I-Line - Snap-On Feature



Similar documents
V-joint fascia soffit systems

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1

FLASHMAN WINDOW AND DOOR FLASHING SYSTEM. Product. Scope. Appraisal No. 573 [2013]

The compliance of a roof to part of a new house at 28D Rata Street, Oxford, Waimakariri

Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide

SECTION PREFORMED METAL STANDING SEAM ROOFING

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

Installation Window Building In Details

NRG 75 CRF NRG GREENBOARD WALL SYSTEM

SECTION GUARDA SECURITY WINDOW SCREENS

PRODUCTBLADEN GT ROCKPANEL STRUCTURE

ALUMINIUM. Product Data Sheet

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

PROPOSED SPECIFICATION FOR ALUCOBOND PLUS Aluminium Composite Panel Cladding System Fixed Watertight Cassette Panel System - 4mm thick

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

Multi-layer Insulation Blanket for Roofs

Confort 26. Sliding Systems. Sapa Building System

Rooflight INSTALLATION INSTRUCTIONS

K17.12 Door closers K17. Doors

Colonnade Security Pipe

SECTION STANDING SEAM METAL ROOF

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems

Aluminium Fascias and Soffits

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS

Holiday Inn Express & Suites Covington (Newton County) 1. Standing-seam metal roofing, custom fabricated.

Product Data Sheet ROCKPANEL Rockclad

There s a LYSAGHT walling solution to suit every Australian building. Walling Solutions 2PF300 PAGE 1

Installation Detailed installation instructions are provided which should be strictly followed.

Fire Resistant Systems

Preformed Metal Roofing and Siding

STEP-BY-STEP. construction guide. Delivering better priced Conservatories, Sun Lounges and Garden Rooms via the Internet.

K17.11 DOOR BOLTS K17 DOORS

Plaisance 24. Sliding Systems. Sapa Building System

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

When considering Roof drainage design the following should be taken into account:

Laminar Flow Panel. Type LFP 2/2.4/B/2. Telephone +44(0) Telefax +44(0)

The formation of roof waterproofing details calls for

System 5000 FLAME-FREE, FELT SYSTEM, INSTALLED USING HOT AIR, TOTALLY ELIMINATING FIRE RISK AND PROVIDING A BITUMEN ALTERNATIVE TO SINGLE PLY

Wren Kitchens Installation Tips Carefully check your kitchen delivery Measuring out and marking up Fitting the base cabinets...

Asphalt Shingle Application Requirements

comar1,3,4 & 8 Ground Floor Treatment Innovative, integrated aluminium ground floor framing suites.

DIY CABINET REFACING INSTALLATION GUIDE

CONTE NT DESIGN PROCESS. Appendix. 01 First Issue. 02 Revision A. 03 Revision B. 04 Co-ordination. 05 Panel Thicknesses. 06 Panel Surface Quality

7. Installation. installation CAST-IN WINDOW SYSTEM 7.1. INSTALLATION OF WINDOW MAIN FRAME

Peninsula Place, Greenwich, London

Product Data Sheet PDS050: ArmourFX polished plaster and decorative paint panels

Window Installation Instructions

SECTION STANDING SEAM METAL ROOFING

Profiles in stock Standard catalogue. Discover the possibilities with aluminium profiles from Sapa

Hanson Building Products. precast basement solutions

KITCHENS. Tip PAGE 1 FITTING YOUR KITCHEN GUIDE. How to mark out a kitchen. Tools required for installing a kitchen STEP ONE STEP TWO STEP THREE

PANELIZED HOME INSTALLATION GUIDELINE

The WANZ Guide to Window Installation

BLADE S-MAX Cabinet for Blade Server

Edition Perfect combination ratiopacpro Electronic P Edition kaging www clear order..biz information in the catalogue

Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details

TABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"

THIRD PARTY INSPECTION GUIDELINES FOR OWNERS AND GENERAL CONTRACTORS/CONSTRUCTION MANAGERS DS150

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

Installation Instructions and Ordering Information


Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.

CI SfB. (4-) Nn2. Onduline. Mini Profile. Onduline Garden Roof Range. Onduline Building Products Ltd

Residential Roofing Guide

STANDING SEAM SHEET METAL ROOFING

Plans will call for one of two soffit/fascia details:

TECHNISCHE FICHE - TECHNISCHE FICHE - Chat Board: Classic

Light Architecture. Colors Sweden. Light

AMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

12.1 Schlüter -KERDI-BOARD

Colorcoat Urban The choice you ll be glad you made. CI/SIB (4-) Nh2 March 2012

CDW Systems Ltd Contemporary Doors & Windows

KAHU RESIDENTIAL ROOFING RRKA DETAIL LIST

Premier & Deluxe 3-Season Room Sliding Glass Door

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

Metal Building Systems Installation and Flashings & Details Guide. Table of Contents

GENERAL SHIELDING REQUIREMENTS FOR DIAGNOSTIC X-RAY FACILITIES. Major Medical (Radio/Fluoro/CT/Cardiac/Chiropractic)

Clad Direct Glaze Window Installation Instructions

Sun Windows General Information Sun New Construction Window Installation Instructions

Hoesch Matrix System individuell. ThyssenKrupp Steel Europe Thinking the future of steel

Grilles & Diffusers Series LFP Incorporating

SECTION PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK

Roof Curbs, Extensions and Equipment Supports

HfHMD uses LP SmartSide siding and trim.

