Real-Time DPM Ambient Monitoring in Underground Mines



Similar documents
Near Real-time Monitoring of Diesel Exhaust Particulate (DEP)

6 Crankcase Ventilation

Using Carbon Dioxide as a Tracer Gas to Measure Air Change Rate in a Single Zone

TSI BIOTRAK REAL-TIME VIABLE PARTICLE COUNTER FACILITY MONITORING SYSTEMS

REAL-TIME DUST AND AEROSOL MONITORING

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

ENVIRONMENTAL MONITORING / TESTING TO CONFORM WITH ISO14644 & TGA GMP REQUIREMENTS

WERRIS CREEK COAL PRP U1: MONITORING RESULTS WHEEL GENERATED DUST

How To Calculate Dust Concentration In A Mine

PROPOSED RESIDENTIAL DEVELOPMENT LAND OFF MACCLESFIELD OLD ROAD, BUXTON. Construction Management Plan

UK Air Quality Monitoring Networks

Air Pollution Control Division. Technical Services Program

Calculations and OELs

Coarse PM Methods Evaluation Study

SPECIAL APPLICATIONS

MAC-ENC-PRO-057 AIR QUALITY MONITORING PROGRAM

DOE-HDBK Module 2.18 Air Sampling Equipment. Instructor s Guide

Current and Future Methods for Calibration of Black Carbon Real-Time Mass Instruments

Innovative solutions for better. health protection. Thermo Scientific Aerosol and Dust Monitoring Solutions

National Heavy Vehicle Accreditation Scheme: Standards and Business Rules - Maintenance Management standards

Class II Type B2 Laminar Flow Biological Safety Cabinets at Ordering Criteria for the National Institutes of Health

VALIDATION, MODELING, AND SCALE-UP OF CHEMICAL LOOPING COMBUSTION WITH OXYGEN UNCOUPLING

VISIBLE EMISSIONS TRAINING AND CERTIFICATION PROGRAM EVALUATION FORM

Testing of particulate emissions from positive ignition vehicles with direct fuel injection system. Technical Report

THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS

How To Design A Gas Dryer

An overview of Euro VI for trucks over 3.5t. Brought to you by Mercedes-Benz

POLLUTED EMISSION TREATMENTS FROM INCINERATOR GASES

Aggregate Handling And Storage Piles General

Direct Fresh Air Free Cooling of Data Centres

How To Reduce Noise From A Test Screen


HEPA FILTER DEFECTS ARE COMMON

Diesel Fuel Additive Heavy Duty Applications. December 2011

Principles of Ventilation. Patrick N. Breysse, PhD, CIH Peter S.J. Lees, PhD, CIH Johns Hopkins University

The Introduction of Euro 5 and Euro 6 Emissions Regulations for Light Passenger and Commercial Vehicles

HVAC Systems and Indoor Air Quality. Douglas K. Spratt, M.Sc., P.Eng.

SEPARATING DUST PARTICLES USING AN AERODYNAMIC DEDUSTER

FINE PARTICLE EMISSION PROFILE FOR ROAD DUST IN PITTSBURGH, PENNSYLVANIA

Industrial Ventilation Design Guidebook Chapter 10 LOCAL VENTILATION

PANDA SPRAY BOOTH FILTER INFORMATION

Analysis of Energy Consumption, Rating Score, and House Size

A Report of Air Sampling for Mercury Vapor and Particulates During Fluorescent Tubes Disposal Operation Maywood, Illinois Survey date: 9/28/2000

ECO Stars Fleet Recognition Scheme Improving Local Air Quality Through Operator Engagement

Recommended Practice for Installation of Transit Vehicle Fire Protection Systems

How To Test Aerify

S300 Series Dust Monitors

CHAPTER 6 INSTRUMENTATION AND MEASUREMENTS 6.1 MEASUREMENTS

Exhaust Scrubbers. What you need to know. Move Forward with Confidence

RECEPTOR MODELS FOR PARTICULATE MATTER MANAGEMENT. K. Eleftheriadis N.C.S.R. Demokritos

Electric Utilities and Water: Emerging Issues and R&D Needs

PREFAULT MONITOR FOR AIR COOLED GENERATORS

TÜV RHEINLAND ENERGIE UND UMWELT GMBH

Ozone Generator Manual

Control Device Requirements Charts For Oil and Gas Handling and Production Facilities

IMPLEMENTING ISO 14001:

Carbon Management Plan

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

Energy Options in a Carbon Constrained World. Martin Sevior, School of Physics, University of Melbourne

