Fire & Explosion Risks in Service Stations



Similar documents
FIRE SAFETY GUIDANCE NOTE Risk Assessments for Petrol Filling Stations Required Under Fire Safety Legislation

Petrol Storage Information Note

Waste Oil Collection / Storage

EXPLOSIVE ATMOSPHERES - CLASSIFICATION OF HAZARDOUS AREAS (ZONING) AND SELECTION OF EQUIPMENT

MOTOR FUEL DISPENSING SAFETY

Site and Storage Conditions for Class 3.1 Flammable Liquids

A Job Safety Execution Plan is required. mixtures of the above called, natural gas liquids (NGL's) refined products and their components

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Safe use of liquefied petroleum gas (LPG) at small commercial and industrial bulk installations

EXPERIMENT NO. 3. Aim: To study the construction and working of 4- stroke petrol / diesel engine.

Petroleum (Consolidation) Regulations 2014

LPG, Flammable Liquids, Toxic and Corrosive Substances

GUIDELINES - Gas Inspection Regulations 1. Recommendations for camping site owners

STORE HAZARDOUS SUBSTANCES SAFELY. incompatibles gas cylinders

Inspection Location Standards

BP WIND ENERGY POLICIES AND PROCEDURES

Cyan 100% Magenta 76% Yellow 0 Black 27% Wetstock Reconciliation at Fuel Storage Facilities. An Operator s Guide

FLAMMABLE LIQUIDS COMPLIANCE NOTE

Explosion of a gasoline vapour cloud formed in a hydrocarbon loaded effluents storage tank 10 December 1999 Arquata Scrivia Italy

Wilkins Safety Group

A guide for service station operators

Queen's University Environmental Health and Safety

Risk Assessment Based Environmental Management Systems for Petroleum Retail Stores

ENGINEERED DRAWINGS FOR PETROLEUM STORAGE TANKS

How To Manage A Fire Explosion

PPG3 April pollution prevention guidelines. 1. Introduction. Use and design of oil separators in surface water drainage systems: PPG 3

Flammable liquid classes: Combustible Liquid Classes. Class IC. Class II. Class IB F.P. below 22.8 C (73 F), boiling point at or above 37.

HealthandSafetyOntario.ca. Introduction. Storage Containers. Storing Flammable Liquids

SPILL PREVENTION, CONTROL AND COUNTERMEASURE PLAN

Emergency Response Guide

INTERNATIONAL STANDARD

Presented by: Rich Perry Marsh Risk Consulting

PROCEDURES PREVENTION OF ACCIDENTAL IGNITION

Ethanol Vehicle and Infrastructure Codes and Standards Citations

CHAPTER PETROLEUM CONTACT WATER

ACTIVITY NAME. Training Requirements for Spill Prevention Control and Countermeasures (SPCC) 40 CFR Part 112 Naval Air Station Corpus Christi Texas

ŠkodaOctavia Supplement - for vehicles with LPG drive

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

REFERENCE NUMBER : PPC/54. POLLUTION PREVENTION AND CONTROL ACT 1999 POLLUTION PREVENTION & CONTROL (ENGLAND AND WALES) REGULATIONS 2000(as amended)

SPILL PREVENTION AND RESPONSE PLAN TEMPLATE FOR BUSINESSES IN DAYTON S SOURCE WATER PROTECTION AREA

FUELING AND FUEL STORAGE

PRECAUTIONS ON TANKER AND TERMINAL DURING CARGO HANDLING

MAINE DEPARTMENT OF ENVIRONMENTAL PROTECTION

Notes. Material 1. Appropriate Flammable Liquids

IGEM/UP/16 Communication 1756

Gas-Fired, Residential Storage Type Water Heaters

Notes. Material 1. Personal Protective Equipment 2.

Portable petrol storage containers

LNG Fuel Tank System LNG Tank overview

Environmental Management System Procedures

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

Guide to Certification for Retail Hardware Stores

PROPANE AUTOGAS REPAIR AND MAINTENANCE FACILITY REQUIREMENTS

Civil Engineering Sector Labour-Management Health and Safety Committee

Controlling Electrostatic Ignition Hazards during Fuel Delivery at Forecourts

LIQUEFIED PETROLEUM GASES

HSE information sheet. Fire and explosion hazards in offshore gas turbines. Offshore Information Sheet No. 10/2008

GUIDELINE FOR SAFETY IN THE HANDLING OF FLAMMABLE LIQUIDS

Fuel Tanker Online Content Monitoring. Petroleum Products Real Time! Solution for Modern Businesses

