Installing the Sno-free Standing Seam System for Metal Roofs



Similar documents
PANELIZED HOME INSTALLATION GUIDELINE

Window Installation Instructions

Residential Roofing Guide

Installation Manual for STANDING SEAM ROOFING

Snow/Ice Melt Heating Cable System Gutters & Roof Drains Installation Manual Nexans TXLP/1 Series Resistance Cables

IN-CARPET WIREWAY INSTALLATION GUIDE

PATHWAY Classic Series with Handrails Portable Wheelchair Ramp INSTRUCTIONS FOR USE 6428 REV A

RZ Guardrail System Installation Manual

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS

Screw Patterns Roof & Walls TR-36 MD-36 TSM-32. PBR-Panel

INSTALLATION OF A BAY WINDOW

Installation Guide MATTERHORN METAL ROOFING TO LAST A LIFETIME. MATTERHORN Standing Seam

AZEK Rail Install Guide

Installation Guide for Andersen Architectural Clad Outswing Commercial Doors

UNIT 4: SHEATHING AND SHINGLING THE ROOF

IMPORTANT INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION

Retractable Screen. Replacement Screen Instructions

How to Install UnderDeck The Original.

ILLUSION FRAMELESS SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

Sun Windows General Information Sun New Construction Window Installation Instructions

Destiny Shower Enclosure Installation Instructions

Tundra Series Windows January 2016

Installation Guide for Andersen Architectural Wood Inswing Entry Doors

Dell P Series Monitor VESA Mounting Bracket Installation Instructions

Grand Mesa Plus LAMINATE - WIRE BRUSHED. GAGVGM81012A Prairie. GAGVGM80012NA Colorado. GAGVGM84012A Pecan Rustic. GAGVGM85012A Saddle Walnut

VERSARAIL ALUMINUM STAIR RAILING INSTALLATION INSTRUCTIONS. Owner's Manual. Version. Models

Brick Veneer Construction

Air Conditioner Duct Construction & Repair

Basic Spring Motor Roller Shades

SLIDING PATIO DOOR INSTALLATION INSTRUCTIONS USING FRAME SCREWS

Vinyl Brick Mould Field Installation Instructions All Vinyl and Vinyl Clad Windows

RayClic Connection System Installation Instructions

Premier & Deluxe 3-Season Room Sliding Glass Door

Hollow or Cinder Block Wall Mount Job Aid

Repairing the Seam of the WaterRower Tank

By SP Partners, LLC. INSTALLATION GUIDE. Prestige

WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING

BRIDGE & SUPPLY COMPANY. Installation Guide. Ultra Includes:

Holiday Inn Express & Suites Covington (Newton County) 1. Standing-seam metal roofing, custom fabricated.

Plans will call for one of two soffit/fascia details:

Triple Threat 3-in-1 Game Table 3 IN 1 GAME TABLE

Minimizing Water Intrusion Through Roof Vents in High-Wind Regions

Mounting instructions for SOT78 (TO-220AB); SOT186A (TO-220F)

InsulView Window Installation Instructions

Installation Instructions

Classic Products, Inc. ClickLock Standing Seam Installation Manual

FRONT BUMPER INSTALLATION INSTRUCTIONS DODGE / MERCEDES SPRINTER

Directions For Applying Malarkey Laminate Shingles

RadianceRail Installation Guide

Arctic Leash Instruction Manual Alaskan Products Company LLC.

Composite Stone Veneer

HHS J.W. Peavy Center Exterior Walls Waterproofing and Roof Replacement Project WBS # H SECTION STANDING SEAM METAL ROOFING

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

Stainless Steel Sink Work Center With Portable Sink, Colander and Cutting Board

The existing roof angle change terminations and flashings when sound and intact can be reused.

Cable Support System Guide for Andersen Bow, Bay, and Box Projecting Window Units

INSTALLATION MANUAL For Grand Rib-3 / Multi Purpose / & Classic Rib Roofing Panels

Installation Instructions S

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

BUILD A CARPORT. 2 - Planning the carport. 3 - Designing the carport

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)

Table of Contents WARNING SYMBOLS AND DEFINITIONS

Acrylic Walls Installation Instructions

Discount Direct Metal Roofing Plus Rib Roofing Panels Installation Instructions

apple Service Source PowerBook G4 (DVI) Updated 4 December Apple Computer, Inc. All rights reserved.

