Router Connection Details



Similar documents
Timeout The Crosspoint Status Request message has a timeout, which means that you need to wait 1 second in between request messages.

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

How to setup a serial Bluetooth adapter Master Guide

E-Blocks Easy Internet Bundle

1.1 Connection Direct COM port connection. 1. Half duplex RS232 spy cable without handshaking

Using HyperTerminal with Agilent General Purpose Instruments

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

UPS Network Interface. Quick InstallationGuide

VSCOM USB PRO Series Industrial I/O Adapters

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4

MS830 / MS833 Barcode Reader v1.0 9-December-2014

Cable Pinouts. SRP I/O Module

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

isco Connecting Routers Back to Back Through the AUX P

Modbus Communications for PanelView Terminals

RS-422/485 Multiport Serial PCI Card. RS-422/485 Multiport Serial PCI Card Installation Guide

Application Note 2. Using the TCPDIAL & TCPPERM Commands to Connect Two TransPort router Serial Interfaces Over TCP/IP.

Connecting the Console Port to a PC

PCMCIA 1 Port RS EDITION OCTOBER 1999

Configuring IP to Serial with Auto Answer and Serial to IP

FINS Gateway For OMRON PLCs

Cabling Guide for Console and AUX Ports

Advanced Data Capture and Control Systems

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

TRP-C31M MODBUS TCP to RTU/ASCII Gateway

PM1122 INT DIGITAL INTERFACE REMOTE

1 Serial RS232 to Ethernet Adapter Installation Guide

Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual

How to setup a serial Bluetooth adapter

Modbus and ION Technology

How To Connect A Directsofl To A Powerpoint With An Acd With An Ctel With An Dm-Tel Modem On A Pc Or Ipad Or Ipa (Powerpoint) With A Powerline 2 (Powerline

LS-101 LAN to Serial Device server. User s Manual

LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server

Installation Guide. AXIS 2191 Audio Module Sight, Speech and Sound over IP!

How To Set Up A Smart Card Programmer With Titan (Titan) And Titan 2.3 (Tok) (Tonga) (Powerbook) (Smart Card) (Programmer) (S

WinPFT File Transfer Utility (Catalog No ND7)

NC-12 Modbus Application

When we look at the connector pinout of the RS232 port, we see two pins which are certainly used

LBNP RS-232/485/422 serial device server. User manual

CDI-S100 SERIAL INTERFACE CARD

INTRODUCTION FEATURES OF THE ICM

PLC training panel (Twido version)

How to setup the UCW232C Serial WiFi adapter

Encore Controller to Router Connections

ADSL Router Quick Installation Guide Revised, edited and illustrated by Neo

Elo Interactive Digital Signage (IDS): Remote Management

TallyMan Controllers Introduction

RS232 Board datasheet

Configuring the Siemens TC35 modems for use with the MI2292

WHQL Certification Approval...2 User Interface...3 SUNIX s COMLab..4

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

Bluetooth HC-06 with serial port module Easy guide

RJ45 Shielded (standard) port pinout. CS9000, Jetstream , Lanstream 2000, RTA8/RJX, RRC16, MTA8/RJX & SXDC8/RJX

Serial to Bluetooth Adapter

32 Transferring Projects and Data

INSTALLATION AND OPERATION MANUAL CNFE2DOE TERMINAL SERVER

Manual Serial PCI Cards

Single channel data transceiver module WIZ2-434

MODBUS TCP to RTU/ASCII Gateway. User s Manual

Connecting and Setting Up Your Laptop Computer

Vicon Flash Upgrade Software

Quick installation guide for the Vista Quantum QNVR Network Video Recorder

USR-TCP232-T Hard Version: V2.0 Doc Version: V

F2103 GPRS DTU USER MANUAL

Cable Specifications and Information

CM6700 Matrix Switcher/Controller

ISHIDA BC Scale to Scale Communications

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

RJ11 RS-232 Interface

T3 Mux M13 Multiplexer

Using a Laptop Computer with a USB or Serial Port Adapter to Communicate With the Eagle System

EMIC/MBA Ethernet M-Bus Metering Interface Controller

LOVELINK III- Process Monitoring, Logging, Graphing, & Configuration

Instructions on How to Use HyperTerminal to Test Serial Ports ...

