Carlon Carflex Liquidtight Flexible Tubing



Similar documents
Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes

TMC CableReady Connectors For Jacketed Metal Clad Cable TMC For Non-Hazardous Locations

Tubing and Accessories

Raceway and Boxes for Electrical Systems Page 1 of 7

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Ocean Engineering Technical Data Sheet Stuffing Tubes

ANAMET Electrical, Inc. Worldwide Leader in Flexible Conduit Technology

Cable and Cord Reels. Section R. Cable and Cord Reels Index. Index

Carlon Bore-Gard and Boreable Multi-Gard Raceway

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

INSTALLATION & OPERATING INSTRUCTIONS

with installation dynafact boost GAUGE this manual is for use with systems

5800 Temperature Sensor Cable Assembly

C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S

DIRECTCONNECT SERVICE

POWERS Controls No. 4 Pneumatic Damper Actuator

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

4 Installation Requirements

Installation Instructions S

Quartzone Infrared Quartz Tube & Metal Sheathed Electric Heaters

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

Stainless Steel Single and Dual Circulation Kits

Installation Instructions

2006 JUDY SERVICE GUIDE

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

Installation Instructions

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

Terminal Cleaning and Protection

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

Mini USB and USB 2.0-IP67 Connector System

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

Generator DoCKInG StatIonS

8146/5 Series Breaker Panelboards

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

For exploded diagram and part number information, refer to the Spare Parts Catalog available on our website at

The MC Cable Revolution is Gaining Ground REMKE

EZ-Steer Assisted Steering System

HYDRAULIC LIFT TABLE CART 2200-LB.

AM/FM ANTENNA RELOCATION KIT

14 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN

Guidelines for Earthquake Bracing of Residential Water Heaters

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

758 Heavy-duty Ratchet Guy Wire Cutter

CEILING CASSETTE FAN COIL UNIT

Easy Tool Retracting System CMC-SR2159ER36

Scepter PVC Molded Junction Boxes

James M. Pleasants Company

Installation Instructions For Slider Casement Air Conditioners

Explosion proof enclosures

1. SAFETY RULES WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, MOUNT FAN TO OUTLET BOX MARKED "ACCEPTABLE FOR FAN SUPPORT".

16 April F Dodge Adjustable Track bar with Relocation Bracket 1

For exploded diagram and part number information, refer to the Spare Parts Catalog available on our website at

American National Standard. Fittings, Cast Metal Boxes, and Conduit Bodies for Conduit, Electrical Metallic Tubing, and Cable

Terminal Boxes Series 8146

POLARIS INSUL-TAP CONNECTORS FOR TWO WIRES & IN-LINE SPLICERS/REDUCERS

Lightweight, Heavy Duty

PRODUCT MANUAL - M090

Coyote popup features

OWNER S MANUAL Table Tennis Table Patent Pending

15/40/80CN Series Coreless Medium Pressure Filters

DETACHABLE WINDSHIELD AND DOCKING HARDWARE KIT

INSTALLATION INSTRUCTIONS FOR INTERNATIONAL 9000 SERIES ROOF TOP AIR CONDITIONERS

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

AM/FM ANTENNA KIT (TOUR-PAK MOUNT)

Top Commercial / Residential Electrical Requirements *

AMPSEAL* Automotive Plug Connector and Header Assembly

It's large enough to handle most welding job shop projects, yet small enough to make it a worth while home-workshop tool

MAST ARMS & POLES. Ornamental Pole Top & Bases

9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

INSTALLATION INSTRUCTIONS

VIPERFLEX ELECTRIC CABLE

! WARNING. Before using product, read and understand instructions.

