BLACK TIE. Instructions Manual

Similar documents
IH E Sigma Island 90

Cooktop Low-Profile Ventilation Hoods

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Portable Air Conditioner

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

LUCCI AIRFUSION QUEST II CEILING FAN

IMPORTANT INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Important Safeguards

- 2 - IMPORTANT SAFETY REMINDERS

Installation Instructions

Contact Details. Please note that some of the contact details on this PDF document may not be current.

3 IN 1 BATHROOM HEATER

ES Manual de instalación, uso y mantenimiento de campanas decorativas Handbuch zu Installation, Bedienung und Wartung von dekorativen Abzugshauben

2-SLICE COOL TOUCH TOASTER

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS

VACUUM CLEANER INSTRUCTION MANUAL

MIC-WKT and MIC-WKT-IR

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

Thank You... On behalf of the entire team at Thane Housewares, we appreciate your recent purchase

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Stove Guard Kit User Manual

DIMENSION ELECTRIC RANGE

Operating Instructions Bedienungsanleitung Mode d emploi

How To Program An Autodialer

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

Operating Instructions Air Conditioner

INFRARED QUARTZ WALL HEATER

MAINTENANCE & TROUBLESHOOTING

IMPORTANT SAFETY INFORMATION

Quadrant Shower Enclosure. Telephone Cleaning. All chrome surfaces should be cleaned using a clean damp cloth.

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE!

Daily use. Never use alcohol or other solvents to clean any part of the loudspeakers!

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

IMPORTANT SAFETY INFORMATION

DMSG_0152_0112_V4 Mamas & Papas (Holdings) Ltd Dream Swing - 1 -

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Installation Instructions

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

Name Of Occupancy Date. Yes No Describe

Instruction manual for Firstline FCS12000CH

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

PORTABLE AIR CONDITIONER

INSTALLATION & USER INSTRUCTIONS WALL MOUNTED LCD ELECTRIC FIRE

Flue Installation. High Efficiency Condensing Boilers

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Oil - kerosene burners

GENUINE PARTS INSTALLATION INSTRUCTIONS

PROFESSIONAL POPCORN MAKER

INSTALLATION & USER INSTRUCTIONS

Digital Fingerprint safe

Use and Care Manual. Model CPA12KH AIR CONDITIONER

Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) (ROI) Vax model number: Version 1.0

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

FLEXIT S4 R S6 R S7 R

INSTALLATION INSTRUCTIONS

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Convection TCO650. For your safety and continued enjoyment of this product, always read the instruction book carefully before using.

Operating Manual Remote Cost Control Monitor

430 Power/Electronics Replacement

MAINTENANCE & TROUBLESHOOTING

EVOKE LCD ELECTRIC WALL HEATER MODEL : L23LCD INSTALLATION AND USER INSTRUCTIONS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

AZB 800. Vertical Flue Gas Ducting Ø60/100mm

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

PORTABLE AIR CONDITIONER (LOCAL)


Installation Instructions for Alarm Module Kit A043F059

Telis 4 Soliris RTS Operating and installation guide Ref A

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book

Light Source User Guide

Meaco 30L and Meaco 40L dehumidifier instruction manual

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

4.3-inch Back-Up Camera

INSTRUCTION FOR THE USER

GNOME PELLET E.I. Pellet Heater Owner's Manual Installation and Operating Instructions. Please read this entire manual before installation.

Convection TCO600. For your safety and continued enjoyment of this product, always read the instruction book carefully before using.

How To Use A Power Supply On A Powerline 2.2 (Ai)

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

S5 EK S5 EP MANUAL FOR USE AND MAINTENANCE. La Spaziale S.p.A.

GREENSTAR 60/100 HORIZONTAL FLUE

AutoDome Easy II. VEZ Series. Mounting Manual

Manual for Fire Suppression & Methane Detection System

- mark gas burners Cuenotherm NC.4 - NC.6 - NC kW.

