DOE Data Center Energy Efficiency Program



Similar documents
DC Pro Assessment Tools. November 14, 2010

Data Center Energy Use, Metrics and Rating Systems

Identifying Energy Saving Opportunities in the Data Center

Imperial College 3 March 2009 Green Data Centers: An Overview

How Does Your Data Center Measure Up? Energy Efficiency Metrics and Benchmarks for Data Center Infrastructure Systems

Benchmarking results from Indian data centers

Figure 1: Comparison of Projected Electricity Use,

Guideline for Water and Energy Considerations During Federal Data Center Consolidations

Energy Efficient High-tech Buildings

FEAR Model - Review Cell Module Block

Green Data Centre Design

for Energy Efficiency Parminder Sandhu, P. Eng

Recommendations for Measuring and Reporting Overall Data Center Efficiency

Why Data Center Design and Innovation Matters

Case Study: Opportunities to Improve Energy Efficiency in Three Federal Data Centers

AIA Provider: Colorado Green Building Guild Provider Number: Speaker: Geoff Overland

Recommendations for Measuring and Reporting Overall Data Center Efficiency

Re Engineering to a "Green" Data Center, with Measurable ROI

Harmonizing Global Metrics for Data Center Energy Efficiency

Data Center Industry Leaders Reach Agreement on Guiding Principles for Energy Efficiency Metrics

Data Centers: How Does It Affect My Building s Energy Use and What Can I Do?

1.4 PUE The New Mandate for Federal Data Center Energy Efficiency. Strategic Sustainability Performance Plan (SSPP)

Data Center Combined Heat and Power Benefits and Implementation. Justin Grau, Google Inc. Sam Brewer, GEM Energy

Electrical Systems. <Presenter>

Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint

World s Greenest High Performance Data Center

Data Center Energy Efficiency. SC07 Birds of a Feather November, 2007 Bill Tschudi wftschudi@lbl.gov

Control of Computer Room Air Handlers Using Wireless Sensors. Energy Efficient Data Center Demonstration Project

San Francisco Chapter. Deborah Grove, Principal Grove-Associates

Richard Sweetser, Principal Investigator, EXERGY Partners Corp. Phone:

FEDERAL UTILITY PARTNERSHIP WORKING GROUP SEMINAR April 22-23, 2015 Nashville, TN

BCA-IDA Green Mark for Existing Data Centres Version EDC/1.0

ABSTRACT DCMCCT PROJECT OVERVIEW

Data Center Leadership In the DOE Better Buildings Challenge

Understanding Power Usage Effectiveness (PUE) & Data Center Infrastructure Management (DCIM)

Green Data Centers. Energy Efficiency Data Centers. André ROUYER Director of Standardization & Environment. The importance of standardization

EPA Report to Congress on Server and Data Center Energy Efficiency

Rules of Thumb Energy Efficiency in Buildings

How To Save Money On Energy Efficiency

Jonathan Mitchell CDS Research Project April 18, 2012

Energy Audits Waste Water Treatment Plants

Data Center RD&D at EPRI

CRITICAL COOLING FOR DATA CENTERS

Energy Efficiency Opportunities in Federal High Performance Computing Data Centers

Energy Strategic Plan Los Angeles Community College District Community College League Conference

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

Self-benchmarking Guide for Data Center Infrastructure: Metrics, Benchmarks, Actions Sponsored by:

Energy Efficiency and Availability Management in Consolidated Data Centers

DEMONSTRATION OF DATA CENTER ENERGY USE PREDICTION SOFTWARE

Best Practices for Data Centers Using Your FEC Experience to Take the Next Step

Data Centers: Definitions, Concepts and Concerns

Specialty Environment Design Mission Critical Facilities

Deep Dive Think Tank: Energy Costs and Strategies for Reduction

Energy Conservation for Colleges and Universities

Combined Heat & Power. Discussion with Connecticut Energy Advisory Board. February 23, 2010