RayClic Connection System Installation Instructions

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

ELECTRIC KNIFE SHARPENER

WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS

Navico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement

PACKAGED TERMINAL AIR CONDITIONER (PTAC) / PACKAGED TERMINAL HEAT PUMP (PTHP) AND ACCESSORY INSTALLATION INSTRUCTIONS

SCION tc COIL OVER SUSPENSION Preparation

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

VS CONTROL PACK INSTALLATION INSTRUCTIONS

BBWX1 Satellite Weather Receiver. Installation and Maintenance Guide

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

INSTALLATION INSTRUCTIONS HUSTLER 4-BTV, 5-BTV TRAP VERTICAL WARNING INSTALLATION OF THIS PRODUCT NEAR POWER LINES IS DANGEROUS

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Questions and Answers for Heating and A/C Contractors

Part Name/Description Part Number Quantity. Power Cable

Lighting Packages. 230 VAC Fluorescent Enclosure Light:

TRANS-05, Torque Tube Removal, Rebuilding, and Installation

Mueller. Pipe Repair Products. Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source.

Key Design Criteria for High Flex Cable Constructions By Mike Levesque, Dale S. Long, and Ron Crouch of C&M Corporation

Transcription:

Carlon Carflex Liquidtight Flexible Tubing Carflex Carflex X-Flex Fittings Cord Grips Pre-Wired Whips www.carlon.com 3

Carflex Liquidtight Flexible Conduit Carflex Liquidtight Flexible Nonmetallic Conduit provides superior wire protection in harsh, damp environments. Carflex Conduit is nonconductive, noncorrosive, and resistant to oil, acid, ozone, and alkaline. Carflex Conduit is strong and lightweight, and because it weighs 50% less than metallic systems, it s easy to handle, transport and install. Carflex is ideal for industrial, air conditioning, heating, and outdoor lighting applications. Nonconductive and noncorrosive Lightweight for easy handling, transportation, and installation Crush, abrasion, and strain resistant Provides superior wire protection Smooth interior ideal for pulling cable No jagged edges Maintains internal I.D. even in tight radius bends Type LFNC-B Resistant to oil, acid, ozone, and alkaline UL Listed for use as indicated in Article 356 of the 2002 NEC; and Section 12-1300 of the 2002 Canadian Electrical Code, Part 1. UL Listed for outdoor use UL Listed for sunlight resistant Trade sizes 1/2", 3/4", and 1" are UL Listed for direct bury Sequentially marked footage Suitable for use at conduit temperatures of 80 C dry, 60 C wet and 60 C oil resistant as required by section 15-6 of ANSI/NFPA 79-1985 and UL 1660. Note: Liquidtight flexible conduits, metallic and nonmetallic, in contrast to rigid PVC conduit and electrical nonmetallic tubing, does not have wire temperature limitations. Any temperature rated wire (for example, 90 wire) can be used as long as the temperature conditions marked on the conduit are not exceeded. UL Listed conduits that are not marked are limited to a maximum temperature of 60 C wet or dry. Applications Control and motor Air conditioning and heating Computer power distribution Machine tools Console wiring Transformer connections Outdoor lighting Custom Orders Available in black and gray. Consult factory for custom colors. Custom cut lengths available; consult factory for details. Coils Part Nom. Size Std. Ctn. Std. Ctn. No. (in.) Qty. (ft.) Wt. (lbs.) 15004-100 3/8" 100 11.70 15005-50 1/2" 50 6.50 15005-100* 1/2" 100 13.00 15005BK-100* 1/2" 100 13.00 15007-100* 3/4" 100 18.00 15008-100* 1" 100 28.00 15009-100 1-1/4" 100 37.60 15010-50 1-1/2" 50 22.55 15010-100 1-1/2" 100 47.80 15011-050 2" 50 34.10 Standard color Grey Reels Part Nom. Size Std. Ctn. Std. Ctn. No. (in.) Qty. (ft.) Wt. (lbs.) 15004-001 3/8" 1000 145.0 15005-001 1/2" 1000 157.0 15005BK-001 1/2" 1000 157.0 15007-001 3/4" 1000 212.0 15008-500 1" 500 155.0 15009-200 1-1/4" 200 100.0 15010-150 1-1/2" 150 95.7 15011-100 2" 100 94.6 Standard color Grey E79553 *Joint listed UL/CSA Approved product available 4 www.carlon.com

