Standing Seam Roof Systems

Similar documents
SECTION STANDING SEAM METAL ROOF

SECTION PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK

SECTION STANDING SEAM METAL ROOFING

The Butler MR-24 Standing Seam Roof Difference. A comparison between metal roof systems

metal Duil~ing manufacturers Association

Nucor VR16 II TM Vertical Rib Standing Seam Roof System

GUIDELINE SPECIFICATIONS

CHAPTER 7: Building Systems ROOFING SYSTEMS

PRODUCT SPECIFICATIONS

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

TABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"

VERTICAL LOCK Table of Contents

Residential Roofing Guide

238T Standing Seam Metal Roof System (SSMRS)

Preformed Metal Roofing and Siding

SECTION PREFORMED METAL STANDING SEAM ROOFING

Discount Direct Metal Roofing Plus Rib Roofing Panels Installation Instructions

AIA PRESENTATION. Standing Seam Metal Roofing Seminar SSRLU2B 1 LU/HSW Hour

INSTALLATION MANUAL For Grand Rib-3 / Multi Purpose / & Classic Rib Roofing Panels

STANDARD PROCEDURES FOR INSTALLATION OF METAL ROOF SYSTEMS

MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)

Drexel Metals Inc. DMC 100SS 16oz min. Copper Mechanical Seam Metal Roof System over Plywood

Slim Seam Architectural Design Manual

Asphalt Shingle Application Requirements

Double-Lok. Technical/Installation Information

A. Double lock standing seam, single element, metal roof panels.

Technical Installation Information

COLORADO MODEL. 35 x 65 SPECIFICATIONS

Technical Installation Information

CHAPTER VII. TITLE: STANDARDS FOR NEW ROOFING July 2015 CONSTRUCTION, RE-ROOFING CONSTRUCTION AND ROOFING SYSTEM GUARANTEE REQUIREMENTS

4572 N Old US 31, Rochester, IN Toll Free: Fax: DETAIL MANUAL. and guide to Ramco Supply products

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

DENVER MODEL 30 X 30 SPECIFICATIONS

Holiday Inn Express & Suites Covington (Newton County) 1. Standing-seam metal roofing, custom fabricated.

INNOVATIVE. ADAPTABLE. ENERGY EFFICIENT.

ABSeam Panel Overview and Installation Instructions

ATLANTA MODEL SPECIFICATIONS

SECTION METAL ROOF SYSTEM

STRUCTURAL STANDING SEAM ROOF SYSTEMS

SECTION METAL ROOF & WALL PANELS

Metal Building Systems Installation and Flashings & Details Guide. Table of Contents

Table of Contents. Western States RustWall Wall and Soffit Panels Installation, Flashings & Shop Drawing Detail Guide

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

LokSeam. Design/Installation Information. This booklet includes: Trims and Accessories Design and Installation Information

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

HHS J.W. Peavy Center Exterior Walls Waterproofing and Roof Replacement Project WBS # H SECTION STANDING SEAM METAL ROOFING

Installation Manual for STANDING SEAM ROOFING

stand the tests of time, & economics

BRIDGE & SUPPLY COMPANY. Installation Guide. Ultra Includes:

ROOFING APPLICATION STANDARD (RAS) No. 150 PRESCRIPTIVE BUR REQUIREMENTS

SECTION METAL WALL PANELS

Screw Patterns Roof & Walls TR-36 MD-36 TSM-32. PBR-Panel

September 3, Ric Boyd, Public Works Director Ketchikan Gateway Borough 344 Front St. Ketchikan, AK 99901

Rouse Life Sciences Roof Repair or Replacement SECTION

CSI Specifications MR-24 ROOF DETAILS MR-24 Roof Conditions.. Y MR-24 Roof Ridge With Thermal Spacer Block Y

SECTION STANDING SEAM METAL ROOFING

Mechanically Seamed Roof System Design / Installation Information

Section Page Section Page

SECTION STANDING SEAM ROOF PANELS

Residential Metal Roofing

GUIDE SPECIFICATION. Manufacturer: DECRA Roofing Systems, Inc.

Springlok Flashing System

DETAIL MANUAL. for Standing Seam East 23rd Street Chattanooga, TN South Lee Hwy. Cleveland, TN 37311

TARRANT COUNTY DETAIL STANDARDS

Steel Panel Frame. Exterior Steel Sheeting. Optional Rigid Insulation. Optional Steel Insulation Liner

BURNISHED SLATE COVER PHOTO: SLATE GREY

PREMIUM LAMINATED ASPHALT SHINGLES Dallas, TX Tuscaloosa, AL Phillipsburg, KS

Snap-Loc. Installation Guide

CB-100 CB-150 CS-100 SL-100 SL-150 SLZ-1000


Coastal Metal Service

PART 1 GENERAL 1.1 SECTION INCLUDES

GUIDE SPECIFICATION. Manufacturer: DECRA Roofing Systems, Inc.

