Interface Module Adapter SIMATIC S7-300, 400 and 1500



Similar documents
Interface Module Adapter

Temperature & Humidity SMS Alert Controller

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Safety Relays ESM/ESM-F

How To Get the Most Out of Your ERP System:

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

GAE953 Electrical Alarm Unit 19" with Indicator

Preset Counter signo 721

DMX2PWM 9 Channel Dimmer Setup Manual

SYSTEM 45. C R H Electronics Design

SYSTEM 4C. C R H Electronics Design

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

INSTALLATION & SERVICE MANUAL. Display Panel

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Inductive Proximity Sensors

RS - SPM. Serial parallel translator module

Modular I/O System Analog and Digital Interface Modules

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

PHOENIX CONTACT Features

E-STOP relays, safety gate monitors

FUEL-16, Troubleshooting Fuel Supply Problems

DCS Input/Output Relay Card Series

Specifications for EM VDC 4 In/4 Out and EM VDC 4 In/4 Relay Out

Disaster Recovery for MESSAGEmanager

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

SIMATIC. ET 200S distributed I/O Digital electronic module 8DO DC24V/0.5 A (6ES7132-4BF00-0AA0) Preface. Properties 1. Diagnostics 2.

Quick Connect. quick - simple - efficient.

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

Understanding Credit Cards

Thyristor-controlled power supplies and battery chargers

Safety technique. Emergency stop module BO 5988 safemaster

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

S-series Mass Connection Solutions

PNOZsigma - Base units

IO-RM3 3-Stage Relay Module

Digital input modules

Copyrights 2010 Victron Energy B.V. All Rights Reserved

Understanding Credit Cards

Mini Effect Gizmo. User s Manual. RJM Music Technology, Inc.

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

ENCODER TEST MODULE APPLICATION GUIDE

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Application/Connection Examples

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

NC-12 Modbus Application

Contact expansion modules

SMB Series. Effective Customer Relationship Management Software for Small to Medium-sized Businesses

P3500. Quick Start Guide

MOTION COORDINATOR MC206X Quick Connection Guide

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

ABB Drives. User s Manual HTL Encoder Interface FEN-31

RM4TG20 three-phase network control relay RM4-T - range V

Features, Benefits, and Operation

OVR Three-Phase Recloser and PCD Control Style Guide 1VAL SG October 13, 2009 Revision F

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

E-STOP relays, safety gate monitors

Solid State Relays Industrial, 1-Phase ZS w. LED Types RS 23, RS 40, RS 48

Contact expander modules

How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.

Single Port Gigabit Ethernet Media Converter Board (P/N xxx) User s Manual And Troubleshooting Guide

Automation Unit TM 1703 ACP Flexible automation and telecontrol

12V Dimmable Driver EL-TMDRVR

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Dear Customer! Thank you for choosing our product.

Blue Point Engineering

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

BG or BGE Brake Rectifier

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

3 3RG78 45 program overview

ZC-24DO CANopen I/O Module: 24 Digital Outputs


EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

Color Mark Sensor with Red or Green LED E3S-VS

PCAN-ISA. CAN Interface for ISA. User Manual

TECHNICAL DATASHEET Incremental Encoder RI 80-E

EGSTON Standard E2xFxWx 12W

Power Supplies 3. SDN-P DIN Rail Series

is then retained absolutely without interruption.

Rack mounted telephone- and leased line modem for industrial applications

Series OMEGA WATTS POWER SUPPLY AC/DC SINGLE OR MULTIPLE OUTPUT. Flexible modular design. Programmable outputs** Power factor correction***

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

instabus KNX / EIB System System E F G H

E-STOP relays, safety gate monitors

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

IO-DIM6 6-Channel, Digital to Analogue Converters

Fieldbus slave modules with I/Os, DIO

Product and functional description

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

6ES7313-5BF03-0AB0. Supply voltages Rated value 24 V DC Yes permissible range, upper limit (DC) circuit breaker type B, min. 4 A

F(t) Forssell Technologies Inc

Installation guide H A. HSI hardwired system interface

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Transcription:

s Interface Module dapter SIMTIC S7-300, 400 and 1500 Version 4.1 01/2016 Page 1

Innova on on economical base When we are talking to our customers there always seems to be a common problem: many plants are s ll opera ng with automa on systems of the previous genera on and although the performance is s ll sufficient, it will become increasingly difficult to get spare parts and to have an efficient service in the future. To be up to date, it will be necessary to replace the exis ng system with a modern unit. But quite o en this decision is delayed by the fear of disrup on of the running produc on and the inconvenience of longterm trouble shoo ng in case of incorrect wiring. Retrofit at ease xample: S7-400 The Interface Module dapter for SIMTIC S7-300 or SIMTIC S7-400 links the old with the new, field proven produc on systems with the latest achievements in automa on systems. You simply take off the front plug of the I/O units, replace the automa on system by a S7, plug in the IM and fix the front plug back on to the adapter. ll is done easily by plug-ins. nd a er actualisa on of the STP 7 so ware you can con nue with you produc on. Version 4.1 01/2016 Page 2

