GREENSTAR 60/100 HORIZONTAL FLUE
|
|
|
- Bathsheba King
- 9 years ago
- Views:
Transcription
1 FLUE KIT INSTALLATION MANUAL ROOM SEALED TELESCOPIC FLUE ROOM SEALED LONGER TELESCOPIC FLUE PLUME MANAGEMENT SYSTEM GREENSTAR 60/00 HORIZONTAL FLUE FOR WORCESTER GREENSTAR CDi WALL HUNG, Si, i JUNIOR, i SYSTEM & Ri SERIES OF GAS APPLIANCES INCLUDING BRITISH GAS VARIANTS b (00/) Wo
2 CONTENTS CONTENTS KEY TO SYMBOLS AND SAFETY PRECAUTIONS Explanation of symbols Safety precautions PRODUCT INFORMATION Telescopic flue components Flue extension components PRE-INSTALLATION Flue terminal positions Flue measuring and cutting Flue extension example Flue length guide INSTALLATION Telescopic flue installation Installing the telescopic flue: Installing a high level telescopic flue: Flue terminal plume re-direction Extended flue installation PRODUCT INFORMATION Plume management system components 6 PRE-INSTALLATION Plume management terminal positions Plume management options & measurement Determine the plume management system length Measuring for a plume management system INSTALLATION Standard plume management installation 9 7. Extended plume management installation 0 7. Redirecting the flue discharge Extended plume management installation for a balcony / overhang SERVICE AND SPARES Servicing and maintenance Spare parts b (00/)
3 KEY TO SYMBOLS AND SAFETY PRECAUTIONS KEY TO SYMBOLS AND SAFETY PRECAUTIONS EXPLANATION OF SYMBOLS WARNING SYMBOLS Safety instructions in this document are framed and identified by a warning triangle which is printed on a grey background. SYMBOLS Cutting required Electrical hazards are identified by a lightning symbol surrounded by a warning triangle. Cutting not required Signal words indicate the seriousness of the hazard in terms of the consequences of not following the safety instructions. NOTICE indicates possible damage to property or equipment, but where there is no risk of injury. CAUTION indicates possible injury. WARNING indicates possible severe injury. DANGER indicates possible risk to life. IMPORTANT INFORMATION Notes contain important information in cases where there is no risk of personal injury or material losses and are identified by the symbol shown on the left. They are bordered by horizontal lines above and below the text. ADDITIONAL SYMBOLS Table Symbols Symbol B Meaning a step in an action sequence a reference to a related part in the document or to other related documents a list entry a list entry (second level) Table Documentation symbols ABBREVIATIONS Ø RS Table Diameter Room Sealed Abbreviations b (00/)
4 KEY TO SYMBOLS AND SAFETY PRECAUTIONS SAFETY PRECAUTIONS IF YOU SMELL GAS: B CALL NATIONAL GAS EMERGENCY SERVICE ON B DO NOT TURN ELECTRICAL SWITCHES ON OR OFF B DO NOT STRIKE MATCHES OR SMOKE B KEEP PEOPLE AWAY FROM THE AFFECTED AREA B PUT OUT NAKED FLAMES B OPEN DOORS AND WINDOWS B TURN OFF THE CONTROL VALVE AT THE METER Flue systems must not be modified in any way other than as described in the fitting instructions. Any misuse or unauthorised modifications to the appliance, flue or associated components and systems could invalidate the warranty. The manufacturer accepts no liability arising from any such actions, excluding statutory rights. SERVICING Advise the user to have the system serviced annually by a competent, qualified Gas Safe registered engineer. Approved spares must be used to help maintain the economy, safety and reliability of the appliance. IMPORTANT: The service engineer must complete the Service Record on the Benchmark Checklist after each service. Benchmark places responsibilities on both manufacturers and installers. The purpose is to ensure that customers are provided with the correct equipment for their needs, that it is installed, commissioned and serviced in accordance with the manufacturer's instructions by competent persons and that it meets the requirements of the appropriate Building Regulations. The Benchmark Checklist can be used to demonstrate compliance with Building Regulations and should be provided to the customer for future reference. Installers are required to carry out installation, commissioning and servicing work in accordance with the Benchmark Code of Practice which is available from the Heating and Hotwater Industry Council who manage and promote the scheme. Visit centralheating.co.uk for more information. HEALTH AND SAFETY The appliance contains no asbestos and no substances have been used in the construction process that contravene the COSHH Regulations (Control of Substances Hazardous to Health Regulations 988). COMBUSTION AND CORROSIVE MATERIALS Do not store or use any combustible materials (paper, thinners, paints etc.) inside or within the vicinity of the appliance. Chemically aggressive substances can corrode the appliance and invalidate any warranty. FITTING AND MODIFICATIONS Fitting the appliance and any controls to the appliance may only be carried out by a competent engineer in accordance with the current Gas Safety (Installation and Use) Regulations. INSTALLATION REGULATIONS Current Gas Safety (Installation & Use) Regulations: All gas appliances must be installed by a competent person in accordance with the above regulations. Failure to install appliances correctly could lead to prosecution. The appliance must be installed in accordance with, and comply to, the current: Gas Safety Regulations, IEE Regulations, Building Regulations, Building Standards (Scotland) (Consolidation), Building Regulations (Northern Ireland), local water by-laws, Health & Safety Document 65 (The Electricity at Work Regulations 989) and any other local requirements. British Standards: The relevant British Standards should be followed, including: BS50: BS50: BS6798: Flues and ventilation for gas appliances of rated heating not exceeding 70kW (net): Flues Flues and ventilation for gas appliances of rated heating not exceeding 70kW (net): Air Supply Installation of gas fired boilers of rated input up to 70kW (net) Where no specific instruction is given, reference should be made to the relevant British Standard codes of Practice. Timber framed building: Where the boiler is to be fitted to a timber framed building the guidelines laid down in BS50: Part and IGE "Gas Installations in Timber Frame Buildings should be followed b (00/)
5 PRODUCT INFORMATION PRODUCT INFORMATION TELESCOPIC FLUE COMPONENTS FLUE EXTENSION COMPONENTS 60/00 mm TELESCOPIC FLUE KIT: 60/00mm - 0mm Part No.: /00 mm LONGER TELESCOPIC FLUE KIT: Part No.: /00mm - 000mm TELESCOPIC FLUE ASSEMBLY WALL INNER SEAL WALL OUTER SEAL INSTALLATION MANUAL 5 ALUMINIUM TAPE 6 ACCESSORY PACK Table 7 Part No.: bend assembly plus: grease pack two No. 8 screws & grease sachet 60/00mm Support bracket kit: Part No.: bend x plus: grease pack two No. 8 screws & grease sachet 60/00mm 90 bend: 6 Part No.: Flue connector, vertical plus: Screw pack 60/00mm 5 bend: 5 Part No.: Extension tube assembly plus: grease pack two No. 8 screws & grease sachet 60/00 High level horizontal flue adapter Part No.: Extension tube assembly plus: grease pack two No. 8 screws & grease sachet 60/00mm - 000mm Telescopic flue components Part No.: Extension tube assembly plus: grease pack two No. 8 screws & grease sachet Part No.: Wall bracket, swivel bracket, clamp, fixing screws and wall plugs (6 in kit) Table 5 Flue extension components Wo 5 Telescopic flue components Wo Fig. Fig b (00/) Flue extension components 5