Reducing Data Center Loads for a Large-Scale, Net Zero Office Building

Combined Heat & Power (CHP) UGI Webinar. Presented By: Barry Wentzel, UGI Utilities Eric Burgis, Energy Solutions Center June 18, 2013

Overview of Green Energy Strategies and Techniques for Modern Data Centers

Report to Congress on Server and Data Center Energy Efficiency Public Law U.S. Environmental Protection Agency ENERGY STAR Program

EU Code of Conduct for Data Centre Efficiency

Performance Contracting

University of Melbourne Symposium on ICT Sustainability Dan Pointon 25 November 2008

WHITE PAPER. How To Build A Real Green Data Centre. Contents. Part 1: Drivers for Data Centre energy efficiency. February 2008

The Green Data Center

Smarter Data Centers. Integrated Data Center Service Management

General Recommendations for a Federal Data Center Energy Management Dashboard Display

Energy Efficiency in New and Existing Data Centers-Where the Opportunities May Lie

Enabling an agile Data Centre in a (Fr)agile market

DATA CENTRE DESIGN AND

GENERAL MOTORS ENERGY MANAGEMENT SYSTEMS

Managing Power Usage with Energy Efficiency Metrics: The Available Me...

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Wireless Sensor Technology for Data Centers

Managing Data Centre Heat Issues

Greening Data Centers

Green IT Solutions From Desktop to Datacenter. Dave Spear Sr. Engagement Manager & Sustainability Advocate dave.spear@microsoft.

EnergySTEP (Sustainability Tiered Efficiency Program) Our Approach to Energy Efficiency

Increasing Energ y Efficiency In Data Centers

Power Usage Effectiveness (PUE) & Data Center Infrastructure Efficiency (DCiE) Progress

Measurement & Verification Plan

CIBSE ASHRAE Group. Data Centre Energy Efficiency: Who, What, Why, When, Where & How

Demonstration of Data Center Energy Use Prediction Software

Bytes and BTUs: Holistic Approaches to Data Center Energy Efficiency. Steve Hammond NREL

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

A Market Transformation Programme for Improving Energy Efficiency in Data Centres

Legacy Data Centres Upgrading the cooling capabilities What are the options?

Agenda. Part I: Introduction to OptimumHVAC. Part II: Initial Energy Savings Analysis for MCO Main Terminal. Part III: Case Studies & Conclusion

Reducing Data Center Energy Consumption

Protecting Our Information, Protecting Our Resources

Data Centers That Deliver Better Results. Bring Your Building Together

Harmonizing Global Metrics for Data Center Energy Efficiency. Global Taskforce Reaches Agreement Regarding Data Center Productivity.

SUSTAINABLE ENERGY ACTION PLAN AND SOLAR PILOT PROJECTS

This 5 days training Course focuses on Best Practice Data Centre Design, Operation and Management leading to BICSI credits.

How to Earn the LEED Green Power Credit

The Green Grid, Metrics and DCMM. Presented by: Jay Taylor

Sustainability Watch. Data Center Energy Efficiency. Data Center Energy Efficiency Is Fast Becoming a Priority. Watch List.

Silicon Valley Power Data Center Program Rebate Application

Improving Sustainability in Campus Data Centers Click To Edit Master Title Style

Unleashing Stranded Power and Cooling Data

LEVEL 3 DATA CENTER SERVICES IN OMAHA, NEBRASKA HIGH AVAILABILITY ENTERPRISE COMPUTING BUSINESS DEMANDS IT. LEVEL 3 DELIVERS IT.

