STATE BANK OF INDIA.



Similar documents
BOQ for Plumbing, Sanitary Works

PLUMBING MAINTENANCE WORK FOR TOILETS IN HEAD OFFICE, SUPPLYCO ESTIMATE

SUMMARY (PLUMBING WORKS)

Toilet Plumbing. Here is a selection of different types of W.Cs and urinals. Can you match the pictures to the names below?

Tender schedule. Rate in

Revised Specifications & Scale of Amenities for General Pool Residential Accommodation (Type I to VI) Revised Amenities.doc

Project : CONSTRUCTION OF BUILDING(including electrical and plumbing works) FOR NATIONAL CENTRE FOR SUSTAINABLE COASTAL MANAGEMENT,CHENNAI

LONDON BOROUGH OF HACKNEY BUILDING SERVICES ENGINEER REPORT GAS HOUSE, SPRINGFIELD PARK, HACKNEY

BILL OF QUANTITY FOR THE WORK OF "REPAIRING OF CIVIL & PLUMBING WORKS INSIDE AND OUTSIDE OF THE WORKSHOP"

CUBICLE SYSTEMS LTD. CI/SfB 74 X IPS. Pre-plumbed Wall Duct Access Panel System

BUDGETARY COST ESTIMATE OF INTERIOR WORK OF LOWER PAREL BRANCH FOR CENTRAL BANK OF INDIA

Sports Buildings: budget costs for the Flood Relief Fund

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

SPECIFICATIONS FOR VASWANI BRENTWOOD PROJECT. RCC Framed Structure confirming with zone II seismic detailing. Reinforced Cement Concrete

CONSTRUCTION SUMMARY OF THE PEREIRA HOUSE AT MADOL, VERNA GOA.

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

SECTION V : TECHNICAL SPECIFICATIONS. B) Plumbing, Water Supply & Sprinkler system

Close Coupled & Back To Wall WC Saintaryware. Fitting Instructions

WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST

ESTIMATE (CIVIL) BASED ON DSR 2013 NAME OF THE WORK :- A.R.M. CIVIL WORK OF E.S.I.C. SRO BUILDING AND RESIDENTIAL QUARTERS FOR THE YEAR

Saferand easierinstallation

SECTION REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

Old people and nursing homes. Old people and nursing homes, rehab/medical. SPECIAL SOLUTIONS. Security and comfort for every stage of life.

REGISTRATION EXAMINATION, NOVEMBER 2013 CERTIFYING PLUMBER ANSWER SCHEDULE

WATER SERVICE 2

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

LS 2540 SEWER LATERALS AND INSPECTION TEES

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Qualification Guide. BPEC 601/2514/7 - Level 1 Diploma in Plumbing Foundation. BPEC 600/9432/1 - Level 2 Diploma in Plumbing Foundation

WARDEN 4 ELECTRONIC WATER MANAGEMENT SYSTEM FEATURING:

NATIONAL INSTITUTE OF BIOLOGICALS

BIS WC Element / Lyft Alpro

Chapter 7 Plumbing Connections

GENERAL SPECIFICATION FOR CIVIL ENGINEERING WORKS SECTION 13 WORK FOR ELECTRICAL AND MECHANICAL INSTALLATIONS

EXHIBIT "A. Technical Specifications for Water and Sewer Service Lines

G. M. ENCLAVE PVT. LTD. Corporate office: AB-9, Salt Lake, Sec-I, Kolkata Phone: , Fax:

L_All_Vocatinal_Ed_Construction. Sector: Construction. Sr. No Specialisation Page No 1 Construction and Building Technology 02.

When Should Examination Preparation Begin?

Introduction. Contents. General. Materials and workmanship. Diagrams. Other regulations. References

SECTION STORM DRAINAGE SYSTEM

ISSUE 08/08. KEEP INFORMED Look for other Good Idea Leaflets that could help you with your current project.

plumbing products guide

CAVITY DRAIN MEMBRANE SYSTEMS: SUMPS AND PUMPS GUIDANCE NOTES

PART-II (COMMERCIAL / PRICE BID) DESIGN, SUPPLY AND INSTALLATION OF CUSTOMIZED STEEL LAB FURNITURE.AT N.C.C.S., PUNE

PUBLIC RESTROOMS, DESIGN INTENT

:2009 HELLENIC CHNICAL SPECIFICATION ежглеяис тгс йубеямгсеыс (теувос еутеяо) Sanitary ware, common ICS: 93.