6 PRE-INSTALLATION PRE-INSTALLATION FLUE TERMINAL POSITIONS All measurements in millimetres Velux Window Dormer Window 7, Drainpipe 5 00,500 00, Boundary 600 Window Wo Fig. Flue terminal positions NOTE: B All measurements are the minimum clearances required. B Terminals must be positioned so to avoid combustion products entering the building. B Support the flue at approximately one metre intervals and at a change of direction, use suitable brackets and fittings (Flue bracket part numbers.: 00mm Key to illustration Flue clearance must be at least 00mm from the ground. Terminal guards must be fitted if the flue is less than metres from the ground or if a person could come into contact with the flue terminal. 600mm distance to a boundary, unless it will cause a nuisance. BS 50: Part recommends that care is taken when siting terminals in relation to boundaries. 600mm minimum clearance from a skylight to a vertical flue.. Vertical flue clearance, 500mm to non-combustible building material, and,500mm clearance to combustible building material. 5. The dimension below eaves, gutters, pipes and drains can be reduced to 5mm, as long as the flue terminal is extended to clear any overhang. Any external flue joints must be sealed with a suitable silicon sealant mm clearance to any vertical structure on a roof, 600mm to room sealed flue or,500mm to an open flue. 7.,500mm between a vertical flue terminal and a window or dormer window mm from a pitched roof or in regions with heavy snow fall 500mm. 9. The flue cannot be lower than,000mm from the top of a light well due to the build up of combustion products. 0.,000mm below a Velux window, 600mm above or to either side of the Velux window. 00mm below eaves and 75 mm below gutters, pipes and drains.,00mm between terminals facing each other. 00mm to an internal or external corner. Installations in car ports are not recommended.. The dimension below eaves, balconies and car ports can be reduced to 5 mm, as long as the flue terminal is extended to clear any overhang. Any external flue joints must be sealed with suitable silicon sealant mm above, below and either side of an opening door, air vent or opening window b (00/)
7 PRE-INSTALLATION FLUE SYSTEMS IN VOIDS When installing a new flue system consider the following information. CAUTION: Flue systems in ceilings or roof voids. Where a flue system is not going to be accessible, provision for access must be made for service and inspection: B Voids containing concealed flues must have at least one inspection hatch no less than 00mm square. B Flue joints within the void must not be more than 5m from the edge of the inspection hatch. B Inspection hatches should be located at changes of flue direction. B If this is not possible, bends should be viewable from both directions. FLUE SYSTEMS IN CEILINGS OR ROOF VOIDS When installing a flue system in a ceiling or roof void, the following points must be observed: Access points for inspection of the flue system must be sufficiently sized for visual inspection, particularly at any joint in the flue system. The flue system must not pass through a neighbouring property, as access may not be possible at the time of inspection. Any access must not contravene any other building regulations or fire regulations. Refer to Building Regulations Approved Documents B, L and E.. The access panels must be no less than 00mm square. Larger access panels can be considered if the whole flue system needs to be viewed. 5. The flue system must be adequately supported at regular interval, approximately every 5 metres. Fig. Flues in voids X This dimension must not be more than 5 metres Inspection hatch Flue terminal Concealed flue connection External wall 5 Internal wall Boiler 6 X X 5 5 X X 7 Boiler 6 Any intervening joints must be visible within 5 metres of the inspection hatch X X Wo 7 Accessible flue connection Table 6 ANNUAL INSPECTION When the flue system is inspected under the annual service, the engineer must inspect and confirm that: B the flue system is continuous without any breaks. B all joints in the flue system are sound and correctly assembled according to the manufacturers instructions. B the flue has a fall of (5 millimetres per metre) back to the boiler b (00/) 7
8 PRE-INSTALLATION FLUE MEASURING AND CUTTING NOTE: FLUE LENGTH B Do not exceed the maximum straight length for a horizontal 60/00mm flue or a 60mm plume management system (if used) as stated in the relevant Installation, Commissioning & Servicing Instructions manual or addendum. Cutting the flue to an exact measurement is not normally required as the telescopic flue terminal can allow for some adjustment. FLUE EXTENSION EXAMPLE The terminal end projects beyond the outside wall by the distance shown in fig. 5 Measure the flue length L from the centre line of the flue turret, along the route of the flue system, to the face of the outside wall. Select the required number of extensions and bends to achieve the require flue run. If the flue requires cutting: Set the telescopic flue length to 00mm. Secure the joint with the screw and tape provided. Subtract 00mm from the measured flue length L to determine the amount to be cut of an extension. Maximum effective flue lengths Greenstar Si, i Junior, i System & Ri Series L max. (mm) 600 Greenstar 0CDi System & Regular 7900 Greenstar 0CDi Regular 6000 Greenstar 7CDi 0000 Greenstar 0CDi 7000 Greenstar 7CDi 6500 Greenstar CDi 6000 British Gas 0i 7900 British Gas 5i 7000 British Gas 57i 6500 British Gas 5i 6000 Table 7 Maximum flue lengths 50 L R 0 50 E T Wo Fig. 5 Flue length determination L Effective length of the flue system R Actual length of the flue sections (L-50 = R) E Extension flue length T Telescopic flue length Table 8 Key to figure b (00/)
9 PRE-INSTALLATION FLUE LENGTH GUIDE Flue length range (mm) Cut Number of extensions FLUE BENDS 0-65 YES None NO None NO None YES NO YES NO YES 00-0 NO 0-50 YES NO YES 5 Table 9 Flue extension guidance up to 600mm NOTE: EFFECTIVE LENGTH B Each flue bend is rated as a certain straight length of flue, refer to table 0 below. The effective length of each bend is added to the straight length of flue. Adding bends to the flue system reduces the actual flue length available. The effective length of the flue must not exceed that stated in the relevant appliance Installation, commissioning and service manual. 5 BENDS Figure 7 shows a possible application for a 5 bend that could be used if fluing from the right or left from the boiler. In this application the flue would be 00mm closer to the wall. 89 mm Fig. 7 This application can only be used with the Si, i Junior and i System boilers. 5 Bend offset dimensions ADJUSTING THE TELESCOPIC FLUE LENGTH, STANDARD OR LONGER VERSION 50 mm L 570 mm WALL 00 mm Wo Effective length in metres Si, i junior, Bend i System & Ri CDi Table 0 90 BENDS Figure 6 shows the actual length added by a 90 bend when used in either orientation. mm 7 mm Fig. 8 Standard telescopic flue Extend tube () by withdrawing from tube () to achieve the flue length required, between mm. If using the longer telescopic flue, extend tube () by withdrawing from tube () to achieve the flue length required, between mm. 570 mm L 790 mm Wo 960 mm Fig Bend offset dimensions Wo Fig. 9 Longer telescopic flue Wo Secure with screw provided and seal joint with the aluminium tape supplied b (00/) 9
10 PRE-INSTALLATION REDUCING THE TELESCOPIC FLUE LENGTH Ensure that the TOP label of both sections are aligned before securing the two parts at the required length. The flue terminal MUST be fitted with the 'TOP' label uppermost to allow the correct fit and use of the plume management system. B Remove securing screws () to detach the terminal assembly from the turret. B Slide terminal section () from the terminal assembly and discard. B To use terminal () without cutting remove the location lug () on the inner flue tube (5) and remove any burrs. From standard telescopic flue 5 From longer telescopic flue 65 mm 0 mm MIN 6 85 mm mm MIN Wo Fig. Further reduction REDUCING EXTENSION FLUE TUBE LENGTH Fig. 0 Reducing the telescopic terminal Wo To reduce the telescopic flue length further: B Mark the length required for the terminal as shown in figure (min. 0mm) and cut square, taking care not to damage the tubes. B Remove any burrs and chamfer the outer edge of the tubes to assist ease of connection and prevent seal damage. A 0mm short extension is available B Mark the extension tube to the required distance, measuring from the socket end and cut the tube square, taking care not to damage the tubes. B Remove any burrs and chamfer the outer edge of the tubes to ease the connection and prevent damage to the seals. The aluminium tape is not required when reducing the terminal Wo Fig. Cutting an extension tube b (00/)
