KS-70. Catheterization Table GENERAL



Similar documents
Equipment Specifications for FLAT PANEL DIGITAL (Digital Cardiac Cath-Lab Single/Mono Plane with Intra Vascular Ultra Sound)

PERFORM-X DIGITAL X-RAY SYSTEM PERFORM-X. with ceiling mounted tube support PERFORM-X

InForm Mobile Units. Selection. Equipment trolley, filing trolley Printer/PC trolley Overhead/demo trolley

MEDICAL IMAGING. 90/30 Remote Controlled RF System

Bringing good things ahead

MONDOATHENS BASKETBALL SET (Reference PK110)

HIGH PERFORMANCE MOBILE SURGICAL C-ARM KMC-950

Components. accessories

PLM series Permanent load lifting magnets

Video conference solutions

Catalogue. 2 Wheel Drive Tow Carts Model Part No Picture Description Packaging. info@helitowcart.com

Crane control unit KST 3

GE Healthcare. Lullaby Warmer. Because every baby deserves a high standard of care

NEW RANGE OF CABINETS DRIVIATM. Innovation at your service. THE GLOBAL SPECIALIST in electrical and digital building infrastructures

Installing Cisco TelePresence MX200 G2 - Wheel Base

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

ReadyKart Mobile Processing Station Instructions for Use

SOHOline and SOHO Slimline The SOHOline and SOHO Slimline offer a modular, sturdy and compact design

CYMAQ Marking System AS200 + DS7050 N-14

2013 Wireless Video Intercom INSTALLATION GUIDE

X-ray Imaging Systems

ClearView+ User Manual

DENSITY MEASURING SYSTEMS

DENTAL CHAIR AND UNIT SP- CIELA IMPORTANT

Circuit Breakers. NRC Series. NRC Series

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

TELESCOPE Motorized Lighting Suspension

Fredriksons conveyor systems handle goods with a width from 20 mm up to 600 mm.

Agila Ceiling Supply Unit Medical Supply Units

TECHNICAL INFORMATION

Clinical Solutions.

Actuator for modulating control AME 435

S 700 K point machine. Setting points reliably.

Electro-pneumatic control valves

Intexma Graphics (Pty) Ltd

900 series. Flat panel Floor stands. The 900 series Flat panel Floor stands.

Rack Installation Instructions

06 / Optional components. MAXDATA PLATINUM Server-Rack PLATINUM. [Product Guide]

VITOSOL r 200-T SP2A. VITOSOL 200-T Type SP2A

Compaq Rack Options and Accessories. Monitors and Keyboards

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

Video conference solutions

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Single Channel Loop Detector

46120-F0 Solar Energy Training System

User Manual. Studio Rail. Size Version

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

X-Mind. Instinct for perfection

Equipment Information

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION SOURCES

Adding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

COMPACT. Drilling COMPACT

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9

Laserlyte-Flex Alignment System

Video conferencing. solutions. Communication was never that easy,

BLADE S-MAX Cabinet for Blade Server

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH D MOOSBURG TEL FAX

ELS3 Electric Height Adjustment for sit-to-stand workplaces

Incubator with mechanical convection

VICKERS HARDNESS TESTER. HBS HBW Kc

Gantry Crane 1:87. Description. Packing contents. Unpacking. Roof assembly

HERZ-Thermal Actuators

DIGITUS Network & Server Cabinets. UNIQUE Series

CHAPTER 12 : OXFORD MERMAID & RANGER HOIST PRODUCTS

KNX Interface. User Manual PM00A00IRI

INTERNATIONAL HOCKEY FEDERATION PERFORMANCE REQUIREMENTS AND TEST PROCEDURES FOR HOCKEY BALLS. Published: April 1999

Switchboard system. NorLine 800

Introduction Body Specifications Technical Data Body Interior Rear Seats Center Arm Rest Child Seat Restraint...

CutMaster Major External Replacement Parts

Think of the environment before printing! Fax only contains page 1!