PERFORMANCE TEST REPORT. Rendered to: ARCHITECTURAL METAL SOLUTIONS, INC.

SECTION PREFORMED METAL ROOF PANELS

General Instructions and Guidelines

Classic Products, Inc. ClickLock Standing Seam Installation Manual

CENTRIA SRS3 Structural Standing Seam Metal Roof Panels

METAL BUILDING SYSTEMS

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof

ROOF FLASHING SPRINGLOK FLASHING SYSTEM FEATURES & BENEFITS PRODUCT DESCRIPTION

DIVISION 07. Architectural Sheet Metal. Weathertight Warranties. Rollforming Equipment. 50+ Years of SSMR, Installation & Technical Experience

What makes DECRA Roofing Systems unique?

SECTION ROOFING TILE

Product Catalog. Extreme Roofing, Inc Rt. 982 Mammoth, PA

HERITAGE WOODGATE LAMINATED ASPHALT SHINGLES Dallas, TX

METAL ROOF & WALL SYSTEMS

SECTION STANDING-SEAM METAL ROOF PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS

Metal Roofing Practical Design

City of San Diego, CWP Guidelines

PBR & R Panel. Table of Contents

ROOF ASSEMBLIES AND ROOFTOP STRUCTURES

TremLock Metal Roofing and Wall Solutions

SL-16. Concealed Fastener System. This booklet includes: Trims and Accessories Design and Installation Information

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

metals LLC Metal roofing ON-DEMAND

Larry Haight's Residential Roofing Co, Inc NE 95th Street Redmond, Washington Phone: (425) Fax: (425)

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Architectural. Roofing. Basis of Design

Transcription:

Standing Seam Roof Systems REAL PEOPLE. REAL PRODUCTS. REAL SOLUTIONS. www.a-s.com

Building Benefits You Can Expect From A&S Materials Standing Seam roof panels weigh a relatively modest 11/2 pounds per square foot. When long life is required for unpainted products, A&S Building Systems offers Galvalume+, an aluminum-zinc alloy coated steel with a coating of 55% aluminum, 43.5% zinc and 1.5% silicon by weight applied to the steel substrate by the hot-dip process in accordance with ASTM A-792. Warranties A&S stands behind its Standing Seam with an industry leading comprehensive optional warranty assuring color coating for Signature 300 painted panels, as well as fade and chalk resistance. This warranty provides protection for up to 25 years against blistering, peeling, cracking, chipping, excessive color fade and chalk. Maintenance Signature 300 finishes offer long life, durable fluorocarbon exterior coating that resists chipping, pitting and peeling year after year. Standing Seam assures adequate drainage from rain and snow, effectively solving ponded water problems, leaks and other related troubles commonly associated with flat built-up roofs. Tolerance Roof leaks can be caused by the natural forces of expansion and contraction. The Standing Seam system is installed using special lip assemblies that allow for roof movement. This system is designed to handle thermal shock and therefore won t crack, blister, absorb moisture or require painting, patching or caulking usually needed with ordinary non-metal roof systems. The Standing Seam systems carry the highest rating awarded by Underwriters Laboratories for wind uplift: the Class 90 rating. Galvalume+ is the trademark of BIEC.

A&S Building Systems offers Ultra-Dek and Double-Lok systems. Both are constructed to provide a high degree of weather-tightness and have been tested by independent laboratories in accordance with ASTM E283 and E331 (for water penetration and air infiltration). To guard against leakage, gables finish in a 3 high standing seam, never in the flat valleys of the roof where leakage is most likely to occur. (This is true even for buildings that are out of square by up to 4.) No panel penetration is required over the building envelope other than at the endlaps, which are connected by a compression joint specially designed to seal out the elements. Furthermore, panel sidelaps arrive at the job site containing a pre-applied sealant that also contributes to the Standing Seam roof systems weathertight construction. Standing Seam roof systems come with an optional 20-year limited warranty for weather-tightness. Custom Designed & Fitted Panels Standing Seam Metal Roof Systems are backed by engineering support to ensure that each roof is right for each building. Panels can be custom designed to fit the size, style and special features of almost any commercial structure. 3/8 Thermal Block [1 3/8 Optional] Clip Factory Installed Gasket Sliding Tab Self-Drilling Screws Standing Seam Roof Panel Ultra-Dek System Our Standing Seam line offers snap and machine systems. Both are constructed to provide a high degree of weather-tightness and have been tested by independent laboratories in accordance with ASTM E283 and E331 [for water penetration and air infiltration]. To guard against leakage, gables finish in a 3 high standing seam, never in the flat valley of the roof where leakage is most likely to occur. [This is true even for buildings that are out of square by up to 4.] Double-Lok System No panel penetration is required over the building envelope other than at the endlaps, which are connected by a compression joint specially designed to seal out the elements. Furthermore, panel sidelaps arrive at the job site containing a pre-applied sealant that also contributes to the Double-Lok system s weathertight construction. Double-Lok roof systems come with an optional 20 year limited warranty for weather-tightness. The Metal Roof Systems That Stay on Top

