IS76 Beacon with Ferrite Antenna Installation Manual



Similar documents
16/32 Channel 1U Rack Mount CCTV Power Supply

Wireless Home Security Alarm System AM 500

HM-W536 Install Guide

PROXIMITY CARD READERS C-10, C-20, C60, C70

Safety Warnings and Guidelines

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

ACS-30-EU-EMDR-10-MOD

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Installation Instructions. ThermoCall TC4. Entry/Advanced

VOT-320. VOT-320V0xxL VOT-320V0xxH. Quick Installation Guide

Installation Instructions. Thermo Call TC3

Shunt lock function 3066

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

FIRERAY 2000 Installation Guide

INSTALLATION / OWNERS MANUAL MODEL WB-200. PN # D-01 l-0007

FSLIMRF

PRO 5000 CPE 1D Quick Installation Guide

HORNET Remote Control Systems

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Model SRMD Setra Remote Monitoring Display

DCP Fan Controller. Version 01/2009. The engineer s choice

Manual. Solar Fountain Mobile Phone Charger

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

Instruction Sheet ACS-101. General Description. Specifications. Amplified Broadband UHF Combiner-Splitter. Overall. Antenna Splitter.

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

instabus KNX / EIB System System E F G H

VARIO PROX CARD READER INSTALLATION MANUAL

LED - Indicator Panels

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

Neo-Neon. LED Vision Mesh Screen Operation Manual. LED Vision Mesh Screen. Neo-Neon International Ltd He Shan Decorative Lighting Company Limited

Copyrights 2010 Victron Energy B.V. All Rights Reserved

HCR3.2/.. Chipcard reader HOTEL SOLUTION

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Advantium 2 Plus Alarm

INSTALLATION INSTRUCTIONS

ELITE-L Series. ELITE - Low Voltage / Dry contact Remote Control System

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Residential Gateway (RG) Battery Backup

Wireless Alarm System. Window/Door Sensor. User s Manual. Choice ALERT. Control all Sensors & accessories from one location

ST Series POWER SUPPLIES USER INSTRUCTIONS

Roadstar Installation Instruction Manual

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

MGL Avionics CAN bus interface for Trig Avionics TT21/TT22 transponders

ABB Stotz-Kontakt GmbH ABB safe&smart Project planning of security systems

TruPower-Portable-500W. Solar Starter kit

Shunt lock function 3066 Operator Instructions

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

GSM HOME SECURITY SYSTEM

User s Manual Before using the inverter, you need to read and save the safety instructions.

Antenna Splitter ASA 1. Instruction manual

BREEAM CRITERIA WATER LEAK DETECTION SYSTEM Type WG2 - CONTROL PANEL CONNECTIONS

Users manual. TCW181B-CM_R1 Page 1

FN2001-A1 Network module (SAFEDLINK) Mounting Installation

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

Product and Application Description

IN-OUT Thermometer with Cable Free Sensor and Clock

Hear The Future...Now! SIEM-2T/SIEM-2R

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST

SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

AARC-EVAC Portable Hand Held or Fixed Transmitter with SOS assist - ATX43E25 SAFETY ALERT SYSTEMS

Multi-Protocol decoder with Load regulation

CB Svendsen A/S PS / rev. 1.5

NC-12 Modbus Application

Temperature & Humidity SMS Alert Controller

ADM1TE 5/30A DIN rail single phase two wire energy meter

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

SP1790JK 900MHz Wireless Indoor/Outdoor Speakers. User Manual INTRODUCTION FEATURES IMPORTANT SAFETY INFORMATION

AXIS 291 1U Video Server Rack Installation Guide

TS93 EMR T/PT/TDE. Surface applied door closer

D287/D288/D292/D293A/D293E

Duct Humidity Transmitter

FTW 175 VERIZON Wireless Monitoring System Reference Manual Part Number VERIZON

Input module, input/output module

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

Model 201 Wiegand Touchpad Reader Installation Guide

Owner s Manual AWM910 JENSEN AWM910 COMPACT DISC PLAYER RADIO CD COMPACT MUSIC SYSTEM MUTE AUX BAND AUX IN PUSH PUSH PWR VOL ALARM T/F AUD SPK A SPK B

USER MANUAL V5.0 ST100

, User s Manual

Digital Active Indoor Antenna SRT ANT 10 ECO

e-ask electronic Access Security Keyless-entry

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

MIC-WKT and MIC-WKT-IR

INSTALLATION MANUAL XM3 Reader

AXIS T81B22 DC 30W Midspan

Specifications for EM VDC 4 In/4 Out and EM VDC 4 In/4 Relay Out

Users Manual FA106 / FA306 version 1.0. Field Analyzer. FA106 and FA306. Users Manual

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Telefon (+45) Telefax (+45) Installation and operating manual