Internet-bridge XPort

Introduction: Implementation of the MVI56-MCM module for modbus communications:

Table of Contents. Chapter1. Introduction Before Installation System Requirements... 1

Operation Manual of EX-9132C-2. Serial to TCP/IP Converter

Networking Alpha signs on a TCP/IP network

User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS

TCP/IP Converter DDS EX-9132 Operation Manual for 8051 Series

Quick Note 32. Using Digi RealPort with a Digi TransPort Router. UK Support September 2012

USB to RS-422/485 Serial Adapter

MCS-BMS-GATEWAY STARTUP GUIDE

MODBUS TCP to RTU/ASCII Gateway

One Port Serial Server Users Manual Model ESP901, ESP901E

Configuring the Switch with the CLI Setup Program

RN-XV-RD2 Evaluation Board

Installation and Operation Guide

Easy Setup Guide for the Sony Network Camera

Configuring the Switch with the CLI-Based Setup Program

3.1 RS-232/422/485 Pinout:PORT1-4(RJ-45) RJ-45 RS-232 RS-422 RS-485 PIN1 TXD PIN2 RXD PIN3 GND PIN4 PIN5 T PIN6 T PIN7 R+ PIN8 R-

SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual

OFF-LINE COMMUNICATIONS WITH CINCINNATI EQUIPMENT Pg. 1 of 5

ECcom. Signal Monitor Communications Software Operations Manual

Setup guide. point to point wall plate extenders

Transcription:

Router Connection Details Television Systems Limited. Vanwall Road, Maidenhead, Berkshire, SL6 4UB Telephone +44 (0)1628 676200, FAX +44 (0)1628 676299 1 Routers

Contents 1 GVG Encore / Prelude / Jupiter SMS 7000 Family Routers 2 Harris / Leitch Routers 3 Nevion / Network Routers 4 Pesa Routers 5 GVG Thomson/Philips/BTS Routers 6 ProBel Routers 7 Evertz / Quartz Routers 8 Sony Routers; MVS/DVS Series, 9 Sigma Routers 10 NVision Routers 11 Talia Routers Appendix 1 TallyMan Router support as at April 2008 Note: Please check pin functions with connector details published for the routers as these connections shown might be out of date. The routers have been added in the order that software requirements have arisen. V3.0 Oct 09 2 Routers

1 GVG Encore / Prelude / Jupiter & SMS 7000 Family Routers The cable details in the boxes refer to the cable connectors. In TallyMan be sure to set priority numbers for the active Router Buses and set the correct Level, with the ASCII code. The SMS7000 router needs an AMEZI serial interface to be installed. Start with Level 0 in the TallyMan settings. The system will only import the names that exist on the selected level. The level names can be viewed under "Edit Levels". The GVG Encore/SMS 7000 router is different from other manufacturers routers in that it uses only names to identify the following: levels inputs outputs. The TSL TallyMan Controller uses the names that are programmed into the router to deduce the cross point information. The TallyMan program will allow access to the up-loading of the router s names when the Read Names button is pressed in the screen. In the TallyMan program, in the Router Properties box menu item, the video level could show something like 0:128SDV The leading part of the names in the UMD Controller must match exactly the names in the router, including case, punctuation and spacing. The easiest way to ensure this has happened is to select Read Names and then import them to the UMD mnemonics. Allow a few moments (10~20 secs) for the update box to appear, when OK is pressed. However, if the Encore/SMS 7000 names are, say, only 5 characters long, any default name in the Edit router source names box e.g. SRCE 1, will not be completely overwritten. For example, the 1 part of SRCE 1 will remain. This is so user-mnemonics may be added to the TSL router lists as long as the leading names/mnemonics match those from the SMS7000. V3.0 Oct 09 3 Routers

