the ANSI/TIA-606-B combined the TIA-606-A and the Addendum 1 while harmonizing with the requirements of the ISO/IEC TR14763-2-1. Labeling is a key factor in the installation and maintenance of an efficient and professional installation. The 606 standard continues to expand and address how and where to identify key components of Information Transport System (ITS). The new 606-B standard not only services the data center, but also commercial, residential, industrial and healthcare facilities. It now establishes guidelines for owners, end users, manufacturers, consultants, contractors, designers, installers, and facilities administrators involved in the administration of the telecommunications infrastructure. In addition, by harmonizing with ISO/IEC TR14763-2-1, the updated standard can be implemented internationally. The new standard is meant to increase the value of the system owner s investment by reducing labor costs associated with maintaining complex infrastructure systems, which results in extending the useful economic life of the system and by providing effective service to the users in a variety of industries, markets and international countries. 2

CHANGES FROM THE LAST REVISION 1. Adopts identification scheme specified in TIA-606-A Addendum 1. 2. Allows existing TIA-606-A identifier formats to continue to be used where they are already in use. NOTE: An identifier is simply the printed text that will appear on a label as related to the standard. 3. Harmonized with ISO/IEC 14763-2-1. 4. Creates new identification format for Cabling Subsystem 1 link identifiers (Horizontal links), Cabling Subsystem 2 and 3 links (Backbone cables) as well as telecommunications outlets, equipment outlets, splices, consolidation points and outdoor telecommunication spaces. NOTE: In order to be generic to all types of premises, terminology was adopted from the TIA-568-C.O. standard in which Cabling Subsystem 1 is now what was commonly referred to as the Horizontal Link. The (1) does not mean anything in particular except to differentiate Cabling Subsystem 1 links from Cabling Subsystem 2 and 3 links which we commonly referred to as Cross Connects or Backbone cables. Campus cabling has its own cabling separate from the cabling subsystem 2 and 3 links, which are the 2 layers of backbone cabling allowed in premises cabling. The standard allows one level of cross connection in Cabling Subsystem 1 and two levels of cross connection in Cable Subsystem 2 and 3 cabling. Clause 10.2.1 The language also makes the standard more generic in that it not only can service the data center, but can also service commercial, residential, industrial and medical facilities. 5. Extends administration to all inter-building telecommunications cabling. 6. Creates new identifiers for telecommunications outlets, equipment outlets, splices, consolidation points and outdoor telecommunication spaces (maintenance holes, pedestals, hand holes, etc.). 7. Administers Cabling Subsystem 2 and 3 links by pair groups, corresponding to ports (pairs, strands and grouping identifiers) rather than copper pairs or single fibers. See clause 6.1.2. 8. Administration of grounding and bonding systems beyond the TMGB and TGB. 9. Provides information on implementing automated infrastructure management systems. 3

THE BASICS CLASSES The standard still breaks out the criterion by classes of administration. CLASS 1 = Locations served by a single Equipment Room (ER) This ER is the only Telecommunications Space (TS) administered whereas there are no Telecommunication Rooms (TRs) and no Cabling Subsystem 2 and 3 cabling or outside plant cabling systems to administer. CLASS 2 = Fulfils the administration needs of a single building that are served by multiple Telecommunications Room (TR)s with one or more TR s within a single building. This includes all the elements of a class 1 system plus identifiers for Cabling Subsystem 2 and 3 cabling, multi-element bonding and grounding systems and fire stopping. CLASS 3 = Serves a campus environment with multiple buildings and building pathways, spaces, and outside plant elements. CLASS 4 = Attends the needs of a multi-site (multi-campus) administration. There are slight differences in requirements depending on what level is administered. In a Class 1 system, for example, the floor and room number do not need to be identified since there is only one room to manage. Obviously, as the complexity of the system increases, additional identifiers are needed. In Class 3 and 4 systems there are added requirements, such as building and campus identifiers, outside plant and inter-campus elements such as wide area network connections. The basic premise of the TIA-606-B compliant data center implementation is actually very simple and can be broken down using a few common examples. A typical patch panel and port identifier might be as follows: 1A.AD02-40:02 1A. = Floor 1, room A AD02 = The grid location within the data center for a particular rack or cabinet -40 = A patch panel located 40 rack units from the bottom of that rack or cabinet :02 = A specific port within the patch panel located at AD02-40. (This can also be a range of ports 01-24 as example) Optionally, we can remove the space location to the front of this identifier. If we are on floor 1, space A, and this is the only space, there is no need to include that portion on the printed identifier. The actual printed identifier might look as follows: AD02-40:02 Since we are harmonizing to the ISO/IEC TR 14763-2-1, we can optionally add a + sign which specifies that the next portion of the identifier is a location aspect. The + sign only needs to appear in the records section and not on the actual label. +AD02-40:02 An = in front of an identifier specifies a function aspect (Example: = XO for telecommunications outlet). 4