Robert McCabe Director, Health Care Solutions HTS Chicago. Improved Air Quality and Energy Efficiency through Air Handler Filtration System Upgrade

Estimated emissions and CO2 savings deriving from adoption of in-place recycling techniques for road pavements

Online Infrared Flue Gas Analyzer Gasboard 3000

1.0 What Are the Purpose and Applicability of Performance Specification 11?

Scope 1 describes direct greenhouse gas emissions from sources that are owned by or under the direct control of the reporting entity;

Exposure and Control of Ten High Priority MSHA Contaminants in Metal Mines. Presented by: Shannon E. Newton, MPH, CIH

Particle Monitoring Requirements in Pharmaceutical Cleanrooms

Guidelines for the Estimation and Reporting of Australian Black Coal Resources and Reserves

Visualisation and control of solder fume exposure

COAL MINING SAFETY AND HEALTH REGULATION 2001

Measurement of particle concentrations in Piacenza urban area: Ambient air levels and personal exposure concentrations

M20. Technical Guidance Note (Monitoring) Quality assurance of continuous emission monitoring systems - application of EN and BS EN

User checks and maintenance of laboratory balances

Performance Standards and Test Procedures for Automated Dust Arrestment-Plant Monitors

DEVELOPMENT OF AN ENHANCED PROTECTION POSITIVE PRESSURE RESPIRATOR (E3PR) PROTOTYPE CANISTER

Hazard Identification and Risk Assessment for the Use of Booster Fans in Underground Coal Mines

GUIDELINE FOR THE INSTALLATION AND OPERATION OF CONTINUOUS EMISSION MONITORING SYSTEMS (CEMS) AND THEIR USE FOR REPORTING UNDER THE PROVISIONS OF

PTE/16/29. Place Scrutiny Committee 14 June Air Quality and Car Emissions. Report of the Head of Planning, Transportation and Environment

NOVEL STRATEGIES FOR ASSESSMENT OF AMBIENT AIR QUALITY USING GIS AND ONLINE POLLUTION MONITORING TOOLS I. Jaykumar 2, V. Hima Bindu 2, P.

The testo 340 What makes it The Ultimate Combustion Tuner?

CONFINED SPACE ENTRY WORK STANDARD

The Next Phase in Operational Risk Management: Critical Control Management (CCM) JIM JOY

Element D Services Plumbing

Description of Thermal Oxidizers

How Far is too Far? Statistical Outlier Detection

GUIDELINES ON SAMPLING STRATEGY AND SUBMISSION OF AIR MONITORING / SAMPLE ANALYSIS REPORT

Pulverized Coal Pipe Testing and Balancing

Air Quality: Public Health Impacts and Local Actions

Guide to in situ leak testing of HEPA filter configurations that cannot be conventionally scan tested

Particulate matter sources in Helsinki area and effects on air quality - an overview

Myths and Realities about Wind, Water, and Sun (WWS) Versus Current Fuels Mark Z. Jacobson September 26, 2012

Transcription:

Real-Time DPM Ambient Monitoring in Underground Mines Hsin Wei Wu, A.D.S. Gillies 2, J. D Volkwein 3 and J Noll 4 Director, Gillies Wu Mining Technology, h.wu@minserve.com.au 2 Union Pacific/Rocky Mountain Energy Professor Missouri University of Science and Technology, gilliesst@mst.edu 3 Research Physical Scientist, Pittsburgh Research Laboratories, National Institute of Occupational Health and Safety, jdv@cdc.gov 4 Research Scientist, Pittsburgh Research Laboratories, National Institute of Occupational Health and Safety, jin@cdc.gov ABSTRACT A real-time Diesel Particulate Matter (DPM) monitor has been developed on the basis of the successful National Institute of Occupational Health and Safety (NIOSH) designed Personal Dust Monitor (PDM) unit. The objectives of a recently completed Australian Coal Association Research Program (ACARP) study were to modify the PDM to measure the submicrometre fraction of the aerosol in a real-time monitoring underground instrument. Mine testing focused on use of the monitor in engineering evaluations to determine how conditions can be improved. Studies, including a selection during Longwall (LW) moves as described in this paper, demonstrated how DPM concentrations from vehicles fluctuate under varying ventilation and operational conditions. Correlation between the current SKC DPM measurement system and real-time DPM monitors were conducted and results from six mines show a correlation between elemental carbon (EC) and the new monitor DPM mass ranging from.5 to.8 with R 2 >.90. These differences are suspected to be due to variations from mine to mine in aspects such as mine atmospheric contamination, vehicle fleet variations, fuel type, engine maintenance, engine combustion efficiency, engine behaviour or interference from other submicrometre aerosol..real-time monitoring readily reflects the movement of individual diesel vehicles and allows pin-pointing of high exposure zones such as those encountered where various vehicles work in areas of constrained or difficult ventilation. DPM monitoring approaches that have been available for some time based on shift average monitoring do not readily allow successful engineering evaluation exercises to determine acceptability of pollution levels. Identification of high DPM concentration zones allows efficient modification of mine ventilation, operator positioning and other work practices to reduce miners exposures without waiting for laboratory analysis results.