Router Names may be copied across to the UMD mnemonics. Current software will overwrite the names entirely on a router upload but the user can then still enter the additional user-mnemonic part. e.g. CAM1 Bob Bob is the user- entered part of the mnemonic. CAM1 has been uploaded from the SMS 7000. This facility will be especially useful for 16 character displays. Connections The TallyMan Controller usually connects into the SMS 7000 router via the ASYNC I/F connector(s), depending on configuration of the SMS 7000. If more than one connector is fitted, it can configured either be as MAIN/STANDBY or as two separate control connectors. There may be one or two serial ports available on the SMS 7000. Either can be used, as long as the port is set correctly. The connector supports both RS232 and RS422 standards. The TallyMan Controller is fitted with an RS422 interface (connected as a Device), and is identified as a socket on the chassis. The Encore routers use a RJ45 connector. Cable details TALLYMAN CONTROLLER TM1/TM2 RS-422 GVG SMS 7000 ROUTER J1, RS-422 D25 plug 2 TX- 4 8 RX- 5 3 RX+ 3 7 TX+ 2 4, 6 GND 7 TALLYMAN CONTROLLER TM1/TM2 GVG SMS 7000 ROUTER RS-232 J1, RS-232 D9 D25 Socket 2 RX 3 3 TX 2 4 DTR 6/8 5 GND 7 7 RTS 4 8 CTS 5 V3.0 Oct 09 4 Routers

Encore Routers Also please see Notes below TALLYMAN CONTROLLER TM1/TM2 TALLYMAN CONTROLLER TMC-1 ENCORE FRAME 6100884XX RS-422 RS-422 COM 2, Serial 1-8 D9 Skt RJ45 2 1 TX- 6 8 4 RX- 8 3 3 RX+ 3 7 2 TX+ 1 4, 6 5 GND 4, 5 Check the configuration of the Encore for it to work with the UMD TallyMan Controller. Be sure to Set GVG Native or NP in the protocol selection box. The configuration is as follows. Communication details. Baud rate 9600 Parity NONE Stop Bits 1 Data Bits 8 Protocol NATIVE Notes With GVG Native Protocol, read the router names while online to achieve communications. Although the Encore does not provide an automatic update of status changes within the router, it is interrogated for changes that have occurred since the last request. This is done about 5 times a second, so a UMD display should respond within about ¼second. If the Comms are good between the Encore and the TallyMan Controller, and TallyMan is online when the router name database is changed, there should be an automatic update shown in TallyMan. Amendments for recent Encore Frames (July 2007) RJ 45 For Encore Frame 6100884xx 1 Rx+ 2 No Connect 3 Tx+ 4 Ground 5 Ground 6 Rx- 7 No Connect 8 Tx- RJ45 For Encore Frame 6101000xx 1 Tx+ 2 Tx- 3 Ground 4 Ground 5 Ground 6 Ground 7 Rx- 8 Rx+ V3.0 Oct 09 5 Routers

For Prelude - configured units Communication details. Baud rate 38400 Parity NONE Stop Bits 1 Data Bits 8 Protocol NP The cable required between the D9 connector on a Prelude-configured UCP is as follows: TALLYMAN CONTROLLER RS-422 TSL Functions GVG Prelude Panel 3 RX+ 7 8 RX- 2 4 SCN 4 7 TX+ 3 2 TX- 8 6 SCN 6 Twisted cable pairs are: 2 & 7 and 3 & 8. Screen shots of a panel configuration courtesy of GVG UK. V3.0 Oct 09 6 Routers

V3.0 Oct 09 7 Routers

2 Harris / Leitch Routers The cable details in the boxes refer to the cable connectors. The router cable is plugged into a RS422 Port on the TallyMan Controller. In TallyMan be sure to set priority numbers for the active Router Buses. Start with Level 0 set in the TallyMan dialog box. With a RS422 data/led checker, background polling on the communications link must be seen both ways at the rate of about once a second. The Leitch router acts as a Controller. These routers may connected to the TallyMan Controller via either a RS232 or a reverseconnected RS422/485 link. Cable Requirements TALLYMAN CONTROLLER TM1/TM2 RS-232 D9 LEITCH ROUTER D9 Socket 2 RX 3 3 TX 2 5 GND 5 TALLYMAN TM1/TM2 CONTROLLER RS-422 TSL Functions LEITCH ROUTER D9 Socket 3 RX+ 7 8 RX- 2 4 SCN 4 7 TX+ 3 2 TX- 8 6 SCN 6 For RS422 cables 2 & 7 and 3 & 8 are twisted pairs. Communication details. Baud 9600 / 38K4 No Parity 8 Bits 1stop Bit For Integrator models Set the Integrator Serial 1 Port on the Logic Module to RS422 by suitably fitting the links the correct way up. Set the baud rate for Serial Port 1 to 9600 - and Set RH Serial Port 1 Protocol switches 1 and 2 to Leitch (Auto Detect). For Leitch router levels 1 and 2 set the TSL levels in TallyMan to Levels 0 and 1 respectively etc. V3.0 Oct 09 8 Routers