SPACE LABELING 1A = Floor 1, Space A, which is a alpha-numeric sequence that can be edited to suit the needs of the installation. Example: 3TRA would represent Telecom Room A on the third floor. An example of an ISO/IEC TR 14763-2-1 compatible format is: +3TRA. CABINET AND RACK IDENTIFIERS The standard recommends the use of GRID COORDINATES to distinguish the rack or cabinet in a space. In rooms that have access floor systems, recognition for the space shall employ the access floor grid identification scheme using alpha and numeric characters to mark the X and Y coordinates within the space. X COORDINATE AA AB AC AD AE AF AG AH AI AJ AK AL AM AN AO AP AQ AR AS AT AU AV AW AX AY AZ BA BB 01 02 03 04 05 06 07 08 09 10 11 12 13 Y COORDINATE So, a rack located at grid coordinates AD02, would be marked as ADO2. Typically, the label is placed on the top and bottom, front and rear of the rack or cabinet using machine printed labels. Where grid coordinates are not used, the racks can be marked by row and rack number. 5

PATCH PANEL IDENTIFIERS Within each rack, there will be patch panels. The patch panels shall be labeled with the identifier of the patch panels at the far end of the cables, if practical. These should be marked using rack units from the bottom of the cabinet. Since the floor/space marking is optional in a Class 2 system, the rack and panels can be marked by simply combining the grid coordinates of the rack with the rack units of the panels within that rack. A patch panel 35 rack units from the bottom of a rack located at grid coordinates AD02 would be identified as AD02-35. Rack unit position from bottom of usable space in cabinet or rack 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 Fiber Patch Panel Fiber Patch Panel Panel AD02-45 Panel AD02-41 Panel AD02-35 Panel AD02-31 Panel AD02-27 Panel AD02-23 Panel AD02-19 Panel AD02-15 Panel AD02-11 Panel AD02-07 NOTE: The standard also allows the marking of panels and sub-panels using alpha characters starting with A and excluding I, O and Q as outlined in sections 5.1.3.1.1 and 5.1.4.1. 6

PATCH PANEL PORT IDENTIFIERS TIA PN-606-B, (to be published as The patch panels should be labeled with the identifier of the patch panels at the far end of the cables, if practical. Each port, the first port or the last port, or the last of each subpanel shall be labeled. Patch panel labels shall contain the patch panel identifier. Where space permits, the patch panel also should have labels to specify the classification at the far end ports using this format. Each panel will ANSI/TIA-606-B) have a series of ports that need to be acknowledged. 863 864 865 866 12 UTP cables to the patch panel 42U Thus, from a typical the bottom patch panel/port of cabinet identifier AG06, on ports a set 01-12. of six ports within the patch In figure 10, the labels below each grouppanel of six might ports be includes marked as: the local and far-end patch panel and port identifiers. AD02-35 p 01-06 to AG03-35 p 01-06 This can be interpreted as the near end set of six port as being located in a patch panel 35 rack units from the bottom of rack or cabinet at grid location AD02 and these ports are going to the far-end set of six ports located in a patch panel 35 rack units from the bottom of rack or cabinet at grid location AG03. 867 868 869 870 871 872 873 NOTE: The near end room name and near end patch panel identifier can be Figure 10 Labeling example omitted for since UTPthis patch information panelis with implicit label and fields inferred from the required cabinet/ rack and patch panel labels. See section 5.1.3.1.3.1. The far end room name Figure 11 provides an example of labeling may for also a UTP be omitted patchif panel the far-end that patch does panel not have is in the a same room. This means manufacturer-provided label field for thethat patch the panel length identifier. of the identifier can be truncated to save space yet keep the format intuitive to the user. Example: One could shorten the example above to p 01-06 To AG03-35 p 01-06 874 875 876 877 878 879 880 881 Patch panels that support Cabling Subsystems 2 or 3 should indicate the name of the space; Main Distribution Area (MDA), Intermediate Distribution Area (IDA), Horizontal Distribution Area (HDA) or TR to which the cables run. Section 5.1.3.1.3.1. Figure 11 Labeling example for UTP patch panel without patch panel ID label fields Ports 01-06 to HDA01 AJ17-45 Ports 01-06 5.1.3.1.3.3 Optical fiber patch panels Section 5.1.4.4. All ports on patch panels and all positions on termination blocks Figure 12 and figure 13 show two ways of labeling a patch panel using or ignoring subpanels. shall be labeled with the corresponding port number or position number and In figure 12, the patch panel has subpanels, but they are ignored for purposes of numbering ports. optionally with additional identifier fields as practical. All subpanels shall be labeled with their subpanel identifier. An example of a sub-panel identifier is usually indicated by an alpha character: 7