GUIDELINES FOR OPERATORS OF MOBILE FOOD BUSINESSES: DESIGN, CONSTRUCTION

SECTION PUBLIC STORM UTILITY DRAINAGE PIPING

Borges Construction Company A limited liability Corporation Page1 of 1

2010 Residential Water Heater Replacement Check List

CONTRACT PRICE ADJUSTMENT PROVISIONS (CPAP)

Most suitable piping material

PLUMBING CARE AND REPAIR

What to Expect From the Examination. How to Study the Plumbing Codes

WC flushing cistern single or dual flush to fill in 2 minutes WC trough cistern 0.15 per WC Wash basin tap size 1 2

Brian Coppock, Regional Compliance Officer. Office of Statewide Health Planning and Development Facilities Development Division

How To Use An Akua Magnetic Lime Scale Preventing Device

31. ECO-INFO -- SEPTIC SAFE PROTECT YOUR HEALTH AND ENVIRONMENT YOUR SEPTIC PUMP-OUT SYSTEM with SELF ASSESSMENT TROUBLE SHOOTING GUIDE

SECTION STORM DRAIN SYSTEM

B. Shop Drawings: Diagram power, signal, and control wiring.

Planning Guide for Accessible Bathrooms AS including Amdt , ambulant and complimentary items. Sydney Melbourne Brisbane Auckland

EFFECTIVE FEBRUARY note: drainage permit required to call for a dampproof inspection

How To Run A Test Lab In Rourkela

Montgomery County Health Department Mobile Food Guidelines. Definitions

TECHNICAL SPECIFICATIONS & TERMS AND CONDITIONS FOR SOLAR WATER HEATER (FPC/ETC)

INSTALLATION INSTRUCTIONS

Sealant. 30" Model No D: 17-7/8" TO 18-3/8" (454 to 466mm) W: 29-3/4" TO 30-1/4" (756 to 768mm) Under Countertop Installation

Issue of the Guidelines on Prevention of Water Seepage in New Buildings

Installation Guide. Bath and Wall Surrounds SERIES B

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta

Turnkey Projects, Conversions, Restorations & Property Management. Marsalforn - Gozo APARTMENT FINISHING EXCLUSIVE PACKAGE

APPLICATION FOR FITOUT OR PLAN ASSESSMENT UNDER THE FOOD ACT 2001

Stainless Steel Single and Dual Circulation Kits

INTERCEPTORS TABLE OF CONTENTS S-WD-INTER

SECTION POLYVINYL CHLORIDE (PVC) PIPE

SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION

FLUSHING CISTERNS. product catalogue

STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2

Carriers, Fixtures & Piping

Syphonic Roof Drainage

THE VOID LETTABLE STANDARD

Mechanical Services Standard Specification Above Ground Soil, Waste and Ventilation Pipes

A SMALL-SCALE ARSENIC AND IRON REMOVAL PLANT

CHAPTER 11 STORM DRAINAGE

Prepare a drainage system layout and specification notes for a low- rise building.

Plumbing Code in Commercial Kitchens. NH BOA May 9, 2012

A. Accessible Fixture: Emergency plumbing fixture that can be approached, entered, and used by people with disabilities.

SECTION STORM DRAINAGE STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

BUILDING TRADES II PLUMBING: ROUGH-IN AND FINAL TEACHER S GUIDE

BOQ SPECIFICATIONS. The Blind system consist of a coated aluminium tube of 38 mm diameter with provision of fabric clamping.

AT FIRST SIGHT Important informations

PLUMBING PERMIT APPLICATION (PLUMBING PERMIT TO BE SECURED 24 HOURS BEFORE WORK STARTS)

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

Welcome: What is U Drain? Drain Materials. Flow

Transcription:

Page 1 of 5 B SANITARY, PLUMBING & DRAINAGE STATE BANK OF INDIA. PROPOSED RURAL SELF EMPLOYMENT TRAINING INSTITUTE AT RAIGARH IN C.G. DIRECTOR'S BUNGALOW SCHEDULE OF ITEMS-PLUMBING AND SANITARY WORK 1 Providing and fixing in position Chlorinated Polyvinyle Choride (CPVC) pipes concealed in the brick masonary walls by cutting chases using mechanical cutter, providing nails/clamps to hold the pipes in position and making the surface good in line and level. The pipes should have thermal stability for hot & cold water supply including providing required CPVC brass threaded fitings and specials such as 'Tees, Bends, angles, Elbows, reducers, unions etc and fixing the pipes with metal clamps at 1.0 m c/c, including joining the pipes as per manufacturers specifications using approved quality CPVC Solvent and testing the joints complete as per directed Wherever necessary hot water pipes to be suitably insulated to prevent heat transfer to wall tiles etc. a) 15 mm nominal outer diameter pipe Rmt 25.00 2 Providing and fixing in position Chlorinated Polyvinyl Choride (CPVC) pipes externally having thermal stability for hot & cold water supply including all CPVC brass threaded fitings such as 'tees, bends, angles, reducers, unions etc and fixing the pipes on metal clamps away from the wall at 1.00 m c/c including joining the pipes as per manufacturers specification with one step CPVC Solvent /solvent cement and testing the joints complete as per directed, a) 25 mm nominal outer diameter pipe Rmt 20.00