Carflex X-Flex Flexible Conduit Carflex X-Flex Extra Flexible Nonmetallic Conduit is ideal for applications requiring extra strength and flexibility such as robotics, and repetitive flexing arms. Carflex X-Flex is nonconductive, noncorrosive, and resistant to oil, acid, ozone, and alkaline. It s designed for use with standard Carflex fittings providing a complete nonmetallic system. Carflex X-Flex is lightweight for easier handling, transportation, and installation. Applications Extra strong and flexible to withstand repetitive motions Nonconductive and noncorrosive Resistant to oil, acid, ozone, and alkaline Lightweight for easy handling, transportation, and installation Crush, abrasion, and strain resistant Provides superior wire protection Smooth interior ideal for pulling cable No jagged edges Rated for continuous use at 60 C (140 F) ambient Repetitive Flexing Arms Robotics Machine Tools Automatic/Moving Machinery Control and motor Coils (Available in Black only) Part Nom. Size Std. Ctn. Std. Ctn. No. (in.) Qty. Wt. (lbs.) *15104-100 3/8" 100 9.09 *15105-100 1/2" 100 10.01 *15107-100 3/4" 100 13.91 *15108-100 1" 100 18.25 *15109-100 1-1/4" 100 27.65 *15110-100 1-1/2" 100 38.00 *15111-050 2" 50 24.22 E80040 Where noted by * LR88170 Where noted by www.carlon.com 5

Carflex Liquidtight Fittings Straight Fittings For use with Carflex conduit and Carflex X-Flex conduit Image 1 Image 2 Image 3 Image 4 Assembly Compression Nut Fitting Body Extended Threads Nitrile Rubber O-Ring Metal Locknut Assembly Compression Nut Sealing Ring Ferrule Fitting Body O Ring Plastic Locknut Nonconductive and Noncorrosive Resistant to oil, acid, ozone, and alkaline Easy to install Nitrile rubber O ring for a liquidtight termination Temperatures up to 225 F (107 C) Meets UL Standard 514B LT43C-CAR, LT43D-NEW, LT43E-NEW, LT43F LT43G, LT43H LT43J Part Size Std. Ctn. Std. Ctn. A B C D E Refer to No. (in.) Qty. Wt. (lbs.) (inches) (inches) (inches) (inches) (inches) Image LT43C 3/8 50 3.6.55.75 1.60 1.30 1.40 1, 2 LT43C-CAR 3/8 15 1.4.55.75 1.60 1.30 1.40 1, 2 LT43D-NEW 1/2 50 4.2.56.91 1.62 1.30 1.40 1, 2 LT43E-NEW 3/4 50 6.6.56.91 1.88 1.61 1.71 1, 2 LT43F 1 25 5.5.70 1.00 2.20 1.90 2.04 1, 2 LT43G 1-1/4 5 1.5.71 1.16 2.50 2.17 3, 4 LT43H 1-1/2 5 2.0.75 1.36 2.78 2.43 3, 4 LT43J 2 5 2.5 1.00 1.45 3.33 3, 4 6 www.carlon.com

