Special Accessories. Sydrive Configurator software. 3G3IV-PCN126/326 Digital Operator Extension Cable



Similar documents
J1000. System configuration

Cat. No. I527-E2-02 USER S MANUAL SYSDRIVE 3G3MV. Multi-function Compact Inverter

VS-606V7 Series Instruction Manual COMPACT GENERAL-PURPOSE INVERTER (VOLTAGE VECTOR CONTROL)

Frequency Converter Fv

Manual No. YEG-TOE-S OY. VARISPEED F7 Vector Control Frequency Inverter USER S MANUAL

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

VARISPEED V7 IP65 Compact Sensorless Vector Inverter USER S MANUAL

YASKAWA AC Drive Compact V/f Control Drive J1000

VS mini J7. USER S Manual. Compact General Purpose Inverter. VS mini J7

A1000 Cheat Sheet (Open Loop Vector)

OPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3

Manual No. TOE-S606-12F-OY. VS mini J7. Compact General Purpose Inverter USER S MANUAL

3G3JX AC DRIVES Compact and complete

Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations

Multifunction Digital Timer

EFC Frequency converters

Installation manual. Generator Paralleling Controller GPC multi-line C

Specifying a Variable Frequency Drive s

Varispeed V7 INSTRUCTION MANUAL

VCM Installation and Operations Manual. Table of Contents

AC ADJUSTABLE SPEED DRIVES MICRO SERIES INVERTERS

Easy to connect - Easy to configure Easy to install

Number 1 in efficiency

COMPACT INVERTER FOR GENERAL-USE

TABLE OF CONTENTS. Fig. 1 EV Pictorial Wiring Diagram 5. Section 2 Inverter Option Modules 6

SJ200 Series Inverter Quick Reference Guide

MC Series Drives. Flexible, simple, rugged, robust! Phone: Fax: Web: info@actechdrives.

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

MEMOBUS/Modbus Communications

Smart DeviceNet Remote I/O Terminals

vacon x series rugged drives for the real world

WJ200 series Pursuing the Ideal Compact Inverter

Absolute Rotary Encoder E6CP

SAFETY INSTRUCTIONS WARNING

PSR The compact range Description

Liquid Leakage Sensor Amplifier

Phone: Fax: Web: info@clrwtr.com

How To Use The Vacon 0 Machinery

Three-phase Asymmetry and Phase-sequence Phase-loss Relay K8AB-PA

Electronic Control Devices The European Product Catalogue 2007

Thyristor-controlled power supplies and battery chargers

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

SAFETY INSTRUCTIONS. Always follow safety instructions to prevent accidents and potential hazards from occurring.

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

40.3. Control Relays and Timers

General-purpose Relay

VLT Series 3500 Adjustable Frequency Drive Instruction Manual

Frequency inverter Lenze. Global Drive vector kw. Created as a system

Brushless DC Motors Intro duction BLF BLU BLH Installation. Brushless DC Motors. DC Input. AC Input DC Input. BLH Series. Page. BLH Series B-52 B-51

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

SAFETY INSTRUCTIONS WARNING

DC Electronic Loads 8500 series

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

Duct Humidity Transmitter

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC

3753 en /b VE/B - VE/RG Va V riable speed drives

Voltage Regulator SPAU 341 C. Product Guide

SINUS M. USER MANUAL -Installation and Programming Instructions-

CQM1-SF200/CS1W-SF200

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Ordering Information. Latching Relay G2AK. Model Number Legend Magnetic Latching Version of G2A Ideal for Sequence Control

Series LC6D/LC6C. To power supply PLC. LC6C dedicated teaching box P.971. Options P.973

NX safety stand-alone

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.

2011 Industrial Catalog. DRIVES, PAC, PLCs. Industrial Catalog

Electronic Control Devices The European Product Catalogue 2007

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

RM4TG20 three-phase network control relay RM4-T - range V

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

MAJORSINE Power Inverter

Contents. Document information

TOSVERT VF-MB1. Functions for lift application

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

EET272 Worksheet Week 9

SAFETY INSTRUCTIONS. To prevent injury and property damage, follow these instructions during the installation and operation of the inverter.

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Speed Control Relays SX2

YASKAWA AC Drive-J1000

EXTERNAL DIMENSIONS AND PARTS

Bulletin 150 SMC Flex Smart Motor Controller Specifications

BITMAIN. APW PSU Series User Guide

TRAMS TROLLEY-BUSES SUBWAY

Electric Rotary Actuator - On/Off or programmable control actuator

Talon and Talon SR User Manual

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

SPEED CONTROL SYSTEM

How To Read A Pipe From A Sensor

32VFD Variable Frequency Drives for Centrifugal Chillers

Preset Counter signo 721

Quick Connect. quick - simple - efficient.