dvantages are obvious There are low engineering costs in the hardware, only a replacement of the controller is necessary. ll wiring remains at ist place Schema c diagrams don t have to be revised; signal lists are automa cally updated by the so ware. The shutdown me of the produc on is reduced. This procedure not only saves a lot of me and money, but also reduces errors. Contact Thomas Hener telephone: 49 (711) 137-2569 fax: 49 (711) 137-2056 email: thomas.hener@siemens.com Gerhard Rossel telephone: 49 (172) 6877694 49 (711) 32778361 fax: 49 (711) 32778366 email: gerhard.rossel@siemens.com SIMNS G RC-D DF S-VS 7 1 Weissacher Str. 11 D 70499 Stu gart Zer fikat: U8 14 12 43507 002 Version 4.1 01/2016 Page 3

Types of controllers The use of IM is provided for the following controllers: S5 115 U S5 130 W/K S5 135 U S5 150 U S5 155 S/U S5 150 K utoma on device is the S7-300, S7-400 or S7-1500. Digital Input: The digital inputs are classified by the following technical features: Number of channels: 8/16/32 Poten al separa on: internal / external Grouping of channels: 1/4/8/16/32 Signal voltage: TTL/24=/60=/115~/230~ Switching frequency Type of connector: Screw/Crimp 42/20-poles Space requirement: single / double space Interrupt signal nable signal Unit encoding ddress encoding Digital Output: The digital outputs are classified by the following technical features: Number of channels: 8/16/32 Poten al separa on: internal / external Grouping of channels: 1/4/8/16/32 Signal voltage: TTL/24=/60=/115~/230~ Switching frequency Type of connector: Screw/Crimp 42/20-poles Space requirement: single / double space Short circuit protec on: none / fuse / electronic Switching Capacity: 0,1/0,5/2 Voltage limita on Unit encoding ddress encoding ll these specifica ons must be considered before replacement. Version 4.1 01/2016 Page 4

Structure with S7-300 Moun ng angle For S7-300 rail Front connector S7-300 Connec ng cable ma ng connector for S5 front connector Rail for S7-300 6S7390-1 -00 Case with printed circuit board Technical data: Case with printed circuit board : H x B x T = 330 x 27 x 70 mm Connec ng cable: l= 500mm Moun ng angle Set: H = 150 to 280 mm, B = 80 mm S7-rail and S7-300 are not included. Version 4.1 01/2016 Page 5

Structure with S7-400 ma ng connector for S5 front connector S7-front connector with prited circuit board Dimensions adapter 237mm- S7 400 225 mm - S5 135U.. 234 mm- S5 115 U 259 mm S5 150K.. H x B x T = 290 x 25 x 70 mm 70 dapter Frontstecker Moun ng depth: S7 400: 237mm70mm dapter S5 150U S5 150K S5 115U 225mm 259mm 234mm 297 Version 4.1 Page 6 01/2016

Structure with S7-1500 Case with printed circuit board Connec ng cable Rail 6S7 590-1 Front connector S7-1500 ma ng connector for S5 front connector Rail 6S7 390-1 Technical data: Case with printed circuit board : H x B x T = 330 x 27 x 70 mm Connec ng cable: l= 500mm Moun ng angle Set: H = 150 to 280 mm, B = 80 mm S7-rails and S7-1500 are not included. Version 4.1 01/2016 Page 7

Powersupply Separa on of poten als 230V~ 230V~ There are floa ng or non-floa ng IOs. Netzgerät 24V DC Netzgerät 24V DC In both cases the power for the module has to be supplied by the user. 24VDC L L- Potentialfrei 24VDC L L- nother criterion is the short circuit protec on of the signals. The outputs have to be tested for the ra ng of the pins and the printed conductor. Therefore the power supply of signals is rooted in groups of 1/2/4/8/16. Potentialgebunden Version 4.1 01/2016 Page 8

Version 4.1 01/2016 Page 9 L1 L2 L3 PN P _ ~ ~ 1L 2L 1M DC I0.0 I0.1 I0.2 I0.3 C I0.4 I0.5 I0.6 I0.7 2M 2M 1M I0.0 I0.1 I0.2 I0.3 I0.4 I0.5 I0.6 I0.7 2M 1M dapter L I0.0 I0.1 I0.2 I0.3 I0.4 I0.5 I0.6 I0.7 1N 2N L1 1L 2L 1N 2N I0.0 I0.1 I0.2 I0.3 I0.4 I0.5 I0.6 I0.7 dapter I0.0 1N 2N L S5 S7 S5 S7 nlage nlage Powersupply of inputs Powersupply of inputs L1 L2 L3 PN P _ ~ ~ 1L 2L DC I0.0 I0.1 I0.2 I0.3 C I0.4 I0.5 I0.6 I0.7 I0.0 I0.1 I0.2 I0.3 I0.4 I0.5 I0.6 I0.7 dapter 1L 2L nlage S5 S7 1L M 1L 2L 2L M M M I0.0 I0.1 I0.2 I0.3 I0.4 I0.5 I0.6 I0.7 I0.0 I0.1 I0.2 I0.3 I0.4 I0.5 I0.6 I0.7 dapter nlage S5 S7 M M 1N 2N 1L 2L 1L 2L

