TRAINING OUTLINE FOR PART TIME BUILDERS



Similar documents
Guide to Safe Building Practices

Text Box 1 Important Actions, Questions and Constraints to Consider on Standards and Vulnerability

Protecting Your Home From Hurricane Wind Damage

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

Repairing storm damaged roofs

Protecting Your Home from Wind Damage

Protecting YOUR NEW HOME FROM Wind Damage

Chapter 6 ROOF-CEILING SYSTEMS

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

Mark Cramer Inspection Services, Inc.

Repair of sheet metal roofs in cyclonic areas

Walls. Add Strength and Water Resistance When Repairing Your. Replace damaged framing members when walls are open

FCA CARPENTRY & JOINERY THEORY. 10 SIMPLE ROOF CONSTRUCTION Part 2

INSTALLATION. General. Important Note. Design. Transport

THIS GUIDE WAS PREPARED BY THE CYCLONE TESTING STATION WITH SUPPORT FROM NORTHERN TERRITORY, QUEENSLAND AND WESTERN AUSTRALIAN GOVERNMENTS

Metal Roofing Practical Design

Building Construction. Lightweight construction. Conventional Construction

SINGLE-FAMILY EARTHQUAKE (SEISMIC) RETROFITS

providing documentation that validates the year of construction. Acceptable documents include

Repairs, Remodeling, Additions, and Retrofitting

Chapter. Restoration of Damaged Structures

Good Craftsmanship Guide. Carpentry and Joinery- Carcassing

What is Seismic Retrofitting?

POST AND FRAME STRUCTURES (Pole Barns)

How to secure your property after a disaster

STANDARD OPEN PATIO COVER

Asphalt Shingle Application Requirements

Wind Mitigation Discount Plan

The Florida Building Code

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

Hurricane Damage. How Wind Forces Affect Homes

Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details

Patio Covers / Carports

NRG 75 CRF NRG GREENBOARD WALL SYSTEM

Minimizing Water Intrusion Through Roof Vents in High-Wind Regions

Advanced Wind Mitigation Methodologies Pt. 2 Online Retrofit Course. Section 1: Introduction

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Protecting Roofing Systems Against Windstorm Damage

Connection Solutions

CODE OF PRACTICE FOR THE CONSTRUCTION OF HOUSES: AN INSTRUCTION MANUAL FOR FOREMEN AND EXPERIENCED ARTISANS PART 2: STUDENT S MANUAL

Preformed Metal Roofing and Siding

EMERGENCY SHELTER HAITI

REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION

CARPENTRY - HOUSING. This is the sloping length of a right-angled triangle.

TABLE OF CONTENTS" SECTION 3: Comparing Standing Seam Metal to Other Metal Roofs PAGE 7"

ELIGIBILITY CHECKLIST:

Wood Truss Restraint and Bracing Guide


A study of hurricane mitigation cost effectiveness in Florida

Screw Patterns Roof & Walls TR-36 MD-36 TSM-32. PBR-Panel

How To Build A Gambrel Roof And A Gable End Roof

ONE-STOP S PERMIT INFORMATION PACKAGE FOR RESIDENTIAL PROJECTS

Timber Frame Construction

KAHU RESIDENTIAL ROOFING RRKA DETAIL LIST

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof

RESIDENTIAL ROOF PERMITTING A REFRESHER WORKSHOP September 11, 2014

SCHOOL RISK MANAGEMENT PLANNING LEVERAGING DATA, TOOLS AND PARTNERSHIPS

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

6 RETROFITTING POST & PIER HOUSES

INSTALLATION OF A BAY WINDOW

Installation Manual for STANDING SEAM ROOFING

Page & Turnbull imagining change in historic environments through design, research, and technology

ICC-ES Evaluation Report Reissued March 1, 2011 This report is subject to renewal in one year.

SUPER SHED. Indoor shelter for your outdoor tools.

SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION

1. GENERAL ADVISORY BASE FLOOD ELEVATION (ABFE) QUESTIONS

DIVISION V DWELLING PROGRAM. A. DWELLING ELIGIBILITY -- Risks eligible for the dwelling program are used solely for residential purposes.