AS A Low Dropout Voltage Regulator Adjustable & Fixed Output, Fast Response

SAFETY INSTRUCTIONS. Always follow safety instructions to prevent accidents and potential hazards from occurring.

NX Series Inverters. HVAC Pocket Programming Guide

Analog Servo Drive 25A8

Digital Pressure Measuring Instrument MDR480

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Transcription:

3G3MV Sensorless vector in pocket size Sensorless vector controlled inverter Compact size Frequency setting signal 0..10 V / 4..20 ma 150% overload / 60 sec 100% torque at 0.5 Hz Pulse input Integrated PID controller Standard digital operator with copy function Fieldbus options: DeviceNet, PROFIBUS, CANopen Plug-in PLC option unit Easy Maintenance Energy saving function Standard RS485 communications - Modbus CE, UL, and cul marking Customised application software Ratings 200V Class single-phase 0.1 to 4 KW 200V Class three-phase 0.1 to 7.5 KW 400V Class three-phase 0.2 to 7.5 KW System Configuration Special Accessories 3G3IV-PCN329-E Inverter to PC cable Sydrive Configurator software DIN attachment 3G3IV-PZZ8122@ Second analog input cable 3G3MV-PCN-CN2 JVOP-144 Remote Digital Operator With potentiometer JVOP146 Remote Digital Operator Without potentiometer 3G3IV-PCN126/326 Digital Operator Extension Cable Line Filter Braking Accessories R S T 3G3MV-PFI@ Input Noise Filter LKEB@ Braking Resistor Unit CDBR@B Braking Unit ERF150WJ@ Braking Resistor Power Supply Communication Unit PLC Option Unit 205

Specifications Type Designation 3G3MV A4007 N Z 3G3MV Series Installation type A: Close wall mounting (IP 20) Voltage 2: Three-phase 200 V class B: Single-phase 200 V class 4: 400 V class Heatsink option Z: No heatsink - : With heatsink Front Cover options B: Blank cover N: No potentiometer - : With potentiometer Max. Applicable Motor Output 001: 0.1 kw ~ 075: 7.5 kw 200 V class Single-phase: 3G3MV- 1 AB001 AB002 AB004 AB007 AB015 AB022 AB040 Three-phase: 3G3MV- A2001 A2002 A2004 A2007 A2015 A2022 A2040 Maximum permissible motor output kw 2 0.12 0.25 0.55 1.1 1.5 2.2 4.0 Output characteristics Power Supply 1. Single-phase series inverter output is three-phase. Single-phase motor cannot be applied. 2. Based on a standard 4-pole motor for maximum applicable motor output. Select the inverter model within the allowable motor rated current 400 V class Inverter capacity kva 0.3 0.6 1.1 1.9 3.0 4.2 6.7 Rated output current A 0.8 1.6 3.0 5.0 8.0 11.0 17.5 Max. output voltage Proportional to input voltage: 0..240 V Max. Output frequency Rated input voltage and frequency Allowable Voltage Fluctuation Allowable Frequency Fluctuation 400 Hz Single-phase 200..240V 50/60 Hz 3-phase 200..230V 50/60 Hz -15%..+10% Three-phase: 3G3MV- A4002 A4004 A4007 A4015 A4022 A4030 A4040 A4055 A4075 Maximum permissible motor output kw 1 0.37 0.55 1.1 1.5 2.2 3.0 4.0 5.5 7.5 Output characteristics Power Supply Inverter capacity kva 0.9 1.4 2.6 3.7 4.2 5.5 7.0 11.0 14.0 Rated output current A 1.2 1.8 3.4 4.8 5.5 7.2 9.2 14.8 18.0 Max. output voltage Proportional to input voltage: 0..400 V Max. Output frequency Rated input voltage and frequency Allowable Voltage Fluctuation Allowable Frequency Fluctuation 1. Based on a standard 4-pole motor for maximum applicable motor output. Select the inverter model within the allowable motor rated current +5% 400 Hz 3.phase 380..460 VAC, 50/60 Hz -15%..+10% +5% 206

