SERVICE. MXL Series. Pyrotronics. Cerberus Division, Siemens



Similar documents
MXL-IQ Advanced Life Safety System

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

FA-300 Series. LCD Fire Alarm Control Panel. User Guide. LT-954 Rev. 0.1 February FA-300 SERIES Fire Alarm Control Panel

SECTION DETECTION AND ALARM

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM S7010 S :111

INTELLIGENT FIRE ALARM CONTROL UNITS MMX-MNS TM

SFC-200 SERIES LCD FIRE ALARM PANEL

Life Alarm Fire Alarm Controls

Fire Control Panels. Remote Annunciator Panels. UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Features. Introduction

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

PRT3 Printer Module: ASCII Protocol Programming Instructions

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

Destiny Destiny Owners Manual

FireSeeker Fire Alarm Control Panel Model FS-250 Programming Manual

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

Using your LED Plus keypad

Fire Control Panels Series Remote InfoAlarm Command Center for the 4010ES Fire Alarm Control Panel

Control/Communicator Installation Manual

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Specifications Control Features. User Interface. Communicator. Programmable Outputs. Access Control. System Response

SECTION FIRE DETECTION AND ALARM SYSTEM PART 1 - GENERAL 1.01 DESCRIPTION

DTW Works Master Specification Version 2006

NETWORK FIRE ALARM CONTROL PANEL. Features S7010 S :111

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

FIRE ALARM AND EMERGENCY VOICE EVACUATION SYSTEM

CATALOG NUMBER. Features. Description

GE Concord 4 Quick User Guide

INTRUSION DETECTION SYSTEM Section

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

DESTINY 1/19/96 # A

Panel Controller MPC-xxxx-B FPA-1200-MPC. Operation guide

IDS X-Series User Manual D Issued July 2012

SECTION FIRE ALARM SYSTEM

DESTINY OWNER S MANUAL

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

EST io64 and io500 Technical Reference Manual

Elite 8D/Lite Version 8 Zone Controller. Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

D7024 Fire Alarm Control Panels Software Version V2.06

A.1. a Division of Pittway Corporation. Documento: M MGAS-ENG. Edizione: 01/1997 Rev.:

FIRE ALARM AND VOICE COMMUNICATION SYSTEM Request for Qualifications

DIALER SPECIFICATION VERBATIM MODULAR SERIES VSS

NC State University Design and Construction Guidelines Division 26 Fire Alarm Systems

FIRE DETECTION AND ALARM

Operating the DS9400 Fire Alarm Control/Communicator

Programming Logic controllers

Installation Instructions & Owner s Operation Manual for Two to Eight Zone 2400 Series Fire Alarm Control Panels

Quick Installation Guide LCD GSM ALARM SYSTEM LH

Business/Home GSM Alarm System. Installation and User Manual

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

Operating Guide. Alert 8D Version 8 Zone Controller Arrowhead Alarm Products Ltd

APR-PRT3 Printer Module: C-Bus Programming Instructions

Design and Construction Standards SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

Contact ID as of 2/2/2015

FIRE ALARM SYSTEM Section Page 1

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

SECTION FIRE ALARM AND DETECTION SYSTEM

CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS

TrueAlarm Fire Alarm Controls

SECTION ( ) FIRE DETECTION AND ALARM SYSTEM

Expansion Modules & Accessories

Conventional Fire Detection and Extinguishant Control System Specification

FVSU REPAIR & UPGRADE FIBER OPTIC SECTION FIRE ALARM SYSTEM CONNECTIVITY

Simon XTi Quick Operation Guide

SECURITY SYSTEM MANUAL

TrueAlarm Fire Alarm Systems

2 4PI175 issue 1_6/01. How to unset system in alarm. Programs 1, 2 and 3. Access codes. How to operate Personal Attack

Users Guide to Keypad Functions

ARCHITECT AND ENGINEER SPECIFICATION SECTION DETECTION AND ALARM SECURITY ACCESS AND SURVEILLANCE. DSC MAXSYS PC4020 V3.