Leaky Homes Financial Assistance Package (FAP) Repair plan example

Rittal s Comprehensive Family Of... NETWORK RACK SOLUTIONS

How To Build A Gambrel Roof And A Gable End Roof

ACOUSTICS. Axiom Canopy Clouds Absorption Data Sabines (average 500, 1k, 2k, 4k Hz) ACOUSTICS TESTING DATA Sound Absorption in Sabines

glass & Glazing Products

City of San Diego, CWP Guidelines

FLASHCLAD VERTICAL WEATHERBOARD CAVITY SYSTEM. Product. Scope. Appraisal No. 829 [2013] Appraisal No. 829 (2013) Amended 05 February 2016

ROOF FLASHING SPRINGLOK FLASHING SYSTEM FEATURES & BENEFITS PRODUCT DESCRIPTION

DECKING INSTALLATION, CARE & MAINTENANCE INSTRUCTIONS MOISTURESHIELD.COM limited lifetime warranty

BOQ SPECIFICATIONS. The Blind system consist of a coated aluminium tube of 38 mm diameter with provision of fabric clamping.

Tunnels & Arches OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

Transcription:

Oct 2012 I-Line - Snap-On Feature DATA SHEET Snap-On features - Guaranteed truelines every time Bailey I-Line Snap-On is an architectural cladding feature offering creative possibilities for architects and envelope contractors. Inspired by the use of exposed steel beams, I-Line combines the inherent structural integrity and strength of traditional steel beams with the versatility and practicality of lightweight pre-finished aluminium. This is achieved by combining the robust precision of extrusions with the adaptability of a pressed sheet. The projecting flange feature is extruded to give a consistently true leading edge, available in a range of standard sizes. The snap-on design principle used for I-Line also includes architectural features such as bullnose, square, window frame and cill profiles. (See enclosed Snap-On Feature Range) The Vertical web component is pressed from sheet material allowing a completely variable dimension between flanges and offers a variety of fixing methods. Bailey s commitment is to provide a first class service by supplying products of the highest quality, backed by willing and competent specialist advice. I-Line is part of Bailey s comprehensive range of Eaves Systems. These fascia and soffit products are highly versatile and each can be used by themselves or in combination with others. In its simplest form, I-Line is a feature channel used repetitively on elevations both horizontally and vertically, to define different cladding elements or demarcate floor levels. By extension, the extruded flange principle can be applied to any vertical aluminium face and is thus used in combination with cassette or v-joint fascia and soffit systems to create distinctive eaves profiles. Bailey is a long established company with an unrivalled combination of technical knowledge and design expertise that is the result of over 30 years experience of designing and supplying low maintenance eaves systems.

Using Bailey I-Line I-Line can be used as a single finishing element at the eaves or repeated to create stunning and distinctive motifs which reflect the creativity and originality required by an increasing proportion of corporate clients. I-Line enables the appearance of exposed structure but with the benefits of light weight and low maintenance. This makes it ideally suited to both new build and refurbishment projects. Installation and maintenance Bailey I-Line is normally installed by recommended contractors. The materials, finishes and construction used in Bailey I-Line are inherently low maintenance. As with any product, periodic checking and cleaning are required for which schedules appropriate to each project are available on completion. Colours and finishes Snap-On Features are available in a wide range of finishes including anodising, with architectural polyester powder coating being the standard option. Bailey provide a 30 year warranty on powder coating (subject to location) with a wide choice of RAL colours in various gloss levels and specials. Durability Bailey I-Line, like other Bailey Eaves products, is designed to combine low maintenance with an expected life of at least 30 years in urban and industrial environments and up to 50 years in rural locations. For marine environments the project requirement should be discussed with Bailey s technical department at an early stage to enable assessment of the most appropriate design, detailing and protective coating.

Bailey I-Line in use The potential combination and uses of Bailey I-Line are almost limitless. These pages provide some typical uses of I-Line in combination with other Eaves products. Specific information regarding Bailey cassette and Vee Joint soffit systems, Bailey Laser-Line carcassing, Bailey Monsoon gutter systems and Bailey Atlantic singly ply waterproofing can be found in the relevant datasheet for each product. Having selected the products to achieve your desired feature, Bailey s technical service is available to assist in preparation of the details and drafting of project specifications. Typical I-Line fascia soffit construction Typical vertical I-Line feature channel detail Typical I-Line combination of fascia/soffit

Snap-On feature range 50mm I-Line 55 I-Line 76 I-Line 102 50mm I-Line 220 Notes: Optional drip available. Features can be curved. For more information contact Bailey Technical Dept. 50mm 75mm 100mm

