APS Performance Testers APS Time Verification MP159x Network Performance Tester



Similar documents
A Brief Overview of SONET Technology

SDH and WDM: a look at the physical layer

SDH and WDM A look at the physical layer

Quick installation guide for the Vista Quantum QNVR Network Video Recorder

Application Note. Line Card Redundancy Design With the XRT83SL38 T1/E1 SH/LH LIU ICs

T-BERD 107A. T-Carrier Analyzer

Practice Fusion API Client Installation Guide for Windows

MPLS Layer 2 VPNs Functional and Performance Testing Sample Test Plans

MULTIPRON. E1, Gigabit Ethernet, RS232/485 Tester MULTIPRON

DS-3 Technology and Testing Overview

Course 12 Synchronous transmission multiplexing systems used in digital telephone networks

Setting Alarms and Inserting Errors

It explains the differences between the Plesiochronous Digital Hierarchy and the Synchronous Digital Hierarchy.

Wireless DMX Connector

Raj Jain. The Ohio State University Columbus, OH These slides are available on-line at:

10 Gigabit Ethernet WAN PHY

Clocking. Clocking in the Digital Network

IP Office Technical Tip

How To Test A Ds1 Signal

TAN-030 Application Note Performance Characteristics of the XRT7300 Device for DS3 Applications Rev. 1.00

Interfaces and Payload Testing

Making Ethernet Over SONET Fit a Transport Network Operations Model

FIBER OPTIC COMMUNICATIONS. Optical Fibers

PXI. GSM/EDGE Measurement Suite

Power Amplifier Gain Compression Measurements

TCOM 370 NOTES 99-6 VOICE DIGITIZATION AND VOICE/DATA INTEGRATION

Monitoring and Testing

DigiPoints Volume 1. Student Workbook. Module 5 Growing Capacity Through Technology

Appendix A. CMS(Client Management Software)

LADDER LOGIC/ FLOWCHART PROGRAMMING DIFFERENCES AND EXAMPLES

Department of Electrical and Computer Engineering Ben-Gurion University of the Negev. LAB 1 - Introduction to USRP

Modultech MT-XDFx-xx192-08(04)CD 80 (40) km DWDM XFP module with built-in FEC wrapper Description

2-port STM-1/OC-3 Channelized E1/T1 Line Card for Cisco Series Internet Routers

Software Manual RS232 Laser Merge Module. Document # SU Rev A

Gigabit Ethernet Turn-up Procedure using the JDSU T-BERD 8000 or T-BERD 6000A March 4, 2009

For T1 / E1, an NT NeTwork device must be connected to a TE Terminal Equipment device; NT must connect to TE.

GAMATRONIC ELECTRONIC INDUSTRIES LTD.

Communications Analyzer

Configuring the ADTRAN ATLAS for a Rabbit-Hole Application

FURTHER READING: As a preview for further reading, the following reference has been provided from the pages of the book below:

Fundamentals of SONET/SDH

Cisco 2-Port and 4-Port OC-3c/STM-1c POS Shared Port Adapters

Clearing the Way for VoIP

DS Wire Digital Thermometer and Thermostat

Logging of RF Power Measurements

SMS GSM Alarm Messenger

WaveReady CFM. Optical Link Monitoring System: Continuous Fiber Monitor

INSIDE. Preventing Data Loss. > Disaster Recovery Types and Categories. > Disaster Recovery Site Types. > Disaster Recovery Procedure Lists

DS1621 Digital Thermometer and Thermostat

T3 Mux M13 Multiplexer

81110A Pulse Pattern Generator Simulating Distorted Signals for Tolerance Testing

LAN extensions for Instrumentation

DS1621 Digital Thermometer and Thermostat

Trinity Feature: T1/E1 Configuration

APPENDIX. SureSERVO QUICK START GUIDE. In This Appendix... Quick Start for SureServo Drives...A 2. Tuning Quick Start for SureServo Drives...

Performance Management and Fault Management. 1 Dept. of ECE, SRM University

E21 Mobile Users Guide

End-to-end GMPLS based Protection & Restoration on new generation router interface (Integrating Optical Transport into Router)

M7 Modem Application Note. Smart Carrier Cancelling Quick Start Guide

OptiView. Total integration Total control Total Network SuperVision. Network Analysis Solution. No one knows the value of an

Analyzing Full-Duplex Networks

- T-Carrier Technologies -

OptiView. Total integration Total control Total Network SuperVision. Network Analysis Solution. No one knows the value of an

Automation Engine 14. Troubleshooting

Instructions for Setting the T560 Digital Delay Generator for the Target Delay

Fiber Optic Communications Educational Toolkit

Advantech WebAccess Device Driver Guide. BwSNMP Advantech WebAccess to SNMP Agent (Simple Network Management Protocol) Device Driver Guide

CHAPTER 11: Flip Flops

Wide Area Monitoring, Control, and Protection

Synchronous Optical Network (SONET)

IxNetwork TM MPLS-TP Emulation

For more information on the configuration of Praesideo, CobraNet and PC CST check the Praesideo IUI.

