Fire Control Panels. Remote Annunciator Panels. UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Features. Introduction



Similar documents
Fire Control Panels. Addressable Fire Detection and Control Emergency Voice/Alarm Communications Equipment

Fire Control Panels Series Remote InfoAlarm Command Center for the 4010ES Fire Alarm Control Panel

TrueAlarm Fire Alarm Systems

Life Alarm Fire Alarm Controls

TrueAlarm Fire Alarm Systems

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description

4100ES Fire Control Panels

Fire Fighter Phone System Installation Instructions

TrueAlarm Fire Alarm Controls

SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

AC-115 Compact Networked Single Door Controller. Installation and User Manual

HONEYWELL COMMERCIAL FIRE/BURG PANEL UL LISTING REQUIREMENTS (Compiled from VistaFBPT Installation Instructions V1 Rev A 11/12)

CB200W Water Leak Detection Panel Application Guide

HM-W536 Install Guide

4007ES Fire Control Panels

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Release Control Fire Alarm Systems

TrueAlarm Fire Alarm Systems

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM S7010 S :111

CATALOG NUMBER. Features. Description

LifeAlarm Fire Alarm Controls

SECTION DETECTION AND ALARM

Fire Alarm System Accessories

C. Conform to requirements of Americans with Disabilities Act (ADA).

INSTALLATION INSTRUCTIONS

4100U/4100ES to TFX Fire Fighter Phone System Installation Instructions

INTELLIGENT FIRE ALARM CONTROL UNITS MMX-MNS TM

PK5500 v1.1 Installation Instructions

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

FIREDEX Conventional Fire Panels

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Control Panels D9412GV3/D7412GV3/D7212GV3. UL Installation Instructions

Repeaters and Mimics Data Sheet

ECC-50/100(E) Emergency Command Center

NETWORK FIRE ALARM CONTROL PANEL. Features S7010 S :111

SECTION FIRE ALARM AND DETECTION SYSTEMS

SAFEPATH 4 Facility Communications System & Expansion Options

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Fire Alarm System Plans Submittal Guidelines For New and Existing Systems

Small Building Life Safety Solutions. GE Security. Affordable FireShield Conventional Fire Alarm Control Panels. imagination at work

Fire Alarm System Plans Review Checklist Property location Date of Review

Fire Pump Controllers Remote Alarm Panels

CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS

FIRE ALARM PANEL & SYSTEM OPERATION ID50 SYSTEM. The Fire Alarm System can be activated in the following ways :~

FA-300 Series. LCD Fire Alarm Control Panel. User Guide. LT-954 Rev. 0.1 February FA-300 SERIES Fire Alarm Control Panel

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

SECTION FIRE ALARM AND DETECTION SYSTEM

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

FIRERAY 2000 Installation Guide

DUCT SMOKE DETECTOR D4120

PowerLogic Sub Meter Display (SMD and SMDOPN)

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Owner s Manual AWM910 JENSEN AWM910 COMPACT DISC PLAYER RADIO CD COMPACT MUSIC SYSTEM MUTE AUX BAND AUX IN PUSH PUSH PWR VOL ALARM T/F AUD SPK A SPK B

DIVISION 28 ELECTRONIC SAFETY AND SECURITY SECTION SECURITY AND ACCESS CONTROL SYSTEM

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

INTRUSION DETECTION SYSTEM Section

BARDIC. 4 & 8 Zone Fire Panels Zircon range. Data, installation, operation and maintenance. by Honeywell

DELAWARE STATE FIRE MARSHAL FIRE ALARM SYSTEM CERTIFICATE OF INSTALLATION

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert AC4. User Manual

SECTION FIRE DETECTION AND ALARM SYSTEM PART 1 - GENERAL 1.01 DESCRIPTION

FLORIDA ATLANTIC UNIVERSITY FIRE ALARM SYSTEM INSTALLATION MANUAL

Conventional Fire Detection and Extinguishant Control System Specification

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

4005 Fire Alarm Front Panel Programming Instructions

SECTION FIRE ALARM SYSTEM

FIRE ALARM AND EMERGENCY VOICE EVACUATION SYSTEM

Gen4 Intruder Alarm Panels SIMPLY SECURE. For Residential & Small Commercial Applications