Commom Specifications Control Functionality Protection Ambient conditions Model Number 3G3MV- Control methods Output frequency range Frequency tolerance Resolution of frequency set value Resolution of output frequency Overload capability Frequency set value Braking torque (short term peak torque) Binary inputs Binary outputs Analogue output Analogue inputs Braking/acceleration times Display Motor Overload Protection Instantaneous Overcurrent Overload Overvoltage Undervoltage Momentary Power Loss Cooling Fin Overheat Stall Prevention Level Cooling Fan Fault Ground Fault Power Charge Indication Degree of protection Cooling Ambient temperature Ambient humidity Storage temperature Installation Installation height Vibrations Specifications Sine wave PWM (V/f control, sensorless vector control) 0.1..400 Hz Digital set value: ±0.01% (-10..+50 ºC) Analogue set value: ±0.5% (25 ±10 ºC) Digital set value: 0.01 Hz (<100 Hz), 0.1 Hz (>100 Hz) Analogue set value: 1/1000 of maximum frequency 0.01 Hz 150%/60 s 0..10 V (20 kω), 4..20 ma (250 Ω), 0..20 ma (250 Ω) Pulse train input, frequency setting value (selectable)l Up to 200 W 150% or more 550 W to 1.1 kw 100% or more 1.5 kw 50% or more >1.5 kw 20% or more Continuous braking torque approx. 20% without, 150% with external braking resistor 7 freely programmable inputs 1 relay output, 2 freely programmable open collector outputs 1 programmable analogue output (0..10 V)/pulse output 2 analogue inputs, 0..10 V, 4..20 ma, 0..20 ma 0.01..6000 s Optionally frequency, current or set value Error and status LED Electronic thermal overload relay Motor coasts to a stop at approx. 250% of inverter rated current Motor coasts to a stop after 1 minute at 150% of inverter rated output current Motor coasts to a stop if DC bus voltage exceed 410V (double for 400V class) Stops when DC bus voltage is approx. 200V or less (double for 400V class) (approx. 160V or less for single-phase series) Following items are selectable: Not provided (stop if power loss is 15ms or longer), continuous operation if power loss is approx. 0.5s or shorter, continuous operation Protected by electronic circuit Individual levels during accel/constant speed. Decel ON/OFF available. During decel enable/disable selectable. Detected by electronic circuit (fan lock detection) Protected by electronic circuit (operation level is approx. 250% of rated output current) RUN lamp stays ON or digital operator LED stays ON until the DC bus voltage becomes 50V or less. (Charge LED is provided for 400V) IP20 and NEMA1 Self cooling for 200V 0,1..0,4 KW (3 or single phase) and for 400V 0,2..0,75 KW Cooling fan for 200V 0,75 to 7.5 KW and for 400V 1.5 to 7.5 KW Open air mounting: -10 ºC..50 ºC Wall mounting: -10 ºC..40 ºC 95% (without condensation) -20 ºC..+60 ºC (short-term temperature during trasnportation) Indoor (no corrosive gas, dust, etc.) Max. 1000 m 10 to 20 Hz, 9.8 m/s 2 max; 20 to 50 Hz, 2m/s 2 max 207

Digital operator Data display Indicators (Setting/Monitor item indicators) FREQUENCY adjuster Operation keys Appearance e Name Function Data display Displays relevant data items, such as frequency reference, output frequency, and parameter set values. Frequency adjuster Sets the frequency reference within a range between 0 Hz and the maximum frequency. Frequency reference indicator Output frequency indicator Output current indicator Multi-function monitor indicator Forward/Reverse selection indicator Local/Remote selection indicator Parameter setting indicator Mode Key Increment Key The frequency reference can be monitored or set while this indicator is lit. The output frequency of the Inverter can be monitored while this indicator is lit. The output current of the Inverter can be monitored while this indicator is lit. The values set in U01 through U10 are monitored while this indicator is lit. The direction of rotation can be selected while this indicator is lit when operating the Inverter with the RUN Key. The operation of the Inverter through the Digital Operator or according to the set parameters is selectable while this indicator is lit. (See note 1.) The parameters in n001 through n179 can be set or monitored while this indicator is lit. (See note 2.) Switches the simplified-led (setting and monitor) item indicators in sequence. Parameter being set will be canceled if this key is pressed before entering the setting. Increases multi-function monitor numbers, parameter numbers, and parameter set values. Decrement Key Decreases multi-function monitor numbers, parameter numbers, and parameter set values. Enter Key RUN Key Enters multi-function monitor numbers, parameter numbers, and internal data values after they are set or changed. Starts the Inverter running when the 3G3MV is in operation with the Digital Operator. STOP/RESET Key Stops the Inverter unless parameter n007 is set to disable the STOP Key. Used to reset the Inverter when an error occurs. (See note 3.) Note: 1. The status of the local/remote selection indicator can be only monitored while the Inverter is in operation. Any RUN comand input is ignored while this indicator is lit. 2. While inverter is in operation, the parameters can be only monitored and only some parameters can be changed. Any RUN command is ignored while the parameter setting indicator is lit. 3. For safety reasons, the reset function cannot be used while an operation instruction (forward/reverse) is being input. Turn the operation instruction OFF before using this function. 208

