Redwood Cabling Design Guide



Similar documents
InstaPATCH Cu Cabling Solutions for Data Centers

SYSTIMAX SCS PowerSum and GigaSPEED XL Cabling Installation Guidelines

Panduit 28 AWG Patch Cords Installation Guideline

MCR1900 Media Converter 19-Slot Chassis

Cabling Requirements for the District of Columbia on behalf of the Criminal Justice Coordinating Council

CommScope Intelligent Building Infrastructure Solutions (IBIS)

BIX Cross-Connect System Distribution Connectors, Multiplying Connectors and Modular Jack Connectors

Performance Verification of GigaSPEED X10D Installations with Fluke Networks DTX 1800 CableAnalyzer

Copper Pre-terminated Assemblies

Intelligent Cable Management Systems

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

InstaPATCH ZERO Solution Guide

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

White Paper. Power over Ethernet Plus Update and Cabling Considerations

Structured Cabling, Earthing & Equipotential Bonding

Laying the groundwork for a new level of Power over Ethernet

Category 6 Solutions. 4. Category 6 Solutions. 09/ IN TrueNet Structured Cabling. Introduction Cable Patch Panels... 4.

Tablet Management Rack 16

SYSTIMAX Solutions. GigaSPEED X10D Shielded (F/UTP, S/FTP) Solution Guide Europe, Middle East and Africa Regions.

Data Center Cabling Design Trends

Patch Cords / Cable / Cable Assemblies. Patch. Cords/Cable/ Premise Connectivity Systems. Cable Assemblies

TCTC Cabling Specifications

Accelerating Light. Copper Cabling Solutions. Category 6A

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

About the BitStorm 6051 POTS Splitter

Terminating 25-Pair Cable and 4-Pair Cross Connects

8-Port PoE Network Switch

10/ English Edition 1. Quick Start Guide. NWA1100N-CE CloudEnabled Business N Wireless Access Point

DIVISION 26 - ELECTRICAL SECTION CABLES FOR INSTRUMENTATION

with Component Rating A Simple Perspective

Running 1000BASE-T Gigabit Ethernet over Copper Cabling 30 March 1999 Colin Mick/The Mick Group with Bruce Tolley/3Com and Willem Wery/Intel

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

User Guide. Emergency Lighting Setup, Configuration and Administration. Redwood Software Version 4.0

VAC 50/60Hz Power Adapter

Installation Manual For Support Call or

GEU Port Gigabit Switch

Data Centre & Enterprise Solutions. RapidNet

Structured and Point to Point Network Cabling for Industrial Automation

The Permanent Link in Field Certification Reasons, Advantages, Testing Challenges

Design Guide. Universal Connectivity Grid. SYSTIMAX Solutions from CommScope

Applied Electronics. Commercial Dimming System UPDATE NOTICE

The migration path from 10G to 40G and beyond for InstaPATCH 360, InstaPATCH Plus and ReadyPATCH installations

Innovative Connectivity Solution for Maximum Performance and Security

Trends and Standards in LAN Cabling Systems Intelligent Buildings

IT Cabling Solutions

Data Center Standards Making Progress on Many Fronts. Jonathan Jew J&M Consultants, Inc

Power Separation Guidelines for SYSTIMAX Installations

MYTHBUSTING Takes on Shielded Cabling

Cabinets 101: Configuring A Network Or Server Cabinet

TELECOMMUNICATIONS STRUCTURED CABLING GUIDELINES AND SPECIFICATIONS. University of Chicago IT Services Infrastructure Services October 2011

Data Center. Pre-terminated. Patch Panel System. Cabling Systems Simplified. Patch Panels. 10G + Gigabit. Patch Cords. Plug & Play Installation

Mixed High-Speed Ethernet Operations over Different Categories of Bundled UTP Cable

IP DSLAM IDL Quick Installation Guide

LIEBERT VNSA Installation Sheet

Navigating the Pros and Cons of Structured Cabling vs. Top of Rack in the Data Center

