USER MANUAL Z-3A0. Via Germania, 34 35127 Z.I. CAMIN PADOVA ITALY. Via Svizzera, 17 35127 Z.I. CAMIN PADOVA ITALY

Similar documents
ZC-24DO CANopen I/O Module: 24 Digital Outputs

Product EASY-USB. Description. USB - UART TTL converter. Seneca s.r.l. support@seneca.it sales@seneca.it. Series of product. Pag.

Modular I/O System Analog and Digital Interface Modules

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

RPDO 1 TPDO 1 TPDO 5 TPDO 6 TPDO 7 TPDO 8

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Contents. Document information

PCS0100en Persy Control Services B.V. Netherlands

Disturbance Recoder SPCR 8C27. Product Guide

Nemo 96HD/HD+ MODBUS

Rack mounted telephone- and leased line modem for industrial applications

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

PLC Master / Slave Example

Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide

Quick Connect. quick - simple - efficient.

A RF18 Remote control receiver MODULE

Telephone- and leased line modem for industrial applications TD-36

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Unidirectional Transmitter/ Receiver Units Introduction

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34)

Multi-Range Programmable DC Power Supplies 9115 Series

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

Durant PGM. For Sales and Support, Contact Walker EMD Toll-free: (800) Tel: (203) Fax: (203)

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

Duct Humidity Transmitter

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

TPM Product Type 107-D162-NNT 48-channel digital input and 16-channel digital output module with pluggable terminal

3½ DIGIT VOLTMETER MODULE LED- / LCD- SERIES

NC-12 Modbus Application

Software User Guide UG-461

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

MLC TM Maximum Productivity and Versatility for Control without Compromise!

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

User Manual Revision English

GPS NTP TIME SERVER Rack Version V2.2x

IO-DIM6 6-Channel, Digital to Analogue Converters

Technical Support Bulletin Nr.18 Modbus Tips

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

Application/Connection Examples

GPS NTP TIME SERVER Rack Version V2

EXTERNAL DIMENSIONS AND PARTS

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

DCREG INTERFACE VIA DEVICENET

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

TX OPEN RS232/485 module

Modbus TCP / DALI converter

Multi-Range Programmable DC Power Supplies 9115 Series

Analog signal converters CC-E I/I Current / current isolators

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

Interface Protocol v1.2

smart-house Controller Central Unit Module Type SH2WEB24

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

User Manual. AS-Interface Programmer

Installation manual. Generator Paralleling Controller GPC multi-line C

ABB Drives. User s Manual HTL Encoder Interface FEN-31

MANUAL PC1000R

Installation and User Guide

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement

User Manual Revision English

4511 MODBUS RTU. Configuration Manual. HART transparent driver. No. 9107MCM100(1328)

Install the DeviceNet Module using the following procedure:

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V]

DMX2PWM 9 Channel Dimmer Setup Manual

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

FM75 Low-Voltage Two-Wire Digital Temperature Sensor with Thermal Alarm

IO Expansion Module User & Installation Manual

User Manual Revision English

Fingerprint Based Biometric Attendance System

Bluetooth UART/RS232 Module

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

OPT SERIAL TO FIBER OPTIC CONVERTER

Digital and Analog I/O

MEMOBUS/Modbus Communications

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

CAM-VGA100 User Manual

Series OMEGA WATTS POWER SUPPLY AC/DC SINGLE OR MULTIPLE OUTPUT. Flexible modular design. Programmable outputs** Power factor correction***

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference :

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

User Manual Revision English

User Manual Revision English

PLUTO Safety-PLC. Manual Absolute Encoders

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

1 Application Description Objective Goals... 3

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

SERIAL INTERFACE. Series SSW-03 and 04

Dupline Field- and Installationbus Dupline Profibus-DP Gateway Type G

3500/62 Process Variable Monitor

Allen-Bradley/Rockwell

Application Note. Positioning with Dimetix distance sensor and SEW inverter FLS-C

Short information Parameters are programmed via front-side membrane keypad

Transcription:

USER MANUAL Z-3A SENECA s.r.l. Via Germania, 34 35127 Z.I. CAMIN PADOVA ITALY Via Svizzera, 17 35127 Z.I. CAMIN PADOVA ITALY Tel. +39.49.875355 875359 Fax. +39.49.876287 Web site: www.seneca.it Technical assistance: supporto@seneca.it (IT), support@seneca.it (Other) Commercial reference: commerciale@seneca.it (IT), sales@seneca.it (Other) This document is property of SENECA srl. Duplication and reproduction of its are forbidden (though partial), if not authorized. Contents of present documentation refers to products and technologies described in it. Though we strive for reach perfection continually, all technical data contained in this document may be modified or added due to technical and commercial needs; it s impossible eliminate mismatches and discordances completely. Contents of present documentation is anyhow subjected to periodical revision. If you have any questions don t hesitate to contact our structure or to write us to e-mail addresses as above mentioned. MI26 Page 1