INTRODUCTION The real-time DPM monitor has been developed on the basis of the successful PDM unit for respirable dust monitoring. The objectives of recently completed ACARP study (Gillies and Wu, 2008) has been to finalise the design of a DPM unit, to undertake comprehensive and internationally recognised laboratory testing, to evaluate the new design, and to undertake an underground series of tests to establish the robustness and reliability of the new approach. The PDM gives real-time readings and is mounted within the miner s cap lamp battery and internally measures the true particle mass of aerosol collected on its filter. Measurements are insensitive to water spray as opposed optically based measurement approaches. It has been recognised that the PDM s unique measurement approach has application to allow real-time atmospheric DPM monitoring. The industry has no real-time direct reading atmospheric DPM monitor at present. Under the project Thermo Fisher Scientific has undertaken structural changes to the PDM to convert it to a DPM real-time monitoring underground instrument, the D-PDM. The Pennsylvania Pittsburgh Research Laboratories of NIOSH (the group that originally contracted for the PDM development) has undertaken laboratory calibration or verification testing. A phase of Australian mine robustness and engineering testing has been undertaken to ensure the instrument can effectively assist mine management to help handle this health issue. Tests have been undertaken at points of expected high atmospheric DPM such as during LW face moves and in Development Headings. The paper discusses how the monitors have performed within the underground mine environment in evaluating DPM during the various phases of LW moves. The project has closely examined the influence of aspects of the mine ventilation system. Results have been compared to alternative industry pollutant measuring approaches. The outcomes of the project demonstrate a new tool for understanding the atmosphere in the presence of DPM. DEVELOPMENT OF REAL-TIME PERSONAL DIESEL PARTICULATE MONITOR Mine atmosphere measurements of DPM in Australian mines have been measured systematically since the early 2000s. Most initial atmospheric readings have been taken on a shift average basis using SKC sampling units. The SKC is derived from a US NIOSH design and gives readings in the surrogate Total Carbon (TC) or Elemental Carbon (EC) units after laboratory analysis procedures have been completed. DPM = TC + inorganics = EC + organic carbon (OC) + inorganics 2

TC in mine testing is generally 80% of DPM (Volkwein 2006). Some DPM regulatory guidelines are starting to emerge in Australia and the individual states are generally moving to acknowledge DPM limits of mg/m 3 submicrometre particulate matter, 0.6 mg/m 3 TC particulate and 0. mg/m 3 EC particulate. A few prescriptive mining regulations are in force internationally such as those applying to the US metalliferous mining industry from May 2008 based on a DPM limit of 0.6 mg/m 3 TC particulate. The real-time DPM monitor is being developed on the basis of the successful PDM unit. Thermo Fisher Scientific has undertaken structural changes to the PDM to convert it to a submicrometre real-time monitoring underground instrument, the D-PDM. The Pittsburgh Research Laboratories of NIOSH (the group that originally contracted for the PDM development) has undertaken laboratory evaluation of the concept. The real time DPM unit continually reports levels of mine atmosphere submicrometre aerosol in mg/m 3 from real-time readings. The submicrometre size-selective inlet selected for this potential field instrument was the BGI -µm sharp-cut cyclone model SCC0.732 followed by a Bureau of Mines (BOM) designed micrometre cut point impactor, at a flow rate of.7 lpm. Figure shows the size selective configuration. BOM, um impactor BGI cyclone DPM and mine dust are pulled into the BGI Cyclone Inlet. Figure Schematic of prototype D-PDM Sampling Inlet. The D-PDM instrument is currently at a prototype stage and as with all new technologies will need industry acceptance and support to reach its full potential. MONITORING OF DIESEL PARTICULATE MATTER The mine tests by their very nature were restricted to equipment available for testing underground. Six of the mines visited (Mines A to F) focused on LW equipment moves from one panel to another and particularly examined the various ventilation arrangements used during shield transport to the installation roadway. The real-time DPM monitors successfully evaluated changes during the different tests and between different steps within the individual tests. 3