CA60 Plus Software Version 3.1 User Manual May 2000

FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM

PowerWave-8. Users Operating and Programming Guide Version zone Control panel Communicator

FIRE. 4100U Fire Alarm. Operator s Manual. Operator's Manual. Operator s Manual. LT0395 Iss 1.0

tattletale User Guide Consumer unit version P a g e

How to read this guide

4005 Fire Alarm Front Panel Programming Instructions

IDS. Users Guide to Keypad Functions S E C U R I T Y MANUAL NO B ISSUED AUG 2002 VERSION 1.18

User s Information Guide R1A

Program Entry Guide. Control Panels

A. This Standard outlines the requirements for an addressable fire detection and alarm system.

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

New GSM Alarm System. User s Manual. Profile For a better understanding of this product, please read this user manual thoroughly before using it.

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

LEN s.r.l. Via S. Andrea di Rovereto 33 c.s CHIAVARI (GE) Tel Fax mailto: len@len.it url: http//

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

System Introduction S E C T I O N 1

Fire Alarm System Plans Review Checklist Property location Date of Review

9452/9453 Installation and User Guide

Ademco Vista-20P/First Alert FA-168C Basic Commands

510 / 511 Cardiorespiratory Monitor Preventative Maintenance Test Procedure

GC2 Panel User Guide

TABLE OF CONTENTS FEATURES 2 SPECIFICATIONS 2

FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS

CAPTAIN 6. USER GUIDE System ver Zones Intruder Alarm System. PIMA Electronic Systems Ltd.

CONTENTS 4. HOW TO UNSET THE PANEL...7

SECTION FIRE ALARM AND DETECTION SYSTEMS

SECURITY SYSTEM NOTES. EMERGENCY ACTIVATION KEYS (check if enabled) PROGRAMMED FUNCTIONS

ELECTRONIC ENGINEERING LTD. Runner Series WIRELESS AND WIRED CONTROL PANEL. User s Guide

FIRE DETECTION Note: Your installer must enable the fire detection portion of this equipment before it becomes functional.

Driver Manual (Supplement to the FieldServer Instruction Manual) FS (Notifier NFS-640 NFS-320 NFS2-640)

Transcription:

MXL Series Pyrotronics Cerberus Division, Siemens

MXL Control Panel Advanced fire protection control panel Multiplexed Alarm Reporting Custom Site Specific Custom Programming Basic Panel Contains: Two Addressable Loop Two NAC Circuits Three System Relays (Alarm, Trouble, Supervisory) Additional MOM-4 Motherboard Additional System Modules, Input or Control Outputs

MXL Series MXL Basic Addressable System MXLV Addressable System with Integrated Voice Features MXL-IQ Standard MXL system with Limited Point Capacity Network All of the above systems can be Integrated into a Network

ENTER HELP PRINT FORM FEED CLEAR SERVICE System Configuration Original Back Box Tan ALARM POWER MMB-1 Main Control Board AUDIBLES SUPERVISORY TROUBLE SECURITY NEXT PARTIAL SYSTEM DISABLE HOLD ALT 1 ALT 2 2 Addressable Loops (120 Devices) 1 2 3 4 5 6 7 8 9 0 ALT 1 ALT 2 F1 F2 F3 F4 FCT FCT FCT 2 NAC Circuits (1.5 Amps Each) TSP-40 MOM-4 Motherboard 4 Half Width Modules MOM-4 PSR-6/12 2 Full Width Modules Capable of Holding 2 Addressable Modules 2 Addressable Loops per Each Module (240 Devices Total) TSP-40 Thermal Strip Printer

ENTER HELP PRINT FORM FEED CLEAR SERVICE System Configuration Original Back Box Tan ALARM AUDIBLES SUPERVISORY TROUBLE SECURITY NEXT POWER PARTIAL SYSTEM DISABLE HOLD ALT 1 ALT 2 MMB-1 Main Control Board 2 Addressable Loops (120 Devices) 1 2 3 4 5 6 7 8 9 0 ALT 1 ALT 2 F1 F2 F3 F4 FCT FCT FCT 2 NAC Circuits (1.5 Amps Each) MOM-4 2 MOM-4 Motherboards 8 Half Width Modules MOM-4 PSR-6/12 4 Full Width Modules Capable of Holding 2 Addressable Modules 2 Addressable Loops per Each Module (480 Devices Total)