Version 4.1 01/2016 Page 10 Roo ng - 4 er-wurzelung - - - - - 2 er-wurzelung 8er-Wurzelung - - 1 er-wurzelung - 1 16 er-wurzelung 1-16 16-1 1-32 er-wurzelung 32 32

Conditions of Sale The Interface Module dapters 6Z2 041-8UG.. are intended to be used between the front-plugs on the I- O-modules of an obsolete controller and a modern replacement controller SIMTIC S7. Hereby all installa- on remains at its place; only the controller and the respec ve so ware have to be subs tuted. For the subs tu on of the up-to-now-used units the best matching units of S7- components were selected. However there remains a certain devia on in the specific performance. It is up to the user to check the limita ons of his own installa on, in par cular the: Power supply Signal voltage Line-frequency Limits of I-O-defini ons Roo ng Number of channels Loading capacity Ra ng of connectors Signal switching frequency If the S7-units do require an external applica on of /- poten als and the old installa on did not supply them, these poten als have to be brought to the terminal block on the adapter or to the S5 front connector. If the power-roo ng of the old installa on is not corresponding to the new requirements, the user has to install the addi onal jumpers. If the old installa on was fed from different power sources, an equipoten al bonding contactor has to be applied. The enable signal of the S5 units is not present in the S7-system in an iden cal way and may be considered on handling. The parametering and selec on of modes in the I/O units has to be done according to the requirements of the S7. Version 4.1 01/2016 Page 11

S5_115U --> S7_300 S5 module I/O Voltage Current dapter S7 module 6S5 420-7L11 32 DI 24 VDC 6Z2041-8UG02-0D0 6S7 321-1BL00-00 6S5 430-7L12 32 DI 24 VDC 6Z2041-8UG02-0D0 6S7 321-1BL00-00 6S5 431-7L11 16 DI 24/48 VUC 6Z2041-8UG02-0D1 6S7 321-1CH00-00 6S5 432-7L11 16 DI 48-60 VUC 6Z2041-8UG02-0D1 6S7 321-1CH00-00 6S5 434-7L12 8 DI 24 VDC 6Z2041-8UG02-0D2 6S7 321-1CH00-00 6S5 435-7L11 16 DI 115 VUC 6Z2041-8UG02-0D3 6S7 321-1FH00-00 6S5 435-7LB11 16 DI 115 VUC 6Z2041-8UG02-0D4 6S7 321-1FF01-00 6S5 435-7LC11 8 DI 115 VUC 6Z2041-8UG02-0D5 6S7 321-1FF10-00 6S5 436-7L11 16 DI 230 VUC 6Z2041-8UG02-0D3 6S7 321-1FH00-00 6S5 436-7LB11 16 DI 230 VUC 6Z2041-8UG02-0D4 6S7 321-1FF01-00 6S5 436-7LC11 8 DI 230 VUC 6Z2041-8UG02-0D5 6S7 321-1FF10-00 6S5 441-7L13 32 DO 24 VDC 0,5 6Z2041-8UG02-0D0 6S7 322-1BL00-00 6S5 451-7L12 32 DO 24 VDC 0,5 6Z2041-8UG02-0D0 6S7 322-1BL00-00 6S5 451-7L21 32 DO 24 VDC 0,5 6Z2041-8UG02-0D0 6S7 322-1BL00-00 6S5 453-7L11 16 DO 24-60 VDC 0,5 6Z2041-8UG02-0D1 6S7 322-5GH00-0B0 6S5 454-7L12 16 DO 24 VDC 2 6Z2041-8UG02-0D2 6S7 322-1BF01-00 6S5 456-7L11 16 DO 115/230 VC 1 6Z2041-8UG02-0D5 6S7 322-1FF01-00 6S5 456-7LB11 8 DO 115/230 VC 2 6Z2041-8UG02-0D6 6S7 322-5FF00-0B0 6S5 458-7L12 16 DO Rel 0,5 6Z2041-8UG02-0D7 6S7 322-5HF00-0B0 6S5 458-7LB11 8 DO Rel 5 6Z2041-8UG02-0D8 6S7 322-5HF00-0B0 6S5 458-7LC11 16 DO Rel 5 6Z2041-8UG02-0D9 6S7 322-5HF00-0B0 6S5 482-7L11 16D/16D 24 VDC 0,5 6Z2041-8UG02-00 6S7 323-1BL00-00 6S5 460-7L13 8 current and voltage metering 6Z2041-8UG02-01 6S7 331-7KF02-0B0 6S5 460-7L13 8 only current metering 6Z2041-8UG02-11 6S7 331-7NF00-0B0 6S5 460-7L13 8 only voltage metering 6Z2041-8UG02-21 6S7 331-7NF00-0B0 6S5 465-7L13 16 current and voltage metering 6Z2041-8UG02-02 6S7 331-7KF02-0B0 6S5 465-7L13 8 only PT100 6Z2041-8UG02-12 6S7 331-7PF01-0B0 6S5 465-7L13 8 only PT100 6Z2041-8UG02-22 6S7 331-1KF01-0B0 6S5 470-7L13 8 current and voltage output 6Z2041-8UG02-00 6S7 332-5HD01-0B0 6S5 470-7L13 8 current and voltage output 6Z2041-8UG02-10 6S7 332-5HF00-0B0 6S5 470-7LB13 8 only voltage output 6Z2041-8UG02-00 6S7 332-5HD01-0B0 6S5 470-7LB13 8 only voltage output 6Z2041-8UG02-10 6S7 332-5HF00-0B0 6S5 470-7LC13 8 current and voltage output 6Z2041-8UG02-00 6S7 332-5HD01-0B0 6S5 470-7LC13 8 current and voltage output 6Z2041-8UG02-10 6S7 332-5HF00-0B0 6Z2041-8UG02-0DU0 6Z2041-8UG02-0DU1 open ended terminal adapter