Safety Manual Title: Spill Prevention & Response Review Date: 6/1/2014

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

DPR DEPARTMENT OF PETROLEUM RESOURCES

Farm Fuel Tank Safety Guide

Select the Right Relief Valve - Part 1 Saeid Rahimi

Outline. Background. NFPA 820 Applicability to Wastewater Treatment Facilities. Hazardous Area Classifications. Treatment Plant Area Classifications

Installation Guidance: CNG Refueling Stations

Natural Gas Emergencies

JOINT CBA AND SIA GUIDANCE FOR THE STORAGE OF FLAMMABLE LIQUIDS IN SEALED PACKAGES IN SPECIFIED EXTERNAL STORAGE AREAS

ALLEGANY WIND POWER PROJECT CONSTRUCTION SPILL PREVENTION PLAN

Fire Pump Plan Review March 2010

Emergency Response Guide

Spill Prevention, Control and Countermeasure (SPCC) Rule

Design of a Fuel Oil Storage Facility

TECHNICAL INFORMATION

RESTRICTED ACCESS AND CONFINED SPACES

Natural Gas Information Contents

NFPA31FuelOilPiping 1 Revised

Healthcare Help Supporting Health Providers. Module 2 Resources for Fire Warden Refresher Training HH.NET LTD

FIRE PREVENTION PLAN

Flammable Liquids Storage

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Critical Regulations SUMMARY OF. Stormwater Management Regulations (National Pollutant Discharge Elimination System or "NPDES ) 40 CFR 122.

Technical Requirements for Aboveground Storage Tanks (ASTs) Storing Class IIIB Liquids (other than used oil)

September 2008 AFC (2) Page 1 of 5. Maximum Size and Aggregate Capacities of Aboveground Storage Tank Systems at Fuel Dispensing Stations

Oxy-Fuel Gas Welding. Given a functional oxy-fuel gas unit, instruction and demonstration of use, each student will be able to:

Arctic King Fuel Tanks meet the Environment Canada TECHNICAL REQUIREMENTS FOR COLLAPSIBLE FABRIC STORAGE TANKS (BLADDERS) - December 17, 2009

Propane Autogas Fleets Safety & Training

Controlling fire and explosion risks in the workplace

Reference in RID/ADR (restructured) to published standards and standards in preparation at CEN TC 23/256/261/268/286/296

Emergency Response Guide

FLAMMABLE AND COMBUSTIBLE LIQUIDS. n OSHA Changes

TECHNICAL ADVISORY BULLETIN

WORK IN CONFINED SPACES

Standards and best practice guidelines for vapour recovery at petrol service stations. Department of Environment, Climate Change and Water NSW

Commercial Garages, Repair, and Storage

considering natural gas vehicles for your fleet? get the facts

Gallagher Vapour Recovery Monitoring

Natural Resources Conservation Authority Guidelines for Secondary Containment of Hazardous Liquids stored Above-ground

Transcription:

Fire & Explosion Risks in Service Stations Petrol Vapour Petrol gives off highly flammable vapour even at very low temperatures. Because of the flammability of petrol vapours, service stations carry a risk of fire or explosion not common to other types of retail outlets. Ignition of petrol vapours can happen if vapour comes into contact with a heat source capable of igniting it. An ignition spark might come from an electrical switch, a cigarette or a static electrical discharge. Petrol vapour is heavier than air and tends to sink to the lowest possible level of its surroundings and may gather in tanks, cavities, drains, pits or other low points and will travel across the ground due to gravity (down-hill) or may be carried in the direction of the wind. Hazardous Area Zoning of Service Stations In order to prevent the risk of ignition, the service station must be zoned on the basis of the probability of an explosive vapour mixture forming. Hazardous areas, as found around a service station, are classified into three categories as illustrated opposite: Zone 0 Zone 1 Zone 2 Zone Classification for Vapours flammable atmosphere is continually present or present for long periods. flammable atmosphere is likely to occur in normal operation. flammable atmosphere is not likely to occur in normal operation and, if it occurs, will exist for a short period.