HP UPS R1500 Generation 3

T1 Backhaul Connectivity Solution All Products :: Application Note

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

EDI Distributor Control Interface Wiring and Setup Instructions

InnoMedia ESBC B. Quick Install Guide. 1

Table of Contents. Fiber Trunking 2. Copper Trunking 5. H-Series Enclosures 6. H-Series Mods/Adapter Panels 7. RSD Enclosures 8

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

Specifying an IT Cabling System

Data Center Topology Guide

LocoNet, the Digitrax Difference

PC Tab INSTALLATION MANUAL SECURE-IT, INC. EAST LONGMEADOW, MA / (fax)

SECTION WEB-BASED POWER MONITORING COMMUNICATIONS SYSTEM

DVI DA2 and DVI DA 4 User Guide

UT Southwestern Medical Center Information Resources Cable Installation Standard

Session 2; Cabling Technology in the Data Centre Media Choices; Copper Twisted Pair

Extender for HDMI Long Range. GTV-HDMI-CAT5LR. User Manual

Organizing and Managing Equipment Rooms

AMP NETCONNECT CABLING SYSTEMS FOR DATA CENTERS & STORAGE AREA NETWORKS (SANS) High-density, High Speed Optical Fiber and Copper Solutions

Advantium 2 Plus Alarm

Rack Installation Instructions

Data Centers and Mission Critical Facilities Operations Procedures

1. Furnish and install faceplate and modular jacks at each single gang outlet as described below:

SECTION ACCESS CONTROL SYSTEM. CONDITIONS OF THE CONTRACT AND DIVISION 1, as applicable, apply to this Section.

White Paper: DC Resistance Unbalance Testing: Easy, Low-Cost Insurance for Your PoE Systems

Managing High-Density Fiber in the Data Center: Three Real-World Case Studies

InnoMedia ESBC B. Quick Install Guide. 1

SYSTIMAX Copper Solutions Designed for the Digital Generation

Power over Ethernet (PoE) Explained

Cable Installation Project

T0118 T2118 T3118. Instruction Manual

How To Create An Intelligent Infrastructure Solution

MEDMASTER EXTERNAL POWER SUPPLY

Installation & Weatherproofing Guide for ENCOM Broadband Radios

PCS300 Universal IP Reporting Module V1.0

LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX

Design Guide. SYSTIMAX GigaSPEED X10D Solution Design and Installation Guidelines. June 2015

SMART SENSOR COLLECTION

Top of Rack: An Analysis of a Cabling Architecture in the Data Center

BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability. Quick Start Guide NOTES

Transcription:

Redwood Cabling Design Guide

Executive summary This document reviews the system architecture and provides the cabling design guidelines and suitable operating environments for the implementation of a Redwood energy-effi cient LED lighting network. It complements the Redwood System Installation Guide and Redwood Commissioning and Administration Guide. There are three primary cabling design options illustrated in this guide: 1) Dedicated cabling terminated on patch panels in the closet and plugs near the sensors 2) Dedicated cabling terminated on patch panels in the closet and jacks near the sensors 3) Shared cabling terminated on patch panels in the closet and jacks near the sensors Each option has pros and cons, which are discussed to help the user select between them. The four primary tradeoffs that should be taken into account are: initial installed cost fl exibility for future modifications cabling bulk in pathways compatibility with Redwood end-point devices The optimal solution is dependent on the relative importance of these factors as well as the labor rate for the specifi c installation at hand. The fi rst two options are supported on CommScope cabling (recommended) as well as cabling components from other vendors that are fully compliant with ANSI/TIA-568-C, ISO/IEC 11801 and EN 50173-1 standards. The third option (cable sharing) is only supported on CommScope Category-6 (or better) cabling, as it has been thoroughly tested to support this more demanding confi guration. 2 For more information, visit seagrp.com