Leitch VIA32 Router The cable details in the boxes refer to the cable connectors. The router cable is normally plugged into a Comms Port on the TallyMan Controller. In TallyMan be sure to set priority numbers for the active Router Buses. Leitch VIA32S series routing switchers. The control port on the TallyMan Controller should be fitted with an RS232 interface. This is identified as a D9 plug mounted on the rear of the TallyMan Controller. The SERIAL CONTROL connector on the rear of the LEITCH frame is connected to the TSL TallyMan Controller. The settings are as follows: Communication details. RS232 9600 baud 8 bit data No parity One stop bit The configuration DIP switches should be set as shown: (See Fig 2-5, P2-6 in the Leitch Installation & Maintenance Manual). S1 S2 On 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 S1-5 [ON] sets flow control on. S1-6 [ON] sets echo mode on. S1-7,8 [OFF] sets baud rate to 9600 Baud. An interface cable should be made up as below. TALLYMAN CONTROLLER TM1/TM2 D9 LEITCH ROUTER Serial Control Port D9 Socket 3 2 2 3 5 GND 7 During operation, TallyMan is listening for status messages from the LEITCH router, identifying the cross-points as they are made. In addition, the TallyMan carries out a background poll of the LEITCH router at the rate of 1 bus per second. V3.0 Oct 09 9 Routers

For Platinum Models Set the protocol in Tallyman as Leitch X-Y Passthrough. Set the router size in TallyMan Set up the appropriate matching communications parameters on the Harris PTR-RES Platinum Resource Module (card) and in TallyMan Set the Matrix number in TallyMan at 0 Initially set the Level number in TallyMan at 0 or check Multi Level and set the appropriate numbers on levels for the router. Using a Terminal program with the PC attached to the other Harris serial port will allow crosspoint changes to be made locally. Press Q to see the Command Summary screen When successfully On-Line, the Router Object will appear in TallyMan with a bright green dot alongside and activity will be seen in Tools > Router Mimic at the instant of a crosspoint change. Settings: 38K4/8/N/1. No Flow Control. Cable details TALLYMAN TM1/TM2 CONTROLLER RS- 422 TSL Functions HARRIS ROUTER D9 Socket 3 RX+ 7 8 RX- 2 4 SCN 4 7 TX+ 3 2 TX- 8 6 SCN 6 V3.0 Oct 09 10 Routers

3 Nevion / Network Routers The cable details in the boxes refer to the cable connectors. The router cable is plugged into a Comms Port on the TallyMan Controller. Correct protocol is the Nevion (VikinX) serial protocol If there is a checkbox labeled Routers are connected to this serial port, it should be unticked. In TallyMan be sure to set priority numbers for the active Router Buses. TallyMan Programming The Router Level is the same as the Router s Address. For example, if the Router Address is 0, the Level that must be set in the Tallyman Router Properties box is 0. All Midi data links must be fitted for operation. TallyMan Controller RS232 details TALLYMAN CONTROLLER RS 232 CONNECTORS D9 CONNECTOR 1-6 - 2 RX 7 RTS 3 TX 8 CTS 4 DTR 9-5 0v Cable Details TALLYMAN CONTROLLER TMC-1/TM1/TM2 RS-232 D9 Network Router RS-232 2 RX TX 2 3 TX RX 3 5 GND 5 Communication details. 19K2 for 16 x 16, 32 x 32 and 64 x 64. Early V 16 x 16 routers are 9600 Baud No Parity 8 Bits 1 Stop Bit The maximum cable length is 15m. Note To interface using the older MIDI based serial protocol, the TallyMan file should be set to Nevion (MIDI) with baud rate at 19200. The VikinX series routers need a port specifically configured for this older protocol. V3.0 Oct 09 11 Routers