Bailey I-Line fixing detail 5mm 55/76/102/220mm 10mm /50mm Bailey variable pressed web plate fixed direct or, to avoid tolerance issues, use Bailey pre-galv carcassing system adapted to suit application & fixed to primary support (timber/ steel/concrete) variable pressed web plate flange support clip Snap-on flange extrusion 100/250/300mm Fixing@600c/s Fixing@600c/s to secure clip to fascia 5mm Guide to installation 1) Cover surfaces of pre-galv where it comes into contact with aluminium with isolating tape. 2) Install pre-galv tray with fixings at 600 c/s approx, fixing to penetrate primary support (timber/steel/concrete). 3) Install web plate to background substrate through 8mm hole at 600 c/s approximately using fixings as specified. 4) Install clip to cover 8mm holes using BFX27 hex Step head 1 fixings. 5) Install Snap-On flange by push-fit onto clip. Install web plate 6) Rivet flange to clip using 2 No BFX15 per length. Step 2 Screw the I-Line flange clips on to web plate concealling web plate fixing Step 1 Step 2 Step 3 Step 4 Install web plate Screw the I-Line flange clips on to web plate concealling web plate fixing Push the Snap-On flanges on to the supports Wipe over and clear the site of packaging Step 3 Step 4 Push the Snap-On flanges on to the supports Wipe over and clear the site of packaging

Specification Bailey recommends that where fascia systems are being specified alone they be specified within NBS section H31. Where a combined fascia, soffit and rainwater system, is being specifies, NBS section R10 should be used. Bailey can provide technical assistance and is always willing to draft specifications for individual projects. COMBINED FASCIA//SOFFITT AND GUTTER*SYSTEM TO. Drawing reference(s).. Profile type Bailey (Snap-On feature type) aluminium fascia system Profile dimensions Flange projection.mm Web height mm Material Aluminium sheet to EN485/515/573. Galvinised steel sheet to EN10327:2004 DX51D+z275NA for supporting carcassing Panel thickness *Cassette panels to be minimum 2mm but increased in accordance with the recommendations of Bailey Eaves Systems *Vee-joint extruded soffit planks to be 1.9mm thick. Finish/colour (As standard only visible faces are polyester powder coated, some severe industrial or marine locations may require coating to reverse side of some components. Bailey technical department should be consulted in these situations. The following specification is for standard polyester powder finishes. If a metallic or special effect polyester powder is required this should be stated below.) Polyester powder coated to a colour and gloss level selected from the manufacturer s standard range. Polyester powder coating is to be electrostatically applied at the manufacturer s in house plant. Pretreatment of the aluminium to produce no environmentally harmful effluent and confirm with European standards. Test samples are to be retained and results submitted to the architect if requested. Tests to be applied as a minimum are: 1) 1000 hours salt spray test; 2) Impact test (0.908kg from 0.25m high); 3) Permeability test (2 hour pressure cooker); 4) Adhesion test (2mm cross hatch); 5) Flexibility test (20mm mandrel); 6) MIBK cure test. 7) Film thickness Accessories Factory fabricated fascia corners, stopends, transitional flashing, rear edge trims, mitre cover strips etc as required. Supports To be fitted to Bailey carcassing system at centres recommended by Bailey. Fixing All fixings to be completely concealed. System to be fixed using aluminium and stainless steel fixings as recommended and supplied by Bailey Eaves System. Special features The system is to fully allow for normal building tolerances to be overcome on site without the necessity to purpose manufacture components to site dimensions. All factory fabricated components to be fully finished and dressed prior to polyester powder coating. *Panels to be stiffened to provide flat and acceptable surface using Bailey concealed stiffening system. (Only applies to Cassette soffit system) *Method of jointing Cassette panel system: I-Line fascia system to be butt jointed with 2mm to 3mm expansion gap.soffit panels to be jointed with Bailey interlocking and stiffening end joint detail with concealed fixings. *Method of jointing Vee-joint system: I-Line fascia system to be butt jointed with 2mm to 3mm expansion gap. Soffit planks to be butt jointed joints to be staggered. *Ventilation (Only include this section if ventilation is required via the eaves system.) Ventilation to be provided as an integral part of the eaves system. Vents to be in a concealed location and to require no separate mesh. Ventilation to give the equivalent of a 10mm/*25mm continuous air gap Packaging All components to be fully wrapped and protected. Bundles to be no larger than can be handled by one person to ensure transfer to point of installation in original packaging. In the case of large or heavy items, these should be clearly marked with the appropriate warning and the approximate weight. Fascia and soffit components to be labelled in accordance with part numbers given on working drawings. Installation To be in accordance with manufacturer s instructions. Entire fascia, soffit and rainwater system together with all carcassing work to be supplied and installed by one sub-contractor who is to be selected from the Bailey list of recommended sub-contractors. * Delete as appropriate Specification for other products can be found in the relevant datasheet or in the specification section of the Bailey Technical Handbook or on the Bailey website www.baileyeaves.com. UK office Blatchford Close Horsham West Sussex RH13 5RF Tel +44 (0)1403 261844 Email sales@bailey-uk.com www.bailey-uk.com European office Tel +31 (0)88 100 3800 Email sales@bailey-eu.com www.bailey-eu.com