id led 4" square housing FL44 LUMINAIRE MUST BE INSTALLED PRIOR TO DRYWALL CEILING. ALL GRID LUMINAIRES MUST BE SECURED TO STRUCTURE ABOVE. non-emergency optional - bar hangers key sold separately power off power on level attention see additional instructions emergency - integral test switch emergency - remote test switch OVERLAP TRIM WALL WASH ORIENTATION FLUSH TRIM drywall only WALL 1 1 55/3 min 51/4 max 55/3 min 51/4 max 8.0 8.0 GRID 1/" CONDUIT & CLIP (BY OTHERS) X 3 Luminaires must be installed by a qualified electrician (check with local and national codes for proper installation). IS080 REV. G 016 Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 6063 www.focalpointlights.com 1 of 6
GRID continued BAR HANGERS (SOLD SEPARATELY) 3a X 3b 4 multiple luminaires only 5 45 1/4" max above ceiling 6 make electrical connections DRYWALL WOOD STUDS BAR HANGERS (SOLD SEPARATELY) x 3a 3b IS080 REV. G 016 Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 6063 www.focalpointlights.com of 6
METAL STUDS BAR HANGERS (SOLD SEPARATELY) 3a x 3b DRYWALL OVERLAP TRIM - see GRID instructions steps 4-6 on page DRYWALL FLUSH TRIM 5 4 flush with ceiling make electrical connections 6 7 90 8 EMERGENCY - HEIGHT 9 DRYWALL MUD TAPE SEE BATTERY MANUFACTURER INSTRUCTIONS emergency maximum mounting height: 17.00' IS080 REV. G 016 Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 6063 www.focalpointlights.com 3 of 6
EMERGENCY - INTEGRAL TEST SWITCH A ABOVE CEILING ACCESS REQUIRED B SEE BATTERY MANUFACTURER INSTRUCTIONS BATTERY UNIT CONNECTOR INSIDE EMERGENCY - REMOTE TEST SWITCH A DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND A.C. POWER IS SUPPLIED ABOVE CEILING ACCESS REQUIRED B C 6.48" ± 0.5" release test switch from bracket prior to installation (CENTER OF LIGHT MODULE TO CENTER OF HOLE) Ø 0.75" ± 0.15" 11 D E adjust test switch until canopy is flush with ceiling F BATTERY UNIT CONNECTOR INSIDE G SEE BATTERY MANUFACTURER INSTRUCTIONS DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND A.C. POWER IS SUPPLIED IS080 REV. G 016 Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 6063 www.focalpointlights.com 4 of 6
SERVICE note: 3mm hex key required 1 REMOVE TRIM SEE TRIM REMOVAL ON FOCAL POINT INSTRUCTION SHEET IS081 integral test switch requires 1/4" nut driver for removal 3 4 5 KEEP THERMAL PAD FOR REINSTALL 6 11 7 8 REPLACE THERMAL PAD IS080 REV. G 016 Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 6063 www.focalpointlights.com 5 of 6
WIRING DIAGRAM (non-emergency) WHITE (NEUTRAL) (LINE) THERMAL PROTECTOR **OPTION WITH 000Lm MODULES ONLY** NUVENTIX DLM COOLER RED WHITE BLUE (10V) RED (77V) ORANGE GREEN WHITE PURPLE BLUE RED YELLOW PURPLE **OPTIONAL** 0-10V DIMMER EMERGENCY LUMINAIRES WIRED ACCORDING TO BATTERY MANUFACTURER S INSTRUCTIONS. (individually capped at factory for non-dimming applications) Contractor is responsible for adequately reinforcing walls and/or ceilings to support fixture weight. Focal Point, LLC accepts no responsibility for inadequately reinforced walls and/or ceilings. The information contained in this drawing is the sole property of Focal Point, LLC. Any reproduction in part or whole without the written permission of Focal Point, LLC is prohibited. Covered by US Patent: 8,0,641. IS080 REV. G 016 Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 6063 www.focalpointlights.com 6 of 6