Mine A Mine A testing found it was straight forward to analyse results for arrival and departure times of diesel machines at the face and see whether these matched the arrival of the vehicle exhaust plume. Figure 2 examines one three hour period record of real-time DPM readings as compared to heading air velocity and shield carrier speed. Close examination of results from #08 monitoring the DPM downstream of the main gate (MG) and back road showed that when the shield carriers travel in that in three cases they arrived at the tail gate (TG) end of the face in advance of the peak level of the DPM cloud. This indicated that the carriers were generally travelling at higher average speed than the air velocity. However Carrier #2 arrived slightly later indicating slower machine travel speed than air velocity. The time difference and the peak concentration depend on the air velocity and shield carriers travel speeds. Put simply if the shield carrier travels at the same speed as air velocity peak concentration will be extremely high and the carrier will arrive at the same time as the peak. Note that the DPM data has a lag time because it is presented as a rolling average concentration over the previous 0 minutes or 30 minutes. 3 DPM Survey of LW Chock Move Activity Measured Downstream of MG Travel Road #08 0mins #08 30mins 2.5 D-PDM Conc. (mg/m 3 ) 2.5 Chock Carriers Arriving Face #30-23 #2 #3 #30-24 0.5 0 7:20 7:40 8:00 8:20 8:40 9:00 9:20 9:40 0:00 0:20 Time (minutes) Figure 2 Observations on shield carrier DPM over a three hour period at monitor 08 fixed location. Mine B Mine B completed an audit on sources of DPM within a LW installation panel by strategically placing the real-time DPM monitors at points as shown in Table. DPM make values account for DPM monitored value in air mg/m 3 ) and air quantity diluting the exhaust (m 3 /s). These values (mg/s) give a value that can be compared for different equipment under varying ventilation and other mine conditions. 4

Table Sources of DPM identified in the installation LW panel in Mine B. Location Sources (µg/s) % Comments MG C & D Hdgs 3.03 8.6 Mains air at MG entrance Borehole 0.00 0.0 back of LW panel, fresh air LW Face 4.77 29.2 Shunting Mule or LHDs TG D Hdg 6.96 42.6 Shield carriers travel way TG C Hdg 0.00 0.0 No diesel activity Leakages.57 9.6 Mains air; coffin seal & double doors Measured Total 6.32 00.0 Mine C Mine C examined one 2.5 hour period as a 37 tonne Dozer was brought in to pull the first shield on recovery a LW face as shown in Figure 3. About 5 m 3 /s of air was measured on the LW recovery face. Between 4:45 and 5:32, the Dozer attempted to pull out the first shield but was unsuccessful. It worked hard much of the time at maximum revs. Between 5:32 and 6:00, a Shield Carrier Chariot was chained to the Dozer and together they successfully pulled the first Shield while working hard. A general observation on LW moves was that some high submicrometre aerosol readings were recorded due to the large numbers of diesel activities in working sections of the mine. This was contributed to by frequent vehicle movements or traffic jams. Miners should not be placed working inbye heavy vehicles working very hard such as the dozer when pulling shields. For the LW Move routes it is best if vehicle travels against airflow direction. DPM Survey at LW Move Activity Day 2 2007 D-PDM Conc. (mg/m 3 ) 2.8.6.4.2 #06 On Dozer 3504 #08 LW Chock 63 (Outbye) #0 TG B Hdg 8-9ct (Inbye) Dozer pulling Chock 72 #06 D-PDM - 0.050 mg/m 3 #08 D-PDM - 0.072 mg/m 3 #0 D-PDM - 33 mg/m 3 DPM Make = 8.20 mg/s Dozer & Chock Chariot pulling Chock 72 #06 D-PDM - 0.37 mg/m 3 #08 D-PDM - 0.35 mg/m 3 #0 D-PDM - 0.790 mg/m 3 DPM Make = 33.43 mg/s 0 4:40 4:50 5:00 5:0 5:20 5:30 5:40 5:50 6:00 Time (minutes) Figure 3 Submicrometre DPM in LW Recovery Face Pulling Shield. 5

