RESIDENTIAL MASONRY A BEST PRACTICES GUIDE



Similar documents
Ver. 2. Guide to. Inspecting Residential Brick Veneer

LAYING BLOCK AND BRICK

Superform Products Ltd.

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

1. Concrete: T W L / 27 = Concrete C.Y. Multiply Feet Thickness x Feet Width x Feet Length / 27 = Cubic Yards.

Asphalt Shingle Application Requirements

8/18/14. Introduction to. Framing. Terminology and Concepts

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

INSTALLATION OF A BAY WINDOW

COMMONLY USED RESIDENTIAL BUILDING CODES

Mark Cramer Inspection Services, Inc.

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS

GreenGuard Housewrap Installation Guide

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Dimensioning and Estimating Brick Masonry

March 14, Installation of Bay, Bow and Garden Windows

INSTALLATION INSTRUCTIONS for Vinyl Windows with Integral Nailing Fin (JII001)

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council RETAINED ON U.S.

Important Information for Installer & Homeowner

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

Brick Veneer Construction

Residential Deck Safety, Construction, and Repair

Chapter 6 ROOF-CEILING SYSTEMS

Certification: Building Plans Examiner. Exam ID: B3

4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.

STRUCTURAL ASSESSMENT. Full Metal Jacket Building 0 Prince Street, Alexandria, VA

Chapter 3 Pre-Installation, Foundations and Piers

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

EAST LYME HIGH SCHOOL

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

Water Penetration Resistance - Construction and Workmanship

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

K2 STONE NATURAL VENEER

Manufactured Stone Veneer Installation Instructions

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

Best Barns USA Assembly Book

Photo courtesy of Delta Stone, Heber City, UT. Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick

Tundra Series Windows January 2016

POST AND FRAME STRUCTURES (Pole Barns)

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

Foundation Code compliance and Best Practices By Michael Coello

REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION

SECTION STORM DRAINAGE SYSTEM

PART 1 GENERAL 1.1 SECTION INCLUDES

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

ENERGY STAR Qualified New Homes Thermal Enclosure Checklist. Water Management Checklist. Eli Caudill

Chapter. Restoration of Damaged Structures

ISO Types 1-6: Construction Code Descriptions

Chapter 36 - STRAW BALE CONSTRUCTION SECTION PURPOSE. SECTION SCOPE. SECTION DEFINITIONS.

What you need to know about concrete block basement construction.

Brick Veneer/Steel Stud Walls

Durapax Coal Tar BUR Application Guide

Building Condition Assessment: North Howard Street Baltimore, Maryland

Ceramic Glazed Brick Exterior Walls

CHAPTER 7 WALL COVERING TABLE R702.1(1) THICKNESS OF PLASTER

City of Tucson and Pima County Arizona Building Code Appendix Chapter 72 Straw-Bale Structures

Cost Comparisons for Common Commercial Wall Systems

Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details

Thin Veneer Stone Installation Guide

The Difference Between Cast Stone and Adhered Manufactured Stone Masonry Veneer

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

BILL OF QUANTITY FOR THE WORK OF "REPAIRING OF CIVIL & PLUMBING WORKS INSIDE AND OUTSIDE OF THE WORKSHOP"

ICC-ES Evaluation Report Reissued September, 2010 This report is subject to re-examination in one year.

Custom 30 x 20-8 Garage Plan Plan #g233 By SDS-CAD Specialized Design Systems

Page & Turnbull imagining change in historic environments through design, research, and technology

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows

Pre-Drywall Inspection Report

SG Series 65mm Frame Windows (Fixed Lite Window Illustrated)

Installation Solutions for: Manufactured Stone, Natural Thin Veneer, and Thin Brick ARCHITECTURAL SPECIFICATIONS / CAD MODELS TVISTM WARRANTIES

Patio Covers / Carports

Adding Brick Veneer to Existing Construction

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

Comment Form on Proposed Gut Rehabilitation Alternatives

Additions and Alterations

6 RETROFITTING POST & PIER HOUSES

Elevating Your House. Introduction CHAPTER 5

INSTALLATION INSPECTION GUIDE FOR 3RD PARTY INSPECTORS FOR PAREX USA EXTERIOR INSULATION AND FINISH SYSTEMS

Introduction...COMB-2 Design Considerations and Examples...COMB-3

EXISTING MASONRY WALL TO REMAIN (TYP.). EXISTING PARTITION TO REMAIN PROVIDE 3'-3" W. X 8'-0"H. NEW PELLA WINDOWS AS INDICATED ON PLANS. (TYP.