11 INSTALLATION INSTALLATION. TELESCOPIC FLUE INSTALLATION. INSTALLING THE TELESCOPIC FLUE: B When using a 00 mm diameter flue, a 5mm diameter hole through the wall is required. However, if installing the flue from inside the property and fitting the weather sealing collar before the flue is pushed through the hole, then a 50 mm diameter hole is required.. B The flue turret of the 00 mm flue has an in-built angle. B If extensions are to be added then the complete flue must rise at an angle of or 5mm for every metre of flue length. 0 B Drill the hole using a suitable core drill. Referring to figure, set the flue length to the distance required, secure with screws. Seal the joint with the aluminium tape. Slide the inner wall seal onto the terminal.. If fitting from inside the building; slide the outer wall seal onto the terminal, locating the ridge on the seal with the groove on the terminal. TOP. Fig. Telescopic flue installation. INSTALLING A HIGH LEVEL TELESCOPIC FLUE: Referring to figure 5, remove and retain the screws securing the telescopic flue to the turret. Disconnect the flue from the turret and discard the turret. Slide the inner wall seal on to the terminal. Set the telescopic flue to the required length and secure with the screws provided.. Seal the joint with the aluminium tape supplied. 5. If fitting the flue from inside the property, slide on the outer wall seal, locating the ridge on the seal with the groove on the terminal Wo Fig. Telescopic flue Wo Referring to figure, remove the three screws securing the flue outlet to the boiler. Check the boiler flue seal is correctly seated and apply silicone grease. Position terminal through the flue opening in the wall to the outside of the building by the distance shown Align the flue turret to the boiler flue outlet with flat facing to the rear of the boiler. Push the flue turret straight down into the boiler flue outlet. Fig. 5 Preparing the telescopic flue Wo B Fit the screws remove in step to secure flue turret. B If fitting the outer seal from outside the building, slide the outer wall seal onto the terminal as shown, locating the ridge on the seal with the groove on the terminal b (00/)
12 INSTALLATION Referring to figure 6, fit the telescopic flue firmly into the 90 bend. Fit the 90 bend firmly into the extension piece. Fit the vertical flue adapter to the end of the extension.. FLUE TERMINAL PLUME RE-DIRECTION The flue discharge can be re-directed to allow some plume redirection control. Alternatively, a complete plume management system can be fitted to the flue terminal. RE-DIRECTING THE FLUE DISCHARGE NOTE: DO NOT ROTATE THE COMPLETE FLUE TERMINAL ASSEMBLY. B The flue terminal outlet has built-in stops to limit rotation for horizontal fluing. This allows condensate to run back to the boiler for safe disposal. Do not attempt to force beyond the limit stops. Using a suitable tool, unclip the end of the terminal. Rotate the end by 80 and refit the terminal end, ensuring to engage the clips to secure. Fig. 6 Assembling the extensions Wo Loosen the screws securing the entire outlet assembly and rotate by ± 80 to the desired position and re-secure the assembly. Referring to figure 7, remove and discard the three screws securing the flue outlet in the boiler. Check the boiler flue seal is correctly seated and apply silicone grease. Position terminal through the flue opening in the wall to the outside of the building by the distance shown.. Align the vertical flue adapter to the boiler flue outlet with flat facing to the rear of the boiler. Push the adapter straight down into the boiler flue outlet. 5. Secure the telescopic flue bends and extensions with the screws provided. 6. Secure the vertical flue adapter to the boiler with the screws provide in the adapter kit. 80 ± Fig. 8 Plume redirection Wo Wo Fig. 7 Fitting the high level horizontal flue b (00/)
13 INSTALLATION NOTE: OUTLET POSITIONS B The flue terminal outlet position must follow those stated in figure When redirecting the flue discharge the terminal end must be at least 500mm from any opening in the direction of the discharge to prevent combustion products from entering the building as shown. EXTENDED FLUE INSTALLATION NOTE: CONDENSATE DISPOSAL B All horizontal flue sections must rise by at least 5mm per metre away from the boiler to ensure that the condensate flows back into the boiler for safe disposal via the condensate waste pipe. m m Fig. 0 5mm 0mm Slope for condensate disposal Wo To ease assembly of the flue components, lightly grease the seals with the solvent-free grease supplied. Check all the seals are properly seated in the grooves provided and are in good condition. All flue joints must be sealed to prevent leakage of condensate and flue products Wo Fig. 9 Plume distance to opening Opening in building Flue discharge Terminal end Minimum 500mm from an opening in the building Table Key to figure b (00/)
14 INSTALLATION INSTALLING AN EXTENDED FLUE Remove the screws retaining the flue to the turret. Disconnect the flue () from the turret (). Slide the support clamp (optional item ) onto the flue extension as shown.. Push fit the extension () as far as possible into the flue turret. 5. Drill through the turret screw holes into the flue outer tube, take care not to drill into the inner tube. Secure the extension to the turret with the screws removed earlier. Fig. The flue terminal MUST be fitted with the TOP upper most to allow the correct fit and use of the plume management system. 5. Flue extensions Remove the three screws from around the flue outlet on the boiler and retain. For CDi models, the screw pack is in the boiler. Ensure that the boiler flue seal is seated correctly, and apply silicone grease to the seal. Fit the flue turret to the boiler flue outlet and rotate to the direction required, ensuring the flat on the clamp ring is facing the rear of the boiler Wo B Refer to figure and slide the support clamps () onto the additional flue extensions (). Working from the boiler, fit the support clamps () and extensions (), to take the weight of the flue. Drill two holes, 80 apart, through the outer flue tube of each extension, take care not to drill into the inner flue tube, and secure with the screws provided. Fig. Extensions Refer to figure and slide the inner wall seal onto the terminal. If fitting the flue from inside the building, slide the outer wall seal onto the terminal, locating the ridge on the seal with the groove on the terminal. Position the terminal assembly through the opening in the wall to the outside. Push the flue into the extension as far as possible.. Drill two holes, 80 apart, through the outer flue tube of each extension, take care not to drill into the inner flue tube, and secure with the screws provided. 5. If using the telescopic flue, slide the assembly until the flue terminal projects out of the wall by 0mm. Secure the flue with the screw provide and seal the joint with the tape provided. B If fitting from outside the building, slide the outer wall seal onto the terminal, locating the ridge on the seal with the groove on the terminal Wo 5. TOP 0 Fig. Extended flue turret fitting Wo Fig. Extended flue Wo b (00/)
15 PRODUCT INFORMATION 5 PRODUCT INFORMATION 5. PLUME MANAGEMENT SYSTEM COMPONENTS PLUME MANAGEMENT COMPONENTS Ø 60mm PLUME MANAGEMENT KIT comprising: Terminal bend Extension 500mm Outlet assembly Part No.: EXTENSION COMPONENTS Ø 60mm EXTENSION comprising: 5 Extension 000mm 6 Clamp pack 90 BEND comprising: Part No.: Clamp pack Table 60mm Plume management kit 7 90 Bend 5 BEND comprising: 8 5 Bend x Terminal guard 9 Terminal guard Table 60mm Extension Part No.: Part No.: Part No.: Wo 6 Fig. 5 Plume management kit components Wo Fig. 6 Plume management extension components b (00/) 5