Mine D Mine D monitored a highwall mine with no underground Mains headings. Ventilation quantity was high and air entered the panel in a clean state. It was found over a number of tests that 62% of DPM within the panel was generated by Carriers hauling Shields in the gateroads and 38% generated by vehicle movement along the LW face. DPM Survey at LW Move Activity #0 at LW MG end #08 at LW TG Inbye Installation D-PDM Conc. (mg/m 3 ) Showing when Dozer working inbye of MG monitoring point Time TG MG Difference Dozer DPM Comments mg/m 3 mg/m 3 mg/m 3 mg/s 2:35-3:08 0.79 0.074 0.05 5.24 Full cycle 3:40-4:02 0.32 0.034 0.098 4.89 Full cycle 4:34-5:3 0.8 0.086 0.095 4.78 Full cycle 6:45-7:00 9 0.059 0.60 8.0 Half cycle 0 2:30 3:00 3:30 4:00 4:30 5:00 5:30 6:00 6:30 7:00 Time (minutes) Figure 4 DPM in Mine D LW Installation Face outbye/inbye the face working dozer Air passing down the segregated belt gateroad reached the face clean and could have been used to better effect on the face where operators were installing newly arrived shields. When planning LW moves mines should evaluate and review alternatives for ventilating shield travel roads to the face. The DPM plots in Figure 4 show variability with the Dozer working as four shields were installed. The difference between LW MG and TG plots clearly shows contributions of the face Dozer.. Mine E Mine E tests on the recovery face were in a well ventilated situation with clean gateroad belt heading air significantly diluting any DPM pollution from the gateroad travel heading. An electric tracked mule moved Shields along the face and did not add DPM pollution. Figure 5 shows influence of DPM make at the installation face with outbye monitored levels subtracted. The close match between times chariots face time and DPM pollution levels inbye can clearly be seen. General recommendations were in a planning a LW move it is advantageous to evaluate and 6

review all alternatives for ventilating Shield travel roads to or from the LW recovery and installation faces to reduce peak and average miner exposures. DPM Survey at LW Move Activity Difference in DPM readings between #08 and #0.4 Showing chock chariot arriving, loading chock and departing D-PDM Conc. (mg/m 3 ).2 CC CC 307325 CC 307 CC 307 CC 307 CC 307 CC 307 0 9:30 0:00 0:30 :00 :30 2:00 2:30 3:00 3:30 4:00 4:30 5:00 Time (minutes) Figure 5 Difference in outbye and inbye DPM in Mine E LW Installation Face Mine F Figure 6 shows the influence of DPM make from diesel activities at a LW face with outbye monitored levels subtracted. The close match between time the chariots and Mine F DPM Survey at LW Move Activity 02/09 Difference in DPM readings between LW Chock 75 (#06) and Chock 8 (#0) Chariot Loader into face drop to reposition Chariot Loader into face to 4.0 chock chock drop reposition chock Chariot Loader into face chock drop to reposition 3.5 chock chock ) 3 D -PD M Co nc. (mg /m 3.0 2.5 2.0.5.0 0.5 0.0 0:00 :00 2:00 3:00 4:00 5:00 Time (minutes) Figure 6 DPM and diesel activities in Mine F LW Installation Face 7

loader were operating in the face and monitored pollution levels inbye is clearly seen. An audit was completed on sources of DPM within the LW installation panel by strategic placement of the DPM monitors. It was found that 25% was contributed from outbye diesel activities in Mains, 25% from diesel activities in panel the Travel Road, and 50% from diesel activities within face areas. A good initiative in this mine has been to limit the number of vehicles in the panel by the use of a Tag Board and Traffic controller at the panel travel road entrance. The diesel Tag Board design should consider the diesel loading from outbye Mains diesel activities which account for up to 25% of the total diesel loading for the LW panel. Summary of DPM levels from each shift at points monitored throughout the panel showed increasing levels from influence of additional equipment in series within the ventilation circuit. SKC MINE COMPARISON TESTS It is appropriate to compare field results from the real-time DPM monitor with another available measuring instrument.the NIOSH developed SKC impactor system. The SKC system delivers laboratory analysed shift average results and not real-time results. During investigations parallel underground SKC samples have been taken for comparison with the real-time DPM monitored results. These samples came from the same mine atmosphere through use of a can with outlets for real-time DPM and SKC monitors. Under the SKC system the sample submicrometre fraction is deposited on a filter after first passing through a respirable cyclone sampler and a micrometre impactor that removes most of the mineral fraction of the sample. The sample filter is analysed for EC and (Organic Carbon) OC whose sum is the TC..2 Mine F D-PDM Conc. (mg/m 3 ).0 0.0 Mine C EC = 0.50*Submircron Submicron =.96*EC R 2 = 0.90 Mine A EC = 45*Submicron Submicron =.550*EC R 2 = 0.97 Mine D EC = 50*Submicron Submicron = 2.222*EC R 2 = 0.75 Mine B EC = 6*Submicron Submicron =.226*EC R 2 = 0.98 Mine E EC = 0.788*Submicron Submicron =.269*EC R 2 = 0.97 Mine F EC = 83*Submicron Submicron =.462*EC R 2 = 0.98 0.0.0.2 EC Conc. (mg/m 3 ) Figure 7 Mine individual relationships between EC and Submicrometre DPM 8