HERNANDO COUNTY FIRE ALARM GUIDELINES

FVSU REPAIR & UPGRADE FIBER OPTIC SECTION FIRE ALARM SYSTEM CONNECTIVITY

Applied Electronics. Commercial Dimming System UPDATE NOTICE

HMI display Installation Guide

SD Rack. DiGiCo SD Rack. User Manual B - August

Residential Gateway (RG) Battery Backup

4-Wire Air Duct Smoke Detector. Protection Systems. A UTC Fire & Security Company. Models DH-60 FEATURES APPLICATION DESCRIPTION SAMPLING TUBES

3500/93 System Display

DTW Works Master Specification Version 2006

ADT-LCD40 Series Remote Fire Annunciators

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected

Original Document 10/16/07 Revised 01/30/09 2 nd Revision rd Revision- 12/18/14

CLARK COUNTY FIRE DEPARTMENT Fire Hazard & Prevention Services

UniOP epad33 and epad33t

ARCHITECT AND ENGINEER SPECIFICATION SECTION DETECTION AND ALARM SECURITY ACCESS AND SURVEILLANCE. DSC MAXSYS PC4020 V3.

TAMARAC FIRE RESCUE INSTRUCTIONS FOR FIRE ALARM PRE-SUBMITTAL CHECKLIST

GSM Autodialer Professional GJD700 Speech & Text Autodialer

AIS750 Series Alarm Annunciator

SMS GSM Alarm Messenger

HP UPS R1500 Generation 3

GSM Alarm System User Manual

EQUIPMENT SPECIFICATIONS

Operating the DS9400 Fire Alarm Control/Communicator

SECTION FIRE ALARM AND DETECTION SYSTEM

FC18 Controller(Interlocking) Product Manual

COMPALARM AP GENERAL MAIN FEATURES

Transcription:

Emergency Operating Instructions Fire Alarm S Priority 2 Alarm Fire Alarm Priority 2 Ack Ack How Acknowledge / View Events Press ACK located under flashing indicar. Repeat operation until all events are acknowledged. Local ne will silence. System Supervisory System Trouble Supv Trouble Ack Ack WARNINGS Alarm or Warning Condition System indicar flashing. Tone. How Silence Building Signals Press Alarm Silence. Alarm Silenced Alarm Silence AC Power System Reset Page Up Previous Next Page Dn How Reset System Press System Reset. Press Ack silence ne device. A B C D E F G H I ZONE 1 J K L M N O P Q R FB 4 S T U V W X Y Z / P 7 'SP' ( ), # : NET Menu SIG AUX 2 3 IO 5 A 8 IDNet 6 L 9 ADDR 0 C/Exit Enter Fire Panels UL, ULC, CSFM Listed; FM Approved; MEA (NYC) Acceptance* Features Remote Annunciar Panels provide fire alarm control panel status information at locations distant from the fire alarm control panel Typical functions include: Remote status LED indicars and dedicated switch input controls located on LED/switch modules Remote status LED indicar modules with 8 red or 16 (8 red/8 yellow) that are pluggable allow color selection (yellow, green, or red are ordered separately) Remote microphone and operar interface for access the emergency voice/alarm communications system Remote master telephone for communicating the firefighter telephone system Also available with InfoAlarm expanded content user interface (refer page 5 and data sheet S4100-0045 for additional information) Additional optional modules include: Remote module for LCD status readout and keyswitch controlled functions 24 Point I/O module RS-232 ports for remote printer or terminal connections Power supplies with battery charger for annunciar Panel mounted printer for system status recording Wiring requirements: RUI or RUI+ (remote unit interface) supervised communications from the host fire alarm control panel provide Style 4 or Style 7 SLC (signaling line circuit) connections Microphone and telephone circuits require their own dedicated wiring Listed : UL Std. 864, Fire Detection and (UOJZ), and Smoke Service (UUKL) UL Std. 2017, Process Management Equipment (QVAX) UL Std. 1076, Proprietary Alarm Units-Burglar (APOU) UL Std. 1730, Smoke Detecr Monir (UULH) ULC Std. S527-99 * See page 4 for additional listing details. This product has been approved by the California State Fire Marshal (CSFM) pursuant Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7165-0026:0251 for allowable values and/or conditions concerning material presented in this document. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. 4100ES Remote Annunciar in a Three Bay Cabinet with Operar Modules; Remote (left) and with an InfoAlarm (right) Introduction Remote Annunciar Panels Remote Annunciar Panels are dedicated purpose transponders that support fire alarm system status information. Typical use is when the host fire alarm control panel is located away from the area where those responding a fire situation need status information. Status and. s are suitable for firefighter or other fire brigade responders access particular information and for system control. When equipped with a remote microphone and emergency voice/alarm communications system control, an authorized user can take command of the system and either play selected pre-recorded messages or select specific nes, or initiate live broadcast information either globally in the system, or selected areas. Remote Master Firefighter. When equipped with a remote master phone, the authorized user can connect remote phone call-in requests and allow callers be connected each other. Although intended for use in assisting fire responders, these system are also helpful during system setup and test. S4100-0038-13 6/2013