Installation, operation and maintenance manual TX 35A

OWNER S MANUAL DRAINVAC ATOMIK PRINTED APRIL

Transcription:

BLACK TIE EN Instructions Manual

RECOMMENDATIONS AND SUGGESTIONS The Instructions for Use apply to several versions of this appliance. Accordingly, you may find descriptions of individual features that do not apply to your specific appliance. INSTALLATION The manufacturer will not be held liable for any damages resulting from incorrect or improper installation. The minimum safety distance between the cooker top and the extractor hood is 650 mm (some models can be installed at a lower height, please refer to the paragraphs on working dimensions and installation). Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the hood. For Class I appliances, check that the domestic power supply guarantees adequate earthing. Connect the extractor to the exhaust flue through a pipe of minimum diameter 120 mm. The route of the flue must be as short as possible. Do not connect the extractor hood to exhaust ducts carrying combustion fumes (boilers, fireplaces, etc.). If the extractor is used in conjunction with non-electrical appliances (e.g. gas burning appliances), a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas. The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air. When the cooker hood is used in conjunction with appliances supplied with energy other than electric, the negative pressure in the room must not exceed 0,04 mbar to prevent fumes being drawn back into the room by the cooker hood. In the event of damage to the power cable, it must be replaced by the manufacturer or by the technical service department, in order to prevent any risks. USE The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells. Never use the hood for purposes other than for which it has been designed. Never leave high naked flames under the hood when it is in operation. Adjust the flame intensity to direct it onto the bottom of the pan only, making sure that it does not engulf the sides. Deep fat fryers must be continuously monitored during use: overheated oil can burst into flames. Do not flambè under the range hood; risk of fire This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. CAUTION: Accessible parts may become hot when used with cooking appliances.. MAINTENANCE Switch off or unplug the appliance from the mains supply before carrying out any maintenance work. Clean and/or replace the Filters after the specified time period (Fire hazard). Clean the hood using a damp cloth and a neutral liquid detergent. 2 The symbol on the product or on its packaging indicates that this product may not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. For more detailed information about recycling of this product, please contact your local city office, your household waste disposal service or the shop where you purchased the product. EN 3

CHARACTERISTICS Components Ref. Q.ty Product Components 1 1 Hood Body, complete with: Controls, Light, Blower, Filters 2.1 1 Upper Section 2.2 1 Lower Section 8 1 Directional Air Outlet grille 9 1 Flange 15 1 Angle iron 16 1 Filter cover Ref. Q.ty Installation Components 7.2.1 2 Upper Chimney Section Fixing Brackets 11 6 Wall Plugs 11a 2 Wall Plugs SB 12/10 12a 6 Screws 4,2 x 44,4 12c 10 Screws 2,9 x 6,5 12d 6 Screws 2,9 x 9,5 Q.ty Documentation 1 Instruction Manual EN 4

Dimensions 330 Min. 330 - Max. 650 EN 5

INSTALLATION Wall drilling and bracket fixing 1 2 7.2.1 164 164 11a 1 1 12a 11 140 140 2 2 540 X 788 450 As a first step, proceed with the following drawings: a vertical line up to the ceiling or up to the upper limit, at the centre of the area in which the hood is to be fitted; a horizontal line at a minimum 788 mm above the cooker top. Mark a point (1) on the horizontal line, 164 mm to the right of the vertical reference line. Repeat this operation on the other side, checking that the two marks are levelled. Mark a reference point (2) as indicated at 140 mm from the vertical reference line and 540 mm above the cooker top. Repeat this operation on the other side, checking that the two marks are levelled. Drill at the marked points (1), using a ø 12 mm drill bit. Drill at the marked points (2) using a ø 8 mm drill bit. Insert the bracket plugs 11a into the holes (1) and tighten the screws. Insert plug 11 into holes (2). To install a decorative chimney ( optional ) Place bracket 7.2.1 on the wall, about 1-2 mm from the ceiling or from the upper limit, aligning the centre (notch) with the vertical reference line. Mark the wall at the centres of the bracket holes. Place the bracket 7.2.1 on the wall at X mm below the first bracket (X = height of the upper chimney section), aligning the centre (notch) with the vertical line. Mark the wall at the centres of the bracket holes. Drill ø 8 mm holes at all the marked centre points. Insert the wall plugs 11 in the holes. Fix the brackets using the 12a screws (4,2 x 44,4) supplied with the hood. EN 6

