Application Note # LCMS-92 Interlaboratory Tests Demonstrate the Robustness and Transferability of the Toxtyper Workflow



Similar documents
Application Note # LCMS-62 Walk-Up Ion Trap Mass Spectrometer System in a Multi-User Environment Using Compass OpenAccess Software

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

amazon SL Innovation with Integrity Setting New Standards in Performance, Simplicity and Value Ion Trap MS

Application Note # LCMS-81 Introducing New Proteomics Acquisiton Strategies with the compact Towards the Universal Proteomics Acquisition Method

Bruker ToxScreener TM. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

Making the Leap to LC/MS/MS: Enhancing and Accelerating Clinical Research and Forensic Toxicology Applications

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

Overview. Introduction. AB SCIEX MPX -2 High Throughput TripleTOF 4600 LC/MS/MS System

Ultra Fast UHPLC-LCMSMS Method Development in Clinical Drug Monitoring

Making the Leap to LC/MS/MS: Enhancing and Accelerating Clinical Research and Forensic Toxicology Applications

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

ProteinScape. Innovation with Integrity. Proteomics Data Analysis & Management. Mass Spectrometry

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

SCREENING FOR DRUGS IN SERUM AND URINE BY LC/ESI/CID-MS AND MS/MS WITH LIBRARY SEARCHING *

Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method

Application Note # LCMS-66 Straightforward N-glycopeptide analysis combining fast ion trap data acquisition with new ProteinScape functionalities

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Cliquid Drug Screen & Quant Software for Routine Forensic Toxicology. great interest in forensic, toxicological and clinical research laboratories.

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

How To Test For Contamination In Large Volume Water

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

Accurate Mass Screening Workflows for the Analysis of Novel Psychoactive Substances

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

Simultaneous Qualitative and Quantitative Data Acquisition for Research of Diabetes Drugs

Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

A Navigation through the Tracefinder Software Structure and Workflow Options. Frans Schoutsen Pesticide Symposium Prague 27 April 2015

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

Simultaneous Metabolite Identification and Quantitation with UV Data Integration Using LightSight Software Version 2.2

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

A Generic LC-MS Method for the Analysis of Multiple of Drug of Abuse Classes with the Thermo Scientific Exactive TM System

In-Depth Qualitative Analysis of Complex Proteomic Samples Using High Quality MS/MS at Fast Acquisition Rates

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

LC-MS/MS for Chromatographers

SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC

MultiQuant Software Version 3.0 for Accurate Quantification of Clinical Research and Forensic Samples

Application Note # MS-14 Fast On-site Identification of Drugs with the mobile GC/MS system E²M

Application of Structure-Based LC/MS Database Management for Forensic Analysis

Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance

New drugs of abuse? A case study on Phenazepam & Methoxetamine

MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification

Pesticide residue analysis: New Trends. Michal Godula, Ph.D. EU Marketing Manager Food Safety & Environmental Thermo Fisher Scientific

Quick and Sensitive Analysis of Multiclass Veterinary Drug Residues in Meat, Plasma, and Milk on a Q Exactive Focus LC-MS System

Pesticide Analysis by Mass Spectrometry

S olid Ph ase Extraction (SP E) Method:

Overview. Purpose. Methods. Results

Metabolomic Profiling of Accurate Mass LC-MS/MS Data to Identify Unexpected Environmental Pollutants

Simultaneous qualitative and quantitative analysis using the Agilent 6540 Accurate-Mass Q-TOF

Advantages of Polar, Reversed- Phase HPLC Columns for the Analysis of Drug Metabolites

Increasing the Multiplexing of High Resolution Targeted Peptide Quantification Assays

Agilent 6000 Series LC/MS Solutions CONFIDENCE IN QUANTITATIVE AND QUALITATIVE ANALYSIS

Technical Procedure for the Solid Phase Extraction of Acidic, Neutral and Basic Drugs for GC-MS Analysis

Increasing Quality While Maintaining Efficiency in Drug Chemistry with DART-TOF MS Screening

What Do We Learn about Hepatotoxicity Using Coumarin-Treated Rat Model?