S5_115U --> S7_300 ccessories 6Z2041-8UG00-0BG0 Mounting angle (2 pieces) max. allowable 48V switched on 2 S7-modules only 16DI/DO only C and switched on 2 S7- modules M must be wired N must be wired and switched on 2 S7-modules only C in-phase

S5_115U --> S7_400 S5 module I/O Voltage Current dapter S7 module 6S5 420-7L11 32 DI 24 VDC 6Z2041-8UG05-0U36 6S7 421-1BL01-00 6S5 430-7L12 32 DI 24 VDC 6Z2041-8UG05-0U36 6S7 421-1BL01-00 6S5 431-7L11 16 DI 24/48 VUC 6Z2041-8UG65-0U22 6S7 421-7DH00-0B0 6S5 432-7L11 16 DI 48-60 VUC 6Z2041-8UG65-0U22 6S7 421-7DH00-0B0 6S5 434-7L12 8 DI 24 VDC 6Z2041-8UG05-0U10 6S7 421-7DH00-0B0 6S5 435-7L11 16 DI 115 VUC 6Z2041-8UG55-0U22 6S7 421-1FH20-00 6S5 435-7LB11 16 DI 115 VUC 6Z2041-8UG55-0U21 6S7 421-1FH20-00 6S5 435-7LC11 8 DI 115 VUC 6Z2041-8UG55-0U10 6S7 421-1FH20-00 6S5 436-7L11 16 DI 230 VUC 6Z2041-8UG55-0U22 6S7 421-1FH20-00 6S5 436-7LB11 16 DI 230 VUC 6Z2041-8UG55-0U21 6S7 421-1FH20-00 6S5 436-7LC11 8 DI 230 VUC 6Z2041-8UG55-0U10 6S7 421-1FH20-00 6S5 441-7L13 32 DO 24 VDC 0,5 6Z2041-8UG05-0U33 6S7 422-1BL00-00 6S5 451-7L12 32 DO 24 VDC 0,5 6Z2041-8UG05-0U33 6S7 422-1BL00-00 6S5 451-7L21 32 DO 24 VDC 0,5 6Z2041-8UG05-0U33 6S7 422-1BL00-00 6S5 454-7L12 16 DO 24 VDC 2 6Z2041-8UG05-0U22 6S7 422-1BH11-00 6S5 455-7L11 16 DO 115 VC 2 6Z2041-8UG45-0U21 6S7 422-1HH00-00 6S5 456-7L11 16 DO 230 VC 1 6Z2041-8UG55-0U22 6S7 422-1FH00-00 6S5 458-7LC11 16 DO Rel 5 6Z2041-8UG65-0U22 6S7 422-1HH00-0B0 6S5 460-7L13 8 only current metering 6Z2041-8UG75-0U11 6S7 431-1KF00-0B0 6S5 460-7L13 8 only voltage metering 6Z2041-8UG75-0U12 6S7 431-1KF00-0B0 6S5 465-7L13 8 only PT100 6Z2041-8UG75-0U20 6S7 431-7KF10-0B0 6S5 465-7L13 8 current and voltage metering 6Z2041-8UG75-0U21 6S7 431-7QH00-0B0 6S5 465-7L13 8 current and voltage metering 6Z2041-8UG75-0U21 6S7 431-0HH00-0B0 6S5 470-7L13 8 current and voltage outout 6Z2041-8UG75-0U11 6S7 432-1HF00-0B0 6S5 470-7LB13 8 only voltage output 6Z2041-8UG75-0U11 6S7 432-1HF00-0B0 6S5 470-7LC13 8 current and voltage outout 6Z2041-8UG75-0U11 6S7 432-1HF00-0B0 ttention: Front connector with double width needs more place!