Transcription:

DOE Data Center Energy Efficiency Program Paul Scheihing U.S. Department of Energy Energy Efficiency and Renewable Energy April 2009 1

DOE Industrial Technologies Program Worki king to improve th e energy efficiency of U.S. industry U.S. industry consumes 32 quadrillion Btu per year -- almost 1/3 of all energy used in the nation Partnerships with energy-intensive industries are key to ITP s success: 5 quads of energy savings, 86 MMTCE reduction Save Energy Now is working to reduce industrial energy intensity 25% by 2017 2

Data Centers are INFORMATION FACTORIES Resembling large industrial facilities 3

Containing Specialized Equipment 4

Save Energy Now: Products & Services Tools Process Heating Steam Systems Plant Energy Profiler Motors & Pumps Fans Training Information Website Information Center Tip Sheets Case studies Webcasts Basic Advanced Qualified Specialist Assessments Energy Savings Assessments Industrial Assessment Centers 5

Energy Issues Abound Data centers are an important and growing market Data centers are energy intensive Server racks now designed for more than 25+ kw Typical facility ~ 1MW, can be > 20 MW Cost of electricity approaching capital cost of IT equipment 1.5% of all electricity in the U.S. in 2006 ($4.5 Billion) Growing at 12% per year (will double in 5 years) Power and cooling constraints in existing facilities Utility distribution constraints Currently no consistent metric to measure output Perverse incentives -- IT and facilities costs separate 6

Data Center Energy Efficiency = 15% (or less) (Energy Efficiency = Useful computation / Total Source Energy) 100 Units Source Energy Typical Data Center Energy End Use Power Conversions & Distribution 35 Units Power Generation 33 Units Delivered Cooling Equipment Server Load /Computing Operations 7 7

Potential Savings 20-40% savings typically possible Aggressive gg strategies better than 50% savings Extend life and capacity of existing infrastructure Save Energy Now has developed tools to: Estimate where energy is going How use compares to others Identify savings opportunities 8

Energy Efficiency Opportunities Server innovation Virtualization High efficiency power supplies Load management Better air management Move to liquid cooling Optimized chilled-water plants Use of free cooling Heat recovery Power Conversion & Distribution Server Load/ Computing Operations Cooling Equipment High voltage distribution High efficiency UPS systems Efficient redundancy strategies Use of DC power Alternative Power Generation On-site generation Including fuel cells and renewable sources CHP applications (Waste heat for cooling) 9

DCiE = Data Center Infrastructure Efficiency DCiE = Energy for IT Equipment Total Energy for Data Center Typical DCiE (Data Center Infrastructure Efficiency) < 0.5 IT electrical l and cooli ling systems are far from optimized Less than half of the energy is for the servers Power Utilization Effectiveness =PUE = 1 / DCiE Typical PUE > 2.0 10

Data Center Performance Varies in Cooling and Power Conversion DCiE Data Center Infrastructure Efficiency Energy for IT Equipment DCiE = Total Energy for Data Center Typical DCiE (Data Center Infrastructure Efficiency) < 0.5 IT electrical and cooling systems are far from optimized Less than half of the energy is for the servers Infrastructure Infrastructure Infrastructure IT Energy IT Energy IT Energy Typical Practice Better Practice Best Practice DCiE < 0.5 DCiE = 0.7 DCiE = 0.85 11

DCeP = Data Center Energy Productivity DCeP = Work Output of Data Center (Bytes) Total Energy for Data Center (BTU) DCeP under development by Green Grid consortium 12

DC Pro tool 2008 results Over 1,000 people have registered to use tool 15 companies beta tested, including 11 Green Grid companies Companies using tool in procurement specs and energy management team planning 13

Save Energy Now On-line profiling tool: Data Center Pro INPUTS Description Utility bill data System information IT Cooling Power On-site gen OUTPUTS Overall picture of energy use and efficiency End-use breakout Potential areas for energy efficiency improvement Overall energy use reduction potential 14

2008 Case Study Results Lucasfil film and Verizon case studies with potential cost savings identified of $343,000 and $181,000 per year, respectively Additional case studies desired 15

Data Center Overview Lucasfilms Case Study Located at the Presidio of San Francisco National Park 23-acre facility/13,500 square feet (data center) Houses a render farm (cluster of computers that work to process digital images), file servers, and storage systems More than 4,300 processors Cooled by a central chilled water plant serving the Lucasfilm campus Receives back-up power through UPS systems 16