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

SCREENING FOR THE PRESENCE OF PARA-METHYLTHIOAMPHETAMINE IN URINE BY SOME COMMERCIAL IMMUNOASSAYS AND CONFIRMATION BY GC/MS

Rapid Screening Method for Illicit Drugs, Using an Advanced Solid Core UHPLC Column and UHPLC System with MS/MS Detection

Method Development of LC-MS/MS Analysis of Aminoglycoside Drugs: Challenges and Solutions

Effects of Intelligent Data Acquisition and Fast Laser Speed on Analysis of Complex Protein Digests

aurora ICP-MS Innovation with Integrity The Science of Sensitivity ICP-MS

A Streamlined Workflow for Untargeted Metabolomics

Comprehensive LC/MS Analysis of Illicit and Pain Management Drugs, Including Their Metabolites, in Urine

for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns

HRMS in Clinical Research: from Targeted Quantification to Metabolomics

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

The Scheduled MRM Algorithm Enables Intelligent Use of Retention Time During Multiple Reaction Monitoring

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK

Improving the Metabolite Identification Process with Efficiency and Speed: LightSight Software for Metabolite Identification

API 3200 LC/MS/MS SYSTEM. Performance, productivity and value combined

AppNote 1/2014. Automated Hydrolysis, DPX Extraction and LC/MS/MS Analysis of Pain Management Drugs from Urine KEYWORDS ABSTRACT

AB SCIEX TOF/TOF 4800 PLUS SYSTEM. Cost effective flexibility for your core needs

Discovery of Pesticide Protomers Using Routine Ion Mobility Screening

AppNote 9/2013. Automated Derivatization, SPE Cleanup and LC/MS/MS Determination of Glyphosate and Other Polar Pesticides KEYWORDS ABSTRACT

CLEAN-UP PROCESS FOR MASS SPECTRAL STUDY OF AMPHETAMINES IN PUTREFIED BODY MATERIALS

Instrumentation. Sample pretreatment

Therapeutic Drug Monitoring of Antiretroviral Drugs with HPLC-MS

WATERS QUANTITATIVE ANALYSIS solutions

Metabolomics Software Tools. Xiuxia Du, Paul Benton, Stephen Barnes

AxION edoor. Web-Based, Open-Access Mass Spectrometry Software

Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control

AppNote 1/2012. Rapid Cleanup and Comprehensive Screening of Pain Management Drugs in Urine using Automated Disposable Pipette Extraction and LC-MS/MS

Guide to achieving reliable quantitative LC-MS measurements

Advantages of the LTQ Orbitrap for Protein Identification in Complex Digests

The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen.

A New QuEChERS Dispersive SPE Material and Method for Analysis of Veterinary Drug Residue by LC-MS-MS

NUVISAN Pharma Services

Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

AppNote 7/2009. Analysis of Drugs of Abuse using Automated Disposable Pipette Extraction and LC/MS/MS KEYWORDS ABSTRACT

Transcription:

Application Note # LCMS-92 Interlaboratory Tests Demonstrate the Robustness and Transferability of the Toxtyper Workflow Abstract There is high demand in clinical research and forensic toxicology for comprehensive, specific and transferable techniques that overcome the well-known limitations of current GC-MS, LC-UV/DAD and immunoassay solutions. Liquid chromatography-tandem mass spectrometry (LC-MS) combined with library searching is an emerging screening solution for toxicology research. Here we describe a robust and automated research based screening solution for the detection and identification of drugs and drugs of abuse in biological specimens. The workflow was tested with regard to method- and resulttransferability from lab to lab. Authors Jürgen Kempf, Laura Huppertz, Susanne Vogt Institut für Rechtsmedizin, Universitätsklinikum Freiburg, Germany Markus Meyer, Sebastian Götz, Birgit Schneider Bruker Daltonik GmbH, Bremen, Germany Keywords Instrumentation and Software Library Search amazon speed Toxicology Screening Research Compass OpenAccess 1.4 Drug Screening Research DA 4.1 Drugs of Abuse Research Ion Trap

