S300 Series Dust Monitors



Similar documents
How To Use A Ds340 (Dsp)

DUST EMISSION MONITORING SYSTEM

EuroFID Total Hydrocarbon Analyzer. Precise Determination of Total Hydrocarbons in Air for Corrosive as well as Condensing Gases

Inductive sensor NI10-M18-Y1X-H1141

Online Infrared Flue Gas Analyzer Gasboard 3000

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Contents. Document information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

COMBIMASS. Technical Data COMBIMASS eco-bio +

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Triple Waveband Infra-Red Flame Detection

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

2.12. page Products for Explosion hazardous Environment

Digital inductive conductivity transmitter

Gerry Kaelin, FilterSense, USA, describes the ways in which optimising toward compliance with environmental regulations can reduce baghouse

Bulk Flow Meter LB 442 P R O C E S S C O N T R O L

Duct Humidity Transmitter

Micro Motion 3098 Gas Specific Gravity Meter

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

How To Use A Flowmeter

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

SEISMIC VELOCITY TRANSDUCER T1-40

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Certificate: _01 / 29 April 2014

Labkotec SET. Labkotec separator alarm system protecting our environment. Measure your success

Certificate: / 20 August 2013

Plastic tube flowmeters Series PT/PS

Dew-Point Measurement Solutions

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

ISO-9001:2000 certified. EE300 Series Electromechanical Inventory Level Measuring System. Aplus Finetek Sensor, Inc.

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Environmental Equipment, Inc. IMR 5000 Continuous Flue Gas Monitoring System IMR 5000

HERZ-Thermal Actuators

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

T7560A,B,C Digital Wall Module

Temperature & Humidity SMS Alert Controller

Flow switches Series AD/VH

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

Instruction Manual. T3111 T3111L T3111P T3111Ex

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

Instructions for Safe Use

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Model: DC-A2IO Advanced HVAC Controller

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Adsorption air dryers ADS 1 215

Analytical Instruments Smart Analyzer 90 Type SMA

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

Ground Resistance Clamp On Tester

3500/22M Transient Data Interface

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

3500/62 Process Variable Monitor

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

For Multi-Parameter Meters see mvx

Technical Information RIA14

Material test chamber with mechanical convection

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Adjustment functions for both span and shift have been incorporated

Application Note 12: TrendView Recorders Continuous Emissions Monitoring

Analogue addressable devices

Conductive Level Switch FK 2 Technical Data:

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

WEATHER STATION FOR SOLAR FARM MONITORING

CQM1-SF200/CS1W-SF200

Buckeye Detection Systems Fixed Detection Systems Application Survey

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

Technical Data. Dimensions

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Positioner Versions. Remote feed-back. Local display, Electric / Hydraulic. Remote feed-back Electric / Hydraulic. Embedded Control Positioner

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Smart DeviceNet Remote I/O Terminals

How To Read A Pipe From A Sensor

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Transcription:

S301 DustGuard S303 Trend Monitor S304 Emission Monitor S305 Stack Monitor Intrinsically Safe (ATEX) Dust Monitors Split Architecture (Remote)Models Data Logging Software S300 Series Dust Monitors Dust Monitors with a Difference! Products www.sintrol.com

