EDXRF of Used Automotive Catalytic Converters



Similar documents
Amptek Application Note XRF-1: XRF Spectra and Spectra Analysis Software By R.Redus, Chief Scientist, Amptek Inc, 2008.

Quantitative Analysis Software for X-Ray Fluorescence. XRF-FP is a full-featured quantitative analysis package for XRF

Portable X-ray fluorescence Spectroscopy. Michael A. Wilson Research Soil Scientist USDA-NRCS National Soil Survey Center Lincoln, NE

Coating Thickness and Composition Analysis by Micro-EDXRF

Instrumentation. (Figure 2)

X-RAY FLUORESCENCE SPECTROSCOPY IN PLASTICS RECYCLING

Using the Bruker Tracer III-SD Handheld X-Ray Fluorescence Spectrometer using PC Software for Data Collection

X Ray Flourescence (XRF)

Advanced Physics Laboratory. XRF X-Ray Fluorescence: Energy-Dispersive analysis (EDXRF)

ON-STREAM XRF ANALYSIS OF HEAVY METALS AT PPM CONCENTRATIONS

The Limitations of Hand-held XRF Analyzers as a Quantitative Tool for Measuring Heavy Metal Pesticides on Art Objects. By Özge Gençay Üstün

h e l p s y o u C O N T R O L

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

Introduction to Elemental Analysis by ED-XRF Justin Masone Product Specialist 3 June 2015

Chem 115 POGIL Worksheet - Week 4 Moles & Stoichiometry

EDS system. CRF Oxford Instruments INCA CRF EDAX Genesis EVEX- NanoAnalysis Table top system

Quality Control on Aerospace Components Using Handheld X-ray Fluorescence (XRF)

Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry

Application Note # EDS-10 Advanced light element and low energy X-ray analysis of a TiB 2 TiC SiC ceramic material using EDS spectrum imaging

OLIVÉR BÁNHIDI 1. Introduction

Lectures about XRF (X-Ray Fluorescence)

Atomic and Nuclear Physics Laboratory (Physics 4780)

Field portable XRF analysis of environmental samples

Metals in Soil Analysis Using Field Portable X-ray Fluorescence

ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS

Activitity (of a radioisotope): The number of nuclei in a sample undergoing radioactive decay in each second. It is commonly expressed in curies

Sample Analysis Design Isotope Dilution

Chem 115 POGIL Worksheet - Week 4 Moles & Stoichiometry Answers

Multi-elemental determination of gasoline using Agilent 5100 ICP-OES with oxygen injection and a temperature controlled spray chamber

Introduction to Geiger Counters

GAMMA-RAY SPECTRA REFERENCES

Reflectance Measurements of Materials Used in the Solar Industry. Selecting the Appropriate Accessories for UV/Vis/NIR Measurements.

Tutorial 4.6 Gamma Spectrum Analysis

An Innovative Method for Dead Time Correction in Nuclear Spectroscopy

Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9

The NEW X-MET7000 Faster, lighter,

X-Ray Fluorescence - Data Collection and Analysis

UV/VIS/IR SPECTROSCOPY ANALYSIS OF NANOPARTICLES

Austin Peay State University Department of Chemistry Chem The Use of the Spectrophotometer and Beer's Law

THERMO NORAN SYSTEM SIX ENERGY DISPERSIVE X- RAY SPECTROMETER. Insert Nickname Here. Operating Instructions

Pesticide Analysis by Mass Spectrometry

RoHS Test Methods. Presented by: Bruce Peterson

Graphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY (VERSION 1.

EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions.

Spectral distribution from end window X-ray tubes

Introduction to Fourier Transform Infrared Spectrometry

Gamma Rays OBJECT: READINGS: APPARATUS: BACKGROUND:

Signal to Noise Instrumental Excel Assignment

SUS. Company Profile. Ulrich Nell, Feldstr.23, D Oberhausen, Tel. 0049(0)208/ Fax 0049(0)208/658536

The photoionization detector (PID) utilizes ultraviolet

Infrared Spectroscopy: Theory

Improved predictive modeling of white LEDs with accurate luminescence simulation and practical inputs

GRID AND PRISM SPECTROMETERS

CHEM 101/105 Numbers and mass / Counting and weighing Lect-03

Lab #11: Determination of a Chemical Equilibrium Constant

Universal Data Acquisition (UDA)