Uno 102. Product Description. Instruction Guide

InForm Tables and Base Cabinets

SERVER ROOM CABINET INSTALLATION CONCEPTS

Knürr Miracel. Knürr Miracel. 19 Network and Server Rack Platform 1.12 to

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Technical Information

Operating Instructions Drill rig DRU160

Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks

PS6500 Storage Arrays Rack Mount Instructions

Material test chamber with mechanical convection

EFC Frequency converters

Thyristor-controlled power supplies and battery chargers

ENGLISH FORK GUIDE 2013

Heating oven with mechanical convection

Colocation Rack Secure, Separate Server Hosting and Housing in Data Centers

SERVICE MANUAL. Corpus 3G. Seat system for electric wheelchair

MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances

Moving Magnet Actuator MI FFA series

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Sicuro pesa. intensive care. The basis of. Clinic Care Homecare Assist

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

Technocrane s. r. o. Podnikatelská 19 CZ Plzeň Czech Republic

1.1 DIMENSIONS AND WEIGHT PAG LOAD CENTRE FOR LIFTING PAG STORAGE CONDITIONS PAG. 2

GAM900/GAM900S. Acceleration precisely measured and safely monitored

Technical catalogue convectors POLAND 2012

Vario-Series Accessories

Transcription:

PD505-009A Catheterization Table KS-70 GENERAL This Catheterization Table KS-70, which is combined with X-ray high voltage generator, X-ray tube assembly, X-ray image system (Image Intensifier, Flat Panel Detector, X-ray TV camera), and contrast medium injector, etc. in a cardiovascular examination system, is a diagnostic table to perform X-ray fluoroscopy and radiography on the object in horizontal position. The KS-70 can be applied to the following application fields. (1) Cerebral angiography ( Cardiovascular angiography ( Abdominal angiography (4) Peripheral angiography

FEATURES (1) Low X-ray absorption CFRP tabletop The CFRP (carbon fiber reinforced plastic) tabletop achieves low X-ray absorption and provides excellent contrast image quality. ( 227 kg Patient load with additional 100 kg CPR support The table is capable of 227 kg patient load which is the largest in the industry. Furthermore, additional 100 kg are offered for the CPR (Cardio-Pulmonary Resuscitation) at CPR position. ( Wide patient coverage The KS-70, in combination with the Shimadzu C-arm Gantry, secures wide longitudinal patient coverage as well as transverse patient coverage. X-ray fluoroscopy and radiography can be performed from the head to toes, and from right to left. The light tabletop slide makes patient positioning easier. (4) Optimum tabletop working height The table offers the motorized tabletop elevation and the tabletop height from floor can be changed from 79 cm to 115 cm, which is helpful for the patient to get on/off the tabletop. Furthermore, the operators can obtain appropriate working height depending on their height. (* tabletop height is increased 2.5 cm in case of no pit on the floor.) (5) +180 / -90 deg. table rotation The table swivel from +180 deg. to -90 deg. is useful for the patient treatment at the time of emergency cases. +180 deg. opposite position enables dual-plane configurations which combines two different C-arms for two different applications to increase the room operation efficiency. (6) Two kinds of table-top shapes Two different tabletop shape is available depending on the patient size and expected applications. Standard tabletop shape can be used for universal use, and wide patient tabletop is useful for transradial or trans-brachial approach for less-invasive catheterization. (7) A variety of accessories/options to support angiographic procedures A variety of accessories and unique features are provided as standard or provided optionally. CONFIGURATION (1) Table base 1 set Holding the tabletop to permit its vertical and rotational movements, this unit is equipped with driving part and control part for the said movements. ( Tabletop unit 1 set This unit holds the tabletop to permit its longitudinal slide and transversal slide and is provided with a rail for mounting of various accessories on each side of tabletop. Also, the magnet lock brake mechanism is provided to fix the tabletop. ( Standard accessories Grip switch 1 set (Fig.1) Foot switch 1 set (Fig. (It is provided with foot switches for fluoroscopy and radiography.) Tabletop mattress 1 piece (Fig. Arm support (Carbon) 1 set (Fig.4) Arm support 1 pair (Fig.5) Drip stand 1 set (Fig.6) Cable hook 6 pieces (Fig.7) 2

