SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING



Similar documents
SECTION STANDING SEAM METAL ROOFING

SECTION PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK

GUIDELINE SPECIFICATIONS

SECTION STANDING SEAM METAL ROOF

Holiday Inn Express & Suites Covington (Newton County) 1. Standing-seam metal roofing, custom fabricated.

SECTION STANDING SEAM METAL ROOFING

Preformed Metal Roofing and Siding

SECTION METAL ROOF & WALL PANELS

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood

SECTION METAL WALL PANELS

238T Standing Seam Metal Roof System (SSMRS)

GUIDE SPECIFICATION. Manufacturer: DECRA Roofing Systems, Inc.

STANDING SEAM SHEET METAL ROOFING

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

SECTION PREFORMED METAL ROOF PANELS

GUIDE SPECIFICATION. Manufacturer: DECRA Roofing Systems, Inc.

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

A. Double lock standing seam, single element, metal roof panels.

CB-100 CB-150 CS-100 SL-100 SL-150 SLZ-1000

Rouse Life Sciences Roof Repair or Replacement SECTION

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Architectural. Roofing. Basis of Design

SECTION METAL ROOF SYSTEM

SECTION STANDING-SEAM METAL ROOF PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS

HHS J.W. Peavy Center Exterior Walls Waterproofing and Roof Replacement Project WBS # H SECTION STANDING SEAM METAL ROOFING

SECTION ROOFING TILE

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS

Asphalt Shingle Application Requirements

PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS

CHAPTER 7: Building Systems ROOFING SYSTEMS

Residential Roofing Guide

Shingle Installation Guide

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Standing Seam Roof Systems

Metal Building Systems Installation and Flashings & Details Guide. Table of Contents

1. Section "Composite Wall Panel System"

Slim Seam Architectural Design Manual

09/07/07 GLASSFIBER REINFORCED CEMENT (GRC) C. S. I. Spec Master Spec Page 1

INSTRUCTIONS FOR COORDINATION SECTION SOLID SURFACE FABRICATIONS

Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide

JANUARY, 2016 TR-7100 Windows (Fixed) 1 EC ALUMINUM WINDOWS Guide Specs

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

DENVER MODEL 30 X 30 SPECIFICATIONS

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

City of San Diego, CWP Guidelines

COLORADO MODEL. 35 x 65 SPECIFICATIONS

How To Build A Roof Tile Deck

CHAPTER VII. TITLE: STANDARDS FOR NEW ROOFING July 2015 CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS

SECTION ALUMINUM HANDRAIL AND RAILING SYSTEMS WITH DECORATIVE METAL PANEL INFILLS

HERITAGE WOODGATE LAMINATED ASPHALT SHINGLES Dallas, TX

CENTRIA SRS3 Structural Standing Seam Metal Roof Panels

BRIDGE & SUPPLY COMPANY. Installation Guide. Ultra Includes:

PART 1 GENERAL 1.1 SECTION INCLUDES

Sapa: SECTION ARCHITECTURAL ALUMINUM HANDRAILS AND RAILINGS

DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING. A. Vapor barrier (base ply); cover board at existing roof deck.

ROOFS - Guidance for Repair, Maintenance and Replacement

SECTION STANDING SEAM ROOF PANELS

Section Page Section Page

Discount Direct Metal Roofing Plus Rib Roofing Panels Installation Instructions

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

THERMOTEK SELF ADHESIVE MEMBRANE +G2 OVER WOOD SYSTEM DESCRIPTION SELF ADHESIVE OVER WOOD (8YR) BS-SA/CS

THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER POLYSOCYANURATE SYSTEM DESCRIPTION TORCH SYSTEM OVER POLYISO (15,17,19 YR) TH/BS-TH/CS

DIVISION 7 - THERMAL AND MOISTURE PROTECTION

The Butler MR-24 Standing Seam Roof Difference. A comparison between metal roof systems

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

THERMOTEK MODIFIED BITUMEN TORCH MEMBRANE OVER

ATLANTA MODEL SPECIFICATIONS

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

SECTION STANDING SEAM METAL ROOFING

A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

application instructions

Titan Old World Spanish Tile

Metal Roofing Practical Design

ENGINEERING SPECIFICATION FIBERGRATE MOLDED GRATING. January 24,

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

SECTION PRECAST CONCRETE STRUCTURES

Wastewater Capital Projects Management Standard Construction Specification

Commercial Roof Inspection Form

September 3, Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901

Installation Manual for STANDING SEAM ROOFING

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

Classic Products, Inc. ClickLock Standing Seam Installation Manual

Installation Guide MATTERHORN METAL ROOFING TO LAST A LIFETIME. MATTERHORN Standing Seam

SECTION EXPANSION CONTROL

SECTION SINGLE PLY MEMBRANE ROOFING. 4. Minor repair to adjacent clay tile roofing and flashings.