Introduction LC-MS/MS is an emerging identification solution for clinical research and forensic toxicology. This method is far more specific than immunoassays and provides more information and higher identification rates than LC-UV/DAD detection (Application Note LCMS-72). Compared to GC-MS, LC-MS promises to cover a more comprehensive range of analytes. Due to the availability of large spectral libraries (see Ref. 1) and a high degree of transferability of results from lab to lab, GC-MS is currently regarded as the gold standard in toxicology research. However, the disadvantages of GC-MS such as the need for derivatization and its incompatibility with thermolabile and polar substances mean that LC-MS is being increasingly used. A central feature of the ion trap LC-MS n solution described here is the unique, patented SmartFrag technology, which provides transferability and reproducibility of results from instrument to instrument and from lab to lab. Using SmartFrag provides the highest possible transferability by virtually eliminating variation and tuning from the MS/MS process. This approach identifies substances by retention time and MS 2 /MS 3 spectra combined with a library search, and represents a robust and automated solution for the detection and identification of common drugs, drugs of abuse, and metabolites. A fast LC-gradient for separation, the auto-ms n capability of the amazon speed ion trap for detection of analytes, and a fully automated script for fast and user-friendly data analysis and reporting provide results in the shortest time possible. To demonstrate the transferability of the Toxtyper workflow and to compare the overall performance of different LC-MS ion trap systems, three spiked serum samples and one blank serum sample were sent to five different labs and analyzed using seven different LC-MS systems. Experimental Sample preparation Three mixtures of toxicologically relevant substances were spiked into blank human serum at different concentrations. Additionally, a blank human serum sample was extracted. Sample preparation was carried out using the following liquid-liquid extraction (LLE) protocol. Serum (1 ml) was spiked with 5 ng of D5-diazepam as an internal standard and then mixed with.5 ml borate buffer (ph 9) and 1.5 ml 1-chlorobutane. After a 3 min mixing step, the solution was centrifuged at 4 g for 5 min. The organic phase was separated, aliquoted, and evaporated at 4 C with N 2. These aliquots were forwarded to the 5 participating labs, where the residues were redissolved in 25 µl solvent A/B (5:5; v/v; see Table 1). LC-MS n conditions Two microliters of the redissolved samples was separated on an Ultimate RSLC system using the settings described in Table 1. Seven different amazon speed ion trap systems were used for generation of MS and MS n spectra in continuous polarity switching mode (for details refer to Table 2). Data were acquired using a data-dependent scheduled precursor list approach. Table 1: HPLC conditions used for the Toxtyper workflow LC settings Table 2: amazon speed ion trap MS and MS/MS parameters MS settings LC system Eluent A Eluent B Analytical column Flow rate Gradient Thermo Dionex Ultimate RSLC H 2 O,.1% formic acid, 2 mm ammonium formiate, 1% acetonitrile Acetonitrile,.1% formic acid, 2 mm ammonium formiate, 1% H 2 O Acclaim RSLC 1 C18 2.2 µm, 1A, 2.1 x 1 mm 5 µl/min. to 1. min: 1% B 1. to 8. min: 1% B to 95% B, linear 8. to 9. min: 95% B 9. to 9.6 min: 95% B to 1% B, linear 9.6 to 11 min: 1% B Scan mode Scan range Source Polarity MS n Acquisition Target mass m/z ICC. UltraScan 32.5 m/z sec-1 7-8 m/z Electrospray ionisation (ESI) Zero Delay Alternating polarity Data dependent using a Scheduled Precursor List with 8 cpds Active exclusion after 1 spectrum, reconsider if intensity increase by factor 5

