Worcester DS/DM Series UltraSwitch Switch box



Similar documents
XCL Series Switchbox. Product Information. ATEX II 2 G EEx d IIB T5 Cl. 1, Div.1, Grp.CD

Plastic tube flowmeters Series PT/PS

JAMESBURY QUARTZ LIMIT SWITCH FOR HAZARDOUS AREAS AND GENERAL PURPOSES

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

Compact pressure switch Flameproof enclosure Ex d Model PCA

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Explosion proof enclosures

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

2.12. page Products for Explosion hazardous Environment

Kämmer Series Laboratory Valves

Technical Data. Dimensions

Scraper Passage Indicator. Electrical Indicator. Features

Technical Data. Dimensions

Inductive sensor NI10-M18-Y1X-H1141

Electronic, Digital and Mechanical Vibration Switches

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel

Uni-Valve A /S UNI-ITS. UNI-ITS100 - Mechanical switches. Installation and operating manual. Position monitoring switch

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Series 8146/5-V37 and Series 8150/5-V37

D20 Compact Digital Positioner. Product Information

Solenoid Valve Island Type 3965

Flow switches Series AD/VH

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Experience In Motion. Valtek Spring Cylinder Linear Actuators

Linear Luminaire with LED Series EXLUX 6402/2

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Connection technology from ifm.

TECHNICAL BULLETIN. Kämmer LinedFlow Corrosive Application Valves. Experience In Motion FCD KMENTB /12

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Solenoid Valve Type 3962

Control- and feedback head for integrated mounting on Robolux valves Type 2036

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.

MR221-MR222 Heavy Duty Geared Limit Switches, CE Approved

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

Electric Rotary Actuator - On/Off or programmable control actuator

B-Series Temperature Switches

Rosemount 752 FOUNDATION fieldbus Remote Indicator

Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating: Cable: Cable Glands:

STB Series Enclosures

BUTTERFLY VALVES API 609 WAFER LUG U-SECTION BODY STYLE DIAPHRAGM VALVES EN13397:2000 WEIR BODY STYLE

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Control and Distribution Boxes made of Stainless Steel Series 8150

Series 3730 Type Electropneumatic Positioner

Technical Information RIA14

Technical data sheet TDS0070

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Know-how makes the difference. Electrical Actuators

Operating Instructions

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

Flameproof Audible Signal 115 db (A) Series YA90

Order Code for GEA Tuchenhagen VESTA Sterile Valves. Type H_A 2/2 Way Seat Valve

4 Dynamic Solutions. Leadership and Innovation in Valve Products and Valve Systems

Color Mark Sensor with Red or Green LED E3S-VS

B-Series Switches Pressure, Differential Pressure & Hydraulic

STX2100. Differential Pressure (Flow) Transmitter. GE Measurement & Control. Models FKC...5. Features

Stainless Steel and Mild Steel Enclosures. Stainless Steel and Mild Steel Enclosures

Micro Motion 3098 Gas Specific Gravity Meter

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Threaded Resistance Thermometers Model TR10-D, Miniature Design

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

3DLevelScanner II TECHNICAL DATA SHEET

Technical Specifications

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Terminal Boxes Series 8146

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.

Microcor Wireless Transmitter (MWT)

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Fisher FIELDVUE DVC6200 SIS Digital Valve Controller for Safety Instrumented Systems (SIS)

Floodlight Range Installation Guide

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

Thermometer in stainless steel with capillary and switch contacts

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Inductive slot sensor

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

SEISMIC VELOCITY TRANSDUCER T1-40

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Series 3730 Type Electropneumatic Positioner with FOUNDATION fieldbus communication

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features

Tyco PremiAir Pneumatic Actuators

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

Brooks Models MT 3809 and 3819 Metal Tube Variable Area Flowmeters with Optional Transmitters and Alarms

Instructions for Safe Use

RUBBER SLEEVE KNIFE GATE VALVE

Rotary Actuators, NAMUR interface VDI/VDE 3845 & ISO 5211 (ATEX certified) Series ARP

2/2 and 3/2 Solenoid Control Valves

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Fisher 377 Trip Valve

167D Series Switching Valves

Single sub-base valve

IMVIB. Online vibration monitoring for Ariel compressors

LSB Series. Valve Position Monitor. All innovation on driving your valve automation

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

HID/FLOODLIGHT: ATEX/IECEx FLAMEPROOF. Applications

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

Norbro Series 40R Pneumatic Actuator Double Acting or Spring Return

ISO-9001:2000 certified. EE300 Series Electromechanical Inventory Level Measuring System. Aplus Finetek Sensor, Inc.