Certain applications may provide electrical power in addition to data transmission over balanced twisted pair cables. Visual identification of ports with power MAY be accomplished through the use of this symbol. Ports A1-A6 & B1-B6 to AG10-B Ports 01-12 Ports A1-A6 = Sub panel A, ports A1-A6 Ports B1-B6 = Sub panel B, ports A1-A6 AG10-B = Sub panel B in rack at grid location AG10 Ports 01-12 = Ports 1 to 12 in sub panel B SPECIALIZED APPLICATIONS The new standard does address unusual and constantly changing circumstances. As an example from section 5.1.3.1.1, several manufacturers have come out with cabinets that use zero rack mount space by incorporating vertical rails in the cabinet to save space. In short, additional patch panels reside on either side of the cabinet in a vertical position. In this case, how does one identify these vertical patch panels? A simple way to mark the vertical panels is to use rack units combined with an alpha character for location within the rack or cabinet. The TIA-606-B now designates an additional alpha letter indicating the side as A, B, C, D, or F, L, R, B (Front, Left, Right, Back) as examples. This can be used when Rack Units (RU) are designated. The user can then name the horizontal and vertical patch panels by rack unit. The rack unit of the vertical patch panel is determined by the rack unit location, of the height of the top of the vertically mounted patch (by height at the top). A separate alpha designation for Right (R) or Left (L) to distinguish the vertical patch panels as being either on the left or right side of the cabinet. EXAMPLE: AG09-L35:01-06 In this case, the credential is describing a patch panel at 35 rack units from the bottom of the rack, on the left side of the cabinet, at grid location AG09, ports 1 to 6. Using pre-terminated copper or fiber solutions, Zero U, high density cabinets can allow additional ports where you need them and aligns connectivity with the servers. This allows for moves, adds, and changes without interrupting rack mounted equipment in a fully populated cabinet. This is a new trend in cabinet management to maximize data center real estate and the new TIA-606-B standard is flexible enough to allow proper identification of these vertical panels. 8