Process Alarm Solutions

HFE1600 Series 1600W 1U Hot Swap Front End Power Supplies

How To Use A Power Supply On A Powerline 2.2 (Ai)

Setup guide. point to point wall plate extenders

Dell P Series Monitor VESA Mounting Bracket Installation Instructions

Alarm Security Kit - NVR

Transcription:

IS76 Beacon with Ferrite Antenna Installation Manual Edition: July 2009 Document N : 953-26a Page 1 of 9

Document No 953.26a IS76 Beacon with Ferrite Antenna: Installation Manual Edition: July 2009 Editor: TeleAlarm SA All rights reserved. TeleAlarm SA reserves the right to make changes to the information contained in this document at any time without prior notice. Great care has been given to the contents of this document; however TeleAlarm SA cannot be held liable for the consequences of any errors or omissions contained herein or for consequential or incidental damages incurred as a result of acting on information contained in the document. TeleAlarm SA Bosch Group Administration, R&D and Aftersale Rue du Pont 23 CH-2300 la Chaux-de-Fonds Switzerland Phone 41 (0)32 911 11 11 Fax 41 (0)32 911 11 00 www.telealarm.com Bosch Sicherheitssysteme GmbH Haus-ServiceRuf Ingersheimer Straße 16 D-70499 Stuttgart Germany Phone 0711 3653 1000 Fax 0711 811 5125 294 Haus-Service.Ruf@de.bosch.com www.bosch-sicherheitsprodukte.de Bosch Security Systems Ltd Broadwater Park North Orbital Road Denham UB9 5HN United Kingdom Phone 01895-878088 Fax 01895-878089 uk.securitysystems@bosch.com www.boschsecurity.co.uk Bosch Security Systems France Atlantic 361 361, avenue du Général de Gaulle F-92147 Clamart France Phone 33 (0)825 12 8000 (0,15 TTC/Min) Fax 33 (0)820 900 960 (0,12 TTC/Min) fr.securitysystems@bosch.com www.boschsecurity.fr Bosch Security Systems nv/sa Torkonjestraat 21F B-8510 Marke Belgium Phone 32 (0)56 20 02 40 Fax 32 (0)56 20 26 75 be.securitysystems@bosch.com www.boschsecurity.be Bosch Security Systems BV Postbus 80002 NL-5600 JB Eindhoven Netherlands Phone 31 40 25 77 200 Fax 31 40 25 77 202 nl.securitysystems@bosch.com www.boschsecurity.nl Bosch Security Systems AB Vestagatan 2 SE-416 64 Göteborg Sweden Phone 46 (0)31 722 5300 Fax 46 (0)31 722 5340 se.securitysystems@bosch.com www.boschsecurity.se Edition: July 2009 Document N : 953-26a Page 2 of 9

Content Locator Function...4 IS76 Beacon with Ferrite Antenna...4 IS76 Ferrite Antenna...4 IS76 Ferrite Beacon Controller...5 System Supervision...5 Features of the IS76 Beacon System...5 IS76 Ferrite Antenna...6 IS76 Beacon Controller...6 Connection Compartment...7 Enable Locator Function in NurseCall System...7 Configuration and Wiring...8 Ferrite Beacon Antenna...9 Ferrite Beacon Controller...9 Edition: July 2009 Document N : 953-26a Page 3 of 9

Locator Function The NurseCall system can be set to handle a Locator function. For this purpose, beacon modules and antennas of type IS75 or IS76 need to be installed on doors or corridors in the building you want to supervise. When passing one of these modules the Wristband Transmitters of type S37L or the Pendant Transmitters of type S35L refresh the position information that is stored into them. When triggering an Alarm, the transmitters S37L and S35L do not only transmit the identification (who sent the alarm), but also the position of the last passed module (where has the alarm been triggered). At the arrival of a call, the information of the actual position is indicated additionally on the NurseCall units. This information can be made visible by pressing the yellow button on the NurseCall Main- or Relay Unit. Locator information block: HELP POS: 077 A03 255 positions (POS: 000-254) can be differentiated. When passing beacon modules with position numbers 231-254 the transmitters S37L and S35L can send a call for help automatically without manual activation (wandering). Fixed transmitters that do not handle a Locator function (N46) are always indicated with the position 000. IS76 Beacon with Ferrite Antenna The IS76 Beacon system consists of two elements: The IS76 Ferrite Antenna The IS76 Ferrite Beacon Controller IS76 Ferrite Antenna The IS76 Ferrite antenna has to be mounted on the place that has to be identified with a location beacon code. The antenna is well suited to be mounted in a vertical position on (or next to) a door frame. In some circumstances it may also be mounted horizontally. The IS76 Ferrite Antenna can be placed outdoors as well as indoors. Edition: July 2009 Document N : 953-26a Page 4 of 9