CH3 Stoichiometry. The violent chemical reaction of bromine and phosphorus. P.76

Energy Dispersive Spectroscopy on the SEM: A Primer

Problem Set 6 UV-Vis Absorption Spectroscopy Express the following absorbances in terms of percent transmittance:

Gold Refining and Coin Manufacturing at the Royal Canadian Mint

Trace Gas Exchange Measurements with Standard Infrared Analyzers

UNITED STATES CONSUMER PRODUCT SAFETY COMMISSION DIRECTORATE FOR LABORATORY SCIENCES DIVISION OF CHEMISTRY 5 RESEARCH PLACE ROCKVILLE, MD 20850

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

Radiation Strip Thickness Measurement Systems

ENERGY PER PHOTOELECTRON IN A COINCIDENCE LIQUID SCINTILLATION COUNTER AS A FUNCTION OF ELECTRON ENERGY. Donald L. Horrocks

FTIR Instrumentation

QUANTITATIVE INFRARED SPECTROSCOPY. Willard et. al. Instrumental Methods of Analysis, 7th edition, Wadsworth Publishing Co., Belmont, CA 1988, Ch 11.

Nuclear Physics Lab I: Geiger-Müller Counter and Nuclear Counting Statistics

A Beer s Law Experiment

Building Electrochemical Cells

Electron Microscopy 3. SEM. Image formation, detection, resolution, signal to noise ratio, interaction volume, contrasts

Radiation Detection and Measurement

CALCULATION METHODS OF X-RAY SPECTRA: A COMPARATIVE STUDY

Chemistry 122 Mines, Spring 2014

Basic Concepts of X-ray X Fluorescence by Miguel Santiago, Scientific Instrumentation Specialist

3 - Atomic Absorption Spectroscopy

KINETIC DETERMINATION OF SELENIUM BY VISIBLE SPECTROSCOPY (VERSION 1.8)

EXPERIMENT 4 The Periodic Table - Atoms and Elements

Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13

IDENTIFICATION OF PAINTING MATERIALS USED FOR MURAL PAINTINGS BY IMAGE ANALYSIS AND XRF

Upon completion of this lab, the student will be able to:

Solutions and Dilutions

Introduction to Energy Dispersive X-ray Spectrometry (EDS)

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

USE OF REFERENCE MATERIALS IN THE LABORATORY

Introduction to X-Ray Powder Diffraction Data Analysis

Chem 131A: Absorbance of Riboflavin

Radioactivity III: Measurement of Half Life.

The Fundamentals of Infrared Spectroscopy. Joe Van Gompel, PhD

International Year of Light 2015 Tech-Talks BREGENZ: Mehmet Arik Well-Being in Office Applications Light Measurement & Quality Parameters

Introduktion til røntgenfluorescens (XRF) og skanning elektron mikroskopi (SEM) Michelle Taube Nationalmuseet Bevaringsafdelingen

NET IONIC EQUATIONS. A balanced chemical equation can describe all chemical reactions, an example of such an equation is:

Unit 2: Quantities in Chemistry

13C NMR Spectroscopy

Elemental Analyses by ICP-AES

Determination of Metals in a 3% Sodium Chloride (NaCl) Matrix by Axially-Viewed ICP-OES

Appendix 5 Overview of requirements in English

PUMPED Nd:YAG LASER. Last Revision: August 21, 2007

Transcription:

EDXRF of Used Automotive Catalytic Converters Energy Dispersive X-Ray Fluorescence (EDXRF) is a very powerful technique for measuring the concentration of elements in a sample. It is fast, nondestructive, requires no sample preparation, and can be carried out in the field or on a factory floor by operators with minimal training. It is a very important complement to other methods in analytical chemistry. Amptek, Inc. provides components used in many EDXRF systems. Amptek is an OEM provider of X-ray detectors, preamplifiers, signal processing electronics, X- ray tubes, and analysis software to many of the companies providing turnkey EDXRF analyzers. These components are also used in custom systems, when the requirements not met by turnkey analyzers. This note illustrates an application of Amptek s products: measuring the composition of used automotive catalytic converters. This is a challenging measurement but important measurement for XRF. Used catalytic converters have a low concentration (hundreds of ppm) of valuable elements, generally Rh, Pd, and Pt. Accurate measurements of their concentrations are important for determining the value of a used converter. The challenge for XRF is that used catalytic converters also contain many other elements (Pb, Os, Ce, La, Ba, Zn, Zr, Fe) at much higher concentrations. Further complicating the measurement, these materials are in a low Z matrix (aluminum and silicon oxides). This application is shown here because it illustrates some of the important challenges one faces in measuring complex materials. 1 INTRODUCTION Catalytic converters contain valuable materials. A typical automotive catalytic converter contains 2 to 7 grams of Pt and smaller quantities of Rh and Pd. With spot prices of $50, $60, and $25 per gram, respectively, both buyers and sellers of used catalytic converters need to know the concentration. A used catalytic converter typically sells for $20 to $30 with most of the value associated with these precious metals. These precious metals are mounted on a ceramic substrate (silicon and aluminum oxides) at a concentration of tens to hundreds of ppm. Other metals may also be present: Ce, La, Fe, Ni, and Cu are also catalysts. Pb, Mn, and Zn are contaminants which may be found in gasoline additives, which poison the catalysts. These materials are often present at much higher levels than the precious metals one must measure. There are many different methods in analytical chemistry which can be used to measure the concentration of precious metals in the catalytic converter. Many of the methods involve wet chemistry, so are destructive, must be carried out in a lab, require considerable time and labor, and produce a hazardous waste stream. EDXRF has some key advantages over other methods. First, it is non-destructive. Second, it requires no sample preparation. Third, it takes only tens of seconds per item. Fourth, it can be carried out in the field by operators with minimal training. EDXRF provides quick and non-destructive screening, with other methods available to validate the EDXRF results. PROTOTYPE ANALYZER DESCRIPTION The laboratory prototype used here is shown in Figure 1. It is not packaged for commercial use but contains all of the components necessary to carry out EDXRF analysis and is fully functional. Everything except the mechanical fixture and radiation shielding are standard products from Amptek, Inc. It includes 1) An Amptek 25 mm 2 SDD X-ray detector, with a resolution of 128 ev at the Mn K line. 2) An Amptek X-123-SDD incorporating a DP5 digital pulse processor and PC5 power supplies, operated here at a peaking time of 9.6 s (shaping time of 4 s), output count rate of 8 kcps, dead time of 15%. 3) An Amptek Mini-X X-ray tube at 40 kvp and 50 A. Both Ag and W anodes were used, with different filters, discussed in the text. 4) A mechanical fixture to hold the detector, tube, and sample, along with radiation shielding. 5) Amptek's ADMCA software for data acquisition and control of the signal processor and software to control the X-ray tube. Both use a USB interface. 6) Amptek's XRS-FP software for spectrum processing and quantitative analysis. The system was not fully optimized for this application but demonstrates key considerations. The samples were in powder form. They were Standard Reference Materials, 2556 and 2557 from NIST. Figure 1. Photograph of the prototype analyzer. Amptek Inc. 1

Figure 2. Spectrum measured from one SRM 2556 plotted on a linear scale (black) and on a log scale (blue). SPECTRA Figure 2 shows a raw spectrum taken on SRM 2556. The same data are plotted on both linear and log vertical scales, in black and blue respectively. Figure 3 shows the same raw spectrum in black, along with the processed spectrum. The blue trace is the background continuum, while the gray trace is the result of correcting for escape peaks, pile-up, and background removal. The red filled trace shows the fit of the Pt L peaks to the (gray) corrected spectrum. The green lines mark the numerous Pb L lines. Lead has a concentration of 0.6%, so the Pb L lines clearly dominate the spectrum. Spectral lines from the precious metals are easily seen but accurately quantifying their concentration presents some challenges. The first measurement challenge is to properly process the spectrum to accurately determine photopeak areas. The Pt peaks exhibit overlap, e.g. Pt L overlaps the Zn K and Pb L peaks on either side. The Rh K line is superimposed on a large background continuum. La and Ce are not the most valuable components but are important, and only weak L lines are visible, superimposed on escape peaks and background. The second challenge is addressing the matrix effects. One must account for both the low Z portion of the matrix, which attenuates the X-rays of interest, and the higher Z portion which exhibits both absorption and enhancement. The light elements, aluminum and silicon oxides, are not directly seen in the spectrum while the high Z elements overlap. Figure 3. Detail of spectrum shown in Figure 2, showing both processed and raw spectra. Amptek Inc. 2