As noted, the three primary options include patch panels in the closet. Although patch panels are recommended, they are not required when deploying dedicated cabling (options 1 and 2 above). They are necessary when deploying shared cabling (option 3) to enable combining two Engine ports into one cable. The Appendix describes, in more detail, the rationale for recommending patch panels. The cabling confi gurations described in this guide are eligible for registration in the CommScope Enterprise 20-Year Extended Product Warranty and Applications Assurance Program for the Redwood application, provided that only CommScope cabling components are used from end to end, and all other terms and conditions of the program are met. Cables may be bundled in groups up to 48 cables for any portion of their length. The maximum ambient temperature for CommScope cabling is generally 50 C (122 F), although higher rated cables are available. The maximum ambient temperature for all cabling shall follow the manufacturer s guidelines and be at least 10 C (18 F) below the maximum recommended operating temperature of the cabling to accommodate the effects of cable heating while providing power. Local fi re and safety codes shall be followed. Local codes take precedence in case of confl ict with this guide. It should be noted that the shared Cat-6 option is a recently introduced option that is not compatible with all Redwood end-point devices at this time: Devices supporting cable sharing: Sensor-3, Universal Gateway, Dimmer Switch, Scene Controller Switch, some fixtures with embedded sensors (consult your Redwood representative) Devices NOT supporting cable sharing: LED gateway and some fixtures with embedded sensors The cabling confi gurations described in this guide are eligible for registration in the CommScope Enterprise 20-Year Extended Product Warranty and Applications Assurance Program for the Redwood application, provided that only CommScope cabling components are used from end to end, and all other terms and conditions of the program are met. Consult your SEA Group representative with specifi c questions. For more information, visit seagrp.com 3

Redwood solution architecture Overview The Redwood system is an innovative energy-efficient lighting system that provides advanced control capabilities and building performance data to improve how commercial buildings are lit, heated, occupied and managed. Other control systems on the market are generally incrementally added to the existing electrical lighting wiring. Whether dimming, detecting motion, implementing daytime lighting, or managing to a scheduler, all of these systems traditionally sit on top of the power system and have fixed dependencies on the circuitry. As a result, they are complex to set up, labor-intensive, expensive to install, and difficult to modify once deployed. Redwood s innovative approach combines power, sensing, control, and communications with a low-voltage, DC-powered, self-aware network architecture that automates lighting and enables building intelligence. This new approach to commercial lighting installs simply as one cohesive network of fixture and sensor hardware and is administered through a web-based dashboard from PCs and mobile devices. The Redwood design is comprised of the following elements: A highly efficient (>83%) centralized power Engine (Redwood 4834 Engine) capable of powering multiple light-emitting diode (LED) luminaires, with flexibility to support different currents and voltages for compatibility with various luminaires and applications. One of the following three sensor options: 1) A Redwood sensor located adjacent to each luminaire. This compact device incorporates a gateway for communicating with the Engine as well as a sensor pod for monitoring occupancy, light level and temperature. 2) A third-party fixture with an embedded Redwood sensor. 3) An LED Gateway and separate sensor pod located adjacent to each luminaire. The LED Gateway has one primary RJ45 jack for interfacing with structured Category cabling. The LED Gateway has two additional jacks, which may be connected to separate Engine ports for luminaires that require more than 34 watts of power. Utilizing three connections in parallel, high-power luminaires up to 102 watts can be supported. Intelligent algorithms that utilize the data gathered from the Redwood sensors to control the LED luminaires, thereby providing light only when and where it is needed. Optional Redwood Dimmer Switches, which can provide manual override control of light levels for one group of lights. Optional Redwood Scene Controller Switches, which can provide manual override control for multiple groups of lights simultaneously for setting scenes in large areas such as conference rooms. Optional Redwood Universal Gateway used to control one or two relays, which may be used to control AC-powered devices such as legacy fluorescent pendants, conference room projectors, etc. A scalable management and monitoring software system (Redwood Manager) that captures and stores data from the sensor arrays. 4 For more information, visit seagrp.com