Page 2 of 5 b) 32 mm nominal outer diameter pipe Rmt 20.00 c) 50 mm nominal outer diameter pipe Rmt 15.00 3 Providing and fixing in position CP Brass Bib Cock of approved quality and make, including all fittings and fixturers 4 Providing and fixing in position CP Brass Stop Cock of approved make and quality including all fittings and fixturers 5 Providing and fixing ISI marked gun metal valve with C.I. wheel of approved quality (screwed end) and make Nos 10.00 a) 50mm nominal bore b) 32 mm nominal bore 6 Providing and fixing ISI marked non return valve of approved quality 7 Providing and fixing in position long neck Bib Cock for kitchen etc including all fittings and fixturers 8 Providing and fixing in position Wash Hand Basin, counter sunk of ivory colour of approx size 440 mm x 550mm including providing CP Brass Pillar Cock, Bottle Trap, Stop Cock, PVC Connection, Base Coupling etc. of approved quality and make. Rate to include suitable MS bracket including 40mm dia connection GI pipe upto nahani trap concealed in wall 9 Providing and fixing in position stainless steel kitchen sink of approved make of approx overall size 535 x 460 x 190 mm deep fixed to Kitchen platform, including providing CP brass, base coupling, bottle trap etc. of approved make and making suitable connection to nahani trap complete with 40mm dia GI pipe 'b class'

Page 3 of 5 10 Providing and fixing in position European WC pan of approved make and size including providing and fixing PVC Flushing Cistern of 12 liters capacity, PVC toilet seatcover including necessary fitings and fixturers viz. Flush pipe, CP brass stop cock, PVC connection etc 11 Providing and fixing in position Orissa pattern 'Indian' WC pan with 12 liters Low Level PVC flushing cistern etc including all necessary CP fittings, stop cock, PVC connections etc. 12 Providing and fixing in position PVC heavy duty 'nahani trap' including all connections to waste water line 13 Providing and fixing in position CP brass soap holder of approved make and quality including all fittings and fixturers 14 Providing and fixing in posiion CP brass hooks on doors etc including all fittings and fixturers 15 Proviidng and fixing in position CP Brass Jet spray with flexible pipe and necessary two way fitting of approved make including necessary fittings and fixturers 16 Providing and fixing in position heavy duty PVC down take pipes (4Kg pressue) of Prince, Supreme, Katsa or equivalant approved make including all acessories such as 'Y', 'angle junction', 'connectors', 'inspection joints' etc joining together water tight using approved adhessive and clamping it on wall with 'D' clamps Nos 3.00 a 100 mm dia Rmt 50.00 b 65 mm dia Rmt 7.00

Page 4 of 5 17 Providing and constructing Inspection Chambers of approx size 450 x 900mm in one brick thick walls, including providing plaster 1:4 cement sand mix in single coat about 12mm and with heavy duty PVC cover including the frame as per sample approved. The rate should include necessary earthwork in excavation, disposal of surplus material as directed, laying P.C.C. 1:3:6, 100mm thic levelling course, making neat cement finish smooth benching, hunches, channels etc. in CC 1:2:4 complete for smooth flow as required. Rate to include for making connections to stone ware/pvc pipes of minimum 150 mm dia in the brick wall 18 Providing making Gully Trap of approx size 450 x 450 in one brick thick, and finishing it with 12mm thk 1:4 cement sand mix plaster, including providing P.C.C. benching and providing stone ware pipe connections, with approved quality CI/PVC cover with frame 19 Providing and laying heavy quality (Minimum 6 Kg pressure) PVC pipes for sewerage disposal system including necessary excavation, laying 100mm thick PCC 1:3:6 levelling base course with all fittings and specials testing of joints and concealing the Pipe in PCC 1:2:4 all around with minimum 100 mm thick concrete complete as directed at site. Nos 2.00 (a) 200 mm dia. Rmt 20.00 (b) 150 mm dia. Rmt 5.00 20 Providing and fixing PVC overhead tank required capacity as under including construction of 150mm high platform with concrete blocks/bricks/cc (finishing complete) and all connections (inlet & outlet) with necessary fittings and making them water tight

Page 5 of 5 PVC (1500 litres) Director's Bungalow Total of plumbing and sanitation (B) SIGNATURE OF THE CONTRACTOR NAME ADDRESS