Module Bay Description Remote Annunciars include a bay assembly, a power distribution interface module (PDI), a Transponder Interface Module, and an interconnect harness. Communications with the host fire alarm control panel are via a Remote Unit Interface (RUI or RUI+) connection that allows for up 2500 ft (762 m) distance. RUI can communicate with up a tal of 31 remote devices per master controller (on one or multiple RUI channels) and can be either Style 4 or Style 7 communications. Wiring can be either shielded or unshielded, twisted, or untwisted single pair wiring. 4100-9610 Remote Annunciar. This model is for applications that may require a full complement of the Remote Annunciar functions (refer the product selection lists on pages 3 and 4). Power is from a cabinet mounted Remote Power Supply (RPS). 4100-9611 Basic Remote Annunciar. For remote annunciar applications that require less features in the cabinet, select this model which accepts power from a separate fire alarm control cabinet. (This model does NOT accept: a cabinet mounted power supply, expansion phone cards, Class A phone modules, RS-232 modules, panel mounted printers, or 24 I/O modules.) Optional Expansion Bays each include a PDI and accept a variety of optional modules for specific annunciar functions. The Battery Compartment (botm) accepts two batteries, up 50 Ah. Battery mounting does not interfere with available module space. (Not applicable the model 4100-9611) Remote Annunciar Module Reference Packaging Availability Modules are power-limited (except as noted, such as relay modules) Enclosure are available for one, two, or three bay sizes or for cabinet rack mounting Boxes, doors with tempered glass inserts, and dress panels are available in beige or red (ordered separately) Refer document S4100-0037 for enclosure details Remote The optional Remote occupies the p bay of a Remote Annunciar. It provides an LCD status readout with keyswitch activated control switches and a local ne-alert sounder. Features are essentially identical the Remote LCD Annunciar model 4603-9101 (reference document S4603-0001). REMOTE COMMAND CENTER Emergency Operating Instructions FIRE ACK PRIORITY 2 ACK SYSTEM SUPERVISORY SUPV ACK SYSTEM TROUBLE TBL ACK Alarm or Warning Condition System indicar flashing. Tone. How Acknowledge / View Events Press ACK located under flashing indicar. Repeat operation until all events are acknowledged. Local ne will silence. POWER ON SILENCED SILENCE 4100-1292 Remote DISPLAY TIME SYSTEM RESET How Silence Building Signals Press Alarm Silence. How Reset System Press System Reset. Press Ack silence ne device. Circuits Circuit 1 Circuit 9 8th Circuit 2 Circuit 10 7th Circuit 3 Circuit 11 6th Push-- switch Circuit 4 Circuit 12 5th Circuit 5 Circuit 13 4th Circuit 6 Circuit 14 3rd Circuit 7 Circuit 15 2nd Circuit 8 Circuit 16 1st Remote Master Module 4100-1271 8 Switches with 8 Red, 4100-1280, 2 shown with typical labels Remote Microphone Module 4100-1244 Single Channel 4100-1252 8 Switches with 8 Red, 4100-1280 2 S4100-0038-13 6/2013