Dimensions IP 20 type 0.1 to 4 KW 2 M4 4 M4 W 1 W H 2 H 1 H 8.5 (0.34) D D1 W 1 W H 2 H 1 H 8.5 (0.34) D D1 Voltage Class Three-phase 200V Singlephase 200V Three-phase 400V Max. Applicable Motor Output kw IP20 / NEMA1 type 5.5/7.5 KW Figure 1 Figure 2 Inverter Model 3G3MV-A Figure Dimensions in mm W H D W1 H1 H2 D1 0.12 2001 0.6 76 10 0.25 2002 0.6 1 68 56 5 0.55 2004 108 42 0.9 1.1 2007 128 128 118 62 1.1 1.5 2015 131 1.4 108 96 64 2.2 2022 2 140 5 1.5 4.0 2040 140 143 128 71 2.1 0.12 B001 76 0.6 10 0.25 B002 1 68 76 56 118 5 0.7 0.55 B004 131 42 1.0 1.1 B007 108 128 140 96 1.5 64 1.5 B015 156 96 1.5 2 118 5 2.2 B022 140 163 128 2.2 71 4.0 B040 170 180 158 2.9 0.37 4002 1.1 4007 108 140 92 96 Mass kg 16 1.0 0.55 4004 110 34 1.1 1.5 4015 2 128 118 5 64 1.5 156 2.2 4022 1.5 3.0 4030 2.1 140 143 128 71 4.0 4040 2.1 1.5 Cooling Method Self cooled Fan cooled Self cooled Fan cooled Self cooled Fan cooled Figure 3 Voltage Class Three-phase 200V Three-phase 400V Max. Applicable Motor Output kw Inverter Model 3G3MV-A# Figure Dimensions in mm (inches) W H D W1 H1 H2 D1 5.5 2055 4.6 180 260 170 164 244 8 65 7.5 2075 4.8 3 5.5 4055 4.8 180 260 170 164 244 8 65 7.5 4075 4.8 Mass kg Cooling Method Fan cooled 209

Installation Standard Connections DC REACTOR (OPTION) U X SHORT BAR THERMAL OVERLOAD BRAKING RESISTOR RELAY (OPTION) (OPTION) MCCB +2 +1 B1 B2 R R/L1 S S/L2 U/T1 T T/L3 NPN 24V V/T2 IM FORWARD RUN/STOP S1 PHC W/T3 REVERSE RUN/STOP EXTERNAL FAULT (NO CONTACT) S2 S3 PHC PHC GROUNDING MULTI- FUNCTION INPUT FAULT RESET MULTI-STEP SPEED REFERENCE 1 MULTI-STEP SPEED REFERENCE 2 JOG COMMAND S4 S5 S6 S7 PHC PHC PHC PHC MA MB MC FAULT MULTI-FUNCTION OUTPUT 250VAC 1A OR ESS 30VDC 1A OR LESS SC PNP P1 RUNNING FREQUENCY REFERENCE PULSE TRAIN INPUT 2kΩ P FREQUENCY SETTER P SHIELD CONNECTION TERMINAL SPEED REFERENCE RP PULSE TRAIN (33kHz MAX.) FREQUENCY SETTING FS POWER SUPPLY (+12V 20mA) SPEED FREQUENCY FR REFERENCE 0 TO +10V (20kΩ) OR FC 4 to 20mA (250Ω) 0V DIGITAL OPERATOR FREQUENCY SETTING POTENTIOMETER MIN MAX CN2 P2 PC VIN IIN GND SPEED AGREE MULTI-FUNCTION PHOTOCOUPLER OUTPUT +48VDC 50mA OR LESS HOUSING (TYPE : ZHR-3) 0 to 10V P 4 to 20mA 0V MULTI-FUNCTION ANALOG INPUT* MEMOBUS COMMUNICATION RS-485/422 max 19.2kBPS R+ R S+ TERMINAL (1/2W. 120Ω) RESISTANCE AM AC FREQUENCY METER ADJUSTING POTENTIOMETER P FM OUTPUT FEQUENCY ANALOG MONITOR OUTPUT 0 TO +10VDC (2mA) PULSE MONITOR OUTPUT (12VDC 20mA MAX. 30-70% DUTY) S * A housing is required when using the CN2 terminal on the back side of the digital operator. 1m analog input cable (code no. 3G3MV-PCN-CN2) is available for housing on request : shielded wire P : twisted pair shielded wire Shows the following two kinds of connections (factory setting) : Input signals (S1 to S7) are non-voltage contacts Sequence connection by NPN transistor (0V common) A +24V power supply is required for sequence connection by PNP transistor (+24V common). 210