Redwood does not manufacture the LED luminaires. Instead, Redwood partners with leading LED fi xture manufacturers to provide Redwood-compatible LED luminaires for commercial spaces and data centers. Redwood-compatible fi xtures are available for general interior illumination (downlights, pendants, direct/indirect, lay-ins, troffers), accent lighting (wall washes, sconces, linear cove lighting), task lighting, and under-cabinet lighting. Running the embedded Redwood Manager software, the Redwood Engine powers and communicates with Redwood Sensors, LED Gateways, Dimmer Switches, Scene Controllers, and Universal Gateways. It is the brains behind the Redwood platform and performs the sophisticated controls that signifi cantly reduce energy consumption. Multiple Engines may be linked together to power and control hundreds or thousands of fi xtures. Figure 1 shows the Redwood architecture. Redwood Manager (Software) Redwood Sensor LED Downlight Apps Redwood Open Application Framework Redwood Director Redwood Engines AC redwoodsystems Redwood LED Gateway LED Fixture AC AC AC Redwood Sensor Pod Redwood Scene Control Wall Switch Category Cabling Low Voltage Line Voltage Redwood Universal Gateway Redwood Sensor Pod AC Relay Fluorescent Pendant Figure 1: This shows a typical Redwood solution architecture. For more information, visit seagrp.com 5

Communication media The Redwood Engine centralizes power conversion and control processing for LED lighting. All the LED drivers are located in the Redwood Engine. The Redwood Engine takes line-voltage AC power, converts it to low-voltage DC, and distributes it via four-pair structured Category cabling to one of the Redwood end devices. Each of the Redwood end devices has an RJ45 jack, which accepts four-pair RJ45 plugs. In addition to the four-pair structured Category cabling between the Engine and the Redwood end devices, pre-connectorized low-voltage cabling assemblies are used to connect the Redwood end devices to adjacent devices as follows: LED fixtures come assembled with a whip cord, which either has an RJ45 plug (to interface with the RJ45 jack in Sensor-3 labelled luminaire ) or a 10-pin miniature connector (to interface with an LED Gateway). External sensor pods are shipped with a short RJ25 cord to connect to the LED Gateway or Universal Gateway. A Universal Gateway wiring harness (10-pin miniature connector to raw ended wires) provides the connection between the Universal Gateway and the AC relay control connection point. This wiring harness is ordered separately. This guide focuses on the structured Category cabling connectivity. Additional guidance on the low-voltage cabling assemblies can be found in the relevant Redwood specification sheets and Redwood instruction sheets. Each Redwood Engine is connected to the LAN via a standard 10/100/1000BASE-T port. The default policy for each Engine is construction mode, where each fixture turns on independently when motion is detected and stays on until no motion is detected for 30 minutes. Once the LAN is operational, the Engines are configured as part of the commissioning process, including assignment of lights into groups, assignment of policies, etc. For installations with up to eight Engines, one of the Engines can be configured as the master controller. For installations with more than eight Engines, a Redwood Director must be deployed. A Redwood Director is also required if integration with external applications/ systems is required. Consult the Redwood Networking Guide for detailed instructions on network configuration. CommScope recommends structured Category-6 (or better) connectivity for all network connections. 6 For more information, visit seagrp.com

Physical layer design This section describes the three primary structured Category cabling design options that can be deployed between the Redwood Engine and the Redwood end devices. Each option has pros and cons, which are discussed to help the user select between them. The three primary tradeoffs that should be taken into account are: initial installed cost fl exibility for future modifications cabling bulk in pathways The optimal solution is dependent on the relative importance of these factors as well as the labor rate for the specifi c installation at hand. All cabling components deployed shall be compliant with ANSI/TIA-568-C, ISO/IEC 11801 and EN 50173-1 standards as well as applicable local fi re and safety codes. In case of confl ict, local codes take precedence. The maximum length of the structured Category cabling (cable plus all cords) shall not exceed 100 meters. For more information, visit seagrp.com 7

Option #1: Dedicated cabling with patch panels and plugs Option #1: Dedicated Cat-5e Cabling with Patch Panels and Plugs Any Redwood end-device 95m Sensor 3 (shown) LED Gateway Integrated fixture Dimmer switch Scene Controller 5m Universal Gateway Figure 2: This illustrates dedicated cabling with patch panels in the closet and plugs at the end device. In this option, Category-5e (or better) cords, panels, and cable are used, along with field terminated plugs at the end device. Each channel consists of one cord in the closet, one port on a patch panel, one dedicated horizontal cable, and one field-terminated plug directly onto the solid conductor horizontal cable. It is advised to provision a small amount of slack near the sensor to enable minor repositioning of sensors if needed (if allowed by local codes). Note that Redwood-enabled fixtures come equipped with a short embedded cord and are, thus, not part of the structured Category cabling. To support this option, Redwood has introduced a field terminated plug. The Redwood plug can be fitted on Cat-5e and Cat-6 cables (see plug specifications for cable compatibility). Pros of cabling option #1 Lowest initial cost option Less apparatus in ceiling area (no jacks or mounting box in ceiling area) Readily field testable using hand-held testers (use channel adapter for ceiling area) Compatible with all Redwood end-point devices Cons of cabling option #1 Reduced flexibility (more difficult to move/reposition devices and more difficult to redeploy for other applications) Location of end of cable in user area is less controlled until sensor is mounted (may require interim management of cable slack loops) Not fully compliant with structured cabling norms 8 For more information, visit seagrp.com