16 PRE-INSTALLATION 6 PRE-INSTALLATION 6. PLUME MANAGEMENT TERMINAL POSITIONS All measurements in millimetres ±5 Plume management deflector: 8 80 ±80 Flue Exhaust Outlet Air Intake Balcony, Boundary Window Window Door Window Drainpipe Wo Fig. 7 Plume terminal positions NOTE: B Refer to figure for all concentric flue terminal positions unless the flue position is specified on the figure above Plume terminal positions. B All measurements are the minimum clearances required. B Terminals must be positioned so to avoid combustion products entering the building. B Support the flue at approximately one metre intervals and at a change of direction, use suitable brackets and fittings. Key to illustration 600 mm distance to a boundary or surface facing a boundary, unless it will cause a nuisance. BS 50: Part recommends that care is taken when siting terminals in relation to boundaries. Internal/external corners. The air intake clearance can be reduced to 50 mm providing the flue exhaust outlet has a 00 mm clearance. The flue cannot be lower than,000 mm from the top of the light well due to the build up of combustion products..,00 mm between air intake and facing terminal. 5. Clearance no less than 00 mm from the lowest point of the balcony or overhang. Installations in car ports are not recommended. 6.,00 mm from an opening in a car port on the same wall i.e. door or window leading into dwelling. 7. Using a Plume Management Kit the air intake measurement can be reduced to 50 mm providing the flue exhaust outlet has a 00 mm clearance. Plume kits running horizontally must have a 0 fall back to the boiler for proper disposal of condensate. For details on specific lengths see relevant boiler Technical & Specification information. 8. This feature allows some basic plume re-direction options on a standard telescopic horizontal flue terminal. 00 mm minimum clearances to a opening e.g. window. However the minimum clearance to an opening in direction that the plume management is facing, must be increased to,500 mm. Where the flue is less than 50 mm to a drain pipe and plume re-direction is used the deflector should not be directed towards the drainpipe b (00/)
17 PRE-INSTALLATION 6. PLUME MANAGEMENT OPTIONS & MEASUREMENT NOTE: PLUME MANAGEMENT B All plume management sections must rise away from the terminal by a minimum of 7mm per metre (0 ) to allow the condensate to drain back to the boiler. The figure 8 shows the components required for typical plume management configurations. PLUME MANAGEMENT KIT 5 7 Fig Wo Plume management with bend Fig Wo Plume management components Terminal bend Extension 500mm Outlet assembly Clamp Table Key to figure PLUME MANAGEMENT OPTIONAL KIT Wo Fig. 9 Optional components 5 Extension tube 00mm and Clamp 6 90 Bend 7 5 Bend Table 5 Key to figure 9 Fig Wo Plume management with straight extension NOTE: PLUME MANAGEMENT LENGTH B Measurement M must be a minimum of 500mm and must not exceed the maximum straight length for a horizontal Ø 60/00mm flue or a 60mm plume management system as stated in the relevant appliance Installation, commissioning and service manual or addendum b (00/) 7
18 PRE-INSTALLATION 6. DETERMINE THE PLUME MANAGEMENT SYSTEM LENGTH Fig. Effective lengths L and M Effective Flue length L mm Fig. 8,000 7,000 6,000 5,000,000,000,000,000 MINIMUM PLUME KIT LENGTH 500 mm ,500,500,500,500 Plume management length allowed M mm Effective flue lengths versus plume management lengths Maximum Plume Length for all boilers 7CDi Si, i Junior, i System & Ri 0CDi Regular, System & BG0/i 0CDi BG5/i 7CDi & BG57/i CDi, 0CDi Regular & BG5/i PLUME LENGTH The minimum plume length for all boilers stated on the front page of this manual is 500mm. Refer to figure to determine the appropriate plume length versus the flue length (L). For the CDi range of boilers, the available plume length (M) is reduced as the flue length (L) increases. Any flue must have a minimum of 500mm plume length. The Si, i System, i Junior and Ri can use up to,500mm of plume management regardless of flue length. The flue length is the effective length (L), which includes the effective length of any bends plus the straight flue lengths. Once the length L is know, find that value on the vertical scale of the graph and read that across to the line that represents the installed boiler. From that point read down to the horizontal scale to determine the maximum plume length (M) allowed b (00/)
19 PRE-INSTALLATION 6. MEASURING FOR A PLUME MANAGEMENT SYSTEM All boilers have a maximum permissible plume management length, refer to figure Measure the plume management flue (M) from the centre of terminal, along the required route to the centre of the plume outlet. Fig. Plume management length M Wo ADDITIONAL BENDS: Adding bends to the plume management system reduces the actual plume management length. Each bend has an equivalent straight length and must be factored into the overall effective length. 90 bend is equivalent to 500mm. 5 bend is equivalent to 750mm Fig. 5 Plume management bends Wo EXAMPLE: Using two 5 bends will reduce the permissible length by 500mm. A Greenstar 8i junior has a maximum permissible plume management length of 500mm, so using two 5 bends will reduce the straight length to 000mm b (00/) 9
20 INSTALLATION 7 INSTALLATION 7. STANDARD PLUME MANAGEMENT INSTALLATION To ease assembly of the flue components, lightly grease the seals with the solvent-free grease supplied. Check all the seals are properly seated in the grooves provided and are in good condition. All flue joints must be sealed to prevent leakage of condensate and flue products. NOTE: PLUME MANAGEMENT B All plume management sections must rise away from the terminal by a minimum of 7mm per metre (0 ) to allow the condensate to drain back to the boiler.. 65 mm. ±80 FITTING THE STANDARD PLUME MANAGEMENT SYSTEM: Refer to figure 6 for terminal bend installation. Remove and retain the screws and discard the terminal end. Fit the new terminal bend to the terminal outlet and secure with the screws removed previously Wo Mark the position for the wall clamp so that it coincides with the extension tube just below the top fitting (Refer to figure 7 point ). Drill a hole to suit the wall plug and fit the wall plug. Fig. 6 Terminal bend installation ±5. Screw the clamp into the wall plug to the distance shown in figure 6. NOTE: DO NOT ROTATE THE COMPLETE FLUE TERMINAL ASSEMBLY. B The flue terminal outlet has built-in stops to limit rotation for horizontal fluing to allow condensate to run back to the boiler for safe disposal. Do not attempt to force beyond the limit stops. 5.. Refer to figure 7 plume management installation. Push the extension tube fully into the terminal bend, then withdraw the tube by approximately 0mm to allow for expansion. Secure the extension to the wall with the clamp and screws provided. 0 mm Push the outlet assembly fully into the extension tube.. Rotate the outlet assembly to the required direction. 5. Secure the outlet to the extension with the selftapping screw provided. Fig. 7 Plume management installation Wo b (00/)
21 INSTALLATION 7. EXTENDED PLUME MANAGEMENT INSTALLATION To ease assembly of the flue components, lightly grease the seals with the solvent-free grease supplied. Check all the seals are properly seated in the grooves provided and are in good condition. All flue joints must be sealed to prevent leakage of condensate and flue products. NOTE: PLUME MANAGEMENT B All plume management sections must rise away from the terminal by a minimum of 7mm per metre (0 ) to allow the condensate to drain back to the boiler. Refer to figure 8 and assemble the plume extensions. Mark the position for the wall clamp that coincides with the extension tube, as shown. Drill a suitable hole and fit the wall plug. Screw the clamp into the wall plug as shown. Push the extension tube fully into the terminal bend, then withdraw the tube by approximately 0mm to allow for expansion. Secure the extension to the wall with the clamp and screws provided.. Mount the other extension tubes as before and secure to the wall 5. Push the outlet assembly fully into the extension tube. 6. Rotate the outlet assembly to the required direction and secure the outlet to the extension with the selftapping screw provided. FITTING THE EXTENDED PLUME MANAGEMENT: Refer to figure 6 and remove and retain the screws securing the terminal end and discard the terminal end. Fit the terminal bend to the terminal outlet and secure with the screws retained earlier. If required, rotate the terminal bend for angled fluing. 6.. ±5 5. NOTE: DO NOT ROTATE THE COMPLETE FLUE TERMINAL ASSEMBLY. B The flue terminal outlet has built-in stops to limit rotation for horizontal fluing to allow condensate to run back to the boiler for safe disposal. Do not attempt to force beyond the limit stops. 65 mm 0 mm ±80 Fig. 8 Plume extensions Wo b (00/)