S5_135_155U --> S7_400 S5 module I/O Voltage Current dapter S7 module 6S5 420-4U14 32 DI 24 VDC 6Z2041-8UG07-0U36 6S7 421-1BL01-00 6S5 430-4U14 32 DI 24 VDC 6Z2041-8UG07-0U36 6S7 421-1BL01-00 6S5 431-4U12 16 DI 24/60 VDC 6Z2041-8UG07-0U20 6S7 421-7DH00-0B0 6S5 432-4U12 32DI 24 VDC 6Z2041-8UG07-0U33 6S7 421-1BL01-00 6S5 435-4U12 16 DI 24/60 VDC 6Z2041-8UG37-1U23 6S7 421-7DH00-0B0 6S5 436-4U12 16 DI 115/230 VC 6Z2041-8UG57-1U23 6S7 421-1FH20-00 6S5 436-4UB12 8 DI 115/230 VC 6Z2041-8UG57-1U20 6S7 421-1FH20-00 6S5 441-4U14 32 DO 24 VDC 0,5 6Z2041-8UG07-0U36 6S7 422-1BL00-00 6S5 441-4U14 32 DO 24 VDC 0,5 6Z2041-8UG07-0U37 6S7 422-7BL00-0B0 6S5 451-4U14 32 DO 24 VDC 0,5 6Z2041-8UG07-0U37 6S7 422-7BL00-0B0 6S5 451-4U14 32 DO 24 VDC 0,5 6Z2041-8UG07-0U36 6S7 422-1BL00-00 6S5 454-4U14 16 DO 24 VDC 2 6Z2041-8UG07-1U23 6S7 422-1BH11-00 6S5 456-4U14 16 DO 115/230 VC 2 6Z2041-8UG57-1U23 6S7 422-1FH00-00 6S5 458-4UC11 16 DO Relais 5 6Z2041-8UG67-0U23 6S7 422-1HH00-00 6S5 460-4U13 8 I only current metering 6Z2041-8UG77-0U11 6S7 431-1KF00-0B0 6S5 460-4U13 8 I only voltage metering 6Z2041-8UG77-0U12 6S7 431-1KF00-0B0 6S5 465-4U13 8 I only PT100 6Z2041-8UG77-0U20 6S7 431-7KF10-0B0 6S5 465-4U13 16 I current and voltage metering 6Z2041-8UG77-0U21 6S7 431-0HH00-0B0 6S5 465-4U13 16 I current and voltage metering 6Z2041-8UG77-0U21 6S7 431-7QH00-0B0 6S5 470-4U13 8 O only current output 6Z2041-8UG77-0U11 6S7 432-1HF00-0B0 6S5 470-4UC13 8 O only current output 6Z2041-8UG77-0U11 6S7 432-1HF00-0B0 6S5 470-4U13 8 O only voltage output 6Z2041-8UG77-0U12 6S7 432-1HF00-0B0 6S5 470-4UB13 8 O only voltage output 6Z2041-8UG77-0U12 6S7 432-1HF00-0B0 6S5 470-4UC13 8 O only voltage output 6Z2041-8UG77-0U12 6S7 432-1HF00-0B0 ttention: Front connector with double width needs more place!

S5_135_155U --> S7_300 S5 module I/O Voltage Current dapter S7 module 6S5 420-4U14 32 DI 24 VDC 6Z2041-8UG01-0D0 6S7 321-1BL00-00 6S5 430-4U14 32 DI 24 VDC 6Z2041-8UG01-0D0 6S7 321-1BL00-00 6S5 431-4U12 16 DI 24/60 VDC 6Z2041-8UG01-0D1 6S7 321-1CH00-00 6S5 432-4U12 32DI 24 VDC 6Z2041-8UG01-0D2 6S7 321-1BL00-00 6S5 435-4U12 16 DI 24/60 VDC 6Z2041-8UG01-0D3 6S7 321-1CH00-00 6S5 436-4U12 16 DI 115/230 VC 6Z2041-8UG01-0D4 6S7 321-1FH00-00 6S5 436-4UB12 8 DI 115/230 VC 6Z2041-8UG01-0D5 6S7 321-1FF10-00 6S5 441-4U14 32 DO 24 VDC 0,5 6Z2041-8UG01-0D0 6S7 322-1BL00-00 6S5 451-4U14 32 DO 24 VDC 0,5 6Z2041-8UG01-0D0 6S7 322-1BL00-00 6S5 454-4U14 16 DO 24 VDC 2 6Z2041-8UG01-0D2 6S7 322-1BF01-00 6S5 456-4U12 16 DO 115/230 VC 2 6Z2041-8UG01-0D3 6S7 322-1FF01-00 6S5 456-4UB12 8 DO 115/230 VC 2 6Z2041-8UG01-0D4 6S7 322-5FF00-0B0 6S5 458-4UC11 16 DO Relais 5 6Z2041-8UG01-0D5 6S7 322-1HH01-0B0 6S5 482-4U11 16DI/16DO 24 VDC 0,5 6Z2041-8UG01-00 6S7 323-1BL00-00 6S5 482-4U20 16DI/16DO 24 VDC 0,5 6Z2041-8UG01-00 6S7 323-1BL00-00 6S5 460-4U13 8 I current and voltage metering 6Z2041-8UG01-00 6S7 331-7KF02-0B0 6S5 460-4U13 8 I only PT100 6Z2041-8UG01-10 6S7 331-7PF01-0B0 6S5 460-4U13 8 I only current metering 6Z2041-8UG01-20 6S7 331-7NF00-0B0 6S5 460-4U13 8 I only voltage metering 6Z2041-8UG01-30 6S7 331-7NF00-0B0 6S5 465-4U13 16 I current and voltage metering 6Z2041-8UG01-02 6S7 331-7KF02-0B0 6S5 465-4U13 8 I only PT100 6Z2041-8UG01-12 6S7 331-7PF01-0B0 6S5 465-4U13 8 I only PT100 6Z2041-8UG01-22 6S7 331-7KF01-0B0 6S5 470-4U13 8 O current and voltage outout 6Z2041-8UG01-00 6S7 332-5HD01-0B0 6S5 470-4U13 8 O current and voltage outout 6Z2041-8UG01-10 6S7 332-5HF00-0B0 6S5 470-4UB13 8 O only voltage output 6Z2041-8UG01-00 6S7 332-5HD01-0B0 6S5 470-4UC13 8 O only voltage output 6Z2041-8UG01-10 6S7 332-5HF00-0B0 6S5 470-4UC13 8 O current and voltage outout 6Z2041-8UG01-00 6S7 332-5HD01-0B0 6S5 470-4U13 8 O current and voltage outout 6Z2041-8UG01-10 6S7 332-5HF00-0B0 6Z2041-8UG01-0DU1 6Z2041-8UG01-0DU0 Klemmenadapter open ended ccessories 6Z2041-8UG00-0BG0 Mounting angle (2 pieces) max. allowable 48V switched on 2 S7-modules only 16DI/DO only C and switched on 2 S7- modules M must be wired N must be wired and switched on 2 S7-modules