Seneca Z-PC Line module: Z-3AO The Z-3AO module supplies 3 single-ended analog signals (voltage or current type). General characteristics It is possible to choose if each output is voltage or current type It is possible to change the electrical start/end scale between ± 1 V, -2 ma It s possible to manage the electrical values (for each output) if the interval time of RS485-bus communication failure is greater than a configurable time (see Timeout register) Output protection against the overvoltage surge transients and short-circuits Configuration of the module (node) address, baud-rate and output-type (voltage or current) by Dip-Switches It is possible to add/remove the module to/from RS485-bus without disconnecting the communication or power supply It is possible to switch automatically RS485 to RS232 or vice versa Features OUTPUT Number 3 Resolution 12 bit. If output is voltage-type, resolution=5mv; if output is current-type, resolution=5µa Response time < 5 ms (step response, 1%-9%) Accuracy Initial:.1% of Electrical End Scale (E.E.S.) Linearity:.5% of E.E.S. Calibration:.2% of E.E.S. Thermal stability:.1%/ C EMI: < 1% Protection Protection against the overvoltage surge transients by transient suppressor (4W/ms); protection against the output short-circuits by internal series PTC Voltage-type OUT Bipolar with E.S.S./E.E.S.(Electrical Start/End Scale) configurable between: ± 1Vdc. Output impedance: > 6 Current-type OUT Unipolar with E.S.S./E.E.S.(Electrical Start/End Scale) configurable between: -2mA. Output impedance: < 6 Internal supply Vaux The #4 and #7 screw terminals: power 13V to max18ma CONNECTIONS RS485 interface IDC1 connector for DIN 46277 rail (back-side panel) or (alternative) the screw terminals: 4(GND), 5(B), 6(A) RS232 interface Jack stereo 3.5mm connector:plugs into COMport(front-side panel) 15 Vac ISOLATIONS Between: power supply, ModBUS RS485, analog output 2

POWER SUPPLY Supply voltage Power consumption 1 4 Vdc or 19 28 Vac ( 5Hz - 6Hz) Min:.5W; Max: 3.2W The power supply transformer necessary to supply the module must comply with EN6742 (Isolated transformers and safety transformers requirements). To protect the power supply, it is recommended to install a fuse. Output connections The 3 analog outputs (voltage or current type) are avaliable at the screw terminals 7, 8, 9 and their refer to the equipotential screw terminals 1, 11, 12 (GND) (connected internally). 3

Dip-switches table In the following tables: box without circle means Dip-Switch= (OFF state); box with circle means Dip-Switch=1 (ON state). BAUD-RATE (Dip-Switches: DIP-SWITCH STATUS) 1 2 Meaning Baud-rate=96 Baud Baud-rate=192 Baud Baud-rate=384 Baud Baud-rate=576 Baud ADDRESS (Dip-Switches: DIP-SWITCH STATUS) 3 4 5 6 7 8 Meaning Address and Baud-Rate are acquired from memory(eeprom) Address=1 Address=2 Address=3 Address=4 X X X X X X Address=63 RS485 TERMINATOR (Dip-Switch: TERM) 1 Meaning RS485 terminator disabled RS485 terminator enabled OUTPUT TYPE (Dip-Switches: ANALOG OUTPUT) 1 2 3 Meaning 1 2 3 Meaning 1 2 3 Meaning OUT1=voltage OUT2=voltage OUT3=voltage OUT1=current OUT2=current OUT3=current RS485 Register table Name Range Interpretation of R/W Default Address register MachineID / MSB, LSB R 41 Id_Code (Module ID) xf (=15 Bit [15:8] decimal) Ext_Rev (Module version) Bit [7:] FWREV / Word R 411 Firmware Code Errors / Bit R 48 These bits aren t used / Bit [15:5] Memory loss of data (in EEPROM): =there isn t;1=there is / Bit 4 4