22 INSTALLATION 7. INSTALLING A TERMINAL GUARD A Terminal guard must be fitted if the flue is less than two metres from the ground or if a person could come into contact with the flue terminal outlet. NOTE: The terminal end must not be swivelled inside the guard. The terminal end must be mounted at right angles with respect to the wall. The terminal guard does not have to be fitted over the flue inlet, but is recommended to protect the flue from third party damage. B Fit the terminal guard centrally over the flue inlet or outlet. B Mount the terminal guard to the wall utilising the three mounting points attached to the guard. B Fold the gates in the order stated below or the gates will not latch properly. Fold the single pronged gate in and latch onto the guard frame. Fold the two pronged gate in and latch onto the guard frame. Fig. 9 Terminal guard - flue outlet Wo Fig. 0 Terminal guard - flue inlet Wo b (00/)
23 INSTALLATION 7. REDIRECTING THE FLUE DISCHARGE The plume deflector can be adjusted to redirect the flue discharge. NOTE: FLUE DISCHARGE B The Plume terminal outlet position must follow those stated in figure 7. When redirecting the flue discharge the outlet must be at least 500mm from and angle at least 5 away from any opening in the direction of the discharge, as shown. This is to prevent combustion products from entering the building. V Wo Fig. Plume direction conditions Opening in the building i.e. air brick, window. Direction of flue products, must be more than 5 from the wall or structure Plume terminal At least 500mm from any opening in the building Table 6 Key to figure b (00/)
24 INSTALLATION 7.5 EXTENDED PLUME MANAGEMENT INSTALLATION FOR A BALCONY / OVERHANG To ease assembly of the flue components, lightly grease the seals with the solvent-free grease supplied. Check all the seals are properly seated in the grooves provided and are in good condition. All flue joints must be sealed to prevent leakage of condensate and flue products.. 00 mm Refer to figure 6 and remove and retain the screws and terminal end. Fit the terminal bend to the terminal outlet and secure with the screws removed earlier. If required, rotate the terminal bend for angled fluing. NOTE: DO NOT ROTATE THE COMPLETE FLUE TERMINAL ASSEMBLY. 5. B The flue terminal outlet has built-in stops to limit rotation for horizontal fluing to allow condensate to run back to the boiler for safe disposal. Do not attempt to force beyond the limit stops. Refer to figure and mark the position for the wall clamp that coincides with the extension tube just below the top fitting. Drill a suitable hole and fit the wall plug. Screw the clamp into the wall plug as shown. 65 mm Push the extension tube fully into the terminal bend, then withdraw the tube by approximately 0mm to allow for expansion. Secure the extension to the wall with the clamp and screws provided. B Mount the other extension tubes as before and secure to the wall. Ensure that the plume outlet, projects at least 00mmpassed the balcony/overhang. 0 mm. Remove the screw from the terminal end and remove the grill. 5. Drill a hole through the plume outlet end and secure the grill in place. Fig. Under balcony installation Wo b (00/)
25 SERVICE AND SPARES 8 SERVICE AND SPARES 8. SERVICING AND MAINTENANCE An annual visual check of the plume management kit must be carried out. NOTE: PAINTING B DO NOT paint the plume management kit! 8. SPARE PARTS Ø 60/00mm Telescopic horizontal flue Collar - flue turret: Part Number: Air sample point plug - flue turret: Part Number: Flue sample point cap with seal - flue turret: Part Number: Terminal outlet assembly: Part Number: Wall seal - Inner: Part Number: Wall seal - Outer: Part Number: Table 7 Key to figure Wo Fig. Spare parts b (00/) 5
26 NOTES b (00/)
27 NOTES b (00/) 7
28 WORCESTER, BOSCH GROUP: TECHNICAL SUPPORT: APPOINTMENTS: SPARES: LITERATURE: TRAINING: SALES: WEBSITE: worcester-bosch.co.uk Worcester, Bosch Group Cotswold Way, Warndon, Worcester WR 9SW. Tel Worcester, Bosch Group is a brand name of Bosch Thermotechnology Ltd b (00/)
Flue Installation. High Efficiency Condensing Boilers
Flue Installation High Efficiency Condensing Boilers Table of contents INTRODUCTION 1 Instruction guidance...4 1.1 Product documentation...4 1.2 Explanation of symbols...4 1.3 Important Notes...4 INSTALLATION
AZB 800. Vertical Flue Gas Ducting Ø60/100mm 7 719 001 884
AZB 800 Vertical Flue Gas Ducting Ø60/100mm 7 719 001 884 Ø120 1310 Ø125 50 125 6 720 610 703-00.1O for Gas Condensing Boilers: OSW Contents Contents Safety instructions 2 Symbols 2 1 Use 3 1.1 General
GREENSTAR HEATSLAVE 12/18, 18/25, 25/32
8 716 106 253f 30/3/10 12:59 Page 1 USER INSTRUCTIONS & CUSTOMER CARE GUIDE FLOOR STANDING OIL FIRED CONDENSING COMBINATION BOILER CONVENTIONAL FLUE & ROOM SEALED FLUE GREENSTAR HEATSLAVE 12/18, 18/25,
6720616592.00-1.SD. Flat roof. Rack Mounting. Installation instructions 6 720 647 036 (2010/11) AU
6720616592.00-1.SD Flat roof Rack Mounting AU Installation instructions 2 Contents AU Contents 1 Key to symbols and safety instructions....... 3 1.1 Explanation of symbols................ 3 1.2 Safety
GREENSTAR 24i Junior/28i Junior
USER INSTRUCTIONS WALL HUNG RSF GAS FIRED CONDENSING COMBINATION BOILER GREENSTAR 4i Junior/8i Junior FOR SEALED CENTRAL HEATING SYSTEMS AND MAINS FED DOMESTIC HOT WATER The appliance is for use with Natural
ferroli Boiler Replacement Optimax HE- Modena HE
ferroli Boiler Replacement Optimax HE- Modena HE Introduction The new Ferroli Modena 32C HE high efficiency condensing combination boiler is an ideal replacement for the Ferroli Optimax HE 31 C and the
ASX7-4-IOM-7 J30-08579
INSTALLATION INSTRUCTIONS 4" COMBUSTION AIR INLET KIT TUBULAR GAS FIRED DIRECT SPARK PROPELLER UNIT HEATERS UNIT CONVERSION & CATEGORY III VENTING FOR SEPARATED COMBUSTION For 30,000 to 75,000 BTU/HR SUPPLEMENT
INFRARED QUARTZ WALL HEATER
INFRARED QUARTZ WALL HEATER MODEL NO: IQ2000 PART NO: 6939004 MOUNTING & OPERATION INSTRUCTIONS GC0715 INTRODUCTION Thank you for purchasing this CLARKE Infrared Wall Heater. Before attempting to use this
Flue Options. Ace Finest Finest Gold Best 30/40/50/60 Best 80. Flue Options Flue Options Flue Options Flue Options
Flue Options Ace Finest Finest Gold Best 30/40/50/60 Best 80 Flue Options Flue Options Flue Options Flue Options B r i t i s h M a d e B o i l e r s Halstead have been manufacturing boilers in the UK since
AquaNova. Water heater. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER
AquaNova Water heater Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER Vokèra is a licensed member of the Benchmark scheme which aims to improve the standards of installation
3 IN 1 BATHROOM HEATER
3 IN 1 BATHROOM HEATER MODEL NO.: A515 - SH MINI FUNCTION: HEATER, EXHAUST FAN AND LIGHT Dear customers, Thank you for selecting the AUPU 3 in 1 Bathroom Heater. Please read all instructions before commencing
8 716 473 216-00.3O. Gas boiler. Gaz 6000 W WBN 6000-30-H-E-N/L-S2400. Operating instructions for the end customer. 8 716 473 217 (2014/07) en
8 716 473 216-00.3O Gas boiler WBN 6000-30-H-E-N/L-S2400 Operating instructions for the end customer en 2 Contents Contents 1 Key to symbols and safety instructions................... 2 1.1 Key to symbols..................................