Transcription:

Worcester DS/DM Series UltraSwitch Switch box

Features DS/DM Series Ultraswitch Description The DS/DM Series UltraSwich from Flowserve Worcester provides cost efficient, accurate and reliable position signaling for hazardous locations. The sturdy enclosure is offered in aluminum or corrosion resistant stainless steel and is provided with multiple switch options. An external indicator is available. The DS/DM is designed to be directly and easily mounted onto actuators for both rotary and linear indication. It may also be used as a junction box for direct connection of solenoid valves. Minimum two open terminals are always provided. Its compact housing has multiple mounting possibilities, up to three conduit entries and pre-wired switches to enable easy installation. It is designed to meet IP66 and NEMA Type 4X standards and is offered for general purpose/weather proof and for explosion proof hazardous locations. Features and Benefits Tool-free Quick-Set cams SIL 2 ATEX Ex d IIC T4 IECEx Ex d IIC T4 ccsa Class I, Division 1/2, Groups B,C,D, T6 CSAus Class I, Division 1/2, Groups A,B,C,D, T6 ccsaus NI Class I. Division 2. Groups A, B, C, D Switches available in a wide range of options (See Technical Data page - switch options) Easily accessed pre-wired terminal strip Minimum two open terminals are provided Housing of aluminum or corrosion resistant stainless steel Temperature range -55 C to +85 C -67 F to +180 F Optional 4-20mA feedback signal Conduit entries (2x) 3/4 NPT or (2x) M25x1.5mm (third entry optional) 2

Hazardous Locations Approvals Typical applications / industries suitable for the DS/DM-Series UltraSwitch are: Chemical Oil & Gas Pharmaceutical Offshore Hazardous locations approvals and communication Explosion proof: Approvals for: ATEX Ex d IIC T4 IECEx Ex d IIC T4 ccsa Class I, Division 1/2, Groups B,C,D, T6 CSAus Class I, Division 1/2, Groups A,B,C,D, T6 ccsaus NI Class I. Division 2. Groups A, B, C, D AS-Interface (AS-i) The DS/DM-series can be equipped with optional AS-i communication capabilities. This technology offers a very simple, flexible and cost efficient network system. Mounting options and visual indication NAMUR mounting kit with Indicator NAMUR mounting Standard NAMUR EN15714 mounting kits are available for standard NAMUR shafts. Available for 80x30 and 130x30 actuator top patterns with an actuator shaft height of 20, 30 or 50 mm. For linear applications the optional L shaft can be ordered. Visual indicator also shown. Mounting kit NAMUR p/n 23648 23649 23650 B C A = Bolt pattern length (mm) 80 80 130 A B = Bracket height (mm) 45 55 55 30 mm C = Height (mm) 145 155 155 3

Housing Aluminum or Stainless Steel housing Powder Epoxy painted Aluminum housing Base always black. Covers in black (standard), white or optional cover color on request Corrosion free Stainless Steel housing Unpainted stainless steel DIN 1.4408 4