Counts AN-XRF-005 Rev B0 SRM 2556 SRM 2557 NIST Values Measured NIST Values Measured Fe 8,000 7,658 + 94 15,000 12,776 + 788 Ni 360 + 17 5,000 5,311 + 710 Zn 600 594 + 7 1,000 652 + 14 Zr 300 310 + 3 300 291 + 6 Rh 51 + 1 47 + 4 135 + 2 132 + 14 Pd 326 + 2 341 + 5 233 + 2 230 + 18 Cd 3 + 8 44 0 + 1 Ba 100 177 + 89 2,900 1,267 + 232 La 7,000 3,385 + 746 700 289 + 715 Ce 10,000 10,426 + 337 13,000 12,344 + 489 Pt 697 + 2 695 + 12 1,131 + 11 1,011 + 53 Pb 6,228 + 49 6,288 + 64 13.931 + 97 12,003 + 827 Table 1. Summary of measurement results, in ppm. Note that the NIST SRM only specified the measurement uncertainty for Pb, Pt, Rh, and Pd. The other concentrations of the other elements were "for reference only" and had no specified uncertainty, in part because of disagreements between the results of different chemical analyses. RESULTS Table 1 shows the results of the analysis. These results were obtained using a Mini-X with a W anode, using nonlinear deconvolution to fit the spectra and using a fundamental parameters (FP) analysis method, calibrated using these standards. A long duration (1 hour) reference spectrum was obtained with each sample and used to calibrate the FP parameters. A set of 50 spectra, of five minute durations, were then taken on each sample and analyzed using these parameters. The "measured" column shows the mean of the 50 measurements. NIST reported certified values and a measurement uncertaintly only for the Pt, Pb, Rh, and Pd. The other elements are non-certified because there was not agreement between different analytical methods. The uncertainty listed in the "measured" columns is the one sigma standard deviation of the 50 results. 2 DISCUSSION CONFIGURING THE SYSTEM Detector and signal processing It is important to choose the best detector and to select the best signal processing parameters. For this particular application, high energy resolution is very important to separate the many closely spaced spectral lines. This is why the 25 mm 2 SDD was chosen, with a peaking time of 9.6 s, giving an energy resolution of 128 ev FWHM at 5.89 kev. In many EDXRF applications, in fact most applications, energy resolution is not the most critical parameters. The quality of the analytical results always depends on the number of counts in the spectrum, and for most cases, the optimum configuration is at a relatively short peaking time (with degraded energy resolution) but high count rates (assuming the X-ray tube can provide enough flux). For this application, however, energy resolution is vital. Excitation Source The choice and configuration of the excitation source can have a major effect on the precision and accuracy of the measurement. Figure 4 shows four different spectra from the same sample, SRM 2556, with different configurations for the excitation source. These illustrate some of the major issues. The green trace shows the same configuration as Figure 2, yielding the data shown in Table 1. This was a W anode tube, operated at 40 kvp, using a filter consisting of 25 m W covered by 1000 m Al. This is yields a low background continuum below 20 kev. Amptek Inc. 3 2.0E+04 1.6E+04 1.2E+04 8.0E+03 4.0E+03 0.0E+00 0 5 10 15 20 25 30 35 40 Energy (kev) La & Ce K lines 50 kvp Filter A 50 kvp Filter B 40 kvp Filter A 40 vkp Ag Figure 4. Spectra taken using different configurations for the X-ray tube, the excitation source. The blue trace shows the spectrum with a prototype 50 kvp Au anode X-ray tube with the same filter, at

