IMMERSION. OEM Installation Guide. GE Lighting. imagination at work. LED Display Lighting. Refrigerated Vertical Cases RV40 Series



Similar documents
IMMERSION TM. GE Lighting. OEM Installation Guide. LED Refrigerated Display Lighting. imagination at work. Center Mullion Lights

IMMERSION TM. GE Lighting. OEM Installation Guide. LED Refrigerated Display Lighting. imagination at work. End Mullion Lights

IMMERSION TM. GE Lighting. Retrofit Installation Guide. LED Refrigerated Display Lighting. imagination at work

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

Albeo TM LED Luminaire Accessory (Emergency Battery Backup Module)

Lumination TM LED Luminaires Light Bar Retrofit Kit Series

LED Security Spotlight User Manual

WIRELESS STATUS MONITOR

Bounce & Spin ZebraTM

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

4.3-inch Back-Up Camera


FortiFone QuickStart Guide for FON-370i

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

Power Supply Guide Version 1.0 for D-Show

LIEBERT VNSA Installation Sheet

MCR1900 Media Converter 19-Slot Chassis

AM/FM ANTENNA KIT (TOUR-PAK MOUNT)

Zebra RW 420 Mobile Battery Eliminator Kits

Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

User s Manual VTECH Printed in China

On/Off Relay Switch and 3-Way Switch Kit

Wireless Optical Mouse

IMPORTANT INFORMATION

FortiFone QuickStart Guide for FON-670i and FON-675i

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

INSTALLATION MANUAL ELECTRIC RANGE. Please read these instructions thoroughly before installing and operating the range.

HMI display Installation Guide

AMERBRITE UNDERWATER WHITE LED POOL LAMP

Installation Guide. Wyse VX0L and VX0LE Thin Clients 1-GB RAM Upgrade Option Kit. Issue: PN: L Rev. A

Manual. Simrad StructureScan LSS-1 Sonar Module. English

Model 201 Wiegand Touchpad Reader Installation Guide

GSM-EXT Cable Assembly Installation Guide

SmartCard On-Board Reader (# 8105) SmartCard Desktop Reader (# 8108) SmartCards, Pack of 10 (# 8112) Starter Interrupter Kit (# 8116)

User Guide. LXX35-LED Light Source. Luxxor LXX35-LED User Guide. Contents

aseries A13B Mini Bullet Camera User Manual

Beautifully Traditional

LED MOTION ACTIVATED FLOOD LIGHT

GENUINE PARTS INSTALLATION INSTRUCTIONS

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

WARNING CANADIAN D.O.C. WARNING

Important Information

SNQ-60x0-320 Series Data Center Switch. Quick Installation Guide

InnoMedia ESBC B. Quick Install Guide. 1

Super Sounds Soccer. Model B8507

767 Diagnostic System

5800 Temperature Sensor Cable Assembly

BBWX1 Satellite Weather Receiver. Installation and Maintenance Guide

Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

INSTALLATION INSTRUCTIONS

alkaline fisher-price.com

Aura SSD. for the 2013 Apple Mac Pro INSTALLATION GUIDE

StructureScan HD Module. Installation Guide ENGLISH

Backup Scanner Module

INSTALLATION INSTRUCTIONS

Nevco, Inc. Installation Manual

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

CortezTM A Kichler Décor Ceiling Fan

User s Manual VTech Printed in China US

INSTRUCTIONS FOR THE INSTALLATION AND OPERATION OF ACTIVATOR II

TOYOTA Tundra BACK-UP CAMERA SYSTEM Preparation

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Wetroom Panel (Concealed Fix)

Vehicle Power Install Kit

Fire Fighter Phone System Installation Instructions

ADSL Modem Installation Guide. Model # 36R515 Part # Rev. D Revision Date 12/2000. ADSL Modem Installation Guide

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

GreenWay Solar LED Path and Trail Lighting System. Installation and Owner s Manual

Direct AC Wiring Option Installation Guide

AD511 Active Iridium Antenna User Manual Mar 12 V4.0

Wireless Alarm System. Panic Button. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location

