Calculating System Flow Requirements



Similar documents
Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Solar Thermal TECHNOLOGY. Eric Buchanan Renewable Energy Scientist West Central Research and Outreach Center Wcroc.cfans.umn.edu

COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.

Chilled Water HVAC Systems

MAC-120HE-01 Air-Cooled Chiller

DOWFROST GEO 20: Propylene Glycol-Based Heat Transfer Fluid for Geothermal Heat Pump Systems

OPTIMIZING CONDENSER WATER FLOW RATES. W. A. Liegois, P.E. Stanley Consultants, Inc. Muscatine, Iowa

HOT & COLD. Basic Thermodynamics and Large Building Heating and Cooling

Dispelling the Myths of Heat Transfer Fluids. Kevin Connor The Dow Chemical Company

See any red flags? Let s take a look at the problems that occurred on the job and how to avoid making the same mistakes.

Defining Quality. Building Comfort. Heating and Cooling Coils

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

Cooling Systems 2/18/2014. Cooling Water Systems. Jim Lukanich, CWT ChemCal, Inc. Grapevine, TX

CONVERTING A CLOSED-LOOP WATER SYSTEM TO A GLYCOL SYSTEM

High Altitude HVAC. Silvertip Integrated Engineering Consultants

Chapter 3.4: HVAC & Refrigeration System

Pump Formulas Imperial and SI Units

HVAC Efficiency Definitions

Optimization of Water - Cooled Chiller Cooling Tower Combinations

Benefits of Water-Cooled Systems vs. Air-Cooled Systems for Air-Conditioning Applications

Design of A Waste Energy Recovery System For the Pettit National Ice Center

COMMERCIAL HVAC EQUIPMENT. Condensers and Cooling Towers

Glossary of HVAC Terms

Ground Source Heat Pumps The Fundamentals. Southington, Connecticut John F. Sima III P.E.

HVAC Simplified Approach Option

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

CHILLER PLANT CONTROL MULTIPLE CHILLER CONTROLS

How much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page.

How To Use A Water Source Heat Pump

FAN COIL UNIT SOFTWARE User Manual

Effects of Ultra-High Turndown in Hydronic Boilers By Sean Lobdell and Brian Huibregtse January 2014

ICE THERMAL STORAGE IN AIR CONDITIONING APPLICATION FUNDAMENTALS

Geothermal Heat Pump Systems

GLOBACON 05 HVAC Systems for Cogen

Creating Efficient HVAC Systems

SAN DIEGO COMMUNITY COLLEGE DISTRICT CITY COLLEGE ASSOCIATE DEGREE COURSE OUTLINE

Building Energy Systems. - HVAC: Heating, Distribution -

BULLETIN NO. TEH-908. Bell & Gossett R T. Hydronic System Design with the Bell & Gossett System Syzer / ON GPM FLOW

HVAC Systems: Overview

Refrigeration Basics 101. By: Eric Nelson

Glossary of Heating, Ventilation and Air Conditioning Terms

9. ENERGY PERFORMANCE ASSESSMENT OF HVAC SYSTEMS

HVAC and REFRIGERATION

Heat Recovery In Retail Refrigeration

Rusty Walker, Corporate Trainer Hill PHOENIX

Florida Power & Light Company. Business Heating Ventilation & Air Conditioning ( HVAC ) Program Standards. Effective: November 9, 2015

This presentation is posted for public use. ACEEE does not endorse any product or service.

HVACPowDen.xls An Easy-to-Use Tool for Recognizing Energy Efficient Buildings and HVAC Systems

CHILLED WATER PLANT PUMPING SCHEMES. James J. Nonnenmann, PE Stanley Consultants, Inc. Muscatine, Iowa

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

Condensing Boiler Efficiency

TODAY S PARADIGM FOR AIR TO AIR HEAT RECOVERY

It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.