CABLING SUBSYSTEM 1 LINK / HORIZONTAL LINK IDENTIFIERS The main focus of the 606-B standard is to be able to track the ITS from the data center to the work area. Using the new format, a horizontal link identifier that terminates at both ends on panels within the same data center would be printed as follows: NEAR END = AG09-35:01 / AJ06-35:01 FAR END = AJ06-35:01 / AG09-35:01 If standing at rack location AG09, reading this near end cable identifier will describe both the near end and far end locations. AG09 = Rack or cabinet at grid location AG09 within the data center - 35 = Patch panel located 35 rack units from the bottom in rack AG09 :01 = Port 01 in patch panel located 35 rack units from the bottom of rack AG09 / = Separator for near end/far end location description AJ06 = Rack or cabinet at grid location AJ06 within the data center -35 = Patch panel located 35 rack units from the bottom in rack AJ06 :01 = Port 01 in patch panel located 35 rack units from the bottom of the rack in AJ06 The ISO/IEC TR14763-2-1 identifiers would appear as follows for a Cabling Subsystem 1 Link; AG09-35:01 / AJ06-35:01=W The W is the letter code for cables as specified in IEC 81346-2. NOTE: In commercial buildings, industrial premises, data centers and multi-tenant buildings, each individual telecommunications outlet or equipment outlet shall be labeled with the Cabling Subsystem 1 link identifier. The labeling SHALL appear on the connector, faceplate and Multi User Telecommunications Outlet Assembly (MUTOA) in a way that clearly identifies the individual connector associated with the particular identifier. Section 5.1.7.3. In sections 5.1.8.1 to 5.1.11.2 when using the Cabling Subsystem 1 link identifiers, it is optional to identify Equipment Outlets (EO s) and telecommunication outlets (TO s) by using a two letter code to identify the outlet. XO XC XL XSz = Equipment room outlets = Consolidation points = Zoned Distribution Areas (ZDA) ports = Splice where z is the appropriate distance along the cable of the splice from the termination point in the telecommunications room or HDA. An example of a Cabling Subsystem l link identifier using the option to identify the outlet might look as follows: AG09-35:01 / AJ06-35:01=XL:5 The port on the consolidation point may optionally be identified by a colon : and the port after the XL. Figure 4: Option B is using two MPO/MTP connectors side by side with 1 row of 12 9 array fibers on each connector.

GROUNDING AND BONDING The standard addresses grounding and bonding beyond the (Telecommunications Main Grounding Busbar) TMGB and (Telecommunications Grounding Busbar) TGB with the optional addition of the (Rack Grounding Busbar) RGB, (Mesh Bonding Network) MBN, (Bonding Conductor for Telecommunications) BCT, (Telecommunications Bonding Backbone) TBB, as well as being able to attach objects such as an identifier for a cabinet or rack or electrical panel as some common examples. See sections 5.1.12 to 5.2. A practical example might be a rack grounding Busbar identifier where you may have more than one Rack Grounding Busbar (RGB) in the cabinet rack or wall segment is shown below. 2A=RGB1 2A = Floor 2, Room A RGB = Rack Grounding Busbar #1 The standard also allows the addition of an identifier that identifies an object to which the bonding conductor is attached. This might include an electrical panel, a pathway, building steel, a cable tray or equipment such as a Local Area Network (LAN) switch. Typically this is the TIA-606-B identifier of the equipment. In this example, we add the grid location of the rack or cabinet to which the RGB is attached: 2A=RGB1/AJ05 2A = Floor 2, Room A RGB = Rack Grounding Busbar #1 AJ05 = Rack at grid location AJ05 which is the object attached to the RGB 10

BUILDING CABLING SUBSYSTEM 2 AND 3 CABLE IDENTIFIERS The backbone cabling is handled very similar to Cabling Subsystem 1 link identifiers explained earlier in this document. A typical identifier will include the identifier for the space at one end of the cable, the space terminating the other end of the cable and one or two alpha numeric characters to identify a single pair or port. 1A.AJ06-27:01 / 2A.AJ09-27:01 1A = Floor 1, Space A AJ06 = Rack or cabinet at grid location AJ06 27 = Patch panel located 27 rack units from the bottom of the frame :01 = Port 1 For Class 3 and 4 installations, the installer is just adding campus and building identifiers. Example of a backbone cable identifier: A-ENG-1A:AJ06-27:01-06 / B-ADM-1A.AJ09-27:01-06 A = Campus A ENG = Engineering Building B = Campus B ADM = Administration Building NOTE: Administration of Cabling Subsystem 2 and 3 identifiers is by pair groups or ports rather than copper pairs or single fibers. Each port or pair on a building Cabling Subsystem 2 and 3 cable shall have a unique identifier. Individual optical fibers and balanced pairs are typically color coded rather than individually marked. 11