S5_130_150K --> S7_300 S5 module I/O Voltage Current dapter S7 module 6S5 420-3B11 32 DI 24 VDC 6Z2041-8UG03-0D0 6S7 321-1BL00-00 6S5 430-3B11 32 DI 24 VDC 6Z2041-8UG03-0D0 6S7 321-1BL00-00 6S5 431-3B11 16 DI 24-60 VDC 6Z2041-8UG03-0D1 6S7 321-1CH00-00 6S5 442-311 32 DO 24 VDC 10 m 6Z2041-8UG03-0D0 6S7 322-1BL00-00 6S5 444-311 16 DO 24 VDC 2 6Z2041-8UG03-0D1 6S7 322-1BF01-00 6S5 445-312 32 DO 24 VDC 0,5 6Z2041-8UG03-0D2 6S7 322-1BL00-00 6S5 450-311 32 DO 24-60 VDC 0,12 6Z2041-8UG03-0D2 6S7 322-1BL00-00 6S5 451-311 16 DO 24 VDC 0,5 6Z2041-8UG03-0D3 6S7 322-1BH01-00 ccessories 6Z2041-8UG00-0BG0 Mounting angle (2 pieces) max. allowable 48V N must be wired and switched on 2 S7-modules M must be wired

S5_130_150K --> S7_400 S5 module I/O Voltage Current dapter S7 module 6S5 420-3B11 32 DI 24 VDC 6Z2041-8UG08-0D0 6S7 421-1BL01-00 6S5 430-3B11 32 DI 24 VDC 6Z2041-8UG08-0D0 6S7 421-1BL01-00 6S5 431-3B11 16 DI 24-60 VDC 6Z2041-8UG08-0D1 6S7 421-7DH00-00 6S5 442-311 32 DO 24 VDC 10 m 6Z2041-8UG08-0D1 6S7 422-1BL00-00 6S5 444-311 16 DO 24 VDC 2 6Z2041-8UG08-0D2 6S7 422-1BH11-00 6S5 445-312 32 DO 24 VDC 0,5 6Z2041-8UG08-0D0 6S7 422-1BL00-00 6S5 450-311 32 DO 24-60 VDC 0,12 6Z2041-8UG08-0D0 6S7 422-1BL00-00 6S5 451-311 16 DO 24 VDC 0,5 6Z2041-8UG08-0D3 6S7 422-1BH11-00 M must be wired