Option #2: Dedicated cabling with patch panels and jacks Option #2: Dedicated Cat-5e (or better) with Patch Panels and Jacks Any Redwood end-device 90m Sensor 3 (shown) LED Gateway Integrated fixture 5m Dimmer switch Scene Controller 5m Universal Gateway Figure 3: This illustrates dedicated cabling with patch panels in the closet and jacks near the end device. In this option, Category-5e (or better) components are deployed. The cabling connectivity for two channels is shown (one in blue, one in green). Each channel consists of one cord in the closet, one port on a patch panel, one dedicated horizontal cable, one jack in the ceiling, and one cord in the ceiling. Note that Redwood-enabled fixtures come equipped with a short embedded cord and are, thus, not part of the Category cabling. In some jurisdictions, it may be acceptable to tie-wrap the jacks to a permanently installed building element. In other jurisdictions, though, the outlets may need to be mounted in a suitable mounting box such as a CommScope M101, M102 or M202 surface-mount box (not shown in above figure). Pros of cabling option #2 Most flexible option (easy to move/reposition devices) Fully compliant with structured cabling standards Easy redeployment for non-lighting applications Cons of cabling option #2 Highest initial cost option More apparatus in the ceiling area May require mounting box for jacks Easy demarcation for permanently installed cabling (clear test-points and handoff, which is most relevant if multiple parties are doing portions of the installation) Compatible with all Redwood end-point devices For more information, visit seagrp.com 9

Option #3: Shared CommScope Cat-6 (or better) cabling with patch panels and jacks Option #3: Shared Cat-6 (or better) with Patch Panels and Jacks (this option is only supported on Commscope cabling) Select Redwood end-devices 90m Sensor 3 (shown) Select Integrated fixtures 5m 5m Dimmer switch Scene Controller Universal Gateway Excludes LED gateway Figure 4: This illustrates shared CommScope Cat-6 (or better) cabling with patch panels in the closet and jacks near the end device. In this option, CommScope Category-6 (or better) components are deployed. The cabling connectivity for two channels is shown (one in blue, one in green, with the shared cable in orange). A Redwood SP12A splitter is plugged into one port on the patch panel (thereby providing two jack references). Similarly, an identical Redwood SP12A splitter is plugged into the jack in the ceiling (thereby providing two jack references). The splitter is internally configured to carry the Redwood power and communication signals on two pairs as opposed to four pairs. This cabling option is, thus, identical to option #2 except that each patch panel port, horizontal cable, and jack in the ceiling is shared between two ports. The number of Engine ports and sensors is identical to the other two configurations (i.e. only the permanent link portion is shared ). It should be noted that this option is only supported on CommScope Category-6 (or better) cabling from end to end. Redwood and CommScope have performed extensive testing and systems engineering to ensure that cable sharing can be supported on CommScope SYSTIMAX and Uniprise cabling even under the worst-case supported operating conditions. Neither the use of cabling from other vendors nor the use of CommScope Category-5e cabling is supported with Option #3 for both performance and safety reasons. In some jurisdictions, it may be acceptable to tie-wrap the jacks to a permanently installed building element. If mounting boxes are used, the jacks should be mounted with the tab up in the boxes to provide easy access to the release tab on the splitter. Pros of cabling option #3 Typically lowest total installed cost dependent on labor rate Reduced cable bulk (half as many horizontal cables) Most flexible option (easy to move/reposition devices) Fully compliant with structured cabling standards Easy redeployment for non-lighting applications Easy demarcation for permanently installed cabling (clear test-points and handoff, which is most relevant if multiple parties are doing portions of the installation) Cons of cabling option #3 Typically the highest cabling material cost Splitter may partially cover the default labeling area on some patch panels More apparatus in the ceiling area May require mounting box for jacks The number of drops in the ceiling for possible redeployment is cut in half. Not compatible with Redwood LED Gateway Not compatible with some fixtures with integrated sensors (consult your Redwood representative with specific questions) 10 For more information, visit seagrp.com