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

PDmB, Inc. Definitions

Lesson Plan Course Title: Construction Technology

FACT SHEET: HYDRATED LIME FOR MASONRY PURPOSES

HfHMD uses LP SmartSide siding and trim.

Building Construction. Structural Systems 1. Load-bearing wall construction 2. Skeleton framing 3. Combination of the two

STANDARD OPEN PATIO COVER

1/9/2013. Terminology Calculating Heat Transfer Code Requirements Design Examples and Sustainability

Natural Thin Stone Veneer

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs

Building Construction. Lightweight construction. Conventional Construction

INSPECTION PROPERTY ADDRESS: Fort Bend County, Texas

0331 Brick and block construction

Most of my work is in exterior remediation, both as a builder. Adhered Concrete Masonry Veneer To avoid water damage, treat faux stone like stucco

Residential Inspection Guidelines

Storage Store the siding in a dry and ventilated area. Do not place it directly on the ground. Always cover the siding after a day s work.

Residential Foundations and Basements

DENVER MODEL 30 X 30 SPECIFICATIONS

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

Sun Windows General Information Sun New Construction Window Installation Instructions

Transcription:

RESIDENTIAL MASONRY A BEST PRACTICES GUIDE Build With Brick Build With Boral

CONTENTS BRICK :01 MASONRY CEMENT :03 MASONRY SAND :04 WALL TIES :05 STEEL LINTELS :07 DRAINAGE WALL SYSTEM :09 FLASHING :11 WEEP HOLES :17 The information provided in this Best Practices Guide is intended to assist the installer in the proper installation of Boral Bricks, Inc. products. It is not intended to replace applicable local building codes or industry standards. Installation of the products in accordance with such codes and standards is the sole responsibility of the installer, and Boral Bricks, Inc. assumes no liability for products installed improperly or not in conformity with such codes and standards.

01: BRICK BRICK SIZE DIMENSIONS BRICK PER SF SF PER 1000 WEIGHT PER SF (L x H x D) (installed) (installed coverage) (installed, non-solid) Modular 7 5/8" x 2 1/4" x 3 5/8" 7.0 143 40 lbs. Queen 7 5/8" x 2 3/4" x 3" 6.0 182 30 lbs. Engineer 7 5/8" x 2 3/4" x 3 5/8" 6.0 182 40 lbs. Princess 8 3/4" x 2 3/4" x 2 3/4" 6.0 182 30 lbs. King 9 3/4" x 2 3/4" x 2 3/4" 5.0 200 30 lbs.

BRICK :02 TYPES OF MORTAR JOINTS 1. CONCAVE JOINT 5. FLUSH JOINT 2. V JOINT 6. RAKED JOINT 3. GRAPEVINE JOINT 7. EXTRUDED JOINT 4. WEATHERED JOINT 8. STRUCK JOINT Types of mortar joints are listed in order from highly-recommended to not recommended based on mortar compaction and water penetration.

03: MASONRY CEMENT TYPE APPLICATION CEMENT COMPRESSIVE STRENGTH WORKABILITY CONTENT STRENGTH (psi) M* Below grade (block) High 2500 High Limited S Structural walls 1800 N General use, veneer 750 O* Partitions, interiors 350 Type N balances strength and workability and is highly weather-resistant. K* Low-strength interior Low 75 Low Very good * non-stock items Masonry cement adds almost no volume to a prepared mortar, it simply coats the sand particles. [.33 cubic feet (CF) of cementitious materials and.99 CF of sand will make 1 CF of mortar] Mix Mortar Using 1:3 Ratio 1 part masonry cement + 3 parts sand + appropriate water = mortar 1 bag masonry cement (1 CF) 4 five-gallon pails + + appropriate water = of sand (3 CF) 3 CF mortar The required shovel count varies by operator technique and shovel type, so a fivegallon pail or 1CF box should be used initially to determine an accurate count for 3CF of sand. The amount of water required depends on conditions and brick absorption. Estimate 7-9 bags of masonry cement per 1000 bricks of any size. Estimate 3 bags of masonry cement per 100 (8" x 8" x 16") concrete block.