This bit isn t used / Bit 3 Fault error (there is if the interval time of RS485-bus / Bit 2 communication failure is greater than Timeout/1 [sec]): =there isn t; 1=there is These bits aren t used / Bit [1:] Eprflag / Bit R/W 44 These bits aren t used / Bit[15:13] =old modality for Z-3AO module; 1=new modality for Z- Bit 12 3AO module These bits aren t used Bit [11:8] Module behavior if there is a fault error: =no operation; Bit 7 1=the module overwrites the content of the register: 469 in 45, 47 in 46, 471 in 47). See register 43 These bits aren t used / Bit [6:5] Parity for RS485: =even parity; 1=odd parity Bit 4 Parity for RS485: =deactivated; 1=activated Bit 3 Delay for RS485 (delay of communication response: Bit 2 pauses between the end of Rx message and the start of Tx message): =there isn t; 1=there is These bits aren t used / Bit [1:] Baudrate Address: from x1=1 to MSB, LSB R/W 42 Address xff=255 Baud-rate for RS485 (baud-rate of module/node if 384 Bit [15:8] parameters are configurated by memory modality): =48; 1=96; 2=192; 3=384; 4=576; 5=1152; 6=12; 7=24 Address for RS485 (address of module if parameters are 1 Bit [7:] configurated by memory modality) Command xbab, xcac, xc1a Word R/W 49 Save configuration in memory (EEPROM), if reg.49=xbab The module writes the Dip-Switches-state in reg.41, if reg.49=xcac Module reset, if reg.49=xc1a Command aux Bit R 41 These bits aren t used / Bit [15:11] Dip-Switch "Analog Output 3" state. It corresponds to the / Bit 1 selected output3-type. Bit41.1= corresponds to the current-type output, bit41.1=1 corresponds to the voltage-type output (if reg.49=xcac) Dip-Switch "Analog Output 2" state. It corresponds to the / Bit 9 selected output2-type. Bit41.9= corresponds to the current-type output, bit41.9=1 corresponds to the voltage-type output (if reg.49=xcac) Dip-Switch "Analog Output 1" state. It corresponds to the / Bit 8 selected output1-type. Bit41.8= corresponds to the current-type output, bit41.8=1 corresponds to the voltage-type output (if reg.49=xcac) Dip-Switches "DipSwitchStatus [1:2]" state. They / Bit [7:6] correspond to the module baud-rate (if reg.49=xcac) Dip-Switches "DipSwitchStatus [3:8]" state. They / Bit [5:] correspond to the module address (if reg.49=xcac) Timeout Between: 1(=1msec); Word R/W 43 25(=25msec) Timeout [sec/1] (if bit44.7=1: it is interval time of 1 RS485-bus communication failure, after which the (=1sec) bit48.2 switches to 1 and the module overwrites the 5

content of the register: 469 in 45, 47 in 46, 471 in 47) OUTPUT 1 OUT1 Between:-1; 1 (if Word R/W 45 OUT1-mV OUT1-mV 1 OUT1-µA OUT1-µA 1 voltage), ;1 (if current) Normalized value of output1. The corresponding electric value is the voltage or current-type value available at the screw terminals 7-GND (see figure 1 and 2) Between: -11[mV]; +11[mV] Electrical value of output 1 [mv] corresponding to the normalized value OUT1= (if output 1 is voltage-type) (see figure 1 and 2) 6 OUT1 Fault Word R/W 412 Between: -11[mV]; +11[mV] Electrical value of output 1 [mv] corresponding to the normalized value OUT1=1 (if output 1 is voltagetype). This value coincides with the Electrical End Scale (E.E.S.) of the output1 (see figure 1 and 2) [mv] Word R/W 413 1 [mv] Between: [µa]; +22[µA] Word R/W 418 Electrical value 1 [µa] corresponding to the normalized 4 [µa] value OUT1= (if output 1 is current-type) (see figure 1 and 2) Between: [µa]; +22[µA] Word R/W 419 Electrical value 1 [µa] corresponding to the normalized value OUT1=1 (if output 1 is current-type). This value coincides with the Electrical End Scale (E.E.S.) of the output1 (see figure 1 and 2) OUT1 Fault Between:-1; 1 (if voltage), ;1 (if current) 2 [µa] Word R/W 469 Normalized fault value of output 1. The corresponding electric value is the voltage or current-type value available at the screw terminals 7-GND (see figure 1 and 2). This register is overwritten in the reg.45: if the module is connected to the RS485 bus communication (to initialize it) or if: bit 48.2=1 and bit44.7=1 OUTPUT 2 OUT2 Between:-1; 1 (if Word R/W 46 voltage), ;1 (if current) Normalized value of output2. The corresponding electric value is the voltage or current-type value available at the OUT1 Fault screw terminals 8-GND (see figure 1 and 2) OUT2-mV OUT2-mV 1 OUT2-µA Between: -11[mV]; +11[mV] Electrical value of the output 2 [mv] corresponding to the normalized value OUT2= (if output 2 is voltage-type) (see figure 1 and 2) Word R/W 414 Between: -11[mV]; +11[mV] Electrical value of output 2 [mv] corresponding to the normalized value OUT2=1 (if output 2 is voltagetype). This value coincides with the Electrical End Scale (E.E.S.) of the output1 (see figure 1 and 2) [mv] Word R/W 415 1 [mv] Between: [µa]; +22[µA] Word R/W 42 Electrical value 2 [µa] corresponding to the normalized value OUT2= (if output 2 is current-type) (see figure 1 and 2) 4 [µa]