1) Lock release switch Accessory rail Knob 540 1) Carbon Plate Band Mattress Grip 1000 Fig.1 Grip switch to Connector Fig.4 Arm support (carbon) 1) In case of combination with single-plane C-arm. 1) Fluoroscopy switch ( ) Exposure switch ( ) 100 800 In case of combination with bi-plane C-arm. 1) Frontal C-arm fluoroscopy switch ( ) Exposure switch ( ) Lateral C-arm fluoroscopy switch ( ) Fig.5 Arm supports Fig.2 Foot switch Fig.3 Tabletop mattress Approx. 1000~1500 4) 1) 1) Slider Knob Holder 4) Knob Fig.6 Drip stand Fig.7 Cable hook 3

OPTIONAL ACCESSORIES Peri console 1 set (Fig.8) (Only for I.I. system) Arm grip 1 set (Fig.9) Sub rail 1 set (Fig.10) Driving unit for peripheral angiography 1 set Injector head mount (for catheterization table mounting MARK-V) 1 set Base plate (to reinforce the floor) 1 set Arm support(for Radial/Brachial Puncture) 1 set(fig.11) Full cover mattress 1 set(fig.1 1) 4) Fig.10 Sub-rail (Option) For Left Hand 1) Start point return switch Two position registration switch for constant step radiography Multi position registration switch for flexible step radiography 4) Reset switch 7 For Right Hand Fig.8 Peri Console (Option) 275 18 Fig.11 Arm support (carbon)(option) For standard tabletop 25 28 41 170 200 90 ±1 For wide tabletop Fig.9 Arm grip (Option) Fig.12 Full cover mattress (Option) 4

SPECIFICATIONS KS-70 Item Description Tabletop size Standard tabletop 240 Wide tabletop 550 700 450 700 1150 2880 240 1150 2880 Attenuation equivalent for table Distance between tabletop surface and floor Longitudinal slide of tabletop Transversal slide of tabletop Vertical movement of tabletop Rotation of column Driving unit for peripheral angiography (option) Allowance load mass (Based on IEC60601-2-4 Full stroke Locking system Stroke Locking system Stroke Speed Stroke Locking system Number of steps Step speed Exposable range Exposure interval Stopping accuracy 0.7mm Al. Eq. (150mm inside from the tip of the table) 0.8mm Al. Eq. (800mm inside from the tip of the table) 79 to 115cm, continuously variable (81.5 to 117.5cm when the pit is not provided on the floor) 135cm Manual OFF brake (magnet locking system) to be controlled with grip switch ±15cm Manual OFF brake (magnet locking system) to be controlled with grip switch 36cm Motor-driven 13.2mm/s (50Hz), 15.8mm/s (60Hz) CW90º/CCW180º Manual OFF brake (solenoid locking system) to be controlled with switch provided on side of table 6 steps maximum saved (for peripheral DSA option) 1.6sec/25cm 135cm (at maximum) 2sec. (when the step interval is 25cm) ±1mm 227kg (Patient must lay on the tabletop) +100kg (for CPR, at CPR position) INSTALLATION RELATED Installation related Outline dimensions 4230mm 1200mm 1250mm (Depth Width Height) (KS-70 only) Mass Approx. 350kg Power requirements Single phase 100V, 0.5kVA, 50/60Hz (*Note) Three-phase 200V, 1kVA, 50/60Hz Note: The aforementioned specifications are subject to change for further improvement without prior notice to you. * Note: The power should be supplied from output of a reinforced insulation transformer. 5

DIMENSIONS Remarks * Every value in this Product Data Sheet is a standard value, and it may vary a little from the actual at each site. * The appearances and specifications are subject to change for reasons of improvement without notice. * Certain configurations may not be available pending regulatory clearance. Contact your Shimadzu representative for information on specific configurations. SHIMADZU CORPORATION. International Marketing Division 3. Kanda-Nishikicho 1-chome, Chiyoda-ku, Tokyo 101-8448, Japan Phone: 81(3219-5641 Fax: 81(3219-5710 URL http://www.shimadzu.com Shimadzu Corporation Medical Systems Group has been certified by TUV Rheinland as a manufacturer of medical equipment and systems in compliance with ISO9001: 2000 Quality Management Systems and EN ISO13485: 2000 Medical Equipment Quality Management Systems.