ITEM THERMOPLASTIC MEMBRANE ROOFING

SECTION COMPOSITE ROOF TILE SYSTEMS

Directions For Applying Malarkey Laminate Shingles

G VYCOR DECK PROTECTOR

SECTION COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

Nucor VR16 II TM Vertical Rib Standing Seam Roof System

INSTALLATION MANUAL For Grand Rib-3 / Multi Purpose / & Classic Rib Roofing Panels

VERTICAL LOCK Table of Contents

4572 N Old US 31, Rochester, IN Toll Free: Fax: DETAIL MANUAL. and guide to Ramco Supply products

Transcription:

SECTION 07720 PREFORMED METAL STANDING SEAM ROOFING PART ONE GENERAL DESCRIPTION This section includes pre-formed standing seam metal roofing and related flashings, closures, trim and accessories including, but not limited to concealed anchor clips, fascia, drip edge, valley, hip and ridge closure, gable flashings, base and counter flashings, gutters, downspouts and roof penetration flashings. RELATED WORK Section 06100: Rough Carpentry Section 07600: Sheet Metal Flashing & Trim SYSTEM DESCRIPTION Performance Requirements: Provide manufactured roof panel assembly complying with performance requirements indicated and capable of withstanding structural movement, thermally-induced movement, and exposure to weather without failure or infiltration of water into the building interior. REFERENCE STANDARDS American Iron and Steel Institute AISI: Light Gauge Cold-Formed Steel Design Manual American Society of Testing Materials: ASTM A525, A653, A792, B209, E283 E330, E1592, E1646, E1680 Sheet Metal and Air Conditioning Contractors National Association SMACNA: Architectural Sheet Metal Manual QUALITY ASSURANCE Installer Qualifications: Engage an experienced installer who has, for a minimum of ten (10) years, successfully completed roof panel projects similar in material, design, scope and extent to that for this project. SUBMITTALS Product Data: Submit manufacturer s product specifications, standard details, certified product test results, installation instructions and general recommendations, as applicable to materials and finishes for each component and for total system of pre-formed roof panels.

Shop Drawings: Submit small-scale panel layout, details for edge, flashing and penetration conditions, joints, corners, panel profile, supports, anchorages, closures, snow guards and special details. Distinguish between factory and field assembly work. Samples: Submit full width of panel, 24 long, indicating proposed panel profile. Additionally, submit representative concealed anchor clip and manufacturer s standard color chip for selected material type, color, gauge, texture and specified finish. Submit additional accessory items such as fasteners, closures, snow guards and other exposed panel accessories. DELIVERY, STORAGE AND HANDLING Deliver panels, coil, flashings and other components so that they will not be damaged or deformed. Package materials for protection against damage during transportation or handling. Exercise care in unloading, storing, and erecting panels and accessories to prevent bending, warping, twisting and surface damage. Stack materials on platforms or pallets, covered with tarpaulins or other suitable weather-tight and ventilated covering. Store materials to ensure dryness. Do not store panels in contact with other materials that might cause staining, denting or other surface damage. PROJECT CONDITIONS Field Measurements: Where possible, prior to fabrication of roof panels, flashings and trim, take field measurements of structure and substrate to receive panel system. Allow for trimming panels where final dimensions cannot be established prior to fabrication. WARRANTY Provide manufacturer s standard 35 year written warranty for Kynar finish. Provide two (2) year written warranty for workmanship and materials, signed by this section contractor, agreeing to repair or replace roof panel assembly that fails to remain weather tight. Repairs shall be made at no expense to the Owner. Warranty period shall commence upon substantial completion of the building. PART TWO PRODUCTS ACCEPTABLE MANUFACTURERS Coated Metals Group (CMG) CMG Ultra-Batten panels and system are specified for standard of quality. Equivalent products meeting or exceeding this standard may be accepted at the discretion of the General Contractor and Owner. All substitutions must be submitted in writing a minimum of two (2) weeks prior to the bid date. No substitutions which are not expressly accepted prior to the bid date shall be accepted. ROOFING SYSTEM CMG s Ultra-Batten concealed anchor, pre-formed, pre-finished standing seam roofing system. MATERIALS Steel: Hot-dipped zinc-coated steel sheet, ASTM A653, CS-Type B hot-dipped galvanized steel with a minimum yield strength of 40,000 psi. Steel shall be G90 galvanized, non-chemically treated, extra-smooth, minimum spangle, lock-forming quality.