Physical layer installation and environmental considerations General requirements The Redwood Engine and the Redwood end-point devices shall be installed according to the Redwood System Installation Guide and Redwood Commissioning and Administration Guide (latest issues shall apply). Redwood compatible LED fixtures must be installed according to the vendor s installation instructions. For non-integrated fixtures, the Redwood Sensors and Sensor Pods must be installed next to each fixture. In general, the Redwood Scene Controllers and Dimmer Switches should be located near the fixtures they control. Ensure that cables and cords with the appropriate fire rating are used and installed in accordance with all applicable local regulations and practices. For instance, ensure that all cords used in a plenum environment are plenum rated. Prerequisite: Determine locations for all fixtures, Redwood Sensors, Redwood Dimmers & Scene Controllers, and Redwood Gateways and Sensor Pods. Please refer to the Redwood Commissioning and Administration Guide. Engine Installation Requirements In commercial office buildings, the Redwood Engines are typically located in 19 inch racks in the wiring closet and in close proximity to the RJ45 patch panels and cable management. Mounting brackets and mounting screws are included with each engine. Multiple engines are stacked at the bottom of each rack with patch panels and cable management located above the engines. This way the cables can be terminated on the back of sequential narrow depth patch panels while the Redwood Engines extend further back. This arrangement also ensures the weight is concentrated towards the bottom of the rack. The Redwood Engines may also be mounted in cabinets or other arrangements as long as clearance requirements and environmental operating specifications are met (see below). In data centers, where rack space often comes at a premium, the Redwood Engines may be rack or cabinet mounted but are often vertically wall mounted using the Redwood Wall Mount Kit (PN# WALLMOUNT-TRAY-1G). The required orientation for wall mounted engines is with the front/jack face of the engines facing down. Each engine requires a minimum front/back clearance of 6 (153mm) and may dissipate up to 375 watts of power. Minimum front and back clearances are a key design requirement for air circulation to ensure adequate dissipation of heat from the engines. All Redwood engines must be located in environments where they will remain within their rated operating specifications. Cable bundling and cabling operating temperature When remote power is applied to twisted-pair cabling, the temperature of the cabling will rise slightly due to resistive heat generation in the conductors. The level of temperature rise will increase when cables are bundled. The electrical performance of the cable will also degrade slightly due to the temperature rise. Category-5e (or better) cables that have a temperature rating of at least 60 C installed in open cable pathways such as cable baskets or perforated cable trays may be bundled in groups as large as 48 cables. The cables may be bundled along their entire length or a portion thereof. The maximum ambient operating environment for cables rated at 60 C shall not exceed 50 C. This ensures that all Category-5e (or better) cables in the bundle will remain below 60 C even when all cables in the bundle carry the maximum remote power simultaneously. Redwood and CommScope Enterprise R&D have performed extensive testing and systems engineering to ensure that cable sharing (option #3 above) can also be supported on CommScope SYSTIMAX and Uniprise Category-6 (or better) cabling under these same conditions. Cable sharing is only supported on Category-6 (or better) cabling from CommScope, and is NOT supported on any other cabling. By using cabling with higher temperature ratings and reducing the maximum cabling length, a Redwood solution can be deployed on cabling with a maximum ambient operating environment in excess of 50 C. Please direct specific questions to Redwood technical support staff for review. It should be noted that the maximum operating temperature for Redwood Engines, directors, sensors, gateways and wall switches is generally 50 C. Cables installed in conduit or enclosed trunking cannot dissipate heat as effectively and require smaller bundles. Many variables must be taken into account in assessing maximum cable bundles under these conditions. Please direct specific questions to SEA Group technical staff for review. For more information, visit seagrp.com 11