Fitting the hood body Open the doors/the door (See section Open Panels). Remove the Metal grease filters using the handles provided. Adjust the two screws Vr, in the brackets 11a, so that they are at the start of their travel. Hook the hood body to the two brackets 11a. From the inside of the hood body, turn screws Vr to level the hood body itself. Fasten the safety screw 12a. Close the doors/the door again. 12a Vr 11a Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe ø 150 or 120 mm, the choice of which is left to the installer. To install a ø 120 mm air exhaust connection, insert the reducer flange 9 on the hood body outlet. Fix the pipe in position using sufficient pipe clamps (not supplied). Remove possible charcoal filters. ø 150 9 ø 120 RECIRCULATION VERSION AIR OUTLET To install the Recirculation Version of the hood, the optional Activated charcoal cartridge kit must be purchased. Screw the filter cover onto the air outlet, using four screws 12c (2.9 x 12.5). Fix the directional grille 8 on the recirculation air outlet using the 2 screws 12d (2,9 x 9,5) provided. 16 8 12d 12c EN 7

ELECTRICAL CONNECTION Connect the hood to the mains through a two-pole switch having a contact gap of at least 3 mm. Remove the grease filters (see paragraph Maintenance) being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan. Flue assembly The chimney can only be installed with exhausting hood Fasten the angle iron 15 to the hood canopy using the screws 12d (2,9 x 9,5) provided. Upper exhaust flue Slightly widen the two sides of the upper flue and hook them behind the brackets 7.2.1, making sure that they are well seated. Secure the sides to the brackets using the 4 screws 12c (2,9 x 6,5) supplied. Lower exhaust flue Slightly widen the two sides of the flue and hook them between the upper flue and the wall, making sure that they are well seated. Fix the lower part laterally to the hood body using the 2 screws 12c (2,9 x 6,5) supplied. 2 2.1 2.2 7.2.1 12c 12c Screen Opening Before carrying out any Use and Maintenance operations, open the Screen. EN 8

USE Control panel Button Function Led A Motor off. The Leds indicating the Speed of the motor turn off. Enables / Disables Keyboard Lock mode if pressed All the Leds light up in cycle and run a start-up sequence. and held for 5 seconds. B Activates speed one. The Leds indicating Speed one and Motor Off turn on. C Activates speed two. The Leds indicating Speed two and Motor Off turn on. D Activates speed three. The Leds indicating Speed three and Motor Off turn on. Press and hold the button for approximately 5 seconds, with all the loads turned off (Motor and Lights), to turn the Activated Charcoal Filter alarm on. To turn it off, press and hold the button again for 5 seconds. Button A LED flashes twice. Button A LED flashes once. E Activates speed four. The Leds indicating Speed four and Motor Off turn on. Press and hold for 5 sec. to activate Intensive speed. This speed is timed to run for 10 minutes. At the end of this time the system will return to the speed set previously. It is disabled by pressing the Button or turning the Motor off. The Led flashes once a second and button A Led lights up. F Starts the 24H function, in which the motor starts at a speed that allows suction of 100 m3/h for 10 minutes per hour. This mode cannot be activated if Intensive or Delay modes are active. To deactivate it, press the same button or button A. When the filters alarm is triggered, the alarm can be reset by pressing and holding this button for approximately 5 seconds. These indications are only visible when the motor is turned off. G Activates Delay mode, causing automatic shutdown of the Motor and the Lighting system with a 20 delay. It is disabled by pressing the button or turning the motor off. H Pressing and holding the button for 5 seconds enables the remote control. Pressing and holding the button for 5 seconds disables the remote control Press briefly to turn the lighting system on and off at maximum intensity. Press and hold the button for 2 seconds to turn the Courtesy Lights On (if provided). The Leds indicating 24H speed and Motor Off turn on. The button A Led flashes three times The Delay and Motor Off button Leds turn on. Delay Led Flashing: Indicates the need to wash the metal grease filters. The alarm is triggered after the Hood has been in operation for 100 working hours. Delay Led Flashing: Indicates the need to change the activated charcoal filters, and also to wash the metal grease filters. The alarm is triggered after the Hood has been in operation for 200 working hours. Button A Led flashes twice. Button A Led flashes once. The Led on the button lights up. The Led on the button lights up. EN 9