Main Circuit Terminal Name Function (Signal Level) R/L1, S/L2, T/L3 AC Power Supply Input U/T1, V/T2, W/T3 Inverter Output For inverter output B1, B2 Braking Resistor Connection For braking resistor connection Main circuit power supply input (Use R/L1 and S/L2 for single-phase power supply inverter. Do not use T/L3 of the models less than 0.75kW for other usage, such as a junction terminal.) +2, +1 DC Reactor Connection Remove the short bar between +2 and +1 when connecting DC reactor (option) +1, DC Power Supply Input For power supply input (+1: positive electrode; : negative electrode)* Grounding For grounding (Grounding should be conforming to the local grounding code.) Control Circuit Type No. Signal Name Function Signal Level S1 Multi-function Input Selection 1 Factory setting: Runs when CLOSED, stops when OPEN. Digital input signals Analog input signals S2 Multi-function Input Selection 2 Factory setting: Runs when CLOSED, stops when OPEN. S3 Multi-function Input Selection 3 Factory setting: "Fault reset" S4 Multi-function Input Selection 4 Factory setting: "External fault (NO contact)" S5 Multi-function Input Selection 5 Factory setting: "Multi-step speed reference 1" S6 Multi-function Input Selection 6 Factory setting: "Multi-step speed reference 2" S7 Multi-function Input Selection 7 Factory setting: "JOG command" SC Multi-function Input Selection Common Common for control signal RP Speed Reference Pulse Train Input 33kHz max. FS Power Supply Terminal for Frequency Setting +12V (allowable current: 20mA max.) FR Speed Frequency Reference 0 to +10V DC (20kΩ) or 4 to 20mA (250Ω), 0 to 20 ma (250Ω) (resolution 1/1000) FC Frequency Reference Common 0V 1 (CN2) Multi-function analog voltage input Voltage input (between terminals 1 and 3): 0 to 10 V DC ( Input impedance: 20 kω) 2 (CN2) Multi-function analog current input Current input (between terminals 2 and 3): 4 to 20 ma (Input impedance: 250 Ω) 24VDC, 8mA photocoupler insulation 3 (CN2 Multi-function analog input common Digital output signals Analog output signals MA MB NO Contact Output NO Contact Output Factory setting: "Fault" MC Contact Output Common P1 Photocoupler Output 1 Factory setting: "Running" P2 Photocoupler Output 2 Factory setting: "At frequency" PC Photocoupler Output Common 0V Factory setting: "Output frequency" 0 to +10V output AM Analog Monitor Output (Pulse monitor output available by setting constants. Duty: 30 to 70%) AC Analog Monitor Common 0V Contact capacity 250V AC, 1A or less 30VDC, 1A or less Photocoupler output: +48VDC, 50mA or less 0 to 10V 2mA or less Resolution: 8bits R+ Communication Input (+) RS-485/422 R Communication Input ( ) S+ Communication Output (+) S Communication Output ( ) For MEMOBUS communication Operation by RS-485 or RS-422 communication is available. RS-485/422 MEMOBUS protocol 19.2kBPS max. 211

