Precise, Reliable and Innovative Air Conditioning for Information and Communication Technology



Similar documents
IT Cooling Solutions. DFC² Direct Free Cooling for Data Centres. Energy-efficient, reliable and available around the world

IT Cooling Solutions. DFC² Direct Free Cooling for Data Centres. Energy-efficient, reliable and available around the world

Monitoring. STULZ The natural choice. Around the clock Around the world

IT Cooling Solutions. STULZ AirModulator, AirBooster and AirBooster Pro. Air Flow Management for Data Centres

STULZ the natural choice. Tel-Air-2 Series. Telecom Line

Data Centre Cooling: Don't Waste Money on the Wrong Solution

IT Cooling Solutions. Wall-Air Series Displacement Evolution. Telecom-Line

Elements of Energy Efficiency in Data Centre Cooling Architecture

IT Cooling Solutions. CyberAir 2 Precision Cooling Solutions. Making more efficient use of your resources

STULZ View On DataCenter Cooling

State of the Art Energy Efficient Data Centre Air Conditioning

IT Cooling Solutions. Precision Cooling Solutions. Maximum efficiency in data centre air conditioning

Free Cooling for Data Centers

CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

CRAC Precision climate control units for data centres

CoolTeg Plus Chilled Water (CW) version: AC-TCW

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

Absolute and relative humidity Precise and comfort air-conditioning

- White Paper - Data Centre Cooling. Best Practice

Bring the fresh in. Dedicated Outside Air Systems

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

INFO HTK. Hybrid dry cooler. The reference for hybrid dry cooling ,000 kw

AIRAH Presentation April 30 th 2014

THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER

5-21kW. Ecotel Indoor Range. - 21kW. > Ecotel Indoor Range. Typical Applications

Blade Server & Data Room Cooling Specialists

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Energy efficient data centre cooling. InRack Cooling & The Intelligent Cooling System. aircold.dk

EHDC. Cooling system for Data Center and server cabinets.

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

How and Why Mission- Critical Cooling Systems Differ From Common Air Conditioners

News in Data Center Cooling

Tech Byte 27: Small Computer Room and IT Closet Cooling

HVAC Infrastructure Retrofit Solutions

Legacy Data Centres Upgrading the cooling capabilities What are the options?

Direct Fresh Air Free Cooling of Data Centres

IT Cooling Solutions. The Whole Range of. Data Center Cooling Solutions

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED.

Eaton 93PM UPS Where aesthetics meet intelligence.

How To Use Rittal'S Rizone

Phase Modular Finally the benefits of Modular ups are for all

Defining Quality. Building Comfort. Precision. Air Conditioning

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

More efficiency in office buildings with HVAC, lighting and security

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Element D Services Heating, Ventilating, and Air Conditioning

60-150kW. For more information on Airedale visit SmartCool kW. > SmartCool.

Education Evolution: Scalable Server Rooms George Lantouris Client Relationship Manager (Education) May 2009

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

All the best brands all under one roof

DTU-52 Series. High-Power Digital TV Transmitter. Features

Hiwall Hiross for Telecom. High Performance Air Conditioning

JAWAHARLAL NEHRU UNIVERSITY

Nordic Heat Pump Product Guide

White Paper Rack climate control in data centres

Lesson 36 Selection Of Air Conditioning Systems

Knürr DCL Modular Rack Cooling from 6 kw to 60 kw

Chilled Water Precision Air Conditioner For Critical Application

1116, Suenaga, Takatsu-ku, Kawasaki , Japan

System integration oriented data center. planning. In terms of ATEN's eco Sensors DCIM solution

by knürr CoolTherm Server cabinet technology with outstanding benefits up to 35kW cooling capacity Blade-Server server optimized!

How To Improve Energy Efficiency Through Raising Inlet Temperatures

Electronic Control Devices The European Product Catalogue 2007

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

Overview of Green Energy Strategies and Techniques for Modern Data Centers

Apartment and Communal Heating Solutions

In Row Cooling Options for High Density IT Applications

Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)

Site Preparation Management Co., Ltd. March 1st 2013 By Nara Nonnapha, ATD UPTIME

Sensor Monitoring and Remote Technologies 9 Voyager St, Linbro Park, Johannesburg Tel: ;

Reducing Data Center Energy Consumption

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

5-60kW. EasiCool Range. - 60kW. Typical Applications

Eni Green Data Center - Specification

Precision Cooling for Business-Critical Continuity. Liebert PCW. Cool the Cloud

System solution for data centres

Energy Efficiency Best Practice Guide Data Centre and IT Facilities

Comprehensive Solutions for Data Centers. Rely on Siemens for maximum uptime, reliability, and efficiency.