specifications 1. Scope of work The following is a description of the metal roof as per the contract drawings. Panels, flashing, clips, ridge material, endlaps and fasteners shall be as described here and in the contract drawings unless otherwise approved. The roof support (structural) system and counter flashings are not included in this section. 2. Panels Panels shall be UL90 rated, rollformed, 24 gauge (minimum) structural quality aluminum zinc alloy coated, steel sheet complying with ASTM A-792. GalvalumeTM sheet steel shall have a minimum of class AZ-50 coating both sides and a minimum yield stress of 50,000 PSI. 2.2 Panels shall be in 24 widths (as per contract drawings) with a 3 high rib on each side. 2.3 One side of the panel shall be female in configuration, suitable to accept the other male side, and form a locking assembly. 2.4 Panels shall be factory notched at both ends so that field installation can commence from either end or side of the building. 2.5 Panel sidelaps shall have a factory applied, hot melt mastic (see sealants and closures). 3. ENDLAPS 3.1 Mastic (see sealants and closures) shall be applied between panels and secured with panels and back up plate to form a compression joint. 4. FASTENERS 4.1 Eave - #14 X 1 ¼" self-drilled with neoprene washer 4.2 Endlaps - #14 X 1 self-tapper with washer 4.3 Ridge - #14 X 1 ¼" self-driller with neoprene washer 4.4 Clips to purlin - #1/4 X 14 X 1" self driller with washer 4.5 Clips to bar joist - #12-24 X 1 ¼" self-driller with washer 4.6 Clip to panel - 14 X ⅞" Lap Tek with neoprene washer 5. CLIPS All clips shall have factory-applied mastic and be designed so that movement between the panel and the clip does not occur. 5.1 Utility clips-shall be 3 in height, to be used when insulation is not required. 5.2 Low fixed clips-shall be 3 ⅜" in height providing a ⅜" clearance for insulation between the panel and the purlin or joist to reduce water ponding on low pitch roofs. (Not available for machine system.) 5.3 High fixed clips shall be 4 ⅜" in height to accommodate a 1" thermal space for added insulation at the purlins. (Not available for machine system.) 5.4 High or low floating expansion clips shall be either 3 ⅜" or 4 ⅜" in height (see contract drawings). Floating clips shall provide minimum of 2" travel to allow for expansion and contraction. 6. SEALANTS AND CLOSURES 6.1 Factory-applied sealant used in panel sidelaps shall be foamable hot melted mastic sealant, Lastomer, FM 100 or equal. 6.2 Field-applied sealant used at the endlaps, eaves, ridge assembly and gable flashings shall be Lastomer Isobutylene tripolymer of 100% solids. This isobutylene based elastomeric tape sealer shall be furnished in roll form or pre-cut to length and is formulated without asbestos fillers. Sealant size, shape and quantity to be as per roof system manufacturers standards. Sealant is to be manufactured and packaged with pre-applied silicone treated release backing paper to facilitate rapid and clean application with precise control of tape placement and sealant volume. 6.3 Outside closures shall be manufactured from the same materials as the roof panels. 6.4 Inside closures shall be 18 gauge metal. 7. FLASHING AND TRIM 7.1 Flashing at the rake (parallel to roof panels) and high eave shall not compromise the integrity of the roof system by allowing movement due to thermal expansion and contraction. (This applies to floating systems only.) 7.2 The panel manufacturer shall supply the flexible membranes if applicable. 7.3 All trim and flashing shall be manufactured from GalvalumeTM steel sheet, whether prepainted or bare. 8. INSTALLATION 8.1 Erection of the roof systems shall be in complete accordance with the manufacturers erection manual. 8.2 The erection manual shall include procedures and designs to accommodate the out-of-square and out-of-plumb conditions that normally occur in construction. For complete and in depth specification data on all components of the Standing Seam System contact A&S Buildings Systems. Galvalume is the trademark of BIEC.

battenlok hs The BattenLok HS (High Strength) standing seam roof system is the most proven design on the market. It has been installed on thousands of building projects all over the world. The Advantages of BattenLok HS include the aesthetically pleasing architectural design with vertical ribbed seams, which are easily custom flashed. BattenLok HS is good not only for hips and valleys, but also for turndown mansards. The panels can be turned down over the eaves to form a wall panel appearance. A unique feature of the BattenLok HS is sidelaps that aremechanically seamed with an electric seamer for a sure lock. This system features easy to handle 16 wide panels with over 50 years of service in the market place. The proven durability and performance of the BattenLok HS panel, with the factory installed mastic and swaged endlaps ensures weather-tightness. BattenLok HS is a structural panel that spans up to five feet on purlins, or can be used as an architectural panel on plywood and felt substrate. BattenLok HS is a flat panel with vertical ribs creating no voids, therefore no eave closure plugs are required. BattenLok HS is designed to meet the ever changing AISI specifications and other industry codes. RIDGE DETAIL ENDLAP DETAIL