ColdGuard Bi-PARTING DOOR INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTION Touch Panel Switch with Occupancy Sensor

Toroidal Conductivity Sensor

EVOLUTION Thermal Imaging Camera Remote Wireless Video Receiver System

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

PEARL Portable Reading Camera

SECTION 7 - REPAIR/REPLACEMENT PROCEDURES

FCC COMPLIANCE STATEMENT FOR AMERICAN USERS

INTRODUCTION INTERLOCK KIT K-8110

GENUINE PARTS INSTALLATION INSTRUCTIONS

by Myles H. Kitchen M.H. KITCHEN & ASSOCIATES (2002 X5 4.4 owner) March 2, 2004

InnoMedia ESBC B. Quick Install Guide. 1

2013 VTech Printed in China US

Installation Instructions

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

DVI DA2 and DVI DA 4 User Guide

12VDC MAGNETIC LED DIMMABLE POWER SUPPLIES SPEC SHEET DIGEST

About the HotWire Slot Standalone Shelf

Owner s Guide and Installation Manual. Vancouver Model Name , Model No. English Español

FRONT BUMPER INSTALLATION INSTRUCTIONS DODGE / MERCEDES SPRINTER

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

AM/FM ANTENNA RELOCATION KIT

Malibu Monte Carlo El Camino

Advantium 2 Plus Alarm

LT Charging Cart for Laptops

AI120 AIswitch Series 120 Chassis

Transcription:

GE Lighting OEM Installation Guide IMMESION isplay Lighting efrigerated Vertical Cases V0 Series End Mullion Lights 8-inch: GELT0850E-SY/-S (6560/65606), GELT0850EL-SY/-S (6560/65607), GELT080E-SY/-S (65609/6561), GELT080EL-SY/-S (65610/6561), GELT085E-SY/-S (65615/65618), GELT085EL-SY/-S (65616/65619) 60-inch: GELT0605EL-SY/-S (79755/79758), GELT0605E-SY/-S (7975/79757), GELT0600EL-SY/-S (7979/7975), GELT0600E-SY/-S (7978/79751), GELT06050EL-SY/-S (797/7976) & GELT06050E-SY/-S (797/7975) 70-inch: GELT0705EL-SY/-S (7977/79776), GELT0700EL-SY/-S (79767/79770), GELT07050EL-SY/-S (79761/7976), GELT0705E-SY/-S (7977/79775), GELT0700E-SY/-S (79766/79769), GELT07050E-SY/-S (79760/7976) escription Code (Single Unit Product Number / 10-Pack Product Number) EFOE YOU EGIN ead these instructions completely and carefully. FO YOU SFETY ead and observe all CUTIONS and NINGS shown throughout these instructions. Installation to be performed by factory trained service personnel only. For use inside a commercial refrigeration case with packaged foods only. This device complies with part 15 of the FCC ules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and () this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class digital device, pursuant to part 15 of the FCC ules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This Class [] FL complies with the Canadian standard ICES-00. Ce EF de la classe [] est conforme à la NM-00 du Canada. NING / VETISSMENT isk of electrical shock. isconnect power before servicing or installing product. / isque de choc électrique. Couper le courant avant de réparer ou installer le produit. COMPTIILITY This system is compatible with the GEPS000NCMUL-SY river. Please refer to the separate driver installation guide for appropriate wiring connections. CUTION / TTENTION isk of injury. hile performing installations described, gloves, safety glasses or goggles should be worn. / isque de blessure. Lors de l'exécution des installations décrites, des gants, des lunettes de sécurité ou des lunettes de protection doivent être portées.. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.. efore servicing or cleaning unit, switch power off at the service panel and follow appropriate lock out /tag out safety procedures. PEPE ELECTICL IING Electrical equirements The power supply must be supplied with 100-0 VC, 50/60 Hz., and connected to an individual properly grounded branch circuit, protected by a 15 or 0 ampere circuit breaker or time delay fuse. iring must be wire with ground and rated for 75 C (167 F). o not overload driver, follow installation instructions for the GEPS000NCMUL-SY. Ensure that all connection points are sealed for damp location using the appropriate method per the NEC or local electrical code. imagination at work