ENTER HELP PRINT FORM FEED CLEAR SERVICE System Configuration Current Back Box Black ALARM POWER MMB-1/2 Main Control Board 1 2 3 4 5 6 AUDIBLES SUPERVISORY TROUBLE SECURITY ALT 1 PARTIAL SYSTEM DISABLE NEXT HOLD ALT 1 ALT 2 FCT FCT FCT F1 F2 2 Addressable Loops (120 Devices) 7 8 9 0 ALT 2 F3 F4 2 NAC Circuits (1.5 Amps Each) 2 MOM-4 Motherboards MOM-4 MOM-4 TSP-40 8 Half Width Modules 4 Full Width Modules Capable of Holding 2 Addressable Modules 2 Addressable Loops per Each Module (480 Devices Total) PSR-6/12 TSP-40 Thermal Strip Printer

ENTER HELP PRINT FORM FEED CLEAR SERVICE System Configuration Current Back Box Black ALARM POWER MMB-1/2 Main Control Board 1 2 3 4 5 6 7 8 9 0 AUDIBLES SUPERVISORY TROUBLE SECURITY ALT 1 ALT 2 PARTIAL SYSTEM DISABLE NEXT HOLD ALT 1 ALT 2 FCT FCT FCT F1 F2 F3 F4 2 Addressable Loops (120 Devices) 2 NAC Circuits (1.5 Amps Each) 3 MOM-4 Motherboards MOM-4 MOM-4 MOM-4 12 Half Width Modules 6 Full Width Modules PSR-6/12 Capable of Holding 2 Addressable Modules 2 Addressable Loops per Each Module (720 Devices Total)

MXL Control Panel Continuous System Supervision Microprocessor Based Polling System Degrade Operation Enhances system reliability in case of main CPU failure System Outputs: Programmable Output Operation Cabinet Mounted Outputs Addressable Filed Devices with Control Capability

Basic System Components MMB-1/2 Main System Board MPS-6/12 System Power Supply MKB-1 System Keyboard/Annunciator TPS-40 Thermal Strip Printer MBR-1 Back box MDR-1 / MDR-1P Door Plain or with Printer View port Batteries

MMB Main System Board 16 - bit CPU with EPROM / RAM Memory Storage Watchdog circuitry for CPU Operation Flash memory for the CSG-M (System Specific Program) Network Interface for Transponders or Peer-to-Peer Operation Back-Up Battery Capability up to 60 Amp Hours 24VDC Regulator for Internal System Power Requirements Field Power is Unfiltered with Minimal Rectification AC Transfer Relay for Continuous Operation

MMB Main System Board Class A Power for CZM-1 Field Modules 24 VDC unregulated supply Two Analog Loops Initiating and Control Devices on the Same Loop Two Indicating Appliance Circuits Class A or Class B Operation Three Form C Relays Alarm, Trouble and Supervisory

System Power Supplies MPS-6 Power Supply Supervised power supply 6.5 Amp, 24 VDC unregulated output MPS-12 Power Supply Supervised power supply 12.5 Amp, 24 VDC unregulated output Transponder Power Supply

MKB Keyboard/Annunciator 12 00 00 JAN 01 1990 SYSTEM - - - CERBERUS PYROTRONICS SYSTEM MXL NORMAL ALARM POWER AUDIBLES SUPERVISORY PARTIAL SYSTEM DISABLE TROUBLE NEXT HOLD SECURITY ALT 1 ALT 2 FCT FCT FCT 1 2 3 4 5 6 HELP PRINT ALT 1 F1 F2 FORM 7 8 9 0 ENTER FEED CLEAR ALT 2 F3 F4

MKB Keyboard/Annunciator Annunciator and manual control panel for the MLX 2 - line 80 character alphanumeric display System Indicators: Power indicator (Green) Alarm indicator (Red) Audibles silenced (Red) Supervisory indicator (Yellow) Trouble indicator (Yellow) Security indicator (Yellow) Point disabled (Yellow)

MKB Keyboard/Annunciator The Keypad contains the following keys: ACKnowledge AUD SIL (Audible Silence) RESET NEXT display HOLD display Numeric keys Cursor Controls PRINT, HELP and CLEAR keys User configurable function keys

MKB Keyboard/Annunciator MKB-1 - MXL Display/Keyboard This unit is used on the original version of the MXL system, GREY backbox. The display mounts with stand off legs to bolts on the back of the main backbox. MKB-2 - MXL Display/Keyboard Hinged This unit is used on the current version of the MXL system, BLACK backbox. The display is hinged for wiring access MKB-3 - MXL Display/Keyboard for 19" Rack Mounting This unit is used when the MXL system is installed in a Rack mount enclosure. For this configuration the MKB-RK Rack Mount Bracket must be used. MKB-4 - MXL Display/Keyboard Hinged for IQ This unit is used on the MXL-IQ system. The display is also used with the XL3 system upgrade kit to a MXL system configuration.