Technical Data Switch Options Data/Materials Code Switch Option Manufacturer Load Capacity M1 SPDT Mechanical Honeywell MicroSwitch 15A @ 125/250 VAC; 0,5A @ 125 VDC; 0,25A @ 250VDC; 5A @ 120VAC MG SPDT Gold Mechanical Honeywell MicroSwitch 1A @ 125 VAC; 50 ma @ 24 VDC MC SPDT Mechanical Honeywell MicroSwitch Mechanical switch 250 F F3 IF5250 IFM 10-36VDC NC PNP, 150mA, 3-wire NC F5 IF6001 IFM 18-32VDC, NO PNP, 150mA@50 C F6 IF6034 IFM 10-36VDC, NO PNP, 150mA, Stainless Steel F7 IN0074 IFM 20-250 AC/DC NO, 350mA/100mA F8 IN0081 IFM 20-250 AC/DC NO, 350mA/100mA w/led P4 SPST Proximity Aleph 0.35A @ 140 VAC; 0.25A @ 200VDC (50 W Max.) P5 SPDT Proximity Hamlin 0.25A @ 120 VAC; 0.25A @ 28 VDC (3 W Max.) PE SPDT Sabre Proximity Flowserve 1A @ 120 VAC; 1A @ 24 VDC PP SPDT Phazer Proximity Flowserve 3A @ 120 VAC; 2A @ 24 VDC PT SPST BRS Proximity Flowserve 3A @ 120 VAC; 0.5 @ 24 VDC N3 Slotted NAMUR PF SJ3.5-S1N NAMUR NO 2-wire Safety function N8 Solid State Proximity PF NJ2 V3 N NAMUR NC Sensor; 8 VDC N9 Solid State Proximity PF NBB3-V3-Z4 NPN Sourcing; 100 ma max. Current; 5-60 VDC NP Solid State Proximity PF SJ3.5-N NAMUR Sensor Output; 5-25 VDC Supply NQ Solid State Proximity PF NJ4-12GK-N NAMUR NC Sensor; 8 VDC NR Solid State Proximity PF NJ4-12GM40-E1 PNP Sinking; 200 ma max. Current; 10-60 VDC NS Solid State Proximity PF NJ4-12GM40-E2 NPN Sourcing; 200 ma max. Current; 10-60 VDC NT Solid State Proximity PF NJ4-12GK40-E2 NPN Sourcing; 200 ma max. Current; 10-60 VDC NW Solid State Proximity PF SJ3.5-SN NAMUR NC Sensor; 8 VDC Data Ingress protection IEC 529 IP 66 Weight 1.8kg / 4 lbs Aluminum housing Weight Stainless Steel housing Part Housings & Covers Shaft Cams/Splines Terminal Block Internal Brackets All External Fasteners All Internal Fasteners Indicator Label Certificate ATEX IECEx 3.5kg / 7.75 lbs Material Powder epoxy painted Aluminum or Stainless Steel Stainless Steel Nylon Nylon Nylon, Aluminum or Stainless Steel Stainless Steel Stainless Steel Polyurethane Polyester or Stainless Steel II 2GD Ex d IIC T4 Gb Ex tb IIIC T113 C Db Ex d IIC T4 Gb Ex tb IIIC T113 C Db ccsa Class I, Division 1/2, Groups B,C,D, T6 CSAus Class I, Division 1/2, Groups A,B,C,D, T6 ccsaus NI Class I. Division 2. Groups A, B, C, D More switch options available 5