High Wind & Hail Standards

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

Structural Assessment Report

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

ISO Types 1-6: Construction Code Descriptions

Wind Mitigation Inspection

Standard Technical Details

SECTION 3 ONM & J STRUCTURAL ANALYSIS

Structural Seismic Retrofits For Hawaii Single Family Residences With Post and Pier Foundations

Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training

Installation Instructions. Connector between an appliance to the Type B-Vent system. Single- and Double-Wall. DuraConnect

Detached accessory structures that contain no conditioned floor area are exempt.

Siting and settlement: The most important way to protect shelter from floods is to build in a place that is unlikely to be flooded.

THE REDLAND GUIDE TO BS 5534

Custom 30 x 20-8 Garage Plan Plan #g233 By SDS-CAD Specialized Design Systems

Bolting: Attachment Of The Mudsill To The Foundation

Residential Deck Safety, Construction, and Repair

In the Caribbean, August and September are peak months during the hurricane season that lasts from June 1 through November 30.

APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET

BRIDGE & SUPPLY COMPANY. Installation Guide. Ultra Includes:

Uncovered Decks & Porches

IGNITION-RESISTANT CONSTRUCTION: THE WHY BEHIND THE WHAT

General Instructions and Guidelines

8/18/14. Introduction to. Framing. Terminology and Concepts

REDLAND DRY BONDING GUTTER. Installation Instructions for Redland Dry Bonding Gutter

Transcription:

TRAINING OUTLINE FOR PART TIME BUILDERS This is a training outline for persons who get involved in repair work and minor building work, emphasizing disaster resistance and good practice. It is intended for delivery using evening or weekend classes, as it is aimed at persons not normally involved in building work. 1. Introduction to disasters: A disaster on any scale occurs when events overwhelm our ability to cope. This applies for a personal, community or national disaster. Natural hazards such as hurricanes or earthquakes are often national disasters for islands of the Caribbean, as they affect everyone. Unlike the case of large countries, there may be no unaffected community that can render assistance. For this reason, regional organisations are important (such as CDERA), and so are mitigation measures. In the Housing sector, a hurricane may affect thousands of buildings at once, and this has the capability to overwhelm the construction sector s capacity to respond to those needing their services. Many persons become active for a time to help rebuild, and this training is intended to assist the part time builders and tradesmen, as well as those working to repair their own buildings to ensure that rebuilt houses are able to withstand the next hazard with a much lower likelihood of damage. The trainee should be addressed by the building and housing officials as well as the National Disaster Organisation, so that the importance of good practice is reinforced and sources of backup advice are available. 2. What hazards do we face? The most common hazard that does the most damage in our region is Hurricanes. These bring not only high winds, but add high rainfall, causing flooding, landslides and mudslides, storm surge and storm waves. A mitigation plan that deals with the threat of hurricanes must deal with their many different effects. For the housing sector, additional threats of fires and earthquakes are to some extent taken care of if preparations are made for hurricanes, as masonry walls would already have reinforcement to withstand wind pressure, and nearby trees would be controlled to prevent damage.

3. What are safe building practices? Good building work is a compromise between cost, utility and resistance to damage. Safe building practices are based on experience, ie. what gets damaged during a storm (or earthquake etc). Building codes generally do not specify good practice, but simply a level of resistance to forces to be attained based on the best known data. The shape and design of a building affects the forces imposed upon it, while the materials and strength of the connections determines the resistance to those forces. Good building practice in a country is a combination of shape and design, materials and connections that can resist extreme events in a culturally acceptable way 4 Repairing roofs The underlying assumption here is that repairs to damage from hazards such as hurricanes, which are likely to return, should be resistant to damage a second time around. Roofing repairs should start with an assessment of the damage. This needs to both assess the overall situation, such as whether the damage warrants demolition, or whether the roof is still the proper shape. The connections between each element from galvanize sheet to foundation are like the links in a chain, any one of which may fail. The assessment needs to decide down to which connection in the chain the roof should be dismantled in order to start rebuilding. When exposing elements of the roof, it is wise to bring all connections up to standard, as the roof or rafters may not have blown off because the sheeting came off first. If the sheeting is properly fixed, the same rafters may then be the weakest connection and fail next time. Unless the damage is obviously limited and within the competence of the part time builder to assess, it is wise for them to seek technical assistance to advise on what to do, how much to demolish and whether to repair without changing the design or materials. Wherever possible, unless working on their own building, part time builders would be advised to work with other tradesmen and contractors who have the experience and technical backup so as to rebuild efficiently and safely. 5 Retrofitting roofs Retrofitting usually means in this use going back to strengthen, but is also now taken to mean to bring up to a standard, or to include the maintenance and replacement that should have been done. This is a standard of resistance to, say, hurricanes.