FEATURES & SPECIFICATIONS BattenLok HS panels are 16" wide flat profile standing seam panels. Designed for reroofing existing buildings or roofing new ones of any type, the panels have 2" high ribs and are machine joined at the edges with a mechanically locking seamer. Lengths up to 45' are available, longer panels may be ordered. BattenLok HS panels are available in 24-gauge zinc aluminum alloy coated steel, 50,000 psi minimum yield strength. Signature 300 fluorocarbon coating is formulated with Kynar 500 polyvinylidene fluoride [70% of resin solids]. Kynar 500 is a registered trademark of Atochem North America, Inc. ICBO APPROVAL BattenLok HS roofing system details, engineering calculations, computer printouts and data have been examined by the ICBO Evaluation Service, Inc. and have been found to comply with the 1997 Uniform Building Code. Panel Size: 12 & 16 inches wide, 2 inch high standing seam Gauge: 24 [other gauges are non-standard] Substrate: Galvalume Warranty: 20-year available Sealant: Factory applied Insulation: Can accept up to 6 inches blanket fiber glass and 1 inch board thermal blocks Seamed Roof is mechanically seamed in the field Wind Uplift UL 90 rated Concealed Clips: Available in either fixed or floating Ideal Retrofit Roof System Superior strength-to-weight ratios

CONSTRUC- TION NUMBER PANEL WIDTH (IN.) GAUGE CLIP TYPE CLIP SPAC- ING SUBSTRATE UL-2218 IM- PACT RESIS- TANCE UL-263 FIRE/ RATING UL-580 RATING 90 16" 24 min * 5'-0 1 16" Open Framing Class 4 Class A Class 90 176 16" 24 min N/A 5'-0 ¼" Open Framing Class 4 Class A Class 90 180 16" 24 min ** 5'-0 ¼" Open Framing Class 4 Class A Class 90 238B 16" 24 min ** 2'-6" Composite System Class 4 Class A Class 90 437 16" 24 min ** 5'-0" Plywood Class 4 Class A Class 90 449 16" 24 min * 5-0 Open Framing Class 4 Class A Class 90 451 16" 24 min * 2'-0" Composite System Class 4 Class A Class 90 452 16" 24 min * 2'-0" Composite System Class 4 Class A Class 90 487 16" 24 min ** 4'-0" Composite System Class 4 Class A Class 90 *Fixed or Floating ( high or low) ** Fixed or Floating ( high, low, or utility) Subject to change without notice NOTES: 1. 2. 3. 4. 5. Test procedures are in accordance with Underwriters Laboratories Standard UL-580 under Tests For Uplift Resistance of Roof Assemblies. A detailed installation method is available for each Construction Number above and can be found in the UL Roofing. Materials and Systems Directory. The panels must be installed in a certain manner to achieve the published results. The panel qualifies for a Class A fire rating in compliance with Underwriters Laboratories Standard UL-263 when installed over a non-combustible substrate. A Class C fire rating can be obtained over a combustible deck. The panel system qualifies under the following Fire Resistance Design Numbers: P225, P227, P230, P237, P265, P268, P508, P510, P512, P701, P711, P717, P720, P722, P726, P731, P734, P736, P801, P803, P814, P815, and P819. Refer to the UL Fire Resistance Directory for specific construction methods and hourly ratings. BattenLok HS panels carry a Class 4 rating under UL-2218 Test Standard For Impact Resistance. Underwriters Laboratories Approval EAVE CONDITION WITH GUTTER RAKE DETAIL

A&S Building Systems 1880 Hwy. 116 P.O. Box 53 Caryville, TN 37714 P: 800.274.2100 or 865.426.2141 F: 865.426.2011 sales-marketing@a-s.com Descriptions and specifications contained herein were in effect at the time this publication was approved for printing. In a continuing effort to refine and improve products, A&S reserves the right to discontinue products at any time or change specifications and/or designs without incurring obligation. To ensure you have the latest information available, please inquire or visit our website at www.a-s.com. Application details are for illustration purposes only and may not be appropriate for all environmental conditions, building designs or panel profiles. Projects should be designed REAL to conform PEOPLE. to applicable REAL building codes, PRODUCTS. regulations and accepted industry practices. If there is a conflict between this manual and project erection drawings, the erection drawings will take precedence. www.a-s.com