Product Selection Panel Type Model Description Details and Mounting Reference 4100-9610 4100-9611 Remote Annunciar Panel; requires an internal power supply Basic Remote Annunciar Panel; requires power from another cabinet (refer module exclusion list on page 2) Includes a bay assembly with power distribution board, a Basic Transponder Interface Module (4100-0620) mounted in Block A, and an interconnect harness for connecting 4100ES/4100U Slot modules Supervisory and Alarm current = 87 ma Includes a bay assembly with power distribution board, a remotely powered Transponder Interface Module mounted in Block A, and an interconnect harness for connecting 4100ES/4100U Slot modules Supervisory and Alarm current = 87 ma Remote Option (for InfoAlarm expanded content display products, refer data sheet S4100-0045) Model Description Details and Mounting Reference 4100-1292 Panel Mounted LCD Annunciar; 2 line by 40 character LCD with LED illumination; LED illumination is off during supervisory, turning on with alarm or when switches are activated Mounting requires the p bay; 4100ES/4100U flat modules are allowed behind it; RUI device, RUI/RUI+ connection is required Supervisory current = 65 ma (w/o backlight) Alarm current = 140 ma Emergency Voice/Alarm Communications Operar Interface Options Model Description Details and Mounting Reference 4100-1244 Remote Microphone (mike) Module Front panel module; requires 2 Slots (4 [51 mm]), space behind accepts 4100ES/4100U flat modules only (requires dedicated wiring fire alarm control panel audio control module); Supv. = 2.4 ma, = 6 ma 4100-1252 1 Channel (audio or mike) Single slot modules requiring connection an LED/switch controller; space 4100-1253 1.5 Channel (audio + mike) Operar behind accepts 4100ES/4100U flat modules only; adjacent LED/switch Interface module(s) are required for specific speaker circuit selection (refer 4100-1254 2 Channel (full audio) Modules document S4100-0034 for audio reference and document S4100-0032 for 4100-1255 3-8 Channel LED/switch module reference); Supv. = 0, Alarm = 24 ma Firefighter Telephone System Products (refer document S4100-0034 for additional detail) Model Description Details and Mounting Reference 4100-1271 Remote Master Telephone Mounts in two vertical blocks of bay front, locate as required; space behind allows 4100ES/4100U flat modules only 4100-1272 Module with 3 Class B phone NACs Single Block module, mounts bay mounting plate Not available 4100-1273 Class A Adapter Module Mounts 4100-1272, no additional space required with 4100-9611 LED and LED/Switch Modules, General Purpose (LED/switch controller and label kit is ordered separately)* per Switch Switches Model LED Color(s) Model LED Color(s) e 8 8 4100-1280 Red 4100-1281 Yellow Two 16 8 4100-1282 Red on p, Yellow on botm 4100-1283 Yellow, p and botm Two 16 8 4100-1284 Red on p, on botm 4100-1296 on p, Yellow on botm e 16 16 4100-1285 Red 4100-1278 8 Red on left, 8 Yellow on right per Switch Switches Model LED Color(s) only 8 only 4100-1276 Red, pluggable only 16 only 4100-1277 Pluggable, shipped Red on p, Yellow on botm e 16 16 4100-1300 Pluggable, shipped Red on p, Yellow on botm; Note: UL, ULC, and CSFM listed only e 24 24 4100-1287 Red LED/Switch Modules, Special Purpose (LED/switch controller, label kit, and separate are ordered separately)* Model Operation Switch Function (Location) LED Description 4100-1286 (p) LED Eight function HOA (,, ) Module (middle) Red LED with labeled switches (botm) LED 4100-1295 Eight function HOA (,, ) Module, same as 4100-1286 except switches are unlabeled LED/Switch ler Modules and Accessories (LED kits for 4100-1276/1277/1300 are on page 4)* Model 4100-1288 4100-1289 Description 64 LED/64 Switch ler Module with mounting plate; controls up 64 and interfaces up 64 switches; mounts behind the LED/switch modules and has provisions for one 4100-1289 ler Module 64 LED/64 Switch ler Module without mounting plate; mounts on extra space of 4100-1288; controls an additional 64 and 64 switches NOTE: LED/switch controllers and their connected LED/switch modules must be in the same bay; (see data sheet S4100-0032 for details) 4100-1294 LED/Switch Module Slide-in Labels, required when LED/switch modules are present; order one per cabinet 4100-1290 24 Point I/O Module for external connections, select each point as either input or output; 2 (51 mm) wide, 1 Slot; refer S4100-0032 for more detail; not available with 4100-9611 * Note: Refer data sheet S4100-0032 for additional LED/Switch module selections. (continued) 3 S4100-0038-13 6/2013