S5_135_155U --> S7_1500 S5 module I/O Voltage current- dapter S7 module 6S5 420-4U14 32 DI 24 VDC 6Z2041-8UG11-0D0 6S7 521-1BL00-0B0 6S5 430-4U14 32 DI 24 VDC 6Z2041-8UG11-0D0 6S7 521-1BL00-0B0 6S5 431-4U12 16 DI 24/60 VDC 6Z2041-8UG11-0D1 6S7 521-1BH00-0B0 6S5 432-4U12 32DI 24 VDC 6Z2041-8UG11-0D2 6S7 521-1BL00-0B0 6S5 436-4U12 16 DI 115/230 VC 6Z2041-8UG11-0D4 6S7 521-1FH00-00 6S5 436-4UB12 8 DI 115/230 VC 6Z2041-8UG11-0D5 6S7 521-1FH00-00 6S5 441-4U14 32 DO 24 VDC 0,5 6Z2041-8UG11-0D0 6S7 522-1BL00-0B0 6S5 451-4U14 32 DO 24 VDC 0,5 6Z2041-8UG11-0D0 6S7 522-1BL00-0B0 6S5 454-4U14 16 DO 24 VDC 2 6Z2041-8UG11-0D1 6S7 522-1BH00-0B0 6S5 454-4U14 16 DO 24 VDC 2 6Z2041-8UG11-0D2 6S7 522-1BF00-0B0 6S5 456-4U12 16 DO 115/230 VC 2 6Z2041-8UG11-0D3 6S7 522-5FF00-0B0 6S5 456-4U12 16 DO 115/230 VC 2 6Z2041-8UG11-0D4 6S7 522-5HF00-0B0 6S5 456-4UB12 8 DO 115/230 VC 2 6Z2041-8UG11-1D3 6S7 522-5FF00-0B0 6S5 456-4U12 16 DO 115/230 VC 2 6Z2041-8UG11-1D4 6S7 522-5HF00-0B0 6S5 458-4UC11 16 DO Relais 5 6Z2041-8UG11-2D4 6S7 522-5HF00-0B0 6S5 458-4UC11 16 DO Relais 5 6Z2041-8UG11-0D5 6S7 522-5HH00-0B0 6S5 460-4U13 8 I voltage metering / PT100 6Z2041-8UG11-00 6S7 531-7KF00-0B0 6S5 460-4U13 8 I voltage metering / PT100 6Z2041-8UG11-00 6S7 531-7NF10-0B0 current- metering 2-wiretransducer 6S5 460-4U13 8 I 6Z2041-8UG11-20 6S7 531-7KF00-0B0 current- metering 2-wiretransducer 6S5 460-4U13 8 I 6Z2041-8UG11-20 6S7 531-7NF10-0B0 current- metering 4-wiretransducer 6S5 460-4U13 8 I 6Z2041-8UG11-30 6S7 531-7KF00-0B0 current- metering 4-wiretransducer 6S5 460-4U13 8 I 6Z2041-8UG11-30 6S7 531-7NF10-0B0 6S5 465-4U13 16 I voltage metering 6Z2041-8UG11-02 6S7 531-7KF00-0B0 6S5 465-4U13 16 I voltage metering 6Z2041-8UG11-02 6S7 531-7NF10-0B0 current- metering 2-wiretransducer 6S5 465-4U13 16 I 6Z2041-8UG11-12 6S7 531-7KF00-0B0 current- metering 2-wiretransducer 6S5 465-4U13 16 I 6Z2041-8UG11-12 6S7 531-7NF10-0B0 current- metering 4-wiretransducer 6S5 465-4U13 16 I 6Z2041-8UG11-22 6S7 531-7KF00-0B0 current- metering 4-wiretransducer 6S5 465-4U13 16 I 6Z2041-8UG11-22 6S7 531-7NF10-0B0 PT100 measuringmodule 6S5 465-4U13 16 I 6Z2041-8UG11-32 6S7 531-7KF00-0B0 6S5498-111 6S5 470-4U13 8 O current-- / voltage metering 6Z2041-8UG11-00 6S7 532-5HD00-0B0 6S5 470-4UB13 8 O current- / voltage metering 6Z2041-8UG11-00 6S7 532-5HD00-0B0 6S5 470-4UC13 8 O current- / voltage metering 6Z2041-8UG11-00 6S7 532-5HD00-0B0

S5_135_155U --> S7_1500 S5 module I/O Voltage current- dapter S7 module 6S5 470-4U13 8 O current- / voltage metering 6Z2041-8UG11-10 6S7 532-5HF00-0B0 6S5 470-4UB13 8 O current- / voltage metering 6Z2041-8UG11-10 6S7 532-5HF00-0B0 6S5 470-4UC13 8 O current- / voltage metering 6Z2041-8UG11-10 6S7 532-5HF00-0B0 6Z2041-8UG01-0DU1 6Z2041-8UG01-0DU0 6Z2041-8UG00-0BG0 terminal adapter open ended mounting angle (2 pieces) switched on 2 S7-modules, S7- module with 0.5 observe technical data of S7-module switched on 2 S7-modules