OUT2-µA 1 OUT2 Fault Between: [µa]; +22[µA] Word R/W 421 Electrical value 2 [µa] corresponding to the normalized value OUT2=1 (if output 2 is current-type). This value coincides with the Electrical End Scale (E.E.S.) of the output2 (see figure 1 and 2) Between: -1; 1 (if voltage), ;1 (if current) Normalized fault value of output 2. The corresponding electric value is the voltage or current-type value available at the screw terminals 8-GND (see figure 1 and 2). This register is overwritten in the reg.46: if the module is connected to the RS485 bus communication (to initialize it) or if: bit 48.2=1 and bit44.7=1 OUTPUT3 OUT3 Between:-1; 1 (if voltage), ;1 (if current) OUT3-mV OUT3-mV 1 OUT3-µA OUT3-µA 1 2 [µa] Word R/W 47 Word R/W 47 Normalized value of output3. The corresponding electric value is the voltage or current-type value available at the screw terminals 9-GND (see figure 1 and 2) Between: -11[mV]; +11[mV] Electrical value of the output 3 [mv] corresponding to the normalized value OUT3= (if output 3 is voltage-type) (see figure 1 and 2) OUT3 Fault Word R/W 416 Between: -11[mV]; +11[mV] Electrical value of output 3 [mv] corresponding to the normalized value OUT1=1 (if output 3 is voltagetype). This value coincides with the Electrical End Scale (E.E.S.) of the output3 (see figure 1 and 2) [mv] Word R/W 417 1 [mv] Between: [µa]; +22[µA] Word R/W 422 Electrical value 3 [µa] corresponding to the normalized 4 [µa] value OUT3= (if output 3 is current-type) (see figure 1 and 2) Between: [µa]; +22[µA] Word R/W 423 Electrical value 3 [µa] corresponding to the normalized value OUT3=1 (if output 3 is current-type). This value coincides with the Electrical End Scale (E.E.S.) of the output3 (see figure 1 and 2) OUT3 Fault Between:-1; 1 (if voltage), ;1 (if current) 2 [µa] Word R/W 471 Normalized fault value of output 3. The corresponding electric value is the voltage or current-type value available at the screw terminals 9-GND (see figure 1 and 2). This register is overwritten in the reg.47: if the module is connected to the RS485 bus communication (to initialize it) or if: bit 48.2=1 and bit44.7=1 With reference to the output1 (and, in the same way, to the output2 and output3), the electrical value OUT1-mV ( OUT1-µA ) is NOT the Electrical Start Scale (E.S.S.), if output is voltage (current)-type. The Electrical Start Scale is the electrical value corresponding to the normalized value=-1 (unchangeable). 7

In the following lines is described the register configuration of the output1 to obtain the desired electrical value; the register configuration of the output 2 and 3 is similar. To configure the analog output 1 in voltage (current)-type, execute the following operations: 1) configure the register OUT1-mV ( OUT1-µA ) corresponding to the normalized value= and OUT1-mV 1 ( OUT1-µA 1 ) corresponding to the normalized value=1 (figure 1); 2) configure the register OUT1: it is the normalized value corresponding to the desired electrical value available at the screw terminals (mv or µa) (figure 1); Fig.1 Description of output configuration (step 1 and step 2) The content of the register OUT1-mV 1 ( OUT1-µA 1 ) coincides with the Electrical End Scale (E.E.S.); the Electrical Start Scale (E.S.S.) is the electrical value corresponding to the normalized value=-1, and it isn t a register. 3) it s possible to read the electrical value through the screw terminals (7-GND for output 1) corresponding to the normalized value=out1. If the output is current-type and if OUT1=[-1;], E.S.S.=µA. 8

Fig.2 - Description of output configuration (step 3) LEDs for signalling In the front-side panel there are 4 LEDs and their state refers to important operating conditions of the module. LED LED status Meaning PWR Constant light The module power is on ERR Blinking light The module has at least one of the errors described in RS485 Registers table Constant light Module failure or there is a fault error (bit48.2=1) RX Constant light Verify if the bus connection is corrected Blinking light The module received a data packet TX Blinking light The module sent a data packet Easy-SETUP To configure the Seneca Z-PC Line modules, it is possible to use Easy-SETUP software, Free-downloadable from the www.seneca.it; the configuration can be performed by RS232 or RS485 bus communication. 9