REMOTE CONTROL (OPTIONAL) The appliance can be controlled using a remote control powered by a 1.5 V carbon-zinc alkaline batteries of the standard LR03- AAA type (not included). Do not place the remote control near to heat sources. Used batteries must be disposed of in the proper manner. Opening Panel Open the Panel by pulling it. Clean the outside with a damp cloth and neutral detergent. Clean the inside using a damp cloth and neutral detergent; do not use wet cloths or sponges, or jets of water; do not use abrasive substances. EN 1 10

MAINTENANCE Metal grease filters These can also be washed in the dishwasher, and need to be cleaned whenever the Delay Led comes on or at least once every 2 months use, or more frequently if use is particularly intensive. Resetting the alarm signal Turn the Lights and the Suction Motor off. Press and hold button (24H) for 5 seconds. Cleaning the Filters Remove the Filters one at a time, pushing them towards the back of the unit and at the same time pulling downward. Wash the Filters without bending them, and leave them to dry completely before replacing. (If the surface of the filter changes colour as time goes by, this will have absolutely no effect on the efficiency of the filter itself.) Replace, taking care to ensure that the handle faces forwards. EN 1 11

Activated Charcoal Filter (Recirculation Version) The Activated Charcoal Filter is only present on the Hoods in Recirculation version, and has the job of retaining smells in the flow of air that passes over it, until reaching saturation. This cannot be washed or regenerated, and must be changed when the Delay led on the display starts to flash, or at least once every 4 months. The Alarm signal, if it has been activated, only appears when the Suction motor is turned on. Activating the alarm signal In Recirculation Version Hoods, the Filter Saturation Alarm must be activated on installation or at a later date. Turn the Lights and the Suction Motor off. Press button D until confirmation is given: Motor Off Leds flash twice Activated Charcoal Filter saturation alarm ACTIVATED. Motor Off Leds flash once Activated Charcoal Filter saturation alarm DEACTIVATED. CHANGING THE ACTIVATED CHARCOAL FILTER Resetting the alarm signal Turn the Lights and the Suction Motor off. Press and hold button F (24H) for 5 seconds. Changing the Filter Remove the Metal grease filters. Remove the saturated Activated charcoal filter, using the hooks provided. Fit the new Filter, hooking it into place. Replace the Metal grease filters. B A Lighting unit Warning: This appliance is fitted with a white LED lamp classed as 1M according to EN 60825-1: 1994 + A1:2002 + A2:2001 standards; maximum optical power emitted @439nm: 7µW. Do not look directly at the light through optical devices (binoculars, magnifying glasses ). For replacement contact technical support. ("To purchase contact technical support") EN 1 12

LEKS GROUP BG София: 02/963 33 20, 963 33 80, ж.к. Сухата Река, бл. 49, Пловдив: тел.: 032/633 778, ул. Цар Асен 30, Варна: тел.: 052/504 634, бул. Вл. Варненчик 277, Бургас: тел.: 056/841 475, ул. Фердинандова 77 Русе: тел.: 082/872 717, ул. Борисова 84, Плевен: тел.: 064/833 172,ул. Данаил Попов 4, Велико Търново: тел.: 062/603 883,бул. България 26, Благоевград: тел.: 073/832 782, к-с Парангалица, Видин: тел.: 094/600 209, ул. Цар Александър II, к-с Съединение, бл. 12