TPS-40 Thermal Strip Printer Located within the Cabinet Back Box System Connections NOT Supervised Supervised Through Power Connection Provides paper record of the activity of the system Historical Logging All Events

Basic System Modules MMB-1/2 Main System Board MOM-2/4 Motherboard, Card Cage CSM-4 Signal Module CRM-4 Relay Module CZM-4 Conventional Zone Module ALD-2/2I Analog Loop Driver XLD-1 Analog Loop Driver (XL3 Devices) PSR-1 Remote Power Supply

External Communicating Modules RCC-1/1F Remote Command Center NET-4/7 Communication Interface NET-7M Communication Interface NIM-1R Network Interface Module REP-1 Network Repeater Module PS-5N7 Network Interface/5V Power Supply MOI-7 Voice and Annunciator Driver MOD-16 Output Driver MID-16 Input Driver

Voice System Modules CMI-300 Interface Module ACM-1 Audio Control Module TMM-1 Telephone Master Module MMM-1 Microphone Master Module VSM-1 Voice Switch and LED Module VLM-1 Voice LED Module VFM-1 Fan Control Module TBM-2 Termination Block Module OMM-1/2 Output Master Module

Voice System Modules Cont. ASC-1 Amplifier Supervision and Backup Card ASC-2 Amplifier/Riser Supervision and Backup Card OCC-1 Output Control Card BTC-1 Backup Tone Card RCM-1 Riser Control Module ZAC-30 Zone Amplifier Card DMC-1 Digital Message Card ZC Zone Control Card Modules (Series of Output Cards) ZCT-8B Zone Card Telephone

MOM-4 CARD CAGE Contains four option slots Four half width cards Two full width cards Two power connectors Two data connectors MXL system can accommodate up to two MOM - 4 card cages in a single enclosure. As long as there is no TPS-40 Printer installed

CSM-4 Signal Module CONTROLLABLE SIGNAL MODULE CSM-4 (INDICATING APPLIANCE CIRCUITS) CSM-4-2 STYLE Y OR STYLE Z CIRCUITS - 1.5 AMPS EACH - MARCHTIME, TEMPORAL, CODED OUTPUT - CONFIGURABLE FOR CITY CONNECTION - SILENCEABLE OR NON-SILENCEABLE - PROGRAMMABLE DEGRADE OPERATION - 2 OPEN COLLECTOR OUTPUTS - DIAGNOSTIC, USER-PROGRAMMABLE LEDS

CRM-4 Relay Module Output Control module with four relay outputs Form -C contacts rated at 2A, 30 VDC or 120 VDC

CZM-4 Conventional Zone Module CONVENTIONAL ZONE MODULE CZM-4 (INITIATING DEVICE CIRCUITS) CZM-4-4 STYLE B OR STYLE D CIRCUITS - SUPPORTS RELAY AND AUDIBLE BASES - DIAGNOSTIC, USER-PROGRAMMABLE LEDS - DEGRADE MODE OF OPERATION

ALD-2I Analog Loop Driver - 60 ADDRESSABLE DEVICES PER CIRCUIT - STYLE 4 OR STYLE 6 WIRING - 2 SIGNALING LINE CIRCUITS PER ALD-2 ALD-2 ANALOG LOOP DRIVER MODULE ALD-2 (MAPNET II ADDRESSABLE MODULE)

PSR-1 Remote Power Supply Microprocessor controlled remote power supply and battery charger Allows expansion from 360 to 3000 points Operates with the MPS -6 to provide 6 Amps of power for various MXL modules Provides an interface between remote modules and the MXL when used with a NET - 4 plug-in communications module