FIRESTOPPING The TIA-606-B legacy format for marking a fire stop would be printed as follows: 2-FSL01(6) 2 = 2nd Floor -FSL = First Stop Location 01 = Location # (6) = 6 hour burn rating The comparable format for ISO/IEC 14763-2-1 would be printed as follows: SF02-2A/3A=U(3)=F SF02 = Building SF02 2A = Floor 2, space A / = Located between telecom rooms 2A and 3A 3A = Floor 3, space A =U = U following the equal sign specifies the element is a pathway (3) = Sleeve 3 F = Specified the element is a Fire stop location SPECIAL PURPOSE CABLE MANAGEMENT SOFTWARE The new ANSI/TIA-606-B standard also covers automated infrastructure management systems which may include technology used to detect and to record infrastructure changes (e.g. pre-printed serialized bar codes, human readable text, RFID chip technology and electrical continuity contacts. There are no specific labeling requirements and each can be labeled in a variety of ways that suit each installation, but should contain the records described in the 606-B. These specialized software programs should be able to directly generate the labels or be able to export data to other devices or labeling software that can generate the machine printed labels. Figure 5: Option C is using two MPO/MTP connectors stacked with 1 MPO/MTP connector on top of the other connector. This drawing shows Receiver on top and Transmitter on the bottom. 12

OUTSIDE PLANT AND PATHWAY IDENTIFIERS The new standard also addresses outside plant and pathways by identifying inter-building and outside plant pathways as well as entrance pathway identifiers. As an example, a maintenance hole, handholes, pedestal or outdoor cabinet might be identified as follows: LAX1-MH101(37.797413,-122.414925) The Maintenance Hole on campus LAX1 is located at Global Positioning System (GPS) coordinates 37.797413-122.414925. The use of GPS is optional and could be replaced site locations such as site MH12 which would represent Maintenance Hole 12 on campus LAX1. See section 9 under Optional Identifiers For Infrastructure Elements. LAX1-MH12 Termination Type Color Pantone # Typical Application ALTERNATE LABEL FORMATS Demarcation Point Network Connection Common Equipment Cabling Subsystem 3 Cabling Subsystem 2 Campus Inter-building Cabling Orange Green Purple White Gray Brown 150C 353C 264C 422C 465C Central Office Connection User Side of Central Office Connection Connection to PBX, Mainframe Computer, LAN, Multiplexer Terminations of Building Cabling Subsystem 3 Cable Connecting MC ot ICs Termination of Building Cabling Subsystem 2 Cable Connecting IC ot HCs Termination of Campus Inter-building Cable Between Buildings Section 4.6 allows the use of a direct link to an identifier within the records using a printed label with a short and simple numeric code or a machine readable label such as an RFID chip or a pre-printed barcode label. So, as example, in the record, the identifier for a particular port might be: A-ENG-1A:AJ06-27:01-06 / B-ADM-1A. AJ09-27:01-06 The actual label might simply be printed with the number 132, (in human readable text or barcode) but the number 132 is a direct link and cross reference to the detailed identifier (A-ENG-1A:AJ06-27:01-06 / B-ADM-1A.AJ09-27:01-06) in the actual database. This can reduce the number of characters required to print on the cable or equipment label. Cabling Subsystem 31 Blue 291C Terminations of Cabling Subsystem 1 Cable In TSs COLORS Miscellaneous Yellow 101C 10.2.2 Table 4 Colors Alarms, Security, or Energy Management Using colors is recommended, but not a requirement. Many smaller installers find it costly to stock and purchase many colors of labels in order to meet a requirement that might not fit their particular situation. The 606-B is not color dependent and allows the installer to fully identify without requiring the use of a color. If color is used, the installer should use the pantone color scheme as outlined in section 10.2.2, table 4. 13