Advanced Heat Reclaim Systems. Harrison Horning, PE, CEM Delhaize America - Hannaford

HOT WATER SYSTEMS CONTENTS

EVERYTHING YOU WANTED TO KNOW ABOUT GLYCOL A Brewery Glycol System Guide. Updated

for Plans Examiners and Building Inspectors

Secondary Heat Transfer Systems and the Application of a New Hydrofluoroether

Mechanical-Electrical Technology MECHANICAL-ELECTRICAL TECHNOLOGY Sacramento City College Catalog

PLBG/GAS SAFETY Information Bulletin

Chilled Water System Commissioning: Variable Primary Flow. John D. Villani, P.E. Associate Grumman/Butkus Associates

Closed-Loop Ground-Coupled Heat Pump Systems

Benefits. Air-Cooled Systems

Heating, Ventilation & Air Conditioning Equipment

HVAC Basic Science - System Capacity

Steamfitters & Plumbers Local Union No. 464 JATC. HVAC/Service Curriculum. Work Process: Mechanical & Electrical Principles

Applying Pressure Independent Control Valves in H.V.A.C. Systems. A Presentation to: Orange Empire ASHRAE Santa Ana Nov. 17, 2009

COMMISSIONING OF HVAC SYSTEMS

UA-NJ Air Conditioning & Refrigeration Division Training Curriculum

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION

Contents and Nomenclature

HEAT RECOVERY FROM CHILLED WATER SYSTEMS. Applications for Heat Reclaim Chillers

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

Selection Tips For Air-Conditioning Cooling Systems

STULZ Water-Side Economizer Solutions

Guidelines for energy efficient heating, ventilation and air conditioning (HVAC) systems

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014

Typical Cooling Load Profile

Boiler System Efficiency

How does solar air conditioning work?

Solar Absorption Cooling / Heating System for the Intelligent Workplace

Impact of Control System Technologies on Industrial Energy Savings

How To Design A Building In New Delhi

Application Guide AG Geothermal Heat Pump. Design Manual McQuay International

ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE

State of the Art Energy Efficient Data Centre Air Conditioning

GREEN FIELD DATA CENTER DESIGN WATER COOLING FOR MAXIMUM EFFICIENCY. Shlomo Novotny, Vice President and Chief Technology Officer, Vette Corp.

Ceiling Mount Air Handler Manual

Pharmaceutical central utility plants

Design of a Heat Pump Assisted Solar Thermal System

How To Understand Evaporator

HVAC: Cool Thermal Storage

Case Study: Innovative Energy Efficiency Approaches in NOAA s Environmental Security Computing Center in Fairmont, West Virginia

Air-sourced 90 Hot Water Supplying Heat Pump "HEM-90A"

A Glossary of HVAC Terms:

PHCC Educational Foundation Contractor Library Engineering Continuing Education

Basic Nameplate Information

جامعة البلقاء التطبيقية

Guidelines for Selecting and Maintaining Glycol Based Heat Transfer Fluids

Transcription:

Calculating System Flow Requirements To select a pump, we need to know the flow rate (the amount of fluid to be pumped) and the system resistance or head. In the U.S., flow rates are given in gallons per minute, or GPM. The GPM is a function of the heat loss (or gain) of the building space served by the pump or the process load that is to be met by the pumped systems. It is ALSO a function of the design temperature change of the fluid as it travels through the hydronic system. The temperature change is commonly called the Delta T, or T, where the triangle is the Greek symbol for the word Delta. Heat Load Determining the heat load of a building, a zone, or a process is beyond the scope of this paper. Once a time-consuming manual procedure, computer software now simplifies building load calculations considerably. You can download trial versions of some software from the Internet. Loads are expressed in British Thermal Units Per Hour, or BTUH. Other units of measure are: 1. MBH = 1,000 BTUH 2. Tons = 12,000 BTUH (used for cooling applications) 3. Cooling tower tons = 15,000 BTUH* *This term is used only when the tower serves an electric chiller or other refrigeration system. In this application, the cooling tower must handle a building load of 12,000 BTUH per ton plus the compressor heat of about 3,000 BTUH/ton. 1 This is conservative in light of today s chiller efficiencies, which often consume less than 3,000 BTUH/ton. Design T (Design Temperature Drop) The system designer determines what T he/she will use in the design. Normal T s for comfort systems are: 1