D-PDM Conc. (mg/m 3 ).2.0 0.0 Mine C TC = 0.743*Submicron Submicron =.345*TC R 2 = 0.99 Mine A TC = 65*Subm icron Subm icron =.56*TC R 2 = 0.99 Mine D TC = 85*Submicron Submicron =.30*TC R 2 = 0.98 Mine E TC =.082*Submicron Subm icron = 0.924*TC R 2 = 0.98 Mine B TC = 0.968*Submicron Subm icron =.033*TC R 2 = 0.99 Mine F TC = 27*Subm icron Subm icron =.209*TC R 2 = 0.97 0.0.0.2 TC Conc. (mg/m 3 ) Figures 7 and 8 show a related set of results, namely those from Mines A to F LW moves..real-time DPM results (designated as D-PDM measurements) are compared with shift average SKC impactor determinations of EC and TC particulate. Close correlations were found for all cases (R 2 0.97) for TC versus DPM. All EC versus DPM correlations were good (R 2 0.90) except for one set of mine results. The results also demonstrate that relationships (the slopes of the individual mine relationships) vary between mines. This differences in suspected to be due to variations between mines in aspects such as atmospheric contamination, vehicle fleet variations, fuel type, engine maintenance, engine combustion efficiency, engine behaviour, or interference from other submicrometre aerosol. Mine F Figure 8 Mine individual relationships between TC and Submicrometre DPM.4 EC vs DPDM regression DPDM conc (mg/m3).2.0 y =.2x + 0.04 R 2 = 0.97 95% Prediction Intervals 0.0 0.0 0. 0.3 0.5 0.7 0.9 EC conc. (mg/m3) Figure 9 Combined relationships for Six mines between EC and Submicron DPM. 9

Figure 9 shows combined DPM results from the all mine test series compared with SKC impactor collection determinations of EC particulate shift average results taken in the particular mine at the same time. The distribution shows the calculated upper and lower 95% confidence limits about the regression. The combined mines relationships are close with R 2 = 0.97 for EC compared with submicron DPM. There is some international debate on the DPM monitoring issue of whether submicrometre diesel particulate (DP), TC or EC should be evaluated. The real-time DPM monitor is the only one measuring submicrometre DP. Various international studies show that in the normal mine atmosphere (with moderate loadings of respirable dust below statutory limits) the differences and the potential levels of error between the three approaches for monitoring DPM are relatively minor (Birch and Cary, 996, Birch and Noll, 2004 and Dabill, 2005). CONCLUSIONS A project on diesel particulate matter real-time monitoring has been discussed. The outcome is that objective testing over different approaches and comparisons with the SKC monitoring lead to the conclusion that this real-time DPM unit provides reasonable results. The principal industrial application of the unit will be to give a greater understanding through real-time information of DPM levels in mine environments and particularly in engineering evaluation exercises. The paper has discussed how the monitor has performed within the underground mine environment in evaluations of LW moves and has closely examined the influence of aspects of the mine ventilation system on underground DPM pollution. REFERENCES Birch, M.E. and Cary, R.A., 996. Elemental Carbon-based Method for Monitoring Occupational Exposures to Particulate Diesel Exhaust. Aerosol Science and Technology 25: 22-24. Birch, M.E. and Noll, J.D., 2004. Submicrometre Elemental Carbon as a Selective Measure of Diesel Particulate Matter in Coal Mines. J Environ Monit. 2004, 6: 799-806. Dabill, D. W., 2005. Controlling and monitoring exposure to diesel engine exhaust emissions in coal mines, Report HSL/2005/55, Health and Safety Laboratory, Buxton, England Gillies, A.D.S and Wu, H.W. 2008. Evaluation of a first mine real-time diesel particulate matter (DPM) monitor, Australian Coal Association Research Program Grant C5028, Final Report, April. Volkwein, J.C., 2006. Technology Transfer Workshop - Better Use of Diesels Underground, Mackay 22 September and Belmont 26 September 2006. 0