Expanding a 40-Type Cabinet

Gerard Installation Manual Shingle Profiles

INSTALLATION INSTRUCTIONS for Vinyl Windows without Nailing Fin (JII011) ImPOrTANT INFOrmATION & GlOssAry. rough OPeNINGs

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood

MODEL G300 BRAKE BLEEDER

Stair Railing. Installation Guide

AZEK Rail Install Guide

The Butler MR-24 Standing Seam Roof Difference. A comparison between metal roof systems

StuccoSpec Moisture Testing Inspection

General Instructions and Guidelines

ECM-D70T / ECM-D70T1.5

INSTALLATION INSTRUCTION - INSTRUCCIONES DE INSTALACION FOR DOUBLE-HUNG VENT REPLACEMENT WINDOW

DVD-60C The Seven Sins of Wire Harness Assembly

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Calvert USA, Inc. Attic Stairs

Installation Instructions

INSTALLATION INSTRUCTIONS IMPERVIA (Vent and Fixed) AWNING, CASEMENT, and LARGE AWNING WINDOW WITH FINS

IMPORTANT! READ ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION. Step 1:

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

Speed-Mat Rectangle Cutter

Infant Car Seat Adapter Instructions

CordlessPleated FabricShade including Top-Down/Bottom-Up. owner's handbook

Retail Reception kiosk

CB-100 CB-150 CS-100 SL-100 SL-150 SLZ-1000

INSTALLATION INSTRUCTIONS PART NUMBER:

Retardants Inc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

GYPSUM AREA SEPARATION FIREWALLS GA

IN00419 (rev A) Aqua 6 Glide Quadrant and Off-set Quadrant Enclosure

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

METAL ROOFING INSTALLATION GUIDE

SHUTTER INSTALLATION INSTRUCTIONS. AUGUST 2006 Version 2

AIR CONDITIONER & HEAT PUMP DIGITAL CONTROL FOR DUCTED SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS

INFRARED QUARTZ WALL HEATER

RayClic Connection System Installation Instructions

Transcription:

Installing the Sno-free Standing Seam System for Metal Roofs SFP SSP CLIP SSP STANDING SEAM SFP EXTRUSION SFP RAMP PANEL Step # 1 Mark the location and Install Extrusion Mark the area on the roof to receive the extrusions. Make certain that the extrusion is square between the ribs. This measurement will vary upon the size panel system that you order. Apply a generous amount of primer (not supplied) to the surface of the roof and the underside of the extrusion to confirm the best possible adhesion. Apply metal bonding sealant to the roof where the extrusion will be installed to ensure proper adhesion of the extrusion to the roof. NOTE: Cutting the extrusion may be needed depending on the desired length. Step # 2 Install SSP Panel onto the Extrusion Install heating cable or tubing according to specifications and design. Snap the panel onto the extrusion with downward pressure. Ensure that the tail flange of the panel fits over or snug against the rib of the metal roof. (Each panel will vary depending on the roof type. The installer must use his/her best judgment on the installation of the panel.) Remove all plastic from the metal prior to the next step. Step # 3 Install the SSP-Clip Properly measure and mark the location of the Ramp Clip above the finished section of the SSP Panel. Remove the plastic on the metal prior to adhesion. Properly adhere the clip to the metal roof using the correct primer and adhesive. If screws are used, properly seal all penetrations. NOTE: For added protection, we recommend a bead of sealant along the back of the clip to direct water to either side of the clip. 1

Installing the Sno-free Standing Seam System for Metal Roofs Step # 4 Attach the Ramp Insert the tab on the ramp into the recently installed clip. Apply sealant inside the clip in order to hold the ramp securely. Apply a generous amount of sealant on the bottom of the ramp where it will meet with the extrusion and the SSP Panel. Put downward pressure to snap the ramp over the extrusion and the SSP Panel. Remove all protective plastic on metal prior to the next step. Step # 5 Install Clamps Firmly attach the panel to the rib of the standing seam roof. Use non-penetrating clamps that are designed to work with the type of seam that is associated with your standing seam roof. If penetrations are made with screws or rivets due to a lack of usable clamps, seal all penetrations properly. Step # 6 Finalize the system Install adequate quantities of clamps on all panels. Leave a 1 Excess of SSP panel overhanging the extrusion to cut and bend down to cover the end of the extrusion. Any areas where the wire enters and exits the panel should have a generous amount of sealant placed to protect the jacket of the heating cable from any sharp edges of the metal. If there is no excess available to fabricate an end seal, Contact Heat Trace Specialists for Expansion Joints to cut and fabricate end seals on site. 2

Installing the Sno-free Standing Seam System for SnapLock Metal Roofs SSP STANDING SEAM PANEL SFP EXTRUSION SFP RAMP Step # 1 Mark the location and Install Extrusion Mark the area on the roof to receive the extrusions. Make certain that the extrusion is square between the ribs. This measurement will vary upon the size panel system that you order. Apply a generous amount of primer (not supplied) to the surface of the roof and the underside of the extrusion to confirm the best possible adhesion. Apply metal bonding sealant to the roof where the extrusion will be installed to ensure proper adhesion of the extrusion to the roof. NOTE: Cutting the extrusion may be needed depending on the desired length. Step # 2 Install SSP Panel onto the Extrusion Install heating cable or tubing according to specifications and design. Snap the panel onto the extrusion with downward pressure. Ensure that the tail flange of the panel fits over or snug against the rib of the metal roof. (Each panel will vary depending on the roof type. The installer must use his/her best judgment on the installation of the panel.) Remove all plastic from the metal prior to the next step. Step # 3 Attach the SSP Panel onto the Roof Properly measure and mark the location where each attachment screw will be located. Pre-drill each hole to ensure the screw will enter straight through the top of the existing rib. NOTE: For added moisture protection, we recommend a sealant injected into the pre-drilled hole before the screw is inserted. 3