Carflex Liquidtight Fittings 90 Fittings For use with Carflex conduit and Carflex X-Flex conduit Image 1 Image 2 Image 3 Image 4 Assembly Compression Nut Fitting Body Extended Threads Nitrile Rubber O-Ring Metal Locknut Assembly Compression Nut Sealing Ring Ferrule Fitting Body O Ring Plastic Locknut Nonconductive and Noncorrosive Resistant to oil, acid, ozone, and alkaline Easy to install Nitrile rubber O ring for a liquidtight termination Temperatures up to 225 F (107 C) Meets UL Standard 514B LT20C-CAR, LT20F-NEW LT20D-NEW, LT20E-NEW LT20G, LT20H, LT20J Part Size Std. Ctn. Std. Ctn. A B C D E F G Refer to No. (in.) Qty. Wt. (lbs.) (inches) (inches) (inches) (inches) (inches) (inches) (inches) Image LT20C 3/8 50 4.9.56 1.44 1.44 1.56 1.39 1.26 3, 4 LT20C-CAR 3/8 15 1.8.56 1.44 1.44 1.56 1.39 1.26 3, 4 LT20D-NEW 1/2 50 4.9.56 1.76 2.05 1.62 1.40 1.30 1.15 1, 2 LT20E-NEW 3/4 50 8.0.56 2.04 2.35 1.88 1.71 1.61 1.50 1, 2 LT20F 1 25 6.9.70 2.01 2.01 2.26 2.04 1.90 3, 4 LT20G 1-1/4 5 1.9.75 2.50 3.55 2.48 3, 4 LT20H 1-1/2 5 2.2.75 2.80 3.98 2.77 3, 4 LT20J 2 5 3.4.94 3.48 4.56 3.33 3, 4 www.carlon.com 7

Carflex One-Piece Liquidtight Fittings Unique Design The simple, one piece body design of the Carflex One Piece Liquidtight Nonmetallic Fitting requires no disassembly of components for installation. The system is so strong that there is no need for a compression nut. PVC Construction PVC construction of the fitting and locknut provides unparalleled protection from water, oil and dust. Totally nonmetallic, the system is nonconductive and will not corrode or rust. Temperatures up to 140 F (60 C) Straight Fittings LR201397 Part Trade Size Std. Ctn. Std. Ctn. A D E No. (in.) Qty. Wt. (lbs.) (inches) (inches) (inches) LN43DA 1/2-14 NPT 100 2.8 0.56 1.34 1.19 LN43EA 3/4-14 NPT 50 2.2 0.56 1.63 1.44 LN43FA 1-11 1 /2 NPT 25 3 0.69 1.99 1.75 LN43FA-CAR 1-11 1 /2 NPT 15 1 0.69 1.99 1.75 90 Fittings LR201397 Part Trade Size Std. Ctn. Std. Ctn. Thread A B C D E No. (in.) Qty. Wt. (lbs.) Size (inches) (inches) (inches) (inches) (inches) LN20DA 1/2-14 NPT 100 4.3 1/2-14 NPT 0.56 1.50 1.99 1.34 1.19 LN20EA 3/4-14 NPT 50 3.1 3/4-14 NPT 0.56 1.73 2.25 1.63 1.44 LN20FA 1-11 1 /2 NPT 25 3.2 1-11 1 /2 NPT 0.69 1.86 2.58 1.99 1.75 LN20FA-CAR 1-111/2 NPT 10 1 1-111/2 NPT 0.69 1.86 2.58 1.99 1.75 8 www.carlon.com