S5_115U --> S7_1500 S5 module I/O Voltage Current dapter S7 module 6S5 420-7L11 32 DI 24 VDC 6Z2041-8UG12-0D0 6S7 521-1BL00-0B0 6S5 430-7L12 32 DI 24 VDC 6Z2041-8UG12-0D0 6S7 521-1BL00-0B0 6S5 431-7L11 16 DI 24/48 VUC 6Z2041-8UG12-0D1 6S7 521-1BH00-0B0 6S5 434-7L12 8 DI 24 VDC 6Z2041-8UG12-0D2 6S7 521-1BH00-0B0 6S5 435-7L11 16 DI 115 VUC 6Z2041-8UG12-0D3 6S7 521-1FH00-00 6S5 435-7LB11 16 DI 115 VUC 6Z2041-8UG12-0D4 6S7 521-1FH00-00 6S5 436-7L11 16 DI 230 VUC 6Z2041-8UG12-0D3 6S7 521-1FH00-00 6S5 436-7LB11 16 DI 230 VUC 6Z2041-8UG12-0D4 6S7 521-1FH00-00 6S5 441-7L13 32 DO 24 VDC 0,5 6Z2041-8UG12-0D0 6S7 522-1BL00-0B0 6S5 451-7L12 32 DO 24 VDC 0,5 6Z2041-8UG12-0D0 6S7 522-1BL00-0B0 6S5 451-7L21 32 DO 24 VDC 0,5 6Z2041-8UG12-0D0 6S7 522-1BL00-0B0 6S5 453-7L11 16 DO 24-60 VDC 0,5 6Z2041-8UG12-0D1 6S7 522-1BH00-0B0 6S5 454-7L12 16 DO 24 VDC 2 6Z2041-8UG12-1D1 6S7 522-1BH00-0B0 6S5 454-7LB11 8 DO 24 VDC 2 6Z2041-8UG12-0D2 6S7 522-1BF00-0B0 6S5 456-7L11 16 DO 115/230 VC 1 6Z2041-8UG12-0D3 6S7 522-5FF00-0B0 6S5 456-7L11 16 DO 115/230 VC 1 6Z2041-8UG12-0D4 6S7 522-5HF00-0B0 6S5 456-7LB11 8 DO 115/230 VC 1,5 6Z2041-8UG12-1D3 6S7 522-5FF00-0B0 6S5 456-7LB11 8 DO 115/230 VC 1,5 6Z2041-8UG12-1D4 6S7 522-5HF00-0B0 6S5 458-7L12 16 DO Rel. UC 30V 0,5 6Z2041-8UG12-2D4 6S7 522-5HF00-0B0 6S5 458-7LB11 8 DO Rel.C250V 5 6Z2041-8UG12-3D4 6S7 522-5HF00-0B0 6S5 458-7LC11 16 DO Rel.C250V 5 6Z2041-8UG12-4D4 6S7 522-5HF00-0B0 6S5 460-7L13 8 I voltage metering / PT100 / 2- wire-transducer 6Z2041-8UG12-01 6S7 531-7KF00-0B0 6S5 460-7L13 8 I voltage metering / PT100 / 2- wire-transducer 6Z2041-8UG12-01 6S7 531-7NF10-0B0 6S5 460-7L13 8 I current metering 6Z2041-8UG12-11 6S7 531-7KF00-0B0 6S5 460-7L13 8 I current metering 6Z2041-8UG12-11 6S7 531-7NF10-0B0 6S5 460-7L13 8 I current metering / 4-wiretransducer 6Z2041-8UG12-21 6S7 531-7KF00-0B0 6S5 460-7L13 8 I current metering / 4-wiretransducer 6Z2041-8UG12-21 6S7 531-7NF10-0B0 6S5 465-7L13 16 I voltage metering 6Z2041-8UG12-02 6S7 531-7KF00-0B0 6S5 465-7L13 16 I voltage metering 6Z2041-8UG12-02 6S7 531-7NF10-0B0 6S5 465-7L13 16 I current metering / 2-wiretransducer 6Z2041-8UG12-22 6S7 531-7KF00-0B0 6S5 465-7L13 16 I current metering / 2-wiretransducer 6Z2041-8UG12-22 6S7 531-7NF10-0B0 6S5 465-7L13 16 I current metering / 4-wiretransducer 6Z2041-8UG12-32 6S7 531-7KF00-0B0 6S5 465-7L13 16 I current metering / 4-wiretransducer 6Z2041-8UG12-32 6S7 531-7NF10-0B0

S5_115U --> S7_1500 S5 module I/O Voltage Current dapter S7 module 6S5 470-7L13 8 O Current - / voltage metering 6Z2041-8UG12-00 6S7 532-5HD00-0B0 6S5 470-7LB13 8 O Current - / voltage metering 6Z2041-8UG12-00 6S7 532-5HD00-0B0 6S5 470-7LC13 8 O Current - / voltage metering 6Z2041-8UG12-00 6S7 532-5HD00-0B0 6S5 470-7L13 8 O Current - / voltage metering 6Z2041-8UG12-10 6S7 532-5HF00-0B0 6S5 470-7LB13 8 O Current - / voltage metering 6Z2041-8UG12-10 6S7 532-5HF00-0B0 6S5 470-7LC13 8 O Current - / voltage metering 6Z2041-8UG12-10 6S7 532-5HF00-0B0 6S5 470-7L13 8 I voltage metering / PT100 6Z2041-8UG12-01 6S7 531-7KF00-0B0 6S5 470-7L13 8 I voltage metering / PT100 6Z2041-8UG12-01 6S7 531-7NF10-0B0 6Z2041-8UG02-0DU1 6Z2041-8UG02-0DU0 6Z2041-8UG00-0BG0 terminal adapter open ended mounting angle (2 pieces) switched on 2 S7-modules observe technical data of S7-module

S5_115U --> S7_1500 T MP S5 module I/O Voltage Current dapter S7 module 6S7482-7L11 16DI/16DO 24 VDC 6Z2041-8UG22-00 6S7523-1BL00-00 6Z2041-8UG02-0DU1 6Z2041-8UG02-0DU0 6Z2041-8UG00-0BG0 terminal adapter open ended mounting angle (2 pieces) switched on 2 S7-modules observe technical data of S7-module