4 Pesa Routers The cable details in the boxes refer to the cable connectors. The router cable is plugged into a Comms Port on the TallyMan Controller. In TallyMan be sure to set priority numbers for the active Router Buses. TallyMan Programming. The Router Level that must be set in the main screen in Router Properties Menu is 0. Be sure to set Router Bus priorities in TallyMan. Router Programming Open the CPU Link window. Select Port 2. Set the Baud Rate as 38400 Set the Stop Bits at 1 Select Protocol Type as USP. Set Check Sum as None. Set the Terminator as CR-Carriage Return Check all boxes in the Status Filter Select OK. Normal RS232 Connections Cable Requirements TALLYMAN CONTROLLER TM1/TM2 RS-232 D9 PESA RS-232 D9 Socket 1 + 6 --- 4 2 --- 3 3 --- 2 4 --- 1 + 6 5 GND 5 7 --- 8 8 --- 7 9 N/C 9 V3.0 Oct 09 12 Routers

Hardware Information PESA J13/J14 RS 232 Connectors on equipment FUNCTION 1 CD 2 RX 3 TX 4 DTR 5 GROUND 6 DSR 7 RTS 8 CTS 9 N/C Hardware Information PESA J15 Connector FUNCTION on equipment 1 GROUND 2 RX+ 3 TX- 4 GROUND 5 N/C 6 GROUND 7 RX- 8 TX+ 9 GROUND RS 422/485 Connections Cable Requirements TALLYMAN TM1/TM2 CONTROLLER RS-422 PESA ROUTER RS-422 D9 Socket 2 7 8 3 4 SCN 4 7 2 3 8 6 SCN 6 V3.0 Oct 09 13 Routers

TallyMan Programming General The Pesa router is different from other manufacturers routers in that it uses names and levels to identify the following: levels inputs outputs. TallyMan uses the names that are programmed into the router to deduce the cross point information. The TallyMan program will allow access to the up-loading of the router s names when the Configure Router Names button is pressed in main router screen. In the TallyMan program, in Router Properties, the Level could show something like 0:128SDV The leading part of the names in the Controller must match exactly the names in the router, including case, punctuation and spacing. The easiest way to ensure this is to force an Import Router Database Names to Mnemonics. This is achieved via the Read Names button. Allow a few moments (10~20 secs) for the update box to appear, when OK is pressed. User-mnemonics may be added to the TSL router lists as long as the leading names/mnemonics match those from the Pesa Router. Router Names may be copied across to the UMD mnemonics. V3.0 Oct 09 14 Routers

5 GVG Thomson/Philips/BTS Routers The cable details in the boxes refer to the cable connectors. The router cable is normally plugged into a Comms Port on the TallyMan Controller. In TallyMan be sure to set priority numbers for the active Router Buses. The Jupiter VM3000 needs to be programmed with a set of CP input and output tables, for the ASCII interface to the Controller (similar to setting up a control panel). This will allow which sources and destinations TallyMan looks at by compiling these tables. The ASCII protocol used does not support transfer of mnemonics between the Jupiter and third party Controllers; this is a limitation imposed by Philips. Routers Using BTS ASCII Interface In order for TallyMan to communicate with the router, the correct type of interface must be installed and configured inside the router main frame. One serial port, on the rear of the BTS control system must be allocated for use with TallyMan and configured as an ASCII port. The Source and Destination tables must be built for this port and the file saved back to configure the router. The connector supports both RS232 and RS422 standards. The serial interconnection cable between the BTS router and the TallyMan Controller should be wired as shown below. TALLYMAN CONTROLLER TM1/TM2 RS232 D9 BTS ROUTER ASCII PORT(7), RS232 D9 Socket 2 RX 3 3 TX 2 5 GND 1 + 6 + 7 V3.0 Oct 09 15 Routers

TALLYMAN CONTROLLER TM1/TM2 RS422 BTS ROUTER ASCII RS422 D9 plug 2 TX- 2 7 TX+ 7 4 GND 4 8 RX- 8 3 RX+ 3 6 GND 6 The BTS router serial port used by TallyMan needs to be set up as: Communication details. Baud Rate: 38K4 with ASCII interface Data bits: 8 Parity: None Stop bits: 1 Refer to the BTS Control system (Installation & Operation) manuals for details on: Hardware Installation... BTS ASCII 2-49 (computer interface protocol) Software Installation... Serial protocol 3-28 MPK devices 3-44 Notes. During operation, TallyMan initiates a Watch Output command, at the rate of 1 bus per second for each for each bus it is interested in. The router immediately replies with a status as well as responding to any changes on that bus. For the ASCII interface within the Jupiter config, you must define sets of inputs, outputs and levels and associate them with the ASCII configured port. The index numbers on the left of these sets determine the numbers sent in the ASCII protocol to TallyMan. If unsure of level number, then tick the "Multi Level" box in TM and specify e.g. 8 levels. It is, however normally preferable to operate as single level if you are only interested in one level, as it removes unnecessary compilations in subsequent programming. Note that only those levels specified in the CP Level set will appear on the interface. V3.0 Oct 09 16 Routers