Sintrol S300 Dust Monitors Automatic Range setup No manual adjustment required Automatic drift compensation Colour of particles will not affect the reading No optical windows to be kept clean Buildup of dust on the probe will not affect monitoring No alignment required Vibration has no effect on the reading S301 Designed as a filter bag leak detection monitor. Equipped with two independent alarm relays which can be used for early warning and failure, or connected to alarm-devices, it is used to detect filter deterioration and blockage or breakage. The alarms can be used for process control (as an ON-OFF system) in flow no flow situations in bulk solids handling and pneumatic transport applications. Very fast response time, a typical charateristic of these monitors, enables early detection and prevention of expensive product loss to the environment. S303 Also has a 4 20 ma analog signal output used for trend monitoring. It is installed downstream of a filter, cyclone, dryer, or similar devices to monitor the filter performance as well particulate emissions. It has two alarm relays which will energise when the amount of particulate in the gas stream exceeds a preset level. It can also be used for process control in certain applications. S301 and S303 are designed for use in any process fitted with bag, ceramic, or cartridge filters or cyclones where indicative (qualitative) monitoring is required. S304 Linear monitor for dust emission monitoring Automatic range setup Automatic drift compensation Can be calibrated to mg/m 3 (dust concentration) Remote configuration Remote data collection via data-logging software PIN code protection S305 Linear monitor for stack-monitoring applications Automatic range setup Automatic drift compensation Can be calibrated to mg / m 3 (dust concentraion) Remote configuation and data collection TÜV Certificate: BImSchV 13, BImSchV 17, BImSchV 27, BImSchV 30 and TA Luft 2002 Self Zero check and self Span check PIN code protection ATEX Models Certified for ATEX Zone 20, 21 or 22 Approved to Category II 1/2 for Gas and Dust IP 65 Enclosure, Custom Designed Certification Type: II 1/2 GD EEx ia IIC, T6, IP65, 85 C Utilising SINTROL s Advanced Dust Detection Technology The ATEX Directive covers health and safety of workers potentially at risk from exposure to explosive environments. This Directive classifies areas into Zone 0, 1, 2 for gas and 20, 21 or 22 for dust and ensures that only ATEX certified systems are installed in the areas. Products are required to be categorised by the level of protection that they offer against the risk of them becoming a potential source of ignition in an explosive atmosphere. The equipment conformity categories are 1, 2 & 3. Split Architecture (Remote ) models S300 Series include the following remote models: S311, S313, S314 and S315. The remote models are used when the sensor has to be installed on a pipe, duct or stack but the control unit up to 200 meters away in control room. In these models, the sensor is connected to an enclosure housing the preamplifier (PA) and the amplified signal is transmitted with a 4-wire shielded cable using one of the recommended cables. Product Range Optional x Available Standard S301 S303 S304 S305 2 Independent alarm relays (user selectable alarm limits, NO or NC) 4 20 ma signal output Remote setup & configuration Self zero check Span check Filter bag leak detection. ON-OFF systems. Pneumatic transport Trend monitoring. Filter performance Filter performance. Particulate emissions Stack monitoring. Can be calibrated to mg / m3 Serial communication ATEX approved model x x x x Remote models

Datalogging and Configuration Software Datalogging and configuration software for alarm logging and emission reporting Hourly, daily or monthly averages can be generated from logged data Read out, configure and send the parameters back to the monitor. Start monitor s autosetup procedure from software Up to 20 simultaneous channels can be seen in user interface, channel number can be multiplied with several sessions of software Online trend view with zoom and pan Analog ma, serial or ethernet connection Remote Display D400 Remote digital display supplied with S300 series monitors (optional) can beused with any of S300 series models. Comparison of S304 / S305 and an Optical Dust Monitor Time Surge caused by hammering Detected by S303/S304 dust monitor Optical method measurement Data is presented from parallel testing of a S304 / S305 dust monitor and an optical monitor both installed downstream of an electrostatic precipitator (ESP) in a cement plant. Peaks in the signal outputs from the instruments correspond to hammering of the ESP which is carried out periodically to remove the particulate matter from the precipitating electrode. Fast response time of the S304 / S305 is one of the excellent characteristics of these dust monitors. Principle of Operation In the S300 series monitors DC component of the signal is mathematically filtered out and stored for use if required. Only the AC component of the signal is used for monitoring solid particles. The signal is obtained by the particles impacting the sensor rod or passing nearby. Both modes of charge transfer, impaction and induction contribute towards the signal acquisition. The monitor is not affected by particle buildup on the probe. Automatic Setup Procedure With no optical windows to be kept clean and no problem of the alignment of the light axis, S304 and S305 proved to be an excellent choice for monitoring of dust in the stack of the cement plant. Tests and Test Results Extensive tests carried out with different types of particulate matter in Finland and Germany showed S304 / S305 s excellent linearity with various dust types. The particulates used included test dusts with known particle size distributions as well as ash from coal fired power plants. The Figure, shows the linearity of these monitors for a typical dust. (Particle size: 1 10 microns). S300 Series dust Monitors utilise a unique method of detecting dust particles. The received signal is analysed in the 16-bit microcontroller of the monitor over a period of time and the average value determined. The monitor then selects the right range itself. No manual range setup is required.