Tools equired Components equired 1 5 6 7 1 5 6 7 ire stripper/cutter Tape measure Screwdriver Cordless drill Hammer 7/6-inch (.8mm) drill bit Center punch 1 light driver ire cover 6- x 1/" screws NING/VETISSEMENT Les pièces et câbles électriques risquent d être endommagés lors du perçage 1 Prepare for Installation of End Lights Measure 1 /-inches (8 mm) from the edge of the mullion nearest the door, and mark a vertical line near the top and bottom of the frame mullion. Prepare for the upper end of the End Light. Mark a horizontal line a minimum 1/8-inches (5 mm) from the top of the door opening, and another horizontal line /8-inches (10 mm) below this line. Prepare for the lower end of the End Light. For 8-inch Lights mark a horizontal line 6 1/" (1175mm) beneath the first line drawn for the top Mounting. For 60-inch Lights, mark a horizontal line 58 /-inches (176 mm) beneath the first line drawn for the top Mounting Tab. For 70-inch Lights, mark a horizontal line 68 15/" (179 mm) beneath the first line drawn for the top Mounting Tab. Then mark another line /8-inches (10 mm) below this line. Center the center punch directly at the intersection of the horizontal lines and the vertical line (top and bottom) and establish a dimple. Left End Shield river Leads Center Punch at Intersection and drill a 7/6-inch (.8 mm) hole 1-/" (8 mm) 1-/" (8 mm) ight End Shield 1/8" (5 mm) /8" (10 mm) For 8-inch Lights: 6 1/" (1175mm) For 60-inch Lights: 58 /" (176 mm) For 70-inch Lights: 68 15/" (179 mm) /8" (10 mm) Use power drill and 7/6-inch (.8 mm) drill bit to drill holes at the intersection of the vertical center line and the horizontal lines. epeat these steps for the mullion on the other end of the case. End Mullion - Left End Mullion - ight View from inside the case looking out

ire ire 1 Identify End Light - ight from Left EL E Verify s are directed towards the center of the case before installing. NOTE: Installing the Light on the wrong side will result in very low light level inside the refrigerated case. View from inside the case looking out NING / VETISSMENT isk of electrical shock. Only those open holes indicated in the photographs and/or drawings may be made or altered as a result of kit installation. o not leave any other open holes in an enclosure of wiring or electric components / isque de choc électrique. Seuls les trous ouverts indiqués dans les photos et / ou les dessins peuvent être faites ou modifiés à la suite du montage du kit. Ne pas laisser autres trous ouverts dans l'enceinte du câblage électrique ou composants. Install End Lights Place proper End Light against the face of the mullion near the two holes drilled at the top. NOTE: efer to proper End Light orientation depicted in Step 1. End Light Power Leads river Output Leads Insert a #6- x 1/-inch sheet metal screw into the slot of the Mounting Tab on the End Light, and into the first hole that was drilled in the end mullion. Use a screwdriver to start threading the screw into the drilled hole. epeat for the second screw, and for the bottom of the End Light. Mounting Tab epeat these steps for the mullion on the other end of the case. Make sure the orientation is correct and proper Light is used. efer to the manufacturing manual for door frame to ensure there are no components contained inside the mullion that could be drilled through. Use a #6 - /-inch self-drilling screw to attach the End Light into one or two of the additional mounting holes located near the center of the Light. efer to wiring diagram on page 5. Connect the red and black output wires from the Light to the red and black wires on the river using the twist lock splice wire connectors provided.