Library search and reporting The data sets were post-processed using DataAnalysis (DA) 4.1 and the processed spectra were submitted to the DA 4.1 library search module. The whole process, up to final report generation and visualization of results in the web-based Compass OpenAccess interface, was driven by a predefined Toxtyper automation script. The automatically generated reports from the different labs were evaluated and used for generation of the final result tables. Results The goal of this study was to test the Toxtyper workflow (see Figure 1) with regard to its transferability and the reproducibility of results from lab to lab. The toxicologically relevant substances present in the three mixtures are routinely found in forensic toxicology (personal communication, Forensic Institute, Freiburg) and were chosen without regard to their retention times or molecular masses. The compounds were spiked into blank human serum at different concentrations (see Table 1). The spectral library, which consists of more than 8 compounds of clinical research and forensic toxicology interest, was generated in close collaboration with the Forensic Institute in Freiburg, Germany (see Bruker Application Note 72). All samples in the interlaboratory test were processed in a completely automated manner using Compass OpenAccess. After completion of a run, the user received a PDF report of the LC-MS n results; either by logging onto the web based COA system or by email. The automatically generated reports from the different labs were evaluated to demonstrate transferability of the Toxtyper solution and compare the overall performance of the different LC-MS ion trap systems. If a substance was not identified, the respective raw data file was inspected manually to find the cause. All compounds spiked into sample 1 could be identified by all participating labs. The identification results demonstrate the high sensitivity of the procedure. The results of the automatic reports are summarized in Table 4. Trimipramine was not identified by one lab. Inspection of the raw data revealed that in this lab, extensive coelution of matrix led to a mixed MS 2 spectrum and therefore to a score value below the cut-off for ID reporting. Metoprolol from sample 3 was not identified by two systems at HUG 1 and HUG 2. This was due to coelution with Mirtazapine, which led to a mixed MS 2 spectrum and subsequently to a score value below the cut-off for ID reporting. It should be noted that Metoprolol and Mirtazapine not only have very similar retention times, but also differ only slightly in mass (2 Da). This problematic combination of characteristics can be regarded as a very rare case. Sample Preparation SPE or LLE OpenAccess software for sample management Data acquisition by LC-MS n on amazon speed Library Search Automated ID result reporting Figure 1: Schematic of the Toxtyper library-based workflow. Table 3: Compounds spiked in human blank serum to test the labto-lab transferability of the identification workflow Sample 1 Sample 2 Sample 3 Methadone (25) Trimipramine (1) Duloxetin (6) EDDP (5) Amitryptiline (1) Nordoxepin () Diazepam (1) Zolpidem (5) Mirtazepine (5) Nordazepam (5) Oxazepam () Midazolam (15) Metoprolol () α-oh-midazolam (5) Temazepam (1) Fentanyl (3) Lidocaine () Given in brackets are the respective spiked concentrations in ng/ml

Common false positives were identified in the blank serum sample and the other samples, but these could be easily excluded after manual inspection of the reports and the respective raw data files. For example, a common false positive was benzododecinium. This compound is used as skin disinfectant during blood withdrawal and is present in the sample as a contaminant. The first page of the result report is shown in Figure 2. This page shows an overview of the results; consisting of base peak chromatograms (positive and negative ionization mode) and a table that summarizes the identification results using purity score, intensity, and mass/retention time shifts. A separate report page which displays the extracted ion chromatogram of the substance as well as its MS, MS 2, and if acquired, MS 3 spectrum is generated for each identified compound (see Figure 3). This enables potentially critical IDs for example false positives to be ruled out very quickly. The transferability and robustness of the fragmentation process on different Toxtyper systems is demonstrated by comparing the fragmentation reproducibility of spiked compounds. Figure 4 shows the MS 2 spectra of Amitriptyline recorded from spiked serum extracts of all participants and the respective library spectrum. SmartFrag technology provides reproducible fragmentation results that lead to the highest level of lab-to-lab transferability and reproducibility. Table 4: Results from the interlaboratory test Spiked Compounds Participants Sample 1 IKR IRM HUG 1 HUG 2 UK BDal 1 BDal 2 Methadone EDDP Diazepam Nordazepam Oxazepam Temazepam Sample 2 IKC IRM HUG 1 HUG 2 UK BDal 1 BDal 2 Amitryptiline α-oh-midazolam Fentanyl Lidocaine Midazolam Trimipramine Zolpidem D5-diazepam (IS) Ingredient of Serum Caffeine Theobromine Sample 3 IKC IRM HUG 1 HUG 2 UK BDal 1 BDal 2 Duloxetin Metoprolol Mirtazepine Nordoxepin D5-diazepam (IS) Ingredient of Serum Caffeine Theobromine

Result reporting of interlaboratory test serum 2 Base peak chromatogram positive ionization mode Base peak chromatogram negative ionization mode Search result table Figure 2: Result reports can be accessed by the web or sent by e-mail.

Detailed MS and MS 2 spectra results of the Toxtyper reporting for Amitryptilin Cmpd 7, AutoMS n (278.14), 4.89 min, Amitriptyline Extracted Ion Chromatogram Extracted ion chromatogram of identified compound Compound Spectra MS spectrum measured MS spectrum library MS 2 spectrum measured MS 2 spectrum library Figure 3: Result reports can be accessed by the web or sent by e-mail.