IS76 Ferrite Beacon Controller The IS76 Ferrite Beacon Controller is necessary to drive the IS76 Ferrite Antenna. It connects to the mains power via an external power supply. Up to two IS76 Ferrite Antennas may be connected to the IS76 Beacon Controller, depending on the size of the passage that has to be covered with the beacon. The beacon location code is set-up on the IS76 Ferrite Beacon Controller. Contrary to the ferrite antenna, the IS76 Ferrite Beacon Controller has to be mounted indoors, in a well ventilated cool place. Supervision Signal lamp (LED): Connection compartment Figure 1 System Supervision The operation of the IS76 Beacon system is supervised. An eventual operation failure (broken wire or overload) is indicated by the front panel LED and by the opening of a "normally closed" relay contact that is accessible from the terminal block. The supervision output may be connected to an RAC-type alarm transmitter which would transmit the beacon operation failure to the NurseCall System. Features of the IS76 Beacon System Ferrite antenna offers a better defined capture range that is less dependent on the surrounding building material The antenna may be installed in or outdoors Up to 230 user selectable position (location) codes (001 to 230) Up to 24 user selectable "Wandering" codes (231 to 254) Supervision of the beacon functionality Edition: July 2009 Document N : 953-26a Page 5 of 9

IS76 Ferrite Antenna The Antenna is best fitted to be mounted vertically on a door's frame. In any case, the middle of the antenna should be at a height of 1 meter from the floor. The antenna has to be fixed by two screws, according to the figure below. 30mm /- 1mm 540mm /- 1mm 2 X D 5.5mm 600mm 0/-10mm Figure 2 Remove the cover caps at both ends of the antenna by sliding them against the outside Secure the antenna against the wall with both screws Replace the cover caps by sliding them over the housing Note: Even if the functionality of the Ferrite Beacon System is not affected by the presence of metallic items, it is not recommended to fix the antenna directly against such items. In order to avoid overheating of the IS76 Beacon Controller, install the antenna at least 1.5 cm away from metallic frames or surfaces. IS76 Beacon Controller The IS76 Beacon Controller can be fixed with two to five screws on the wall. Two holes at 60 mm interval are provided for direct mounting on connection boxes. The three upper holes are used for positioning the device and cannot be reached from the Connection Compartment. Two of the lower holes can be reached from outside and thus used for fixing the device. Edition: July 2009 Document N : 953-26a Page 6 of 9

13.1 80 53.8 3.7 16 Ø7.5 6.6 27 131 59.9 18.1 3.7 26 2 Figure 3 Important Note: In order to ensure proper cooling of the Beacon Controller, the unit needs to be installed vertically in a well ventilated place (avoid to mount it in sealed boxes). Connection Compartment All of the wiring and configuration functions such as: Connection of the IS76 Ferrite Antenna(s) Connection of the wired supervision output Setting of the Location identification code Can be carried out in the connection compartment. It is reached by taking off the lower part of the housing (see). This can be done even if the device is fixed on the wall. The connection cables can be channelled towards the outside through the hole next to the terminal blocks or downwards by breaking off part of the rear housing. Connection of the power supply can be done without taking off the lower part of the housing. Enable Locator Function in NurseCall System In order to be operational, the Locator function has to be enabled in the NurseCall Main Unit (refer to section "Selection Locate Function YES or No" in the NurseCall User Manual) Edition: July 2009 Document N : 953-26a Page 7 of 9

Configuration and Wiring *Antenna B is optional It is used to extend the capture range on large (double) doors B* A Supervision Signal Lamp: Green: ok Red: operation failure Position number: 128 64 32 16 8 4 2 1 ON Example above: 1x128 1x64 1x32 1x16 1x8 0x4 0x2 = 0x1 248 Supervision of Beacon A: Supervision of Beacon B: Enabled Disabled Ferrite Beacon Antenna B* Ferrite Beacon Antenna A Blue* White* Blue* Power Supply 24 VDC White* Supervision O utput *Polarity of the antenna and the wiring has to be respected when two antennas are used for the same beacon location RAC (optional) Edition: July 2009 Document N : 953-26a Page 8 of 9

Ferrite Beacon Antenna Housing Plastic case ASA for wall mounting L x H x P 600 x 30 x 30 mm Weight about 700 g Operation Range 1 Connecting cable 2 m "twisted pair" (may be extended up to 10 m) typ. 2.6 m typ. 3.6 m Antenna 1 When used in conjunction with S37L Wristband Transmitters of REV B and higher. Ferrite Beacon Controller Housing Plastic case ASA For wall mounting (L x H x P) Weight AC Power supply (included) DC Power supply Frequency Supervision Output Relay Max. Switching power Max. Switching voltage Max. switching current 133 x 82 x 26 mm about 200 g 100 240 VAC 12-24 VDC / max. 400 ma (1 antenna) Max. 800 ma (2 antennas) 68 khz 125 VA / 60 W 48 V DC 2 A Technical data is subject to changes. Edition: July 2009 Document N : 953-26a Page 9 of 9