Too often it is not possible, because of technical or financial reasons, to bring a building up to the desired level of strength. A judgement must be made as to what detail or connection poses the highest risk, and an attempt made to address this area (to strengthen the weakest link in the chain). Safer building practices address these areas of damage strengthening the connections that carry the load from the sheeting (mainly an uplift load) down to the ground. When these standards are applied to an existing roof, it is termed retrofitting Technical areas A Overview of issues The following issues do not normally have to be addressed by this group, but in order to familiarize them with the decisions that must be made, they should be discussed. 1) Siting assessment The question of whether to rebuild a badly damaged house in the same place must be addressed, and whether there are activities that can reduce the vulnerability from particular hazards. 2) Demolition assessment A decision on whether to repair or demolish a building must be made by a competent person. If the building is out of shape, or the foundations have failed, this may be the quickest and least costly solution. 3) Damage assessment Deciding what to repair requires some level of dismantling of the structure, to determine what layer it is necessary to rebuild from. Determining what started the chain of events that resulted in the damage visible often requires some investigation but can be useful in order to prevent future repetition. 4) Re-roofing/redesign decision The client as well as a technical person must decide on whether to put back what was there before or whether to change the shape or design in order to provide more resistance to damage.

B Pitch/overhang adjustment, choice of materials For small buildings the builder would have some control over details such as overhang, and often, in very small structures, the pitch of the roof. The builder should be able to determine that the materials used are appropriate. A materials and connectors standards list is included in this outline. C Load path analysis The training should explain the basics of an analysis of the load path through the connections between building elements. This is a way of checking structures to ensure their resistance to the forces from hazards. D Details The following list of areas should be discussed with the trainee, with visual materials and where possible, examples of the connections and materials themselves. Roofing connectors, spacings, type and length These connections are: 1. Ridge capping 2. Galvanized sheeting fixings 3. Other roof coverings 4. Sarking fixings 5. Purlin/lath fixings 6. Rafter fixings 7. Wall plate fixings 8. Wall to foundations And in addition, 9. Collar ties (rafter to rafter) 10. Window shutters and hinges 11. Bracing timber walls 12. Foundations and Posts

F Standards for materials and connectors The trainee should be familiar with the following specifications and understand the reasons for their existence and use. Overhangs are less than 18 at eaves and gables unless special provision is made. Preferable overhang 12 (300 mm) or less. Roof pitch at least 22 degrees(or 1 in 4), preferably over 30 degrees Roof is hip shaped, preferable to gable All timber used in roofing will be pressure treated lumber or otherwise treated against termite attack Wall plate, minimum 4 x 3 (100x75 mm) to be held down by ½ (12 mm) bolts spaced at least at 4ft (1200 mm), preferable 3ft (900 mm), centres or other approved method Rafters will be secured by twisted metal hurricane straps or galvanized hurricane clips, one per rafter, or other approved method. Rafters will be at maximum spacing 2ft 6inch (750 mm), preferably 2ft. (600 mm) Every second pair of rafters will be connected against separation by collar ties or approved straps at the ridge Purlins (Laths) will be minimum section 1 x 4 inch (25 x 100 mm) set at maximum spacing 2ft 6inch (750 mm) and secured with two nails at each rafter intersection. Alternately, 2x3 inch (50 x 75 mm) minimum purlins fixed with one screw per rafter may be used. Steel based sheeting to be at least 26 gauge thickness (preferably 24 gauge.) Aluminum based sheeting to be at least 22 gauge thickness Sheeting is fixed at every corrugation at gables, every second corrugation at eaves and ridge, (preferably every corrugation), and every third in the center of the roof. Sheets are fixed with dome headed sheeting nails using timber fillets as spacers, drive screws with washers or with bolts and washers are preferable