Transferability of MS MS fragmentation results from lab to lab Intens. 1 1 Score 98 91.6 Score 976 91.12 Score 98 15.4 15.1 14.92 117. 117.7 116.95 128.25 14.93 129.2 141.4 148.56 154.93 155. 154.88 178.95 179.3 19.92 19.99 19.95 RV Serum 2_128_RB6_1_11.d: +MS2(278.1), 4.73-4.78min #218-2139 BDal 1 4.98 217.92 233.99 RV SE 2_17_RB2_1_497.d: +MS2(278.), 4.73-4.77min #98-2121 BDal 2 5.8 218.4 234.4 RV Se 2_11_5.d: +MS2(278.3), 4.79-4.79min #2176-218 IRM 1 91.8 Score 994 15.11 117.9 128.98 14.82 155.7 178.88 191.2 4.9 217.93 233.89 RV Se 2_8352_RA8_1_7572.d: +MS2(278.14), 4.86-4.87min #2133-2142 234.2 HUG 1 1 1 91.17 Score 993 9.92 Score 989 116.84 14.84 14.97 116.92 129.8 141.6 128.84 14.79 154.76 154.9 179.3 178.86 19.82 19.9 5. 218.9 231.11 RV Se 2_158_RD7_1_27.d: +MS2(277.94), 4.94-4.96min #2334-2343 233.74 4.78 217.84 1724_RV SE 2_665_BD7_1_1663.d: +MS2(278.21), 4.72min #2159 233.96 HUG 2 IKC 1 1 9.94 Score 98 91.1 15.1 117.3 128.89 14.87 129.2 14.95 154.95 178.92 178.9 19.94 4.93 217.98 231.3 RV Se 2_16_RD5_1_271.d: +MS2(278.11), 4.98-5.min #211-2122 233.96 UK 4.9 218.3 231.4 RV Se 2_16_RD5_1_271.d: Library: Amitriptyline; IT ESI +MS2(278.78) (P: 98, F: 98, R: 98, M: 1) 1 117.3 15.8 154.93 19.91 233.83 91.18 128.9 14.96 178.91 4.91 217.93 Library 8 1 1 14 16 18 2 24 26 m/z Figure 4: Shown are the MS 2 spectra of Amitryptilin measured on 7 different amazon speed systems during the interlaboratory test. Summary and Conclusion The Toxtyper workflow offers a fast and robust identification tool for clinical research and forensic toxicology analysis. The combination of MS 2 /MS 3 spectral information and the respective retention time meets common criteria for identification of analytes. The results of the interlaboratory test demonstrated the efficiency and transferability of the complete workflow over seven independent systems in different research labs. The high rate of substances correctly identified in different laboratories reflects the superior performance of this approach. The high degree of automation offered by Compass OpenAccess is ideally suited for the transfer of this solution to diverse laboratories. The use of additional libraries to solve specific questions offers further possibilities; for example, high-throughput identification of certain substance classes, for Forensic applications.

Bruker Daltonics is continually improving its products and reserves the right to change specifications without notice. Bruker Daltonics 4-14, LCMS-92, 1828632 References [1] Hans H. Maurer, Karl Pfleger, Armin A. Weber: Mass Spectral and GC Data of Drugs, Poisons, Pesticides, Pollutants and Their Metabolites (11) [2] Birgit Schneider, Carsten Baessmann, Sebastian Götz, Arnd Ingendoh (9): Zero Dealy Polarity Switching for Ultra-fast MS/MS Screening Applications; Bruker Application Note LCMS-51 #264574 [3] Jürgen Kempf, Laura Huppertz, Susanne Vogt (Universitätsklinikum Freiburg, Germany), Markus Meyer, Sebastian Götz, Birgit Schneider (Bruker DaltoniK GmbH, Germany): Toxtyper a Comprehensive LC-MS n application for Clinical Research and Forensic Toxicology; Bruker Application Note LCMS-91, 1828629 For research use only. Not for use in diagnostic procedures. Not available in every country. Please contact your local sales representative for more information. Bruker Daltonik GmbH Bremen Germany Phone +49 ()421-25- Fax +49 ()421-25-13 sales@bdal.de www.bruker.com/ms Bruker Daltonics Inc. Billerica, MA USA Phone +1 (978) 663-366 Fax +1 (978) 667-5993 ms-sales@bdal.com Fremont, CA USA Phone +1 (51) 683-4 Fax +1 (51) 49-6586 ms-sales@bdal.com