RECORDS Most installers are aware of the cost of installing and maintaining an efficient and cost effective ITS. Labeling is crucial in this area. Yet, there is an aspect that is often neglected record keeping. Maintaining records of your ITS installation is the most valuable part of any labeled configuration. In the standard, you must link a record for each identifier that is printed on a label. If the records are complete and accurate and contain the recommended data as outlined in the labeling standard, the customer will have a well documented infrastructure that can be understood and managed by anyone responsible for making moves, adds or changes. So, the label is important, but if you do not attach the relevant data to that identifier, much of that value is lost. A database can be something as simple as an Excel spreadsheet. Each identifier makes up a row in the spreadsheet and each element associated with that identifier is recorded in the columns going across the database. As an example, each Cabling Subsystem 1 link (Horizontal link) record shall include the following: Example of spread-sheet implementation of class 1 administration system: horizontal link records sorted by building room number. Location of work area outlet connector Cabling Subsystem 1 link identifier. Outlet connector type (8 position, 110, SC or duplex as example) Cross connect hardware (Patch panel, T568B Cate 53, etc) Cable type (4pr. UTP, Cat 5e, plenum, or 2 strand 62.5/125 multi-mode, FDDI grade, riser) Cable length Service record of link It may also include any other data that the installer or customer feels is pertinent to the installation such a the color code of the outlet connectors, wiring scheme, Multiple User Telecommunications Outlet Assembly (MUTOA) Consolidation Point (CP) or Transition points. (It could be shown in the form of an Excel Spreadsheet like below) Horizontal Link Identifier Cable Type Building Location of Outlet Outlet Connector Type Color Code of Outlet Connector Other Outlet Connectors at this Location Wiring Scheme Horiz. Cable Length Service Record MUTOA CP Trans. Point 1A-W01 Cat 5e Plenum R111 8 Pos Mod Beige 1A-A01 1A-B01 568A 129ft Tested 4/22/01 No No No 1A-A01 Cat 5e Plenum R111 8 Pos Mod Orange 1A-W01 1A-B01 568A 127ft Tested 4/22/01 No No No 1A-B01 62.5/125, Two Strand, Plenum R111 SC Duplex Blue 1A-W01 1A-A01 N/A 128ft Tested 5/23/01 No No No 1A-W02 Cat 5e Plenum R112 8 Pos Mod Beige 1A-A02 1A-B02 568A 112ft Tested 4/22/01 No No No 1A-A02 Cat 5e Plenum R112 8 Pos Mod Orange 1A-W02 1A-B02 568A 112ft Tested 4/22/01 No No No 1A-B02 62.5/125, Two Strand, Plenum R112 SC Duplex Blue 1A-W02 1A-A02 N/A 113ft Tested 5/23/01 No No No 14

If the ITS is not efficient to administer, the cost of any mistakes far outweigh the initial cost of recording all the data initially at the time of installation. In the long run, the expense of not recording administration data can be very high. The outlay of testing and tracking cables can be expensive and can result in a backlog of cables that are abandoned in the plenum in lieu of simply pulling a new cable. Even an installation that appears intuitively simple, may grow over time and eventually become an unmanageable mess if the ITS is not recorded properly. The TIA-606-B standard is the culmination of years of work by many experts, installers, engineers and customers to make the best system possible. There are still elements that must be addressed, but it is a standard that is now having global attention. It is a paradigm that will continue to develop and change the way we think about administration and labeling. 15

About HellermannTyton HellermannTyton is a global manufacturer of identification, cable management and connectivity solutions for the commercial data, telecommunications, electrical, and industrial markets. HellermannTyton offers an integrated approach to design, operation, and delivery to optimize service and solutions for local and global customers. The company s engineered solutions and innovative products are designed and constructed to meet the strictest quality standards while delivering reliable implementation at the lowest cost. For more information, call HellermannTyton at 800.537.1512 or visit www.hellermann.tyton.com for published details. Author Todd Fries HellermannTyton North American Corporate Headquarters 7930 N. Faulkner Rd, PO Box 245017 Milwaukee, WI 53224-9517 Phone: (414) 355-1130, (800) 537-1512 Fax: (414) 355-7341, (800) 848-9866 email: corp@htamericas.com www.hellermann.tyton.com TS16949, ISO 9001, and ISO14001 Certified This information contained in the document represents the current view of HellermannTyton with respect to the subject matter contained herein as of the date of the publication. HellermannTyton makes no commitment to keep the information presented up to date and the facts in this document are subject to change without notice. As HellermannTyton must respond to the changing market conditions, HellermannTyton cannot guarantee the accuracy of any information presented after the date of the issuance. This document is presented for informational purposes only. All rights reserved. No part of these pages, either text or image may be used for any purpose other than personal use. Therefore, reproduction, modification, storage in a retrieval system or retransmission, in any form or by any means, electronic, mechanical or otherwise, for reasons other than personal use, is strictly prohibited without prior written permission. Copyright 2011, All rights reserved. May not be reproduced without the consent of HellermannTyton. HellermannTyton Corporation 16