DS/DM-Series Ultraswitch Switch box Nomenclature A = B = C = D = E = F = G = H = I = J = K = L = M = Product & Connections (cable entry) DS Explosion proof / Flame proof switch box with 3/4 NPT cable entries DM Explosion proof / Flame proof switch box with M25x1,5 cable entries Number of open cable entries 2 2 x open cable entries (standard) 3 3 x open cable entries (option) Housing material /Surface treatment B Aluminum housing, polyester powdercoating, Black base & cover W Aluminum housing, polyester powdercoating, Black base & White cover C Aluminum housing, polyester powdercoating, Black base & Optional cover color S Stainless Steel housing Shaft D Double D Shaft 1/4 N Namur VDI/VDE 3845 Shaft (rotary actuators) T For NAF Turnex actuators L D style including nut for linear applications Indicator option 0 No indicator 1 Indicator below switch box Qty of switches 0 0 Switches 2 2 Switches 4 4 Switches Switch options - see page with switch options Certificate 14 General Purpose 18 ccsa Class I, Division 1/2, Groups B,C,D; Class II, Division 1/2, Groups E, F, G; Class III CSAus Class I, Division 1/2, Groups A,B,C,D; Class II, Division 1/2, Groups E, F, G; Class III; 19 ATEX II 2GD, Ex d IIC T4 Gb, Ex tb IIIC 25 IECEx Ex d IIC T4 Gb, Ex tb IIIC 28 ccsaus NI Class I. Division 2. Groups A, B, C, D. Product approval marking 0 Self-adhesive marking label, Polyester M Stainless steel marking plate Analog Output 0 None 4 4-20mA transmitter (G= none, M1 or MG only) Terminal Options 2 2 Extra open terminals (Standard) 4 4 Extra open terminals (Optional, not possible for all switch options) 6 6 Extra open terminals (Optional, not possible for all switch options) 8 8 Extra open terminals (Optional, not possible for all switch options) H Heavy Duty Terminal Block, 8 contact points. Options/ Elastomers 0 Nitrile O-rings V Viton O-rings Brand W Worcester Ordering code example A B C D E F G H I J K L M DS 2 B N 1 2 MG - 14-0 0 2 0 W 6 Explosion proof / Flame proof switch box with 3/4 NPT cable entries, 2 Cable entries, Aluminum housing, NAMUR shaft, Indicator, 2 switches MG, General purpose, label, No output, 2 Extra terminals, Nitrile O-rings, Worcester Brand

Dimensions DS/DM (mm/inch) M6(4X) Ø 125 (4.213) 35,4 (1.394) 57,2 (2.252) 3/4-14 NPT OR M25x1.5 (1-3x) 149 (5.866) 4 (.157) 93 (3.740) 99,3 (3.090) 15(.590) Ø56 (2.203) 137,5 (5.413) 57,2 (2.252) 35,4 (1.394) 21(.827) 5/16-18 UNC(4X) Clearance=145 (5.701) 7

Flowserve Corporation Flow Control Division 1978 Foreman Drive Cookeville, Tennessee 38501 USA Phone: +931 432 4021 Fax: +931 432 5518 Flowserve Flow Control (UK) 44 Victoria Way, Burgess Hill West Sussex, RH15 9NF UNITED KINGDOM Tel: +44 (0) 1444 884846 E-mail: pmvuksales@flowserve.com flowserve.com FCD WCENBR0136-02-A4-07/15 To find your local Flowserve representative: For more information about Flowserve Corporation, visit flowserve.com Hazardous Locations ATEX II 2GD Ex d IIC T4 Gb Ex tb IIIC T113 C Db IECEx Ex d IIC T4 Gb Ex tb IIIC T113 C Db ATEX Ex d IIC T4 IECEx Ex d IIC T4 ccsa Class I, Division 1/2, Groups B,C,D, T6 CSAus Class I, Division 1/2, Groups A,B,C,D, T6 ccsaus NI Class I. Division 2. Groups A, B, C, D Flowserve Corporation has established industry leadership in the design and manufacture of its products. When properly selected, this Flowserve product is designed to perform its intended function safely during its useful life. However, the purchaser or user of Flowserve products should be aware thatflowserve products might be used in numerous applications under a wide variety of industrial service conditions. Although Flowserve can (and often does) provide generalguidelines, it cannot provide specific data and warnings for all possible applications. The purchaser/user must therefore assume theultimateresponsibility for the proper sizing and selection, installation, operation, and maintenance of Flowserve products. The purchaser/user should read and understand the Installation and Maintenance (I & M) instructions included with the product, and train its employees and contractors in the safe useof Flowserve products in connection with the specific application. While the information and specifications contained in this literature are believed to be accurate, they are supplied for informative purposes only and should not be considered certified or as a guarantee of satisfactory results by reliance thereon. Nothing contained herein is to be construed as a warranty or guarantee, express or implied, regarding any matter with respect to this product. Because Flowserve is continually improving and upgrading its product design, the specifications, dimensions and information contained herein are subject to change without notice. Should any question arise concerning these provisions, the purchaser/user should contact Flowserve Corporation at any one of its worldwide operations or offices. 2015 Flowserve Corporation, Irving, Texas, USA. Flowserve and PMV are registered trademarks of Flowserve Corporation.