the same current. The most visible change is that the La and Ce K lines are excited. These K lines are strong and well separated from the background, unlike the L lines around 5 kev. This uncertainty of the La and Ce measurement with this configuration will be 25x better (everything else kept equal). The photopeak intensities and net count rate are about twice those of the green trace, simply because more X-rays exit the filter. There is more background continuum at low energy, below 5 kev. This continuum is due to incident X-rays which Compton scatter out of the detector. The red trace shows the same 50 kvp Au anode tube but with more filtering (50 m W behind 1000 m Al) and twice the beam current. The heavier filtering reduces the background from 20 to 30 kev, thus improving the detection of Rh and Pd. The photopeak count rates and low energy background are comparable to the blue trace. The heavy filter improves the background, but for the same current reduces the photopeak intensities. The optimum will depend on the application. The black trace was obtained with an Ag anode tube operated under the same conditions as the W anode tube yielding the green trace (40 kvp, same filter, same current). The major different is that scatter peaks from the Ag K lines at 22 and 25 kev are visible. This includes Rayleigh peaks at 22 and 25 kev and broader Compton peaks are lower energy. As will be discussed below, the relative intensity of the Rayleigh and Compton peaks indicates the mean Z of the matrix. This can be used in matrix correction to account for the low Z portion of the matrix. With this particular measurement, the Ag scattered lines overlap with the Rh and Pd K lines. The advantage of doing a scatter correction must be weighed against the need to separate these peaks. The point of this discussion is that the choice of the X-ray tube, the kvp setting, and the tube filter are very important. Many instrument include multiple filters or a filter wheel. A single sample might be analyzed with two filters (and different kvp settings) which are optimized for different elements. MATRIX EFFECTS Quantitative analysis in EDXRF is based on the relationship Ci Ki Ii Mi [1] where C i is the measured concentration of element i, K i is its calibration factor, I i is the photopeak intensity for that element, and M i represents a correction for matrix effects. In chemical analysis, "matrix" refers to the components of a sample other than the analyte. In the used automotive catalyst, when measuring the concentration of Pt, the matrix is everything but Pt. Both absorption and enhancement effects are important. The Rh and Pd atoms in the matrix will emit K X-rays, some of which are then absorbed by Pb and Pt, resulting in additional characteristic X-rays from these elements. The count rates from Rh and Pd are reduced by the presence of Pb and Pt, while the count rates from Pb and Pt are enhanced by the presence of Rh and Pd. The photopeak intensity of every element in the sample is affected by the concentration of all the other elements. The accuracy of each element's measured concentration depends on all the others. In a complicated sample, like this used automotive catalytic converter, this is a challenge. Moreover, light elements (silicon, aluminum, oxygen, carbon) represent >95% of an automotive catalytic converter. These materials absorb X-rays from the elements of interest. The absorption depends on the relative amounts of the light elements but these light elements cannot be directly measured this system. Figure 5 shows the measured photopeak intensity for Rh and Pt versus concentration for the two samples along with linear regressions. If matrix effects were negligible, the result would be a straight line through the origin. With only two samples, we will always get a straight, but notice that it does not go through the origin. The sample with high Rh and Pt concentration, SRM 2557, also has a high concentration of Pb, Ce, Ni, etc. These are presumably attenuating the Rh and Pt flux, leading to the error. Figure 5. Plot showing the photopeak intensity vs concentration for Rh and Pt in the samples. ANALYSIS METHODS Amptek's XRS-FP software has several different choices for quantitative analysis which are different approaches to the solution of Eqn. [1]. Once the spectra were acquired and processed, we applied several different quantitative methods and compared the results. These will be discussed here. The simplest option is the linear least-square approach. This method neglects inter-element effects. It assumes that M is unity so that each element can be Amptek Inc. 4