Installing the Sno-free Standing Seam System for SnapLock Metal Roofs Step # 4 Ensure proper screw penetration As described in the picture to the right, confirm the screw has penetrated the top of the rib without being inserted on an angle and penetrating the cavity of the existing metal roof. We suggest using a minimum 1 1/2 Self-piercing screw with neoprene washer in order to firmly attach into the roof deck. Length of screw will be determined by the height of the rib. Step # 5 Install remaining screws and panels Once each panel is firmly attached, ensure the cable is properly protected and secured wherever it is outside of the extrusion. Where two panels meet, we recommend overlapping the panels for proper water drainage. Use the SFP-4V-E-XJ Expansion joint cover over the extrusion portion of the panel and firmly secure with sealant. OPTIONAL PRODUCT If the SSP panels are being installed on only a portion of the roofing surface then we suggest to use our SSP-RAMP. For more information on installing this Ramp: Refer to the installation manual on the section Installing the Sno-Free Standing Seam System for Metal Roofs on Diagram #3 and #4. End Cap installation A simple relief cut on the sides of the panel or expansion joint and bend on the bottom of the panel can easily protect the look of the finished product. If the cable is making its entry at the bottom as shown in the diagrams, then secure the loose cable with our Belt Loop Clips along the drip edge or fascia. If the cable is making its entry at the top, then cut the extrusion short from the Drip edge, Make the loop in the cable leaving enough space for the panel to cover the extrusion and the looped cable within the finished end cap. Leave sufficient space between the cable and any sheet metal edges to ensure protection of the cable. 4

Tools Needed: 1) Radial arm saw or chop saw to cut the aluminum extrusions. A 100 tooth carbide tipped saw blade is suggested. 2) Metal shears or tin-snips. 3) Use the appropriate metal cutting blade to trim the cladding (sheet metal) as needed. 4) Hand and/ or powered screwdriver(s) with the appropriate tip(s) for the attachment screws to be used. All screws should be the flush head type (Pan Headed) for best results. 5) A folding bar to create or modify any bends. 6) Safety Glasses and/or any other safety equipment needed. 7) Use all ladders in a safe & responsible manner and avoid overhead power lines. LEGAL DISCLAIMER: This installation manual shows the best known method of installation at the time of the writing of this document. Heat Trace Specialists recommends all parties that install these systems to use their best judgment on common roofing and sheet metal installation methods. We only guarantee the product material supplied by Heat Trace Specialists. Heat Trace Specialists designed this system for certified and qualified contractors and any other licensed construction professionals. Any professional installer of these products understands that any property damage from water that entered through any penetration from the system will not hold Heat Trace Specialists or any affiliate liable for expenses or damages. All penetrations into the deck of the roof must be properly sealed and covered. All installers of Heat Trace Specialists products are legally required to install all products according to local, state and federal laws and codes. While installing Heat Trace Specialists products use all protective gear and proper tools that are recommended in electrical installation and in the construction industry. Heat Trace Specialists is not liable for any product that is installed incorrectly or damaged during the installation process. Because roofs and buildings are all different, Heat Trace Specialists recommends you use your best judgment when installing our products to achieve the best possible results for appearance, safety, and effective operation. Heat Trace Specialists does not offer instructions for every aspect of the installation process, we only offer the basics and we rely on the common knowledge and ability of the final installer to find the proper method of installation within their own industry and according to their local codes. Any installer should be trained in working with sheet metal and capable of finishing all parts and connections with the best of their ability and workmanship capabilities. Heat Trace Specialists does not warranty any workmanship of said installers and hereby is exempt from all liability. If any panel is being installed in an area with high winds. A few self-tapping screws can be installed on the nose of the system per section and end caps to ensure minimal damage does occur. Heat Trace Specialists products must be installed, operated and maintained in accordance with Heat Trace Specialists instructions. Heat Trace Specialists is not liable for damage or unsatisfactory performance of products resulting from accident, negligence, alteration, unauthorized repair, improper application or installation of the products. Heat Trace Specialists is not liable for any incidental or consequential damages. SELLER WILL IN NO EVENT BE LIABLE FOR ANY DIRECT, INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES WHATSOEVER, INCLUDING BUT NOT LIMITED TO LOSS OF USE OF PURCHASER S FACILITIES, LOSS OF REVENUE, LOSS OF PROFITS AND CLAIMS OF ANY CUSTOMERS OF PURCHASER, AND SELLERS LIABILITY UNDER NO CIRCUMSTANCES WILL EXCEED THE CONTRACT PRICE FOR THE GOODS FOR WHICH LIABILITY IS CLAIMED. 5