W= 30 mm min. (0.1 to 4.0 KW) 50 mm min. (5.5 and 7.5 KW) 100 mm min. Air Inverter Inverter Inverter Side 100 mm min. Air Inverter Heat Loss Three-phase 200 V Class Heat Loss W Model 3G3MV-A# 2001 2002 2004 2007 2015 2022 2040 2055 2075 Inverter Capacity kva 0.3 0.6 1.1 1.9 3.0 4.2 6.7 9.5 13 Rated Current A 0.8 1.6 3 5 8 11 17.5 25 33 Fin 3.7 7.7 15.8 28.4 53.7 60.4 96.7 170.4 219.2 Inside Unit 9.3 10.3 12.3 16.7 19.1 34.4 52.4 79.4 98.9 Total Heat Loss 13.0 18.0 28.1 45.1 72.8 94.8 149.1 249.8 318.1 Single phase 200 V Class Heat Loss W Model 3G3MV-A# B001 B002 B004 B007 B015 B022 B040 Inverter Capacity kva 0.3 0.6 1.1 1.9 3.0 4.2 6.7 Rated Current A 0.8 1.6 3 5 8 11 17.5 Fin 3.7 7.7 15.8 28.4 53.7 64.5 98.2 Inside Unit 10.4 12.3 16.1 23.0 29.1 49.1 78.2 Total Heat Loss 14.1 20.0 31.9 51.4 82.8 113.6 176.4 Three-phase 400 V Class Heat Loss W Model 3G3MV-A# 40P2 4004 4007 4015 4022 4040 4055 4075 Inverter Capacity kva 1.4 2.6 3.7 4.2 5.5 7.0 11 14 Rated Current A 1.8 3.4 4.8 5.5 7.2 8.6 14.8 18 Fin 15.1 30.3 45.8 50.5 58.2 73.4 168.8 209.6 Inside Unit 15.0 24.6 29.9 32.5 37.6 44.5 87.7 99.3 Total Heat Loss 30.1 54.9 75.7 83.0 95.8 117.9 256.5 308.9 212

Attachments Heatsink External Mounting Attachment When mounting an external cooling-fan to the 3G3MV, this attachment is required. AIR 100 (3.94) or more * 8.5 (0.33) D1 D2 D3 or more 100 (3.94) or more AIR 3G3MV Attachment Order Code Dimensions in mm D1 D2 D3 3G3MV-A2001 3G3MV-A2002 72606-EZZ08136A 69.2 12 30 3G3MV-A2004 72606-EZZ08136B 69.2 42 50 3G3MV-A2007 72606-EZZ08136C 69.2 62 70 3G3MV-A2015 73 58 70 72606-EZZ08136D 3G3MV-A2022 98 58 70 3G3MV-A2040 72606-EZZ08136F 78.6 64.4 70 3G3MV-A2055 3G3MV-A2075 72606-EZZ08136H 113.8 56.2 60 3G3MV-AB001 3G3MV-AB002 72606-EZZ08136A 69.2 12 30 3G3MV-AB004 72606-EZZ08136B 92.2 42 50 3G3MV-AB007 82 58 70 72606-EZZ08136D 3G3MV-AB015 98 58 70 3G3MV-AB022 72606-EZZ08136F 98.6 64.4 70 3G3MV-AB040 72606-EZZ08136G 115.6 64.4 70 3G3MV-A4002 72606-EZZ08136E 82 13.2 30 3G3MV-A4004 82 28 40 3G3MV-A4007 72606-EZZ08136D 82 58 70 3G3MV-A4015 3G3MV-A4022 98 58 70 3G3MV-A4030 3G3MV-A4040 72606-EZZ08136F 78.6 64.4 70 3G3MV-A4055 3G3MV-A4075 72606-EZZ08136H 113.8 56.2 60 213

Ordering Information System Configuration D Special Accessories 3G3IV-PCN329-E Inverter to PC cable Sydrive Configurator software DIN attachment 3G3IV-PZZ8122@ Second analog input cable 3G3MV-PCN-CN2 JVOP-144 Remote Digital Operator With potentiometer JVOP146 Remote Digital Operator Without potentiometer 3G3IV-PCN126/326 Digital Operator Extension Cable A Line Filter E Braking Accessories R S T 3G3MV-PFI@ Input Noise Filter LKEB@ Braking Resistor Unit CDBR@B Braking Unit ERF150WJ@ Braking Resistor Power Supply B Communication unit C PLC Option unit A Line Filters Inverter Line filter Voltage Model 3G3MV-A Model 3G3MV- Rated current (A) Weight (kg) Dimensions 2001 / 2002 / 2004 / 2007 PFI2010-SE 10 0.8 82x50x194 3-Phase 200 V AC 2015 / 2022 PFI2020-SE 20 1.0 111x50x169 2040 PFI2030-SE 30 1.1 144x50x174 2055 / 2075 PFI2050-SE 50 2.3 184x56x304 B001 / B002 / B004 PFI1010-SE 10 0.6 71x45x169 Single-Phase 200 V AC B007 / B015 PFI1020-SE 20 1.0 110x50x169 B022 PFI1030-SE 30 1.1 144x50x174 B040 PFI1040-SE 40 1.2 174x50x74 4002 / 4004 PFI3005-SE 5 1.0 111x45x164 3-Phase 400 V AC 4007 / 4015 / 4022 PFI3010-SE 10 1.0 111x45x169 4040 PFI3020-SE 15 1.1 144x50x174 4055 / 4075 PFI3030-SE 30 2.3 184x56x304 214