6 Snell & Wilcox / ProBel Routers The cable details in the boxes refer to the cable connectors. In TallyMan be sure to set priority numbers for the active Router Buses. Problems with communication are invariably due to incorrect configuring of the ProBel port. Check whether the protocol set in the router is SWP02 or SWP08. System - General Setup Set the number of the router video and matrix levels. For General Remote Protocol, System 3 (SWP08), Aurora and Freeway, this starts at 00 (zero). For General Switcher protocol, System 2 (SWP02), this starts at 01. Check in the router manual for router matrix number setting. If there is doubt as to the correct number, start at 0. A control port on the TallyMan Controller is fitted with an RS422 interface; this is identified as a D9 socket. In order for TallyMan to communicate with a router, it is necessary for the correct type of interface to be installed and configured inside the router main frame. ProBel routers need to have a Remote (communications) Port assigned and configured to act as an interface to TallyMan. In order to achieve this, a computer terminal needs to be connected to the router maintenance interface port and the router configured to the following specification: Communication details. General Remote Protocol SWP08 / General Switcher Protocol SWP02 RS422 38400 baud 8 bit data No parity One stop bit Set the Remote Port to be General Remote or General Switcher protocol, as appropriate. ProBel port RS485/422 should be used. The serial interconnection cables between the PROBEL router and the UMD TallyMan controller should be wired as shown below for the particular application. V3.0 Oct 09 17 Routers

Pin-out Details RS232 Connections where appropriate TALLYMAN CONTROLLER PROBEL ROUTER Control Port D9 D9 Socket 3 (Tx) 3 2 (Rx) 2 5 (0v) GND 5/7 General Switcher protocol SWP02. RS422 Connections where there is a ProBel controller in the system. TALLYMAN CONTROLLER TM1/TM2 PROBEL ROUTER Control Port D9 plug 3 3 8 8 7 7 2 2 4,6 GND 6,4 General Remote protocol SWP08. RS422 Connections where there is a ProBel controller in the system. TALLYMAN CONTROLLER TM1/TM2 PROBEL ROUTER Control Port D9 plug 3 7 8 2 7 3 2 8 4,6 GND 6,4 V3.0 Oct 09 18 Routers

RS422 Connections where there is no ProBel controller in the system. TALLYMAN CONTROLLER TM1/TM2 PROBEL ROUTER Control Port D9 plug 3 3 8 8 7 7 2 2 4,6 GND 6,4 During operation TallyMan is listening for status messages from the ProBel router identifying the cross-points as they are made. In addition, TallyMan carries out a background poll of the ProBel router at the rate of 1 bus per second. For routers on different levels, an extra Router module will need to be inserted into the TallyMan tree and assigned to the existing one for the communications connections. Note: In case of no communications with the ProBel frame, please be prepared to try a 1:1 cable or crossed cable, as the case may be. Also, check the matrix level numbers set in TallyMan. V3.0 Oct 09 19 Routers

7 Evertz / Quartz Routers The cable details in the boxes refer to the cable connectors. The router cable is plugged into a Comms Port on the TallyMan Controller. In TallyMan be sure to set priority numbers for the active Router Buses. The Quartz routers, Q1600/Q3200, may not have a suitable serial interface installed and it must be fitted retrospectively if the routers were ordered without the interface board. The router serial interface may be configured as RS232 or RS422 by changing the position of the jumpers on the card. All jumpers must be set the same way. See the following charts for connection details. TALLYMAN CONTROLLER TM1/TM2 RS-232 D9 QUARTZ ROUTER RS-232 2 RX 7 3 TX 3 5 GND 6 TALLYMAN CONTROLLER TM1/TM2 FROM TALLYMAN QUARTZ ROUTER RS-422 3 RX+ 7 8 Rx- 2 4 0v 4 7 Tx+ 3 2 Tx- 8 6 0v 6 The TallyMan Controller uses the default serial communication settings of the Quartz router. Use Quartz protocol (Quartz Type 1 or Quartz Native). Communication details. 9600 / 38K4 baud (depends on version) 8 bits No parity 1 stop bit Note: The Matrix setting in TallyMan has no effect with Quartz Routers. If you have difficulty with finding the correct Level, check the Multi-level box in the TallyMan router dialog page and enter, say 4, in the Levels box. Then inspect the data in Tools > Tally Mimic to ascertain which level you want to read. V3.0 Oct 09 20 Routers