PSR-1 Remote Power Supply Can be used to power a MOI/MOD annunciator driver set Provides auxiliary power in a stand alone mode without an MXL 9 Status Indicators Two relays Common alarm and trouble Can be programmed for local alarm and trouble

NET-4/7 Communication Interface Communication between the remote PSR-1 panels and the main MXL Each NET-4 connected represents one network drop on the MXL system. Can have up to 32 network drops, including the MMB-1

ALARM AUDIBLES SUPERVISORY TROUBLE SECURITY NEXT HOLD POWER PARTIAL SYSTEM DISABLE SERVICE NET-4/7 Communication Interface EXPANSION? MXL CPU MXLR CERBERUS PYROTRONICS CERBERUS PYROTRONICS

MOI-1 Voice and Annunciator Driver Connects an MXL to: CVP90 Voice Alarm System (using VPM - 5s) EVACs Voice Alarm System (using VPM - 5s) Graphic Annunciator (using MOD - 16s) Makes a voice system with 120 speaker zones and/or a total of 128 open collector outputs controlled by logic functions in the CSG M Flashing XMT LED for normal TBL led on steady when in trouble

MOD-16 Output Driver Annunciator driver module controlled by the MOI-1 Up to 8 MOD-16s can be used with an MOI-1 Each MOD-16 can activate up to 16 outputs for a total of 128 outputs

MID-16 Input Driver Input control driver module controlled by the MOI-1 Up to 8 MID-16s can be used with an MOI-1 Each MID-16 can activate up to 16 outputs for a total of 128 outputs

Intelligent/Analog Devices Analog functionality Four levels of sensitivity for original devices Low, Normal, Med, High Sensitivity stored in chip located in head Sensitivity changed based on time of day Changed manually from control panel Automatic maintenance alert

Device Addressing Programming for intelligent devices is performed on a device basis in the field. Uses FPI - 32 PROGRAMMER/TESTER Resembles a laptop Used to program/test all intelligent devices

Device Addressing Cont. All modules and devices are annunciated on the MXL front display and are identified by a unique address (XXX-YYY) Each address has two parts The module address (XXX) may be up to 253 The device address (YYY) may be up to 249

Operating Instructions MKB-1 KEYBOARD/ANNUNCIATOR PANEL 12 00 00 JAN 01 1990 SYSTEM - - - CERBERUS PYROTRONICS SYSTEM MXL NORMAL ALARM POWER AUDIBLES SUPERVISORY PARTIAL SYSTEM DISABLE TROUBLE NEXT HOLD SECURITY ALT 1 ALT 2 FCT FCT FCT 1 2 3 4 5 6 HELP PRINT ALT 1 F1 F2 7 8 9 0 ENTER FORM FEED CLEAR ALT 2 F3 F4

Operating Instructions Cont. The Main System Display Two lines of 40 characters each Shows the current state of the system Back light turns on automatically when keypad is touched, turns off after 5 minutes of inactivity

Operating Instructions Cont. ALARM ACK - to acknowledge a fire alarm condition AUD SIL - to silence or unsilence an indicating appliance circuit SUPV ACK - to acknowledge a supervisory condition TRBL ACK - to acknowledge a trouble condition SEC ACK - to acknowledge a security condition Reset - to reset the system

Operating Instructions Cont. LED Indicators ALARM - Flashes when there is at least one unacknowledged fire alarm, steady when all alarms are acknowledged AUDIBLE SILENCED - Flashes when at least one indicating appliance circuit is active, steady when all silencable IACs are silenced SUPERVISORY - Flashes when there is at least one unacknowledged supervisory, steady when all are acknowledged

Operating Instructions Cont. LED Indicators TROUBLE - Flashes when there is at least one unacknowledged trouble, steady when all are acknowledged SECURITY - Flashes when there is at least one unacknowledged security, steady when all are acknowledged POWER - Indicates that power is on, steady when on AC, flashing when on battery PARTIAL SYSTEM DISABLE - at leas one device is disabled

Operating Instructions Cont. Menu Structure The system Menu allows in depth operation and control of the MXL system. The Menu option is entered by pressing the ENTER key. The Right and Left Hand Arrow Keys are used to select the desired Menu. The Menus are configured for Password Protection Acknowledge No Password Required List No Password Required Control Level 2 Password Required (Default 22222) Test Level 3 Password Required (Default 33333) Walktest Level 3 Password Required (Default 33333) Original system firmware versions had Walktest under TEST