Shadow TX(A) Shadow RX

3D Input Format Requirements for DLP Projectors using the new DDP4421/DDP4422 System Controller ASIC. Version 1.3, March 2 nd 2012

A quick user guide for your LX Apollo DVR

DE4 NetFPGA Packet Generator Design User Guide

SNMP Network Node Manager (NNM) Setup Guide

Design and Verification of Nine port Network Router

1+1 PROTECTION WITHOUT RELAYS USING IDT82V2044/48/48L & IDT82V2054/58/58L HITLESS PROTECTION SWITCHING

Agilent GSM/EDGE Base Station Test with the E4406A VSA and ESG-D Series RF Signal Generators Product Overview

The Effect of Network Cabling on Bit Error Rate Performance. By Paul Kish NORDX/CDT

Dialogic MSP 1010 Multi-Services Platform Enables Non-Intrusive SS7 Signaling Monitoring

Contents. 1.2 Software Installation... 1

ANT-20, ANT-20E Advanced Network Tester PDH MUX/DEMUX

ImagineWorldClient Client Management Software. User s Manual. (Revision-2)

Network administrators must be aware that delay exists, and then design their network to bring end-to-end delay within acceptable limits.

10G LAN PHY over G.709 OTN: A Service Provider Prospective

APPLICATION CASE OF THE END-TO-END RELAY TESTING USING GPS-SYNCHRONIZED SECONDARY INJECTION IN COMMUNICATION BASED PROTECTION SCHEMES

Free 15-day trial. Signata Waveform Viewer Datasheet

Cisco T1 Layer 1 Troubleshooting

Timer A (0 and 1) and PWM EE3376

IPEmotion CAN Bus Traffic Recording, Analysis, Generation PM (V2.3)

WRE6505. User s Guide. Quick Start Guide. Wireless AC750 Range Extender. Default Login Details. Version 1.00 Edition 1,

Application Performance Analysis and Troubleshooting

Chapter 4 T1 Interface Card

Quick Start Using DASYLab with your Measurement Computing USB device

Transcription:

Application Note APS Performance Testers APS Time Verification MP159x Network Performance Tester Introduction This application note demonstrates the Time Verification feature of the Automatic Protection Switch (APS) available on many of Anritsu s network performance testers. This document, written in the context of an MP159x customer demonstration, walks the user through test setup, configuration and execution. Many other products time verification features break down switch times into 10 to 100 milliseconds, as does Anritsu s MP159x, but Anritsu s feature also supports a switch time error free period of one millisecond. This unique test capability allows service providers and network equipment manufacturers to characterize and validate the correct APS operation and function of their network equipment quickly and easily. This application note s instructions apply to the entire family of MP159x products MP1590B, MP1591A and MP1595A that address the complete range of SONET/SDH and OTN rates and testing environments. The unique strengths found only in the MP159x APS Performance Tester include: Millisecond switch time resolution for all supported bit rates (1.5 Mb to 40Gb). Error free period from 1 ms to 100 ms. Log switch times in report format for up to 50 switches. The ability to execute APS performance switch measurements for all mapped channels (background and foreground). Time Verification Time verification can be described as a measurement during a period of time during an event. A time verification feature measures and records these events. It validates path delays (primary input or storage element to primary output or storage element) to ensure that they are not too long, and checks clock pulses to ensure that they are not too wide or narrow.

1. TEST SETUP. Testing provided an in-depth analysis of this test solution as seen through the customer s eyes. Anritsu MP159x demonstrated the tester s ability to verify APS features without requiring additional third party devices such as scopes and/or additional test equipment. RX Anritsu MP1590B Network Performance Analyzer TX OC-12 RX STS-1-v Network Equipment 1x8 Protection Scheme TX FIGURE 1. Possible 5500 APS test solution for network equipment manufacturer. 2. TEST CONFIGURATION. The Anritsu MP159x configuration corresponds to the existing SONET cross-connection configuration used in the demonstration. During the demonstration, Anritsu s engineers communicated the following information: The feature eliminates the time and effort required to re-provision a network equipment manufacturer s device. Measurement starts when the selected error or alarm trigger detection occurs. It ends when the target trigger is not detected for longer than the time specified in the Error Free Period. Bit Error is selected as the alarm trigger, allowing for any received error to trigger the beginning of the APS measurement time. In order to generate the bit error required to begin APS measurement, the MP159x transmits LOF for one second. However, any bit error received begins the measurement. FIGURE 2. Visual representation of Anritsu s APS feature.

FIGURE 3. APS test interface on MP 159X. 3. TEXT EXECUTION. The demonstration verified feature functionality within a network environment utilizing the MP159x. The testing was conducted for demonstration purposes only and was not based upon documented vendor requirements of TL9001 standards. The MP159x transmitted an LOF (Loss of Frame) alarm for one second, triggering the start of the APS measurement. The alarm was identified and recorded in the SONET Error/Results screen. FIGURE 4. Alarm results on interface screen.

The recorded measurement switch time reflected the length of the alarm received after subtracting the error free period. In this case, the alarm lasted for one second, plus the amount of time to receive a clean signal. FIGURE 5. APS Results Window. Since the demonstration was performed on a loopback signal, the switch time recorded was very close to the LOF generation. A table of the collected samples was available for comparison and analysis as additional samples were recorded. FIGURE 6. APS analysis screen. The user s results were available on one screen for real-time access and for the tester s convenience.

FIGURE 7. Summary of all previous screens. Conclusion Anritsu s time verification feature breaks down switch times into seconds or microseconds, allowing service providers and network equipment manufacturers to characterize and validate the correct APS (Automatic Protection Switch) operation and function of their network equipment quickly and easily. Other strengths of this product include: error free period from 1 ms to 100 ms; log switch times in report format for up to 50 switches and the ability to execute APS performance switch measurements for all mapped channels (background and foreground). This application note explains the necessary steps to demonstrate the entire family of Anritsu s MP159x APS network performance testers. It walks the user through test setup, configuration and execution.

Anritsu APS Performance Testers (APS Time Verification) Applications_2087-0312