Product Selection (Continued) Communication Modules (not available with 4100-9611) Model Description Size Supv. Alarm 4100-6038 Dual RS-232 Interface, mounts in Slot 3 or Slot 2 1 Slot 132 ma 132 ma 4100-9816 Master Clock Interface Module with one standard RS-232 port (see S4100-0033) 1 Slot 132 ma 132 ma Panel Mounted Printer (not available with 4100-9611, refer document S4100-0032 for additional detail) Model Description 4100-1293 Panel Mount Thermal Printhead Printer, supplied with one roll of paper; requires 3 expansion slots 4190-9803 Replacement Paper for 4100-1293 Printer, one roll Power Supplies and Accessories Model Voltage/Listing Description Size Supv. Alarm 4100-5125 120 VAC UL Remote Power Supply (RPS); 9 A power supply 4100-5126 120 VAC, Canadian ULC with battery charger; Canadian model has low battery cuut; required for 4100-9610, not 4100-5127 220/230/240 VAC UL available with 4100-9611 4100-0636 4 Blocks 150 ma 185 ma Box Interconnection Harness Kit; order one for each close-nippled cabinet; also used if power is supplied from host fire alarm control panel Power Distribution Modules Model Voltage Description 4100-0634 4100-0635 120 VAC 220/230/240 VAC Power Distribution Module (PDM); select per system voltage Miscellaneous Accessories Required for 4100-9610, select one per box or cabinet rack; not applicable for 4100-9611 Model Description 4100-2300 Expansion Bay Hardware, order one for each expansion bay (unless included with selected option) 4100-1279 Single blank 2 display cover, order as required (8 fill a bay front); 2 max. between LED/switch modules 4100-9835 Termination and Address Label Kit (for module marking); provides additional labels for field installed modules 4100-0632 Terminal Block Utility Module; provides 2, 16 position terminal blocks mounted on 4 x 5 single block size, capable of up 12 AWG wire (3.31 mm 2 ) 4100-0633 Door Tamper Switch (connects Transponder Interface Module) 4100-9843 Yellow 4100-9844 4100-9845 Red General Specifications Input Power Kits of 8 ; order as required for 4100-1276/1277/1300 modules Remote Power Supplies (RPS) 120 VAC Models 4 A maximum @ 102 132 VAC, 60 Hz 220-240 VAC Models 2 A maximum @ 204 264 VAC, 50/60 Hz; separate taps for 220/230/240 VAC Power Supply Output Ratings for the Remote Power Supply (RPS) Total Power Supply Output Rating Auxiliary Power Tap NACs Programmed for Auxiliary Power 9 A tal @ nominal 28 VDC, including module currents and auxiliary power outputs 2 A maximum 2 A maximum per NAC, 5 A maximum tal Battery Charger, Remote Power Supply (RPS) (sealed lead-acid batteries) Battery capacity range Charger characteristics and performance Environmental Rated 19.1 31.1 VDC Output switches battery backup during mains AC failure or brownout conditions UL listed for battery charging of 6.2 Ah up 110 Ah (batteries larger than 50 Ah require a remote battery cabinet); ULC listed for charging up 50 Ah batteries Temperature compensated, dual rate, recharges depleted batteries within 48 hours per UL Standard 864, 70% capacity in 12 hours per ULC Standard S527 Operating Temperature Range 32 120 F (0 49 C) Operating Humidity Range Up 93% RH, non-condensing @ 90 F (32 C) maximum 4 S4100-0038-13 6/2013