Typical Applications Cement manufacture Chemical processing Metals industry Foundries Pharmaceutical industry Mineral drying Fertilisers Wood processing Food and tobacco Rubber compounding Animal feed processing Power plants Waste incinerators Pulp and paper Typical Trend-Monitoring Application (Dryers) The schematic diagram below shows an application where S300 series dust monitors are installed after a filtration system to monitor the solid flow continuously downstream of the filters and also to detect leakage or filter breakage. age. Back pulsing is carried out one compartment at a time to avoid condensation and clogging. The first compartment is being back pulsed in this picture. Fan is alweays operated for back pulsing. Trend monitoring data shows that there is a correlation between dust concentration and signal output of the S303 Dust Monitor. This dust monitor was operated for several months without maintenance. Foundry S300 dust monitors are installed after the baghouses (or electrostatic precipitators in some cases) to monitor these particulate arrestment systems. The continuous ma signal outputs at points 1 and 2 give information on filter wear and tear. The S304 / S305 installed at point 3 is used to measure the total emission of foundry dust, i.e. for stack-monitoring.

Dust Measurement of Coal-fired Power Plant Flue Gas with S300 Series Dust Monitors Flue gases from pulverized coal fired power plants contain particulate matter that have to be removed to comply with stringent environmental regulations. Electrostatic precipitators (ESP) are used for this purpose. p Continuous monitoring of particulate matter in the flue gas is needed to maintain high efficiency of the ESP and to detect its abnormal operation. S304 and S305 dust monitors are used for this purpose because of their excellent characteristics and easy maintenance. S300 series dust monitor Fluegas desulfurization system Dust Measurement of Cement Kiln s Exhaust gas with S300 Series Dust Monitors The exhaust gases from a cement manufacturing plant contain particulate matter that have to be removed to comply with stringent environmental regulations. Electrostatic precipitators (ESP) are used to reduce the particulate matter to an acceptable level. S304 and S305 dust monitors are used to monitor the ESP as well as the particulate matter downstream of the ESP. Environmental Standards A reliable and accurate dust monitoring system is needed to satisfy the continuous monitoring requirements of the environmental regulatory authorities and to ensure compliance with increasingly stringent standards imposed for particulate emissions to the atmosphere. Sintrol s S304 and S305 dust monitors are proving an ideal solution for stack-monitoring requirements of a variety of applications including coal-fired power plants and incinerators. TÜV certification includes: 13 BImSchV, 17 BImSchV, 27 BImSchV, 30 BImSchV and TA Luft 2002.

Technical Specification Measurement objects Solid particles in a gas flow Particle size 0.3 μm or larger Measurement range approx. 0.1 mg / m 3 to 1 kg / m 3 Dimensions Process Conditions Temperature Pressure Gas velocity Humidity Input surge voltage Measurement principle Analog damping time constant 300 C (standard), 700 C (high temperature) Max. 2 bar Min. 4 m/s 95 % RH or less (non-condensing) Max. 100 V electrostatic detection and electric induction 10 to 180 seconds, (10-300 s optional) Enclosure Cover Sensor Front panel (cover off) Output signals Isolated 4-20 ma Relay 5 A, 24 V AC / DC Serial communication depend on model all models depend on model Ambient conditions Temperature Humidity Vibration -20 to + 45 C and 60 C for 24 VDC 95% RH (non-condensing) 5 m / s 2 or less Materials Sensor rod Insulation of sensor Enclosure / casing Power Supply Power consumption DC model AC model Wiring connections Power supply Output signals Weight Range set up Normal measuring range Extended measuring range Relay alarm options Alarm level Software alarm option Offset trim Stainless steel (AISI316) PEEK (HT: klinger) Aluminium alloy 100 or 115 or 230 VAC, 24 VDC Max. 3W Max. 8W DIN PG11 cable gland DIN PG11 cable gland 2.3 kg Automatic, based on average measured dust flow during setup procedure User selectable (optional) Automatic, set at factory (based on average measured dust flow) or user selectable fixed ranges Configurable via data logging software Automatic drift compensation Ordering codes for S300 monitors Temperature ( C) 3 300 7 700 Pressure L < 2 bar H > 2 bar Voltage 1 230 VAC 2 115 VAC 3 24 VDC Air purge N Y X X X X æ X X X without air purge with air purge Probe length (mm) 1 250 5 500 7 750 9 1000 Options R with remote display Process connection S Standard Q Quick clamp F Flange e.g. S304 3L1Y5RS for 300 C, < 2 bar, 230 VAC, with air purge, 500 mm probe, remote display, standard process connection. See the chart at page 2 for product type details. Sintrol Inc. www.sintrol.com info@sintrol.com Sintrol Oy 2012 All Rights Reserved