Courtesy of Evertz Quartz UK V3.0 Oct 09 21 Routers

8 Sony Routers MVS/DVS Series The cable details in the boxes refer to the cable connectors. The router cable is plugged into a Comms Port on the TallyMan Controller. In TallyMan be sure to set priority numbers for the active Router Buses. The communication is RS422 and operates at 38K4 baud. ROT 16 is supported TALLYMAN TM1/TM2 CONTROLLER RS-422 SONY ROUTER RS-422 3 7 8 2 4 SCN 4 7 3 2 8 6 SCN 6 The protocol is multi-drop, allowing multiple devices to be on the bus. This allows for several routers to be controlled, or monitored from one serial port. Addressing on the Sony equipment is by means of a DIP switch. This address is designated Unit Address 2. Addressing is bit mapped. This allows operations to take place on more than one router at a time, i.e. Video + Audio etc. In the TallyMan Controller, the address is set by using the Video Level number and the addresses generated are as follows:- TALLYMAN CONTROLLER VIDEO LEVEL DECIMAL SONY UNIT ADDRESS 2 HEXADECIMAL 1 1 0x01 2 2 0x02 3 4 0x04 4 8 0x08 5 16 0x10 6 32 0x20 7 64 0x40 8 128 0x80 This facility precludes an automatic update from the router to the TallyMan Controller. This normally provides a quick update when a change occurs. With 16 or less outputs and inputs, the complete status can be requested and this is done twice a second to keep display update time reasonably short. Set the IP address to be in the same group as the TallyMan TMx unit. The Port in TallyMan must be set to 8004. Assign a spare SBUS number to the TM system. V3.0 Oct 09 22 Routers

9 Sigma Routers Please check on the pin functions as shown in the manuals for the correct connectivity. Usually RS 232: Pin 2-3 Pin 3-2 Pin 5-5 Baud rate is fixed at 9600 in TallyMan. Switches will need setting in the MRX Router The MRX Router module is RS232 by default. Its logical address is 0 which corresponds to Matrix number 0 in the TallyMan program Handshaking should be set to OFF. Sigma Switch Settings: RS232 Baud Rate setting: S2-1 and S2-2 ON /DOWN Protocol format: S2-9, S2-10. S2-11 ON/DOWN Control Level: S2-12 DOWN/ON (8 Levels) Handshaking S3-2 OFF/UP 10 NVision Routers Connect using TCP/IP The level number corresponds to the physical level number (-1) in the NVision software. For multiple levels, each level should be entered as a separate router object, communicating with the same IP/port on the NVision router. V3.0 Oct 09 23 Routers

11 Talia Routers Select the correct protocol in TallyMan. Set the Communications. Note. For this high baud rate, Control Ports 1, 2 or 3 must only be used on the TMx. V3.0 Oct 09 24 Routers

Typical Comms details for the Geneous CPU Baud Rate: 57600 Parity: None Data: 8 Stop Bits: 1 Cable details D25 Plug Aux to CPU D9 Socket PC9 to TallyMan Port 3 RS232 Pin Number Pin Number 1-2 2 3 3 4-5 7/8 6-7 5 8-9 - 10-11 - 12-13 - 14-15 - 16-17 - 18-19 - 20-21 - 22-23 - 24-25 - TallyMan can control the router. V3.0 Oct 09 25 Routers

Appendix 1 TallyMan Router support as at July 2008 Protocol Control Alphanumeric BTS ASCII Yes No GVG Native Yes From Router BTS ESSwitch Yes From Router Kramer Yes No Leitch Yes No Nevion Yes No NVision Yes From Router Pesa Yes From Router Quartz Yes From Router SBUS (ROT16) Yes From Router Sigma Yes No Sony Yes No SWP02 Yes No SWP08 Yes From Router Talia Yes No VikinX Yes No V3.0 Oct 09 26 Routers