Case Study: Lucasfilms Ltd. (cont d) Recommended Solutions and cost savings Remove redundant UPS systems ($12,000/year) Turn servers off during downtime ($30,000/year) 000/ Stage chillers to maintain high load factor ($10,000/year) Operate UPS in switched by-pass mode ($98,000/year) Improve air flow ($89,000/year) Implement water-side economizer ($103,000/year) Install lighting controls ($1,000/year) Estimated Savings and Payback Cost Savings: $343,000 Energy Savings: 3,109,200 kwh Implementation costs: $429,500 Payback: 1.2 Years 17

DOE-Green Grid Goal for Energy Savings 2011 goal is 10% energy savin gs overall in U.S. data center 10.7 billion kwh Equivalent to electricity consumed by 1 million typical U.S. households Reduces greenhouse gas emissions by 6.5 million metrics tons of CO 2 per year Green Grid - DOE Energy Savings Goal; 10.7 billion kwh/yr by 2011 18

Industrial Technologies Program DC Pro tool suite & training Metrics & energy baselining Qualified specialists Case studies Certification of continual improvement Recognition of high energy savers Best practice information & training Best-in-Class guidelines R&D - technology development EPA Metrics Server performance rating & ENERGY STAR label Data center ENERGY STAR performance benchmarking Federal Energy Management Program Best practices showcased at Federal data centers Pilot adoption of Best-in-Class guidelines at Federal data centers Adoption of to-be-developed d industry standard for Best-in-Class at newly constructed Federal data centers Industry Tools Metrics Training Best practice information Best-in-Class guidelines IT work productivity standard 19

2008 Activity Tools and Assessment Protocols - DC Pro tool v1.0 released - Electrical assessment tool beta released - IT module initiated with Green Grid - Air management assessment tool alpha released HVAC Tool in development Training - Pilot trainings (5) - Developing joint training with ASHRAE and Green Grid 20

By 2011 Products DC Pro tool Assessment protocols Training curriculum Case studies Best practices Best-in-Class guidelines Technology R&D and demonstrations Market Delivery 200 Data Cener Certified Energy Practitioners Suppliers Engineering firms Utilities Associations and technical societies Data Center Results 10 billion kwh per year saved 3,000 people trained on tools and assessment protocols 1,500 data centers improve energy efficiency > 25% 200 data centers improve energy efficiency >50% 21

2009 Activity Tools and Assessment Protocols - Improve DC Pro tool - IT module released - Air management released - HVAC tool initiated Training - ASHRAE-Green Grid-DOE pilot trainings - Hold data center trainings at multiple events Develop and pilot Data Center Certified Energy Practitioner program Develop R&D program 22

Calls to Action More case studies especially data centers improving more than 25% Use DC Pro tools and provide feedback Staff and customers participate in training workshops Staff become Data Center Certified Energy Practitioners Participate in potential data center technology demonstration program 23 23

DOE Data Center program Information Tech. R&D program Paul Scheihing Gideon Varga www.eere.energy.gov/industry www.eere.energy.gov/industry www.eere.energy.gov/datacenters/ paul.scheihing@ee.doe.gov gideon.varga@ee.doe.gov 202-586-7234 202-586-0082 24

Links to Get Started: DOE Website: Sign up to stay up to date on new developments www.eere.energy.gov/datacenters Lawrence Berkeley National Laboratory (LBNL) http://hightech.lbl.gov/datacenters.html LBNL Best Practices Guidelines (cooling, power, IT systems) http://hightech.lbl.gov/datacenters-bpg.html ASHRAE Data Center technical guidebooks http://tc99.ashraetcs.org/ The Green Grid Association White papers on metrics http:// //www.thegreengrid id.org/gg_content/ t/ Energy Star Program http://www.energystar.gov/index.cfm?c=prod_development.server_efficiency Uptime Institute white papers www.uptimeinstitute.org 25