plumbing products guide
plumbing products guide radiator pipe guide & seals A significant development in the drive to reduce air leakage and heat loss. Installations such as that shown are all too common. The detail is poorly
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
Alpha InTec 12S, 18S, 28S
Installation and Servicing Instructions Alpha InTec 2S, 8S, 28S Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing System Boilers For Technical help or for Service
GREENSTAR CDi WALL HUNG RSF GAS-FIRED CONDENSING COMBINATION BOILER
GREENSTAR CDi WALL HUNG RSF GAS-FIRED CONDENSING COMBINATION BOILER FOR SEALED CENTRAL HEATING SYSTEMS AND MAINS FED DOMESTIC HOT WATER 6 720 611 927-00.1O THE APPLIANCE IS FOR USE WITH NATURAL GAS OR
The NEW Greenstar i. intuitive. innovative. improved performance. installation ease
The NEW Greenstar i innovative intuitive improved performance installation ease A NEW look, NEW features and a NEW NAME for the UK s best selling boiler, the Greenstar i Junior 1 Introducing the new Greenstar
Installation Instructions For Slider Casement Air Conditioners
Installation Instructions For Slider Casement Air Conditioners NOTE: These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash, or installation in a metal CASEMENT
Alpha InTec 30GS and 40GS
Installation and Servicing Instructions Alpha InTec 30GS and 40GS Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers with a Passive Flue Gas Heat Recovery
Morco House Riverview Road Beverley HU17 0LD. Retrofit or Upgrade a Water Heater in a Caravan Holiday home
Morco House Riverview Road Beverley HU17 0LD Morco Products Ltd Tel: 01482 325456 Fax: 01482 212869 Email [email protected] Web www.morcoproducts.co.uk Retrofit or Upgrade a Water Heater in a Caravan
GC 3 (PF) (THREE OVEN) GAS FIRED POWER FLUE COOKER
GC 3 (PF) (THREE OVEN) GAS FIRED POWER FLUE COOKER Installation Instructions REMEMBER: when replacing a part on this appliance, use only spare parts that you can be assured conform to the safety and performance
Alpha CD13R,18R and 24R
Installation and Servicing Instructions Alpha CD3R,8R and 24R Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Regular Boiler Range For Technical help or for Service call...
Heating and Domestic Hot Water Systems for dwellings Achieving compliance with Part L 2008
Heating and Domestic Hot Water Systems for dwellings Achieving compliance with Part L 2008 Appendix: Guide to the Condensing Boiler Installation Assessment Procedure for Existing Dwellings CONTENTS PAGE
Cooktop Low-Profile Ventilation Hoods
INSTALLATION GUIDE Cooktop Low-Profile Ventilation Hoods Contents Wolf Cooktop Low-Profile Ventilation Hoods........ 3 Cooktop Low-Profile Hood Specifications.......... 4 Cooktop Low-Profile Hood Installation............
Rapide Inline Ceiling Extractor Fan, White Fascia 41800040590. Rapide Inline Ceiling Extractor Fan, Chrome Fascia 41800040580
Any Queries Call : 08000 23 23 23 Rapide Inline Ceiling Extractor Fan, White Fascia 41800040590 Rapide Inline Ceiling Extractor Fan, White Fascia Illuminated 41800040670 Rapide Inline Ceiling Extractor
Instructions for: TTW 1 Universal Service Replacement Blower Kit P/N 265-47200-00
Instructions for: TTW 1 Universal Service Kit P/N 265-47200-00 (To be performed ONLY by qualified service providers) The Blowers on the Following Water Heaters are Serviced by This Kit: MITW -10 Series
Your safety and the safety of others are very important.
NATURAL GAS TO PROPANE CONVERSION KIT 090 INSTALLATION INSTRUCTIONS FOR ALTITUDES 0 -,00 FT. ONLY PROPANE CONVERSION KIT SAFETY... INSTALLATION REQUIREMENTS... Tools and Parts... LP Gas Requirements...
Installation and Servicing Instructions. Eco. Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boiler
Installation and Servicing Instructions Eco Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boiler For Technical help or for Service call... ALPHA HELPLINE Tel:
IMPORTANT INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION
INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER SEALANT REQUIRED TO COMPLETE THIS INSTALLATION: (Not supplied) Sika Sikasil NG (Arctic White) To seal the WHITE shower door and returns to the shower tray.
Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation
Solar Pool Heating System Installation Manual Read the complete manual before beginning the installation 1. Sizing the System Visit www.techno-solis.com to size the system using the sizing calculator.
Operating instructions
6302 6959 02/2006 GB For the user Operating instructions Logano G215 WS Oil and gas-fired boilers Please read thoroughly before use. Overview Regulations and directives Installation: 90/396/EEC gas appliance
Operating instructions
6300 9681 02/2006 GB For the user Operating instructions Logano GE315 Boiler for oil-/gas-fired pressure jet burners Please read thoroughly before use. Operating instructions Logano GE315 Dear Customer,
Mynute 25 A. High efficiency system boiler. Users Instructions. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER
Mynute 25 A High efficiency system boiler Users Instructions Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER Vokèra is a licensed member of the Benchmark scheme which aims
Troubleshoot resources for homeowner http://waterheatertimer.org/troubleshoot-bosch-tankless-water-heater.html
Troubleshoot resources for homeowner http://waterheatertimer.org/troubleshoot-bosch-tankless-water-heater.html Installation / Operating Instructions GOOD.BEETER>BOSCH Water Wizard 600 Continuous Flow Gas
PART 6: VENTING, COMBUSTION AIR & CONDENSATE REMOVAL
PART 6: VENTING, COMBUSTION AIR & CONDENSATE REMOVAL Boiler Manual A. INSTALLING EXHAUST VENT AND INTAKE AIR VENT B. GENERAL n DANGER The Elite Heating Boiler must be vented as detailed in this section.