CUTION / TTENTION isk of injury. o not overload river, 60-watts maximum per driver. For 8-inch Lights, do not exceed Center Lights per driver loading limit. ( End Lights is equivalent to 1 Center Light). For 60-inch Lights, do not exceed Center Lights per driver. ( End Lights is equivalent to 1 Center light). For 70-inch Lights, do not exceed Center Lights plus 1 End Light per driver loading limit. isque de blessure. Ne pas surcharger le driver, 60-watts maximum par driver. ans le cas des lampes de 8"-1 cm, ne pas dépasser lampes centrales par limite de charge du driver. ( lampes latérales équivalent à 1 lampe centrale). ans le cas des lampes de 60"- 1 cm, ne pas dépasser lampes centrales par limite de charge du driver. ( lampes latérales équivalent à 1 lampe centrale). ans le cas des lampes de 70"-175 cm, ne pas dépasser lampes centrales et 1 lampe latérale par limite de charge de driver. river Configuration Options The diagrams below represent wiring configurations for each river. 6-oor Case For 8" Lights For 60" Lights For 70" Lights 5-oor Case -oor Case For 8", 60" & 70" Lights For 8" Lights For 60" & 70" Lights -oor Case -oor Case For 8" & 60" Lights For 70" Lights For 8", 60" & 70" Lights Parts Needed Per Case 6-oor 5-oor -oor -oor -oor Center Lights 5 1 End Light Sets 1 1 1 1 1 rivers (60-inch Lights) 1 1 rivers (70-inch Lights) 1 rivers (8-inch Lights 1 1 1 ire Covers 7 6 5

NING / VETISSMENT isk of electrical shock. Ensure that all connection points are sealed for damp location using the appropriate method per the NEC or local electrical code. isque de choc électrique. S assurer que les points de raccordements sont scellés pour emplacement humide en employant une méthode permise par le NEC ou par le code électrique local. Connection Configurations For information on,, C,, see Steps, 5 and 6. One End Set ( & L) Lights Note: Lights are polarity insensitive Two Center Lights Note: Lights are polarity insensitive One Center Light Note: Lights are polarity insensitive IGHT EN LIGHT LEFT EN LIGHT CENTE LIGHT CENTE LIGHT CENTE LIGHT C C C C LCK (LINE) HITE (NEUTL) TEMINL LOCK TEMINL LOCK HITE (NEUTL) C LCK (LINE) TEMINL LOCK TEMINL LOCK C HITE (NEUTL) LCK (LINE) TEMINL LOCK TEMINL LOCK One End Set (ight and Left) & One Center Light One End Light (ight or Left) & One Center Light Note: Lights are polarity insensitive Note: Lights are polarity insensitive C IGHT EN LIGHT LEFT EN LIGHT CENTE LIGHT C EN ( or L) LIGHT CENTE LIGHT ire Cavities 9-01-00 (C) Cavity 1 - Line 1 (lack) Cavity - Earth Ground (Green) Cavity - Neutral or Line (hite) 9-01-06 (C) Cavity 1 - Output C (+) (red) Cavity - Output C (-) (black) Cavity - imming (Purple) Cavity - imming (Gray) C HITE (NEUTL) LCK (LINE) TEMINL LOCK TEMINL LOCK C HITE (NEUTL) LCK (LINE) TEMINL LOCK TEMINL LOCK 5