Operating Instructions Cont. Acknowledge Menu Acknowledge Menu Alarm (Allows Acknowledgment of Alarms Only) Supervsry (Supervisory Conditions, Allows Acknowledgment of Alarms Only) Trouble (Allows Acknowledgment of Troubles Only) Security (Allows Acknowledgment of Security conditions Only)

Operating Instructions Cont. List Menu The List Menu allows the user to either view a specific system list on the MKB display or print the list on the system printer.

List Menu Operating Instructions Cont. List Menu Status Alarm Supervsry (Supervisory Conditions) Trouble Security Senstvty (Device Sensitivities) Voltages (Device Operational Voltages) Analog Thresh (Threshold for Alarm) Senstvty (Device Sensitivity) Calib (Device Calibration for XL Series Devices) ID (Device Identification for XL Series Devices) ID2 (Device Identification 2 for XL Series Devices)

Operating Instructions Cont. List Menu List Menu Cont. Mod_type (Module Type) Dev_type (Device Type) Message (Device Specific Message) SW_version (SoftWare and Programming Information) Output_states (Current States of Addressable devices) Dev_usages (Device Usage from System Programming) Node_address (Current Node Location) Percent/ft Senstvty (Sensitivity) Pre_alarm Analog ASD_apps (Programmed Device Application) Disarmed_state (Current Alarm State of a Disarmed Device)

Operating Instructions Cont. Control Menu Control Menu Reset (System Reset) Senstvty (Change detector Sensitivity) Arm/dis (Arm or Disarm an addressable device) Arm Disarm Output_on/off (Arm/Disarm and Turn On/Off an Output) Arm Disarm Energize De-energize

Operating Instructions Cont. Control Menu Control Menu Cont. Loop_arm (Arm an Addressable Loop) Loop_disarm (Disarm an Addressable Loop) Net_Link_Request (Used to Request a Node Disconnect) Percent/Ft (Used to Change Detector Sensitivities) Sensitivity Pre_alarm Change_Apps (Used to Change Application Specific Ops)

Operating Instructions Cont. Test Menu Test Menu Set_time (Set Time in 24 Hour Format) Gnd-flt (Ground Fault Report per Cabinet Location) Main Remote Power (Cabinet Power State, AC and Batteries) Main Voltage Current Remote Voltage Current Options MKB1_Lamptest (Front Display Lamp Test) LEDs Display

Operating Instructions Cont. Test Menu Test Menu Cont. Device_LED (Manual Activation of a Device LED) MOI_Lamp_Test (MOD-16 Output Functional Test) PAX_Lamptest (XL Series Annunciator Lamptest) ACM_Lamptest (Voice System Controls Lamptest) X_Network (Network Communication Data) M_Network (Network Communication Data) NET7_Diags (Network Module Trouble Reporting Information) Override (Overrides Alarm Verification and Confirmation) Det_cleaned (Indicates a Detector has been Cleaned)

Operating Instructions Cont. Test Menu Test Menu Cont. Event_log (System Information from the History Log) Alrm_only (Alarm Conditions Only) Trbl_only (Trouble Conditions Only) Superv_only (Supervisory Conditions Only) Security_only (Security Conditions Only) All_events Pyro_Diags (System Diagnostic, Factory Password Required) Pre_alarm (Used to Test System Pre-Alarm Logic) ASD_Devices (Disables Application Specific Operation for Testing of devices) Summarize (Used to Limit Module Troubles during Start-Up) Manual_Activate (Used to Test System Programming Logic)

Operating Instructions Cont. Walktest Menu Walktest Menu System_wAUD (Total System Test with Audibles) Loop_wAUD (Specific Addressable Loop with Audibles) Zone_wAUD (Specific Hardwired Zone with Audibles) System_SIL (Total System Test with NO Audibles) Loop_SIL (Specific Addressable Loop with NO Audibles) Zone_SIL (Specific Hardwired Zone with NO Audibles) Cancel (Used to Cancel condition Before Timeout) Extend Used to Extend the Test Time