Installation Instructions
Installation Instructions Pedestal Models FS 500 LE FS 800 LE Insert Models IS 500 LE IS 800 LE Pecan Engineering Pty Ltd 13 Acorn Road Dry Creek South Australia 5094 Email [email protected] Phone:
Combi 30 HE. Installation & Service Instructions
Installation & Service Instructions Combi 30 HE Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. Baxi Heating UK Ltd 2009 Natural Gas Main
Accessory Manual Ventilation Section Model Comfort Circle
Accessory Manual Ventilation Section Model Comfort Circle Manual version:. R a Copyright and trademarks All the information and drawings in this manual are the property of Biddle and may not be used (other
Mikrofill Ethos Condensing combination boiler
Mikrofill Ethos Condensing combination boiler Installation Instructions 24cc CE Mark No: 0201055 British Gas Service Listing G.C.No: 47-157-01 Mikrofill gas appliances comply with the requirements contained
Lunette 2 Series. Curved Fixed Frame Projection Screen. User s Guide
Lunette 2 Series Curved Fixed Frame Projection Screen User s Guide Important Safety and Warning Precautions Please follow these instructions carefully to ensure proper maintenance and safety with your
Part 3 Ancillary technologies. Chapter 3.2. Mechanical ventilation with heat recovery
Part 3 Ancillary technologies Chapter CONTENTS SCOPE Clause Page DESIGN Design standards D1 1 Statutory requirements D2 1 System design D3 1 Building integration D4 2 Noise D5 2 Access and controls D6
Saferand easierinstallation
EN 85-07 Saferand easierinstallation IföSigninstallationsystem andifösignbuilt-incistern www.ifosanitar.com/sign Aneffectivesolution withmanyadvantages. Ifö Sign installation system makes life a little
MULTIPOINT BF Gas Fired Balanced Flue Water Heater
Please leave these instructions with the user MULTIPOINT BF Gas Fired Balanced Flue Water Heater User Operating, Installation and Servicing Instructions 6 720 607 090 GB (04.10) JS Natural Gas Main Multipoint
THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494
THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494 1. BEFORE YOU BEGIN IMPORTANT INSTRUCTIONS READ AND SAVE FOR THE CONSUMER WARNING: Risk of scalding or other severe injury. Before completing installation,
Installation Instructions
READ BEFORE INSTALLING UNIT For Slider Casement Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:
1 DESCRIPTION OF THE APPLIANCE
1 DESCRIPTION OF THE APPLIANCE 1.1 INTRODUCTION The cast iron SF boilers are a valid solution for the present energetic problems, since they can run with solid fuels: wood and coal. These series of boilers
OWNER S MANUAL DRAINVAC ATOMIK PRINTED APRIL 4-2011
OWNER S MANUAL th DRAINVAC ATOMIK PRINTED APRIL 4-2011 INTRODUCTION We take this opportunity to express our gratitude and extend our congratulations for your decision to purchase a Drainvac product. A
MIC-WKT and MIC-WKT-IR
MIC-WKT and MIC-WKT-IR Installation Manual Bosch Security Systems EN Installation and Operation Manual MIC-WKTI and MIC-WKT-IR Installation Manual EN 2 MIC-WKT and MIC-WKT-IR Washer Pump Drive Card Kits
M-9424-463V Intake Manifold INSTALLATION INSTRUCTIONS
Please visit www.fordracingparts.com for the most current instruction information!!! PLEASE READ ALL OF THE FOLLOWING INSTRUCTIONS CAREFULLY PRIOR TO INSTALLATION. AT ANY TIME YOU DO NOT UNDERSTAND THE
Colonnade Security Pipe
Description: Round & Square downpipe formed from extruded 6060 T4 aluminium in various sizes (Ø83mm, Ø108mm, 83x83 mm & 108x108mm*) & supplied with a complete range of accessories i.e. Offsets, bends,
Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.
Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1. Please read and understand these instructions before starting work. Please leave this leaflet
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.
Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV. MULTIPOINT Please read and understand these instructions before starting work. Please leave this leaflet
Installation Instructions for AGA BF Gas Fired Cooker Models GC, GCB, GE and GEB
Gas Fired Cookers Installation Instructions for AGA BF Gas Fired Cooker Models GC, GCB, GE and GEB FOR USE IN GB & IE PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING YOUR AGA Consumer Protection As responsible
Installation and Servicing Instructions. Alpha 240/280. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired Combination Boilers
Installation and Servicing Instructions Alpha 240/280 Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired Combination Boilers For Technical help or for Service call... ALPHA HELPLINE Tel: 0870
!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035
Decra Plus Drawing no DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 Description Shown In Decra Brochure Most Commonly Used Detail t~êã=oççñ=b~îéë=aéí~áä=b~îéë=lîéêü~åö=táíü=fåëìä~íéç=c~ëåá~=~åç=pçññáí
Original Assembly Guide
TCT Multipurpose Single Bevel Sliding Compound Mitre Saw Original Assembly Guide Read instructions before assembling this tool. Table of Contents GB Assembly Guide Read instructions before assembling this
IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White
IMPORTANT INSTRUCTIONS & OPERATING MANUAL Houston 50 Inch Electric Wall Mounted Fireplace Black / White Model Number:MFE5050BK Model Number:MFE5050WH Read these instructions carefully before attempting
Portable Air Conditioner
Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE
Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS
Replacement parts DO NOT SERVICE THE BOILER WITHOUT A WM97+ MAINTENANCE KIT AVAILABLE Failure to adhere to these guidelines can result in severe personal injury, death or substantial property damage. The
Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems
H15-10 Direct Vent Gas Stove Model H15-NG10 H15-LP10 Fuel Type Natural Gas Propane Minimum Supply Pressure 5.0 W.C. (1.25 kpa) 12.0 W.C. (3.00 kpa) Manifold Pressure - High 3.8 W.C. (0.95 kpa) 11 W.C.
Important Information
Single Door Quadrant Instruction Manual ESQ Important Information Toughened glass is completely safe for use in our shower enclosures and bath screens; providing our products are installed according to
SHOT BLAST CABINET MODEL NO: CSB20B
SHOT BLAST CABINET MODEL NO: CSB20B PART NO: 7640110 USER INSTRUCTIONS GC0216 INTRODUCTION Thank you for purchasing this CLARKE Shot Blast Cabinet which is designed for professional workshop use. Before
TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING
6.CW.1A TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS wood or gas standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING The Fireplace Ltd is able to design and fabricate custom brick open masonry
HEAT WAVE DUCT KIT KIT # 946-568
HEAT WAVE DUCT KIT KIT # 946-568 www.regency-fire.com Approved for use with Models: P36, P36D, P42, P48, P90, P95, L676S, P33S & HZ54 WARNING: Improper installation, adjustment, alteration, service or
Duo-tec Combi HE A Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler
User s Operating Instructions & Important Warranty Information Duo-tec Combi HE A Range Gas Fired Wall Mounted Condensing Combination Boiler Please keep these instructions in a safe place. If you move
MAJESTIC. OUTDOOR / INDOOR WOOD FIREPLACES Model: ODSR36A OWNERS INSTALLATION & OPERATING INSTRUCTIONS. KEEP THESE INSTRUCTIONS FOR FUTURE REFERANCE.