Straight Carlon Carflex Omni Connectors Available in sizes 3/8" through 1" conduit and tubing. All nylon construction resists salt water, weak acids, gasoline, alcohol, oil, grease and common solvents. No disassembly required. No threading of the conduit or tubing required to install. Complete Conduit/connector system is reusable. Suitable for indoor/outdoor use. Lower installed cost. Black connectors provided with nylon locknut. Body & Sealing Unit Locking Nut A C D E F G H Wrenching Part Part Clearance Max O.A. Thread Nut Wrenching Wrenching Std. No. No. Hole Length Length Thickness Flats Thickness Flats Ctn. Size Black Gray* Description in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) Qty. 3 /8" LT38 LT38G Straight L/T Fitting.875 (22.2) 2.000 (50.8).625 (15.9).250 (6.3) 1.328 (33.7).266 (6.7) 1.062 (26.9) 50 1 /2" LT50 LT50G Straight L/T Fitting.875 (22.2) 2.000 (50.8).625 (15.9).250 (6.3) 1.328 (33.7).266 (6.7) 1.062 (26.9) 50 3 /4" LT75 LT75G Straight L/T Fitting 1.109 (28.2) 2.031 (51.6).625 (15.9).250 (6.3) 1.562 (39.7).266 (6.7) 1.312 (33.3) 25 1" LT100 LT100G Straight L/T Fitting 1.375 (34.9) 2.250 (57.1).781 (19.8).250 (6.3) 1.875 (47.6).266 (6.7) 1.625 (41.3) 20 *Gray connectors provided with assembled o-ring and metal locknuts. Black connectors provided with nylon locknuts only. LR201397 Gray connectors provided with assembled O-ring and metal locknuts. Protection class IP 68 per DIN 40050 up to 70 psi (5 bar) water pressure. Molded of type 6/6 nylon. ASTM D-4066-PA 111; flammability classification 94V-2. 90 Available in sizes 3/8" through 1" conduit and tubing. Smooth internal surfaces for easier wire installation around corner angles. All nylon construction resists salt water, weak acids, gasoline, alcohol, oil, grease and common solvents. No disassembly required. No threading of the conduit or tubing required to install. Complete conduit/connector system is reusable. Use of a sealing washer may be required for wet locations. Suitable for indoor/outdoor use. Lower installed cost. LR201397 Black connectors provided with nylon locknut, packed separately. Gray connectors provided with assembled O-ring and metal locknuts. Protection class IP 68 per DIN 40050 up to 70 psi (5 bar) water pressure. Molded of type 6/6 nylon. ASTM D-4066-PA 111; flammability classification 94V-2. 1" 3/8" to 3/4" Body & Sealing Unit Locking Nut A B C D G H Part Part Clearance Max O.A. Max O.A. Thread Wrenching Std. No. No. Hole Height Length Length Thickness Flats Carton Size Black Gray Description in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) Qty. 3 /8" LT938 LT938G 90 degree L/T Fitting.875 (22.2) 1.98 (50.3) 2.91 (73.9).52 (13.2).27 (6.8) 1.06 (26.9) 25 1 /2" LT950 LT950G 90 degree L/T Fitting.875 (22.2) 1.98 (50.3) 2.91 (73.9).52 (13.2).27 (6.8) 1.06 (26.9) 25 3 /4" LT975 LT975G 90 degree L/T Fitting 1.109 (28.2) 2.29 (58.2) 3.17 (80.5).52 (13.2).27 (6.8) 1.31 (33.3) 20 1" LT9100 LT9100G 90 degree L/T Fitting 1.375 (34.9) 2.84 (72.1) 3.18 (80.8).78 (19.8).27 (6.8) 1.61 (40.9) 10 www.carlon.com 9

Technical Data Carflex Fittings Installation Instructions LT43C-CAR, LT43F thru J, LT20C-CAR, LT20F thru J. 1. Cut the end of the Carflex conduit or Carflex X-Flex tubing square. 2. Install compression nut and sealing gland ring over the end of the conduit or tubing. 3. Insert the ferrule end of the fitting into the conduit using a clockwise twisting action. 4. Screw fitting body into compression nut. 5. When installation is completed, use a wrench, tighten compression nut one-quarter (1/4) turn past hand-tight. Do not over tighten fitting. *To prevent damage to conductors, conduit and fittings, do not twist Carflex during installation. Carflex Liquidtight Conduit Technical Information 1. There shall be no more than the equivalent of four (4) quarter (90 ) bends (360 total) between pull points, conduit bodies, and boxes. 2. The radius of the curve of the center of the conduit or tubing shall not be less than that shown in the table below: SIZE OF CONDUIT RADIUS TO CENTER OF CONDUIT OR TUBING OR TUBING Inches Metric Desgr. Inches (mm) 3/8 (14) 4 (101.6) 1/2 (16) 4 (101.6) 3/4 (21) 4 1 /2 (114.3) 1 (27) 5 3 /4 (146.0) 1 1 /4 (35) 7 1 /4 (184.1) 1 1 /2 (41) 8 1 /4 (209.5) 2 (53) 9 1 /2 (241.3) UL Listed for use as indicated in Article 356 of the National Electrical Code Cellular Metal Floor Raceways, Connections to Cabinets & Wall Outlets Class I, Div. 2, Hazardous Location Class II, Div. 1, Hazardous Location Class III, Div. 1, Hazardous Location Computer Room Raised Floor Concealed Locations Intrinsically Safe Systems Lighting Fixtures, Connection to Electric Discharge Fixture Nonmetallic Boxes RV Engine Generator Swimming Pool Pump Motor LT43D-New, LT43E-New, LT20D-New, LT20E-New. 1. Cut the end of the Carflex conduit or Carflex X-Flex tubing square. 2. Install compression nut over the end of the conduit or tubing. 3. Insert the ferrule end of the fitting into the conduit using a clockwise twisting action. (Be sure conduit is fully inserted to the bottom of the fitting shoulder). 4. Screw compression nut onto fitting body. 5. Use a wrench, and tighten compression nut one (1) full turn past hand-tight. Do not over tighten fitting. *To prevent damage to conductors, conduit and fittings, do not twist Carflex during installation. Tap Conductors (Fixture Whips) Underfloor Raceway, Connection to Cabinets & Wall Outlets Wireway, Extensions from Wireways, Wiring Methods Agricultural Buildings, Flexible Connections Electric Signs, 1000 Volts, Nominal, or Less Electric Signs, Over 1000 Volts (per Section 600.32(A)(1) Floating Buildings Marinas and Boatyards Service Entrance Conductors Wiring on Buildings, Outside Branch Circuits & Feeders 10 www.carlon.com