analyzed independently using a linear regression. It requires one to measure the photopeak intensities for known calibration standards and then applies the linear regression. As Figure 5 illustrates, for the case under consideration here, we will always get excellent results for a linear regression between the two points we have available (SRM 2556 and 2557) but this is not the appropriate method for these samples. Fundamental Parameters Sherman [ 1 ] wrote an equation which yields the intensity of the characteristic lines emitted by a sample of known composition. The Sherman equation considers primary and secondary fluorescence for a given incident X-ray spectrum and for a given configuration of the spectrometer. Inverting the Sherman equation lets one determine the concentrations of elements required to produce the measured set of intensities. The direct use of Sherman s equation is termed the Fundamental Parameters (or FP) method. Given the mathematical complexity of the true FP method, various simplified approximations are often used. Amptek's XRS-FP software can implement the FP method in a "standardless" mode. This mode uses theoretical equations to estimate both the calibration coefficients K and the inter-element effects M in Eqn. [1]. This is very convenient but its accuracy will be limited, due to simplifying approximations that are required and to simple tolerances on the system. Better accuracy is obtained if one calibrates the parameters. This can be done using multiple single element standards, by using a single multielement standard, or by using several multielement standard. If calibrations are only available for some of the elements, the other elements are analyzed using the standardless mode. The best analytical results are obtained when the calibration standards have a composition similar to that of the material to be measured. As mentioned previously, in this case one hour spectra were obtained from the two SRMs and used to calibrate the parameters, then a series of 5 min spectra from the sample SRMs were evaluated. Scattered Intensity Ratio Standard FP works well when all of the elements of interest have characteristic lines one can readily measure. However, in this case most of the sample is very low Z. The Al and Si lines cannot be measured very well so FP cannot accurately determine their concentration. But the ratio of backscatter peaks, scattered from the tube anode characteristic lines, is related to the mean Z of the target. By measuring this ratio, the software can estimate the mean Z and from this the attenuation. Two things are necessary for this approach. First, the tube has to create scattered K peaks, so the W anode will not work for this. For this AN-XRF-005 Rev B0 reason data were taken using a Mini-X with an Ag anode. Second, the XRS-FP software requires one to obtain a set of low-z standards and measure the spectra. A set of ten standards were prepared using common materials such as polyethylene, graphite, water, and table salt. Spectra were taken for these standards and the XRS-FP software fit the ratio of the Compton to Rayleigh peak intensities (C/R ratio) to the mean Z of the standards. Figure 6 shows the spectra while Figure 7 shows the data and its fit, along with a list of the standards. Figure 6. Spectra measured from low Z standards used to calibrate the SIR option of XRS-FP. 0 5 7 9 11 13 15 <Z> Amptek Inc. 5 C/R 25 20 15 10 5 NaCl 14.64 Al 13.00 PVC 12.00 Baking Soda 8.45 Water 7.22 Delrin 6.73 Sugar 6.70 Plexiglass 6.24 Graphite 6.00 HDPE 5.28 Figure 7. Plot showing the relationship between the Compton to Rayleigh intensity (C/R) versus mean Z. After the SIR calibration was carried out, one hour spectra were obtained to calibrate the FP parameters, then a set of 50, five minute spectra were obtained and were analyzed as with the W anode tube. Comparison Table 2 shows the results of the different FP methods with the error bars representing the standard deviation of the results, i.e. the precision of the measurements. The standardless method clearly demonstrates the worst accuracy. Its results are generally within a factor of two of the correct values. There can be applications where this is sufficient, for

example screening materials to identify certain elements at the order of magnitude level. The W anode tube gave much better results for Rh and Pd than the Ag anode tube, because the Rh and Pd K lines overlap the scattered Ag lines. The SIR analysis provides better accuracy for La, Cr, and Fe, which are the lowest energy lines analyzed here. The higher energy lines are comparable, for the two standards available here. Ag Anode W Anode NIST FP - Standards SIR FP - Stds FP- Standardless FP - Standards FP- Standardless Fe 8,000 8,135 + 176 7,930 + 157 5,391 + 142 7,658 + 94 5,305 + 146 Ni 468 + 25 457 + 24 345 + 24 462 + 21 361 + 17 Zn 600 612 + 9 614 + 9 1,271 + 46 594 + 7 1,279 + 46 Zr 300 302 + 4 302 + 4 574 + 31 310 + 3 560 + 32 Rh 51 + 1 65 + 17 65 + 17 141 + 37 47 + 4 101 + 12 Pd 326 + 2 348 + 23 344 + 22 814 + 67 341 + 5 783 + 47 Cd 103 + 29 99 + 27 103 + 29 3 + 8 4 + 9 Ba 100 150 + 107 167 + 119 2,670 + 1,867 177 + 89 2,739 + 1,351 La 7,000 8,178 + 1,795 6,710 + 1,458 4,696 + 792 3,385 + 746 5,481 + 932 Ce 10,000 10,242 + 454 10,467 + 455 5,563 + 413 10,426 + 337 5,484 + 320 Pt 697 + 2 726 + 17 724 + 17 1,131 + 51 695 + 12 1,115 + 44 Pb 6,228 + 49 6,366 + 70 6,300 + 69 9,772 + 409 6,288 + 64 9,723 + 413 Table 2. Results of the different quantitative methods applied to SRM 2556. 3 CONCLUSIONS This note shows one possible application of Amptek's EDXRF equipment: measuring the concentration of precious metals, particularly Rh, Pd, and Pt, in used automotive catalytic converters. This is a challenging measurement since it involves accurate measurement of elements present at tens to hundreds of ppm in a matrix which is mostly low Z but includes many higher Z elements. It is an example where the high energy resolution of the SDD is critical. This application also illustrates some interesting challenges in EDXRF. It shows how important matrix effects can be, it shows some of the different quantitative methods which can be applied, and it shows the trade-offs involved in selecting the energy and filtering of the excitation source. 1 Amptek Inc. 6