The zoning of a service station should be carried out by someone who is competent to do it. The zones should be marked clearly on drawings of the service station which should be available at any time at the station. The zones are in 3 dimensions so the drawings will need to indicate plans and elevations, to show their full extent. These zoning diagrams should be contained in a document called an Explosion Protection Document (EPD). Any electrical equipment (or mechanical equipment capable of generating enough heat to cause ignition) must be suitably rated and certified before they can be installed in a hazardous zone within the station. To ensure the quality of the electrical installation, all service stations must have their electrical installation tested and certified every 3 years by a competent electrician familiar with explosive atmospheres. Fuel Leaks in the Environment If released into the environment, petrol and diesel pollute the soil and water supplies. Whenever petrol escapes from an underground storage tank or pipelines, it can travel significant distances. Petrol vapours can find their way into basements of buildings and public drains with serious consequences should the vapours come into contact with an ignition source. The level of risk associated with fuel leakage means early detection of leaks is essential. Immediate corrective action must be taken when leaks are detected. Therefore there is need for consistent and accurate monitoring of fuel delivered, stored and dispensed at any service station in order to detect leaks from each underground tank and connected pipeline. Fuel Delivery Regulations require that petrol storage operators supervise all petrol deliveries. However, where the local licensing authority gives prior consent, a petrol store may be modified to allow deliveries under the control of the road tanker driver only.

Graphic 1: Example of side elevation of a petrol station illustrating hazardous area zones EX rated equipment required in all identified zones. Each site must carry out a site specific assessment. UNVENTILATED GARAGE INSPECTION PIT Vent stack: radial zone around vent outlet. Zone extending to ground may be zone 1 or 2 depending on vapour recovery. FUEL STORAGE TANK FLAMMABLE MATERIAL IN LIQUID FORM ZONE 0 ZONE 1 ZONE 2

Graphic 2: Example of a plan view of a petrol station illustrating hazardous area zones EX rated equipment required in all identified zones. Each site must carry out a site specific assessment. EXAMPLE OF HAZARDOUS ZONE DRAWING REQUIRED FOR A TYPICAL PETROL FILLING STATION WASTE AREA DIESEL TANK VENT STACK SEPARATOR SEPARATOR VENT DIESEL PETROL PETROL PETROL SALES SHOP ZONE 0 UNDERGROUND OFFSET FILL ZONE 1 ZONE 2

NOMINAL AREAS OF HAZARDOUS ZONES TO BE INDICATED ON THE HAZARDOUS ZONE DRAWING: ~ Zone 0 Within any access chamber or pit in which there are tanker delivery hose connection point(s). Within an oil separator (petrol interceptor). Zone 1 1m radius around the road tanker delivery and vapour return hose connections extending down to ground level. 1m radius along the delivery hose route from the tanker connection point(s) to the tank connection point(s). 1m radius from a tank fill point (above ground). 1m radius from the edge the chamber if fill point is below ground. Within petrol tank access chambers which do not have tank fill points. 2m (1.5m) radius around tank venting point(s) which do not have a stage 1b vapour recovery system, radial zone extending to ground as zone 2 (Graphic 1: vent stack). 1m radius around a venting point of an oil separator (petrol interceptor), radial zone extending to ground as zone 2 (Graphic 1: vent stack). Within the access chamber of an oil separator (petrol interceptor). Within, hose length plus 0.5m (4.25m) radius of a petrol delivery hose connection on a dispenser (without stage 2 vapour recovery) and extending to 1.2m from ground. Zone 2 4m radius of tanker delivery hose connection point(s). 4m (4.25m) radius of above ground off set fill connection(s) and (4.25m from the centre point of a manhole opening direct fill point). Note: 1 m radius around vapour return hose connection point. 2m radius around tank venting points where the site has stage 1b vapour recovery installed extending to ground. 2m radius from the edge of an oil separator (petrol interceptor) access chamber. Within, hose length plus 0.5m (4.25m) radius of a petrol delivery hose connection on a dispenser (with stage 2 vapour recovery in operation) and extending to 1.2m from ground. Additional hazardous zones to those identified in this guide may be present and must be identified on site drawings e.g. where LPG or other highly flammable motor fuels are stored and dispensed. The hazardous area zone guidance above is based on the EI/APEA Blue Book, however some distances may vary slightly according to national legislation, S.I. 311 of 1979. National legislative provisions are indicated in brackets above, these must be applied in practice, but where the guidance suggests a larger zone, this may also be applied. Convention dictates that zones are marked in black and white for clarity. In this guidance document colour has been used to highlight the different zones and it is for illustrative purposes only. Further Information: For examples of hazardous zoned areas on forecourts refer to the industry Blue Book, EI/APEA publication on Design, Construction, Maintenance and Decommissioning of filling stations (3rd edition) available at www.apea.org.uk Driver controlled deliveries are subject to additional controls, a copy of these provisions can be obtained from the Health and Safety Authority web site, www.hsa.ie along with other guidance material specific to petroleum storage.