5 S4100-0038-13 6/2013 Fire Zones Fan Fan HVAC s HVAC s Door Release Manual Alarms Smoke Alarms Two Bay Remote Annunciar LED/Switch Module Reference InfoAlarm Detail Reference

Single Slot LED/Switch Module Detail Reference LED/Switch Modules Label insert Primary function label LED Modules Additional function labels Switches Cusm label area Fan Fan Designates area for each column of switches and Visible area 8-1/4" H, 2" W (210 mm x 51 mm) Switch LED Color Legend: Red, Yellow, ; R/Y = Red on p, Yellow on botm; R-Y = Red on left, Yellow on right 8 Switches with 16 : 4100-1282, R/Y 4100-1283, Y/Y 4100-1284, R/G 4100-1296, G/Y 16 Switches with 16 : 4100-1300, R/Y (pluggable ) 8 Switches with 8 : 4100-1280, R 4100-1281, Y 16 Switches with 16 : 4100-1278, R-Y 4100-1285, R 8 : 4100-1276, R (pluggable ) 16 : 4100-1277, R/Y (pluggable ) Dual Slot LED/Switch Module Detail Reference Label insert e switch per control, on/off Primary function labels Cusm label area LED () Red LED () LED () Red Visible area 8 1/4" H, 2" W (210 mm x 51 mm) e switch per function 4100-1287 24 Switches, 24 HOA Modules, 8 s (3 switches each), 24 : 4100-1286, with labeled switches (shown) 4100-1295, with unlabeled switches (not shown) 6 S4100-0038-13 6/2013

Module Detail 4100-1252, Single Channel 4100-1253, 1.5 Channel 4100-1254, Dual Channel 4100-1255, 3-8 Channel LED LED LED LED Visible area 8-1/4" H, 2" W (210 mm x 51 mm) Red Alert Red Alert Red Start Selected Red Local Local Local Local Alert Expansion Bay Module Loading Reference Blank switches can be programmed as required Slot 1 Slot 2 Slot 3 Slot 4 Slot 5 Slot 6 Slot 7 Slot 8 Block A Block C Block E Block G Size Definitions: Block = 4 W x 5 H card area Slot = 2 W x 8 H motherboard with daughter card Block B Block D Block F Block H Expansion Bay Chassis Additional 4100ES Data Sheet Reference Subject Data Sheet Subject Data Sheet 4100ES Panels S4100-0100 LED/Switch Modules S4100-0032 InfoAlarm With EPS S4100-0101 4100ES Basic Panel Modules S4100-0031 Power Network Display Unit (NDU) Supplies S4100-0102 MINIPLEX Transponders S4100-0035 MINIPLEX Transponders S4100-0103 Network Display Unit (NDU) S4100-0036 Enclosures S4100-0037 Remote Battery Charger S4081-0002 4100ES/4100U / Modules S4100-0034 7 S4100-0038-13 6/2013

Wall Mounted Enclosure Installation Reference Front view, box outline without door Side view with door attached 3 Bay height = 56" (1422 mm) Door thickness 4-3/4"(121 mm) Knockout screw/nail holes (for semi-flush mounting) 2 Bay height = 40" (1016 mm) Exposed cabinet for semi-flush mounting 1-3/8" (35 mm) minimum Wall board reference for semi-flush mounting, 6" stud 1 Bay height = 22" (559 mm) Doors can be hinged left or right Exposed door and cabinet for semi-flush mounting 6-1/8" (156 mm) minimum Optional semi-flush trim kit reference Stud alignment markers, each side 6" stud 4" stud 24" (610 mm) 6-29/32" (175 mm) 11-11/16" (296 mm) NOTE: A system ground must be provided for Earth Detection and transient protection devices. This connection shall be made an approved, dedicated Earth connection per NFPA 70, Article 250, and NFPA 780. TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. Tyco Fire Protection Products minster, MA 01441-0001 USA S4100-0038-13 6/2013 www.simplexgrinnell.com 2013 Tyco Fire Protection Products. rights reserved. specifications and other information shown were current as of document revision date and are subject change without notice.