Carflex Pre-Wired Liquidtight Whips Carflex Liquidtight Whip assemblies save the customer time and hassle of having to hunt for the needed components. Our moisture tight, nonmetallic, flexible conduit system is ideal for installing swimming pool motors, hot tubs, spas, air conditioners, pumps, outdoor lighting and more. Unlike plastic coated metal conduit, the Carlon Carflex system has no metal core to fatigue, rust, or corrode. The Carflex system has no sharp edges or burrs to cut into the wire insulation. Metal conduit is subject to fatigue and penetration of moisture. The Carflex Liquidtight Whip assembly is complete with Carflex moisture tight conduit, wire, one straight fitting, and one 90 fitting. All this makes for quick and trouble free installation. E155504 Designed for easy installation Will not rust or corrode Can be used for many commercial and residential applications. Many applications such as; swimming pool filters, hot tub spas, air conditioners, pumps, etc. Available in 1/2" and 3/4" diameters Available in 4' and 6' lengths Each kit contains (1) straight and (1) 90 fitting Complete with (3) 8, 10 or 12 gauge wires Custom Orders Also available in special configurations including different fitting combinations, wire types and sizes, and metal fitting variations. Consult factory for details. Part Wire Size Standard Carton Standard Carton Number Description (Gauge) Quantity Weight (lbs.) WCD4 1/2" Carflex Whip - 4 foot 10 6 (poly bag) 10.6 WCD6 1/2" Carflex Whip - 6 foot 10 6 (poly bag) 15.8 WCE4 3/4" Carflex Whip - 4 foot 8 6 (poly bag) 12.4 WCE6 3/4" Carflex Whip - 6 foot 8 6 (poly bag) 15.8 Part Wire Size Standard Carton Standard Carton Number Description (Gauge) Quantity Weight (lbs.) WCD3124 1/2" Carflex Whip - 4 foot 12 20 (bulk pack) 32.4 WCD3126 1/2" Carflex Whip - 6 foot 12 20 (bulk pack) 47.9 WCD3104 1/2" Carflex Whip - 4 foot 10 20 (bulk pack) 35.2 WCD3106 1/2" Carflex Whip - 6 foot 10 20 (bulk pack) 52.8 WCE3084 3/4" Carflex Whip - 4 foot 8 15 (bulk pack) 30.9 WCE3086 3/4" Carflex Whip - 6 foot 8 15 (bulk pack) 39.6 www.carlon.com 11