Heating Systems Cooling Systems Cooling Towers 20, 30, or 40 F 8, 10 or 12 F 10 Degrees Note that these figures are only typical and are common in the HVAC industry. For specific HVAC applications and many process applications, the chosen delta T might be outside these ranges. Assuming that the chosen fluid will be water, once the T is chosen, the GPM of the pump can be determined by the following formula: Formula 1: GPM = BTUH / 500 X T Note that as the chosen T goes up, the GPM goes down. This results in smaller pumps and smaller piping. However, larger T s tend to result in larger terminal equipment in the form of more rows of coil, more fan horse power, longer lengths of fin tube, etc. Note that the 500 factor in Formula 1 applies only to water. This is derived from the formula BTUH = #/HR X BTU/# X T X S.H. where T is given deg-f and S.H. is Specific Heat in BTU/#-Deg F. Note that #/HR of water = GPM X 8.33 #/GAL X 60 MIN/HR = GPM X 500; The S.H. for water = 1.0 at normal HVAC temperatures. Combining these equations and doing the appropriate algebraic substitutions yields Formula 1. For hydronic systems, we often use glycol mixtures to guard against freezing piping and coils that may be exposed to outside air. 2 These mixtures have different densities (#/GAL) and different specific heats (S.H) than water. So for various glycol mixtures, use the factors from Table 1 instead of 500. For other fluids, the more general formula applies: Formula 2: GPM = BTUH /(500 X S.G. X S.H. X T) where S.G. is the fluid s specific gravity. 1 Single stage steam absorption chillers require about 3.6 GPM/Ton and have a heat rejection of around 30,000 BTUH/ton. Two stage absorption chillers require about 3.6-4.0 GPM/ton and have a heat rejection of around 22,000 BTUH/ton. 2 Freeze and burst temperatures for various concentrations of ethylene and propylene glycol are listed in Appendix I at the end of this chapter. 2

TABLE 1 Load Factors for Propylene Glycol Volume % Temp. deg. F 10% 20% 30% 40% 50% 20 N/A 481.7 469.1 453.3 433.5 40 491.0 482.8 471.0 455.6 436.7 60 491.5 484.0 473.1 458.1 439.7 80 491.6 485.1 474.4 460.3 442.4 100 492.0 485.6 475.4 462.2 445.2 120 491.6 486.0 476.5 463.7 447.1 140 490.8 485.5 476.8 464.4 448.8 160 489.7 485.1 476.7 465.2 450.0 180 487.7 484.4 476.8 465.7 451.4 200 486.0 483.3 476.0 465.7 451.8 Load Factors for Ethylene Glycol Volume % Temp. deg. -F 10% 20% 30% 40% 50% 20 N/A 464.4 447.4 428.7 407.4 40 479.5 466.3 450.4 432.2 411.4 60 480.7 468.4 453.0 435.4 415.7 80 481.5 469.7 454.8 438.2 419.2 100 482.1 470.8 456.8 440.8 422.9 120 481.8 466.4 458.6 443.1 425.8 140 481.7 471.8 460.1 445.2 428.7 160 481.3 472.5 460.6 447.3 431.1 180 480.1 472.2 461.4 448.7 433.6 200 479.0 471.6 461.9 449.7 435.2 Once the flow rate in GPM is determined, the next step in selecting the pump is to determine the head requirement. A discussion on this topic can be found as a separate topic within the Technical Data section of this website. 3

Appendix 1---Freeze and Burst Temperatures for Glycol Solutions Note: Dowfrost products are propylene glycol based. Note: Dowtherm products are ethylene glycol based. 4

Note: Dowfrost and Dowtherm are registered trademarks of the Dow Chemical Company. The information above is from Dow s 1996 Engineering and Operating guides for their Downtherm and Dowfrost products and is included here for illustration. 5