MIN MAX Type Name Description Function 3G3MV-PDRT2 Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through DeviceNet communication with the host controller. B Communication option board SI-P1/V7 SI-S1/V7 DeviceNet option card Profibus-DP option card CANopen option card Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through Profibus-DP communication with the host controller. Used for running or stopping the inverter, setting or referencing parameters, and monitoring output frequency, output current, or similar items through CANopen communication with the host controller. C PLC option D Accessories 3G3MV-P10CDT-E 3G3MV-P10CDT-E-DRT PLC option PLC option with DeviceNet Name Description Installation JVOP-146 Full PLC featrues, wireless installation and seamless access to the inverter parameters and analogue/digital inputs and outputs. Standard Omron tools can be used for programming RS422/485 Same features than standard model Calendar / Clock Battery 4-4.4 DIA. MTG HOLES 11 (0.43) 58 (2.28) DATA (15.5) STOP 80 (3.15) 50 (1.97) 68 (2.68) Remote digital operator without potentiometer 23.1 (0.91) 78 (3.07) 88 (3.46) 1.7 5 (0.07) (0.2) 12.2 (0.48) 10.5 (0.41) 30.4 (1.20) 18.2 (0.72) 56 (2.20) 4-M4 SPOT FACING DEEP 3.5 (0.14) Digital operator JVOP-144 11 (0.43) 58 (2.28) DSPL DATA ENTER RUN STOP RESET 15.5 (0.61) 70 (2.76) DIGITAL OPERATOR JVOP-140 4-4.4 DIA. MTG HOLES 80 (3.15) 50 (1.97) 68 (2.68) Remote digital operator with potentiometer 23.1 (0.91) 78 (3.07) 88 (3.46) 5 (0.2) 1.7 (0.07) 12.2 (0.48) 9.3 (0.37) 10.5 (0.41) 30.4 (1.20) 18.2 (0.72) 56 (2.20) 4-M4 SPOT FACING DEEP 3.5 (0.14) 15.5 (0.61) 70 (2.76) Accessories 72606-CVS31060 Blank cover ----- 3G3IV-PEZZ0838BA Digital operator case same as JVOP-144 without operator Digital operator extension cable 3G3IV-PCN126 1 meters ----- 3G3IV-PCN326 3 meters 3G3IV-PCN329-E PC configuration cable ----- Sysdrive Configurator Computer software Configuration and monitoring software tool 215

DIN Track Mounting Bracket 3G3IV-PZZ08122A 3G3IV-PZZ08122B (35.1) DIN track Four, M4 tap Side View (Common to all the Units) Four, M4 tap 3G3IV-PZZ08122C 3G3IV-PZZ08122D Four, M4 tap Four, M4 tap Inverter DIN Track Mounting Bracket 3-phase 200 V AC 3G3MV-A2001/-A2004/-A2007 3G3IV-PEZZ08122A 3G3MV-A2015/-A2022 3G3IV-PEZZ08122B 3G3MV-A2040 3G3IV-PEZZ08122C Single-phase 200 V AC 3G3MV-AB001/-AB002/-AB004 3G3IV-PEZZ08122A 3G3MV-AB007/-AB015 3G3IV-PEZZ08122B 3G3MV-AB022 3G3IV-PEZZ08122C 3G3MV-AB040 3G3IV-PEZZ08122D 3-phase 400 V AC 3G3MV-A4002/-A4004/-A4007/-A4015/-A4022 3G3IV-PEZZ08122B 3G3MV-A4040 3G3IV-PEZZ08122C 216