Concealed Anchor Clips: 24ga. G90 galvanized one piece anchor clips. Approved clips shall be installed with two (2) fasteners each. Consult manufacturer for spacing requirements. Underlayment: 30lb. non-perforated, asphalt-saturated roofing felt. One ply, installed shingle fashion with 2 side laps and 6 end laps, stapled. Paper Slip Sheet: manufacturer. 5lb. rosin paper slip sheet or other material approved by metal roofing Accessories: Provide components required for a complete roofing system including, but not limited to, trim, fascia, drip edge, corners, J trim, Zee closure, hip and ridge flashing, valley metal, gable closure, base and counter flashing. Fabricated per CMG guidelines and details using same material, gauge and finish as roof panels. Gutters and Downspouts: Fabricate from same material gauge and finish as metal roof panels. Sealant: Sealant for concealed joints in sheet metal shall be one part, non-hardening, nonskinning, non-drying, non-migrating Urethane sealant equivalent to NP-1 as manufactured by Sonneborn. FINISHES General: Roof panels and sheet metal accessories exposed to view shall be coil coated with full strength, 70% Kynar 500 coating over a base coat of epoxy base primer. The dry-film thickness of the exterior coating shall be not less than.8 mil over a minimum.2 mil primer coat for a total dryfilm thickness of 1.0 mil. A.5 mil standard wash coat over primer shall be applied to the reverse side. Color shall be chosen from manufacturer s standard color chart. Acceptable Manufacturer: Ultra-Clad by Coated Metals Group (CMG). (800) 784-0356 Coating Durability: Provide manufacturer s coating which has been field tested under normal range of weathering conditions for a minimum of 35 years without peel, blister, flake, chip, crack or check in finish, and without chalking in excess of 8 (ASTM D 3361), and without fading in excess of 5 NBS units. Coating shall be protected promptly after application and cure by applying strippable film. FABRICATION General: Site fabricate roof panels to the greatest extent possible by manufacturer s specified procedures and processes, and as required to fulfill indicated performance requirements which have been demonstrated by factory testing. Comply with indicated profiles and dimensional requirements. Metal Gauges: Thicknesses required for structural performance, but not less than manufacturer s recommended minimums for profiles and applications indicated, and not less than 22 gauge (.030 ). Fabricate roof panels full length without joints and with nominal 16 spacing between standing seams.

Apply bituminous coating or other permanent separation materials on concealed panel surfaces where panels would otherwise be in direct contact with substrate materials which are noncompatible or could result in corrosion or deterioration of either material or finish. Trim, Flashings, Closures, Etc: Fabricate in longest lengths possible. Provide weather tight joints and allow for expansion. Form gutters and downspouts of profile and sizes indicated and as required in order to properly collect and remove water. Fabricate complete and required connection pieces. Form sections square, true and accurate in size, in maximum lengths possible and free from distortions and defects detrimental to appearance or performance. All exposed edges shall be hemmed. PART THREE EXECUTION INSPECTION Examine substrate and areas to which the roof panels are to be installed. Verify that dimensions are correct, adjacent or adjoining surfaces are dry, clean and reasonably smooth and free from defects, and there are no conditions that will adversely affect installation. Do not proceed with installation until unsatisfactory conditions have been corrected in an acceptable manner. INSTALLATION General: Comply with panel manufacturer s standard instructions and recommendations for the installation, as applicable to project conditions and supporting substrates. Anchor panels and other components of the work securely in place, with provisions for thermal or structural movement. Install underlayment and paper slip sheet under metal roofing, applied shingle fashion from eave to ridge. Roof panels shall be installed in continuous lengths, having no end laps, cross joints or transverse seams. Panels shall be attached to structure by means of concealed anchor clips. No through penetration of the roofing panels shall be permitted, except where approved by the manufacturer. Roofing anchor clips shall be spaced to meet design load requirements and approved engineering calculations. Secure panels without warp or deflection. Shim and align panel units within installed tolerance of ¼ in 20-0 on level, plumb and slope and within 1/8 offset of adjoining faces and of alignment of matching profiles. Install closures, gaskets, joint fillers and sealants where indicated and where required for weatherproof performance of panel system of types recommended by panel manufacturer. Flashing: Details in installation which are not indicated shall be in accordance with NRCA Construction Details, SMACNA Architectural Sheet Metal Manual, AA Specifications for Sheet Metal Work, panel manufacturer s printed instructions and details and the approved shop drawings. Installation shall provide for expansion and contraction of flashing details. Install work weather tight, plumb, level and true with components securely attached in accordance with manufacturer s instructions.

CLEANING AND PROTECTION Damaged Units: Replace panels and other components of the work which have been damaged or have deteriorated beyond successful repair by means of finish tough-up or similar minor repair procedure. Cleaning: Remove temporary protective coatings and strippable films as components are installed. Upon completion of panel installation, clean finished surfaces as recommended by panel manufacturer, and maintain clean condition during construction. END OF SECTION