Cabling Installation Practices This guideline is not intended to serve as an installation guide for the Redwood equipment or the installed cabling. Design and installation of low voltage cabling must follow proper cabling installation practices and must comply with applicable national and local regulations, as well as manufacturer s instructions. The following documents provide relevant information for design purposes: SYSTIMAX SCS Design and Installation Guidelines Telecommunications cabling and associated standards such as ANSI/TIA/EIA (568-C, 569-B, 942), ISO/IEC 11801, and CENELEC (EN 50173, EN 50174). National and local codes such as the National Electrical Code (NEC) in the US Manufacturer s cable and component design and installation guidelines Additionally, the following installation practices must be taken into account: Telecommunications cables should be installed with proper pathway support. Cables must not be placed directly on fluorescent light fixtures, and must not be supported by, or attached to, ceiling tile support systems, electrical conduits, gas pipes, or water pipes. All cables and components must be installed according to manufacturer s guidelines, and should be visually inspected for proper installation. Cable installation should not significantly deform the cable jacket due to excessive pulling tension, overall twisting, compression, or bends over 90 degrees. Cable ties should be applied loosely to cable bundles and allow sliding of the cable tie across the cable bundle so as not to distort cable jacket. Avoid water, high humidity, chemical exposure, and cold temperature bending of cables. Installation temperature for copper cables varies depending upon the jacket material. However, at the extreme temperatures care must be exercised to prevent excessive kinking or increases in pulling tension. If CommScope cable has been stored below 32 F (0 C) for more than 8 hours, the cable must be conditioned at room temperature, 59 F to 86 F (15 C to 30 C) for at least 4 hours before installation. Maximum pulling tension of each cable should be kept below 110 N (25 lbf). The use of cable-pulling lubricant is not allowed. If slack loops are deployed, their length should be minimized. Ensure that cable is not twisted while creating a slack loop in order to avoid untwisting the cable pairs. Maintain the required bend radius and avoid cable kinks or jacket damage. Avoid untwisting and separation of cable pairs. Maintain twists to the point of termination and avoid pair wrapping. Manufacturer s specifications for cable fill limits in conduit and pathways must be followed. Cabling must not exceed 23 cm (9 in.) depth, or 15 cm (6 in) for standards compliance. Power separation of installed cabling must comply with applicable local or national safety regulations, as well as manufacturer s guidelines for transmission performance. Bonding and grounding practices must comply with applicable local or national safety regulations. 12 For more information, visit seagrp.com

Appendix: Additional physical layer design options Support for VisiPatch 360 in place of modular panels and jacks CommScope s VisiPatch 360 is a versatile, high-density, high-performance alternative to modular panels. It is also often used as a consolidation point for zone wiring architectures in place of jacks in the ceiling. This solution can be utilized with both dedicated Category-5e cabling as well as shared CommScope Category-6 cabling. Due to the versatility of the VisiPatch 360 solution, there are too many physical layer options to list here. Some of these options may be very attractive in certain environments offering low initial installed cost and high flexibility for future modifications. Please consult your CommScope cabling representative for additional information and approval of specific architectures. Pros of VisiPatch 360 in place of panels and jacks Very low initial deployment cost Can be wall mounted (no rack space needed) Can be installed before racks are present Supports cable sharing without modular splitters Cons of VisiPatch 360 in place of panels and jacks May require proprietary VisiPatch 360 patch cords Zone deployments may require longer cords, if zone box is used in ceiling Support for direct connections from cable to Redwood Engines (i.e. elimination of patch panels) Most cabling installations deploy modular patch panels (or VisiPatch panels) in the wiring closet to simplify administration, simplify testing, and improve flexibility. CommScope strongly recommends the use of patch panels, but does not require them for Redwood installations. In situations where the likelihood of equipment being moved within the lifetime of the building is low, the small incremental cost of the patch panel and corresponding patch cord may not be justified. Note that patch panels (or VisiPatch 360 panels) are required to deploy cable sharing. To reiterate, CommScope strongly recommends the use of patch panels, but will support installations without patch panels. Pros of direct connections Low initial cost (requires only field-terminated plugs) Does not consume rack space (no panel is required) Cons of direct connections More difficult administration and reconfiguration (challenging to connect a specific cable to a specific equipment port with dressed cables) More difficult to identify specific horizontal cables during troubleshooting (less friendly/accessible labeling) Less clear demarcation for permanently installed cabling (no clear test-points and handoff, which is most relevant if multiple parties are doing portions of the installation) Can t support cable sharing on CommScope Cat-6 cabling (increasing cable bulk) For more information, visit seagrp.com 13