MAJESTIC OUTDOOR / INDOOR WOOD FIREPLACES Model: ODSR36A OWNERS INSTALLATION & OPERATING INSTRUCTIONS. KEEP THESE INSTRUCTIONS FOR FUTURE REFERANCE. CONTENTS Part 1: Safety Information Part 2: Installation
1. Description. 2. List of Accessories included A B C F G H
1. Description This unit is a pump that will clear the waste from a domestic shower and washbasin. The unit will start automatically. Please pay particular attention to the following: Possible danger to
CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS
CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS WARNING Improper installation, adjustment, alteration, service, or maintenance of this product can cause
CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS
CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS D E F Y I N G C O N V E N T I O N Congratulations on your new Corner Fridge Your new corner fridge may have different functions
REPAIR INSTRUCTIONS UNDER BODY CYLINDER (UM, UL)
Table of contents 1. Introduction... 3 1.1. Scope of use... 3 1.2. General remarks... 3 1.3. Contact Hyva... 3 1.4. Precautions... 4 1.5. Spare parts... 4 1.5.1. Prior to use... 4 1.6. Recycling and Reuse
BLACK TIE. Instructions Manual
BLACK TIE EN Instructions Manual RECOMMENDATIONS AND SUGGESTIONS The Instructions for Use apply to several versions of this appliance. Accordingly, you may find descriptions of individual features that
CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.
CAST IRON THE BASICS 1. DO NOT LIFT ON YOUR OWN. 2. ONLY LIFT THE RADIATOR VERTICALLY. 3. DO NOT LIFT MORE THAN 8/10 SECTIONS AT ANY ONE TIME. 4. POSITION THE RADIATOR BEFORE FINAL ASSEMBLY. 5. THIS PRODUCT
INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX
Fan Coil Replacement Coil Kit EBX & EBXX These instructions must be read and understood completely before attempting installation. These instructions covers the installation of replacement coil kit into
FREESTANDING CLEAN AIR WOODBURNER
Please read this booklet and keep for future reference for the safe installation of your: FREESTANDING CLEAN AIR WOODBURNER This fire conforms with Ecan Requirements All installations must be in accordance
Reverse Cycle Inverter Split System Air Conditioner
Reverse Cycle Inverter Split System Air Conditioner Model Number TAC-09CHSA/JAI5 INSTALLATION MANUAL Contents 03 Warranty Details 04 Welcome 05 General Safety Instructions 06 Product Overview 07 Selecting
15GAL STEEL OIL DRAIN WITH 110V PUMP
15GAL STEEL OIL DRAIN WITH 110V PUMP OWNER S MANUAL WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety
Figure 22: Typical Individual Venting. Figure 21: Single Water Heater Venting
ING THE WATER HEATER The purpose of venting a gas or oil-fired water heater is to completely remove all products of combustion and to vent gasses to the outside air without condensation in the vent or
IMPORTANT DOCUMENTATION DO NOT DISCARD!
PART NO.: 6441-263C SERIES GRT 3 JAW PARALLEL GRIPPERS INFORMATION SHEET IMPORTANT DOCUMENTATION DO NOT DISCARD! Use this information sheet to assist with gripper installation and setup. File with maintenance
Coolflo Safe Touch Shower Mixing Valve ST20015CP
Coolflo Safe Touch Shower Mixing Valve ST20015CP Installation and Maintenance Instructions In this procedure document we have endeavoured to make the information as accurate as possible. We cannot accept
Operating Instructions
Operating Instructions Cable Glands Ex d and Ex e with Compound > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Safety Information...3 4 Designated Use...4 5 Technical Data...4
SELECTION, APPLICATION & MAINTENANCE
DIESEL PROTECTION SYSTEMS TPZ Engine Air Intake Shut Down Valves (Combined Automatic Overspeed and Air Pressure Operated Shut Down Bendix Types) SELECTION, APPLICATION & MAINTENANCE Valve Numbers TPZ-101
HAIR CLIPPER. Model No. HC5150 HC5150 2. 3.
All technical modifications reserved. 09/08. TSC 08.0634 HAIR CLIPPER 2. 3. 1. Model No. HC5150 4. 10/UK/HC5150 Version 03/10 Part No. T22-29458 REMINGTON is a Registered Trade Mark of Spectrum Brands,
Installing the Broadband Global Area Network (BGAN) Fixed Mount Kit
Installing the Broadband Global Area Network (BGAN) Fixed Mount Kit Product description BGAN fixed mount kit Although the BGAN satellite modem terminal is designed for portable use, the BGAN Fixed Mount
EZ-Steer Assisted Steering System
EZ-Steer Assisted Steering System Installation Instructions Platform Kit P/N 53059-21 Case IH Puma 165 Puma 180 Puma 195 Puma 210 New Holland T7030 T7040 T7050 T7060 Revision A June 2007 Part Number 53345-21-EU2
Installation Instructions
GC 3 (THREE OVEN) Installation Instructions REMEMBER: when replacing a part on this appliance, use only spare parts that you can be assured conform to the safety and performance specification that we require.
IH 17025 E Sigma Island 90
INSTRUCTIONS FOR USE Kitchen extractor hood Type: IH 17025 E Sigma Island 90 Dear Customer!! You are now a user of the newest generation kitchen extractor hood type IH 17025 E Sigma Island 90. This hood
User Guide and Important Warranty Information. Heatmax Combi HE Range. Condensing Combination Boiler
You can rely on User Guide and Important Warranty Information Heatmax Combi HE Range Condensing Combination Boiler Please keep these instructions in a safe place. If you move house, please hand them over
Installation Guide. 5 Series 15 W. Undercounter/Freestanding Nugget Ice Machine
Installation Guide 5 Series 15 W. Undercounter/Freestanding Nugget Ice Machine Table of Contents Warnings & Important Safety Instructions 3 Dimensions (Professional) 5 Dimensions (Custom Panel) 6 Specifications
INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks
Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 [email protected] in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate
39HQ Airovision Air Handling Units
39HQ Airovision Air Handling Units Mounting instructions CONTENTS 1 - TRANSPORT AND LIFTING INSTRUCTIONS... 3 1.1 - General... 3 1.2 - Transport and storage... 3 1.3 - Roof edge protection during transport
1000-LB. TRAILER JACK OWNER S MANUAL
1000-LB. TRAILER JACK OWNER S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious
HALSTEAD. Best db 30/40/50/60 HALSTEAD INSTALLATION & SERVICING INSTRUCTIONS FOR THE
INSTALLATION & SERVICING INSTRUCTIONS FOR THE HALSTEAD CAST IRON HALSTEAD Best db 0/40/50/60 WALL MOUNTED FAN ASSISTED BOILER B R I T I S H M A D E B O I L E R S Best 0 G. C. No. 4 50 Best 40 G. C. No.
Window Installation Instructions
Caution The correct installation methods of windows in full frame or insert applications is critical towards achieving the tested performance of the window and longterm enjoyment and energy savings for
Owner s Manual Read and keep this manual. Patents World Wide
Owner s Manual Read and keep this manual. Patents World Wide S & S Industries, Inc., Sarasota, FL, USA www.trail-gator.com Copyright 2008 All Rights Reserved The following manual is provided to assist
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS
UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS: Carefully read these instructions before installing your new air-conditioner. AUSTRALIAN AUTOMOTIVE AIR AL00500054E 1 Table
Wren Kitchens Installation Tips... 3. Carefully check your kitchen delivery... 4. Measuring out and marking up... 5. Fitting the base cabinets...
tra 1 Index Wren Kitchens Installation Tips... 3 Carefully check your kitchen delivery... 4 Measuring out and marking up... 5 Fitting the base cabinets... 6 Fitting the corner cabinets... 7 The 972mm or
Combi 24 HE. User s Guide and Important Warranty Information
User s Guide and Important Warranty Information Combi 4 HE Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier. Baxi Heating UK Ltd 0 Contents
IMPORTANT INFORMATION
Curved Quadrant Instruction Manual CQ IMPORTANT INFORMATION Toughened glass is completely safe for use in our shower enclosures and bath screens; providing our products are installed according to our guidelines.