Connect river - Output Make output (C) connections using one of the two options below: OPTION 1 USING -Y CONNECTO Connect the river output leads to the Light leads using the appropriate mating connector (Molex P/N 9-01- 06). Terminals installed should be crimped using approved tooling and process per Molex specifications. Ensure that the connector cavities are correctly populated per the wire cavity table on page 5. OPTION USING TIST-ON IE CONNECTOS emove the -way connector from the river by cutting the wires near the connector and strip the output leads. Using the appropriate wiring diagram on page 5, connect the river output leads to the Light leads using wire connectors or other connection method approved for low temperature usage and stranded cable. () 5 6 Connect river - Input Make input (C) connections using one of the two options below: The river is required to be reliably bonded to the protective ground conductor. OPTION 1 USING -Y CONNECTO ttach the supplied green/yellow ground wire from the river to a grounded metal portion of the door frame. Connect the original Line and neutral wires (or Line 1 and Line wires for 0 nominal VC) to the -way connector for the river input wires using the appropriate matingconnector (Molex P/N 9-01-00). Ensure that the connector cavities are correctly populated per the wire cavity table on page 5. C Connect imming Contacts Output (Optional) For non-dimming applications, cap the unused wires with 5/" (mm) twist on wire connectors. OPTION USING TIST-ON IE CONNECTO ttach the supplied green/yellow ground wire from the river to a grounded metal portion of the door frame. emove the -way connector from the river by cutting the wires near the connector and strip the input wires. Using the appropriate wiring diagram on page 5, connect the original Line and neutral wires (or Line 1 and Line wires for 0 nominal VC) to the river leads using twist lock wire connectors or other connection method approved for low temperature usage and stranded cable. Ensure that the connector cavities are correctly populated per wire cavity table on page 5. C To enable dimming operation, connect leads from occupancy sensor or control system (normally open contact) to the purple and gray leads of the power supply. Make output (contact closure) connections using one of the two options below: OPTION 1 USING -Y CONNECTO Connect the river dimming output leads to the occupancy sensor or control system using the appropriate mating connector (Molex P/N 9-01-06). Terminals installed should be crimped using approved tooling and process per Molex specifications. Ensure that the connector cavities are correctly populated per the wire cavity table on page 5. () OPTION USING TIST-ON IE CONNECTOS emove the -way connector from the river by cutting the wires near the connector and strip the output leads. Using the appropriate wiring diagram on page 5, connect the river dimming output leads to the occupancy sensor or control system using wire connectors or other connection method approved for low temperature usage and stranded cable. () The river is capable of step dimming from 100% power to 0% power when used with a normally open contact closure occupancy sensor system. hen using the drivers for non-dimming applications, the dip switch setting must be set to #1 ON to disable the dimming feature and achieve 100% illumination. 6

CUTION / TTENTION isk of electrical shock. Plastic cover is needed to protect electrical wires from tampering and accidental contact. / isque de choc électrique. Le couvercle en plastique est requis pour assurer une protection adéquate contre l'accès aux fils et les contacts accidentels. 7 ttach Covers to End Cap Tuck wires underneath ire Cover before placing it over the End Cap and Mounting Tab. ire Cover ttach ire Cover to Light End Cap by installing a M.9x10 pan head tapping screw (provided) through the hole in the End Cap and Mounting Tab using an installation torque of lbf-in. NOTE: Tighten slowly until fully seated, do not over tighten or strip the threads. epeat these steps for the mullion on the other end of the case. End Cap M.9x10 pan head tapping screw CUTION / TTENTION isk of electrical shock. Plastic cover is needed to protect electrical wires from tampering and accidental contact. / isque de choc électrique. Le couvercle en plastique est requis pour assurer une protection adéquate contre l'accès aux fils et les contacts accidentels. 8 emoval Instructions Using a phillips screwdriver, remove screw and cover from wire end of Light and screw from opposite end of Light. Electrical connections can be removed to facilitate the removal of the Light. emove the #6- x 1/ inch sheet metal screws that hold the Light to the mullion. Make sure you support the End Light with your free hand. epeat these steps for the mullion on the other end of the case. ire Cap 7

NING / VETISSMENT isk of electrical shock. isconnect power to Lights before any cleaning operation. isque de choc électrique. ébranchez l'alimentation des éclairages à avant toute opération de nettoyage. 9 efigerated isplay Lights Cleaning Instructions The outer lens and the plastic housing should be cleaned periodically with a mild liquid dish detergent. o not wipe the lens with a soiled dish cloth or wet towel. These may leave a residue that can damage the finish. o not use chemical cleaners to clean the lens. Keep the outside clean. ipe with a clean cloth lightly dampened with mild liquid dish detergent. ry with a clean, soft cloth. o not use scouring pads, powdered cleaners, bleach or cleaners containing bleach because these products can scratch and damage the finish. This product is intended solely for the use of commercial refrigerated, display or case lighting and is not intended for use in any other application. GE Lighting Solutions 1-888-MY-GE- www.gelighting.com 1-8 8 8-6 9--5 GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. Immersion is a trademark of GE Lighting Solutions, LLC. The GE brand and logo are trademarks of the General Electric Company. 01 GE Lighting Solutions, LLC. Information provided is subject to change without notice. ll values are design or typical values when measured under laboratory conditions. 8 1515-11081