MASONRY SAND :04 Cubic yard (CY) of sand = 1.2 tons of sands * 1 ton of sand will lay approximately 250 concrete block.* 1 ton of sand will lay approximately 1000 brick.* Normal jobsite delivery of bulk sand is approximately 18 tons or 15 CY* * these are rough estimates

05: WALL TIES 22 GAUGE WALL TIE NOMINAL 1" AIR SPACE END OF TIE MUST BE BETWEEN HALF THE BRICK THICKNESS AND 5/8" FROM THE BRICK FACE

WALL TIES :06 22 gauge corrugated wall ties are only used on wood stud construction. Nails should be sized 8d or larger, cement-coated or galvanized (8d nails are 2.5" long). Ties should be spaced every 16" vertically and every 16" or 24" horizontally depending on stud spacing. This supports most codes which require one wall tie for every 2.67 SF of wall area. Ties must be nailed into studs and are typically installed as the mason works up the wall with brickwork. 54 ties per 1000 modular brick, 68 ties per 100 oversize brick. Nail as close to bend as possible for maximum lateral strength.

07: STEEL LINTELS A lintel is a support member that spans a door or window opening in a masonry wall. Lintels can be made from pressed steel, angle iron, I-beams, concrete, stone, etc. The following best practices pertain to angle iron used for lintels in residential construction: MASONRY OPENING LINTEL DIMENSIONS OVERHANG (EACH SIDE) Up to 8' 3" x 3" x 1/4" 4" 8' to 12' 3" x 5" x 5/16" 4" to 8" 12' to 16' 3" x 5" x 5/16" 8" to 12" Code requires no less than 4" bearing on each end of lintel, regardless of length. Temporary bracing of lintels over large masonry openings, such as garage doors, prevents sagging and possible cracking while the mortar reaches maximum strength. Lintels are also available prepunched for lag bolt attachment to wood framing when dictated by code. Lintels are available galvanized or primed to prevent or minimize rust. For foundation vents, steel flat bar may be required as a lintel when the vent is not self supporting.

STEEL LINTELS :08

LIFT FOR RESIDENTIAL BRICK DRAINAGE WALL SYSTEM ILLUSTRATION. FOR MORE INFORMATION CONTACT YOUR LOCAL BORAL BRICKS SALES REP.

RESIDENTIAL BRICK DRAINAGE WALL SYSTEM BRICK VENEER THROUGH-WALL FLASHING LINTEL THROUGH-WALL FLASHING WOOD STUDS 22 GAUGE GALVANIZED CORRUGATED METAL TIE GALVANIZED OR CEMENT-COATED NAIL INSULATION GYPSUM BOARD SHEATHING 1" AIRSPACE WEATHER RESISTANT BUILDING PAPER WEEP HOLES SUBFLOOR SOLE PLATE FLOOR JOIST HEADER SILL PLATE THROUGH-WALL BASE FLASHING SILL SEALER BITUMINOUS WATERPROOFING 4" MINIMUM OVERLAP 8" MINIMUM RISE FOUNDATION WALL

11: FLASHING HOUSE WITH FLASHING LOCATIONS 06 HOUSE WITH FLASHING LOCATIONS BLACK LINES INDICATE LOCATIONS WHERE THROUGH-WALL FLASHING AND WEEP HOLES ARE REQUIRED.

FLASHING :12 ROOF INTERSECTION DETAIL THROUGH-WALL FLASHING COUNTER FLASHING (DECORATIVE) BASE FLASHING ROOFING

13: FLASHING WINDOW HEAD DETAIL THROUGH-WALL FLASHING STEEL ANGLE LINTEL WEEP HOLE CAULKING WINDOW ASSEMBLY

FLASHING :14 WINDOW SILL DETAIL WINDOW ASSEMBLY CAULKING THROUGH-WALL FLASHING INSTALLED BEFORE WINDOW SUPPORTING MORTAR WEEP HOLE

15: FLASHING BASE OF WALL DETAIL EXTERIOR SHEATHING WITH BUILDING PAPER THROUGH-WALL FLASHING WEEP HOLE FULL COLLAR JOINT

FLASHING :16 END DAM DETAIL THROUGH-WALL FLASHING ADDED PRIOR TO WINDOW INSTALLATION END DAM FORMED BY FOLDING FLASHING WEEP HOLE SILL BRICK SLOPED FOR DRAINAGE, MORTAR JOINTS TOOLED FIRMLY

17: WEEP HOLES Must be positioned in head joint directly on through-the-wall flashing. Space weep holes every 3-4 brick. Fiber, vents and cells are available in colors to match mortar. Other options available (not pictured): cotton rope wick, open head joint, plastic tubing.

WEEP HOLES :18 EXAMPLES OF WEEP DEVICES SYNTHETIC FIBER WEEP WEEP TUBE WITH SCREEN AND ROPE WICK PLASTIC WEEP VENT WEEP CELL

1.800.5BORAL5 www.boralbricks.com 2006 Boral Bricks, Inc.