Carlon Cord Grips Straight PG Hubs Straight PG Hubs New threads on body prevent skipping, speed installation. PG hub threads are steel conduit per DIN 40430. Six sizes for cable, tubing, etc.: PG07, PG09, PG11, PG13.5, PG16, and PG21. All nylon construction with TPE gland resists salt water, weak acids, gasoline, alcohol, oil, grease and common solvents. Suitable for NEMA type 4 and 6 enclosures. Locknuts are included. Working temperatures: -22 F (-30ºC) to 212 F (100 C). For short periods to 302 F (150 C). Protection Class IP68 per DIN 40050 up to 70 psi (5 Bar) water pressure. B D C E A Suggested Clearance Hole For Nonthreaded Mounting E51579 Patented 4,900,068 LR93876 A B C D E Straight Diameter of Wrenching Part Std. Std. Cable or Wire Clearance Max O.A. Thread Nut Wrenching Size No. Ctn. Ctn. Accommodated Hole Length Length Thickness Flats (PG) Black Qty. Wt. in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) PG07 LH07 100 1.3.114-.250 (2.9-6.4).492 (12.5) 1.17 (29.7).33 (8.4).22 (5.6).59 (15.0) PG09 LH09 100 2.0.181-.312 (4.6-7.9).599 (15.2) 1.30 (33.0).34 (8.6).20 (5.1).75 (19.1) PG11 LH11 100 2.6.230-.395 (5.8-10.0).733 (18.6) 1.46 (37.1).39 (9.9).20 (5.1).86 (21.8) PG13.5 LH13 100 3.1.170-.470 (4.3-11.9).804 (20.4) 1.53 (38.9).41 (10.4).20 (5.1).95 (24.1) PG16 LH16 50 2.1.230-.546 (5.8-13.9).886 (22.5) 1.66 (42.2).45 (11.4).23 (5.8) 1.05 (26.7) PG21 LH21 50 3.2.450-.709 (11.4-18.0) 1.115 (28.3) 1.87 (47.5).52 (13.2).23 (5.8) 1.30 (33.0) Carlon recommends using the smallest maximum diameter fitting that will suit your application. 12 www.carlon.com

Carlon Cord Grips Straight NPT Hubs Straight NPT Hubs New threads on body prevent skipping, speed installation. Four sizes for cable, tubing, etc. with diameters of 3/8", 1/2", 3/4" and 1". All nylon construction with TPE gland resists salt water, weak acids, gasoline, alcohol, oil, grease and common solvents. Suitable for NEMA type 4 and 6 enclosures. Locknuts are included. Working temperatures: -22 F (-30 C) to 212 F (100 C). For short periods to 302 F (150ºC). Protection Class IP68 per DIN 40050 up to 70 psi (5 Bar) water pressure. B D C E A Suggested Clearance Hole For Nonthreaded Mounting E51579 Patented 4,900,068 LR93876 A B C D E Straight Straight Diameter of Wrenching Part Part Std. Std. Cable or Wire Clearance Max O.A. Thread Nut Wrenching Size No. No. Ctn. Ctn. Accommodated Hole Length Length Thickness Flats (NPT) Black Gray Qty. Wt. in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) 3/8" LH38 LH38G 100 1.9.181-.312 (4.6-7.9).670 (17.0) 1.49 (37.8).53 (13.5).20 (5.1).75 (19.1) 1/2" LH50 LH50G 100 2.9.170-.470 (4.3-11.9).875 (22.2) 1.72 (43.7).62 (15.7).20 (5.1).95 (24.1) 3/4" LH75 LH75G 50 2.7.450-.709 (11.4-18.0) 1.068 (27.1) 1.97 (50.0).63 (16.0).23 (5.8) 1.30 (33.0) 1" LH100 LH100G 25 2.6.590-1.000 (15.0-25.4) 1.375 (35.0) 2.42 (61.5).78 (19.8).28 (7.1) 1.66 (42.2) Carlon recommends using the smallest maximum diameter fitting that will suit your application. www.carlon.com 13