E Braking Unit, Braking Resistor Unit Voltage Inverter Max. Applicable Motor Output kw Inverter Model 3G3MV-A# Inverter-mounted Type (3 %ED, 10 sec max) Braking Resistor Unit Separately-installed Type (10 %ED, 10 sec. max.) 200V (Single-/ Three- Phase) 400 V (Three- Phase) Threephasphase Single- Model Resistance Torque % Model Resistor Spec. Braking No. of Braking ERF- No. of LKEB- (Per One Unit) Torque % Connectable Min. Resistance Ω 150WJ_ Ω Used # W Ω Used 0.12 2001 B001 401 400 1 220 300 0.25 2002 B002 401 400 1 220 300 0.55 2004 B004 201 200 1 220 20P7 70 200 1 220 200 1.1 2007 B007 201 200 1 125 20P7 70 200 1 125 120 1.5 2015 B015 101 100 1 125 21P5 260 100 1 125 60 2.2 2022 B022 700 70 1 120 22P2 260 70 1 120 60 4.0 2040 B040 620 62 1 100 23P7 390 40 1 125 32 5.5 2055 25P5 520 30 1 115 9.6 7.5 2075 27P5 780 20 1 125 9.6 0.37 4002 751 750 1 230 750 0.55 4004 751 750 1 230 40P7 70 750 1 230 750 1.1 4007 751 750 1 130 40P7 70 750 1 130 510 1.5 4015 401 400 1 125 41P5 260 400 1 125 240 2.2 4022 301 300 1 115 42P2 260 250 1 135 200 3.0 4030 4.0 4040 401 400 2 105 43P7 390 150 1 135 100 5.5 4055 45P5 520 100 1 135 32 7.5 4075 47P5 780 75 1 130 32 Connections for braking resistor Braking Resistor Unit ERF-150WJ 3-phase Power Supply MCCB 3G3MV Braking Resistor Motor Note: Prepare mounting screws (2-M4x8 tapped screws). Screws 8mm or more and general metric screws cannot be used. Connections for braking resistors unit Braking Resistor Unit OVERLOAD RELAY TRIP CONTACT MTG Screw L1(R) POWER L2(S) SUPPLY 3-PHASE L3(T) THRX OFF ON MC MC SA BRAKING RESISTOR UNIT OVERHEAT CONTACT THRX 1 2 SA MC Use sequencer to break power supply side on overload relay trip contact MCCB FLT-A FLT-B TRX SA MC B1 L1(R) L2(S) L3(T) 1 2 P B 3G3MV B2 BRAKING RESISTOR UNIT T1(U) T2(V) T3(W) IM C 30 or more A 30 or more D B 150 150 or more 150 or more TRX FAULT CONTACT 217

Voltage 200V Class 400V Class Model LKEB-# Dimensions in mm A B C D MTG.Screw Approx. Mass kg 20P7 105 275 50 260 M5x3 3.0 21P5 130 350 75 335 M5x4 4.5 22P2 130 350 75 335 M5x4 4.5 40P7 130 350 75 350 M5x4 5.0 25P5 250 350 200 335 M6x4 7.5 27P5 350 350 200 335 M6x4 8.5 40P7 105 275 50 260 M5x3 3.0) 41P5 130 350 75) 335 M5x4 4.5 42P2 130 350 75) 335 M5x4 4.5 43P0 43P7 130 350 75 335 M5x4 5.0 45P5 250 350 200 335 M6x4 7.5 47P5 350 350 200 335 M6x4 8.5 AC Reactor L1(R) L2(S) L3(T) MCCB AC REACTOR U V W X Y Z L1(R) L2(S) L3(T) 3G3MV T1(U) T2(V) T3(W) MOTOR IM Be sure to connect AC reactor on inverter input side [L1 (R), L2 (S), L3 (T)]. DC Reactor 200 V Class 400 V Class Max. Applicable Current Value Inductance Code No. Max. Applicable Current Value Inductance Code No. Motor Output kw A mh Motor Output kw A mh 0.12 2.0 2.0 X 002764 ------ 0.25 2.0 2.0 X 002764 0.2 0.55 2.5 4.2 X 002553 0.4 1.3 18.0 X 002561 1.1 5 2.1 X 002554 0.75 2.5 8.4 X 002562 1.5 10 1.1 X 002489 1.5 5 4.2 X 002563 2.2 15 0.71 X 002490 2.2 7.5 3.6 X 002564 4.0 20 0.53 X 002491 4.0 10 2.2 X 002500 5.5 30 0.35 X 002492 5.5 15 1.42 X 002501 7.5 40 0.265 X 002493 7.5 20 1.06 X 002502 DC Reactor MCCB Motor 3G3MV Max. Applicable Motor Output kw 0.12 200 V Class 400 V Class Current Value A Inductance mh Code No. Max. Applicable Motor Output kw Current Value A -------- Inductance mh Code No. 0.25 0.2 5.4 8 X010048 0.55 0.4 3.2 28 X010052 1.1 0.75 1.5 1.5 5.7 11 X010053 2.2 18 3 X010049 2.2 4.0 4.0 12 6.3 X010054 5.5 5.5 36 1 X010050 23 3.6 X010055 7.5 7.5 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. I20E-EN-01 In the interest of product improvement, specifications are subject to change without notice. 218