Frequently Asked Questions Question: What are the testing requirements for the Category cabling used to support Redwood Answer: Continuity testing to detect pair continuity, opens, shorts, reversals and transpositions is mandatory for all installations and must be performed on 100 percent of the copper cabling runs. Performance testing of the permanently installed cabling is recommended but not mandatory. Question: Do patch panels have to be rack mounted? Answer: No, patch panels can be wall mounted using means that enable access to the back for initial termination and future inspection. In addition, although CommScope strongly recommends the deployment of patch panels for administration and future flexibility, they are not required. Question: We are renovating our existing building and planning to abandon our obsolete Category-5e cabling. Can abandoned cabling be re-provisioned for use with Redwood systems? Answer: There is a high likelihood that all or a high portion of cabling needs can be met by salvaging the obsolete cabling. Please direct specifics to our technical support for additional guidance. Question: Which pin-assignment arrangement does CommScope recommend for terminating conductors? Answer: CommScope recommends the TIA-568B pin assignment. Whichever pin assignment is used, it must be used consistently throughout the installation. Question: Can foiled cabling (F/UTP) or cabling with a shield around each pair (S/FTP) be used? Answer: CommScope recommends the use of U/UTP cabling to minimize the stiffness of cables and cords, but F/UTP and S/FTP cables are also supported. Question: When deploying cable sharing, does every cable at the patch panel need to deploy cable sharing? Answer: When deploying cable sharing, all cabling terminated on the patch panel must be CommScope Category-6 cabling. Splitters are needed only on those ports of the patch panel where cable sharing is desired. Question: Are splitters for cable sharing compatible with all CommScope patch panels that have 24 ports per U? Answer: Somewhat. CommScope recommends the use of patch panels where all 24 ports in the patch panel are in a single aligned row. FlexiMAX panels where individual jacks are staggered alternatively up/down will result in extension above the U space when splitters are inserted into the upper staggered locations and below the U space when splitters are inserted into the lower staggered locations. To avoid interference, blanking panels should be used above and below the group of patch panels or a 0.5U space should be allocated. Where termination of individual jacks is desired, another alternative is to deploy CommScope s new M2400 panels, where all 24 individual M-series jacks can be terminated in a single aligned row in the panel, thus avoiding potential interference. Question: Can I disconnect structured Category cabling on a Redwood solution while power is on? Answer: Yes. When the flow of electricity is interrupted via disconnect, the associated momentum results in inductive kick, which will cause a few sparks in rapid succession. A common example of severe inductive kick and the associated sparks can be observed when unplugging a vacuum cleaner while running. Standards-compliant Category-5e (or better) cabling and all Redwood end points are designed to withstand the negative effects of inductive kick when disconnected while carrying current. Cable sharing results in currents per contact in excess of those supported by standards, but all of CommScope s Category-6 and Category-6A connectors were designed with adequate margin to withstand these higher current levels. Question: Can the configurations utilizing the Redwood fieldterminated plug be registered for the CommScope 20 Year Extended Product Warranty and Applications Assurance? Answer: The configurations using the Redwood field-terminated plug can be registered for the CommScope 20 Year Extended Product Warranty and Applications Assurance, provided that only CommScope cabling components are used from end to end, and all other terms and conditions of the program are met. Applications Assurance for these configurations is limited to the Redwood application. 14 For more information, visit seagrp.com

www.seagrp.com Visit our website or contact your local SEA Group representative for more information. All trademarks identified by or are registered trademarks or trademarks, respectively, of CommScope, Inc. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to CommScope products or services.