Questions to be responded to by the firm submitting the application. Why do you think this project should receive an award? How does it demonstrate:

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Multi-Node Server Enclosure

RiMatrix S Make easy.

SPECTRACOOL AIR CONDITIONERS PENTAIR EQUIPMENT PROTECTION MCLEAN IS NOW HOFFMAN COOLING

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle

Paul Oliver Sales Director. Paul Oliver, Airedale Tom Absalom, JCA

Modular Data Center Cooling. Ultra High Efficiency. Oasis Optimum DCIE

Screw Compressors ESM Fixed Speed & VS Variable Speed

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems

Heating, air-conditioning, cooling

Liebert : The Right Cooling For IT Environments. Precision Cooling For Business-Critical Continuity

Improve competiveness of IDC and enterprise data centers with DCIM

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

vacon ac drives for mining & minerals

Transcription:

STULZ the natural choice Precise, Reliable and Innovative Air Conditioning for Information and Communication Technology

2 Perfect Air Conditioning for Secure ICT Technology

Innovative blade constructions, multi-core processors and UMTS are continuously improving the performance of modern ICT technology. However, as performance increases so do thermal loads and air conditioning requirements, along with operators concerns about the operating reliability and availability of their infrastructure. State of the art precision air conditioning technology from STULZ removes these concerns, as it provides maximum reliability for your information and telecommunications equipment. The entire range can be installed individually STULZ precision air conditioning units include circulating air systems, cold water systems and high-density racks. Through their diverse designs and dimensions, they can provide the perfect customized solution for your requirements combining flexible use, the ideal configuration and tried and tested reliability. Find out more and choose precision air conditioning from STULZ. Circulating air Compact DX and CW MiniSpace AirBooster CyberAir Telecom-Line Water CyberCool High-density CyberChill 3

The Perfect Solution for Any Situation In general, a distinction is made between comfort and precision air conditioning. While comfort air conditioning creates a pleasant environment for people, precision air conditioning technology provides reliable cooling that is geared towards the requirements of technical infrastructure. Dedicated technology rooms in data centres or switching stations require precisely controlled relative humidity, room temperature, air conduction and air distribution. Precision air conditioning units from STULZ enable you to create precisely defined climatic conditions with pinpoint accuracy and outstanding reliability. Latent or Sensible Cooling The sensible part of the cooling capacity reduces the temperature, while the latent part dehumidifies the air. Comfort air conditioning units can use up to 50% of their energy for dehumidification, whereas precision units convert more than 95% of the energy used exclusively into cooling capacity. The technology required to achieve this pays off quickly in terms of lower operating costs. Air Distribution, Heat Dissipation and Filtration Precision air conditioning units from STULZ filter and circulate three times the amount of air as comfort units with the same rated capacity. They reliably dissipate isolated thermal loads even from distant corners of the room, while continuously monitoring and precisely controlling the temperature and air filtration. Controlled Temperatures Information and communication technology only works reliably and without faults within a relatively narrow temperature range. STULZ precision air conditioning units ensure optimum temperature accuracy with maximum tolerances of +/- 1 C, while comfort units can normally deviate from the set value by as much as +/- 3 C. Highly sensible cooling capacity = Low operating costs Optimum air distribution and filtration with precision air conditioning Precision air conditioning unit: Capacity 300 m 3 /h per kw Precise temperature control Precision air conditioning unit: Precision temperature control 24 C +1 K -1 K ±1 C t Comfort air conditioning unit: Capacity 100 m 3 /h per kw Comfort air conditioning unit: Comfort temperature control +3 K Precision air conditioning unit: 0 5% Air dehumidification Comfort air conditioning unit: 40 50% Air dehumidification 24 C -3 K ±3 C t 4

Controlled Humidity Unlike comfort air conditioning units, precision units feature strictly controlled and accurate dehumidification (tolerance +/- 5% relative humidity), as too much humidity can lead to condensation and corrosion, while too little can cause static charges, data loss and damage to hardware. Excellent Reliability Comfort air conditioning units mainly operate in summer and only for a few hours each day. By contrast, precision units need to be available whenever the electronic equipment to be cooled is in operation. This is normally the case for 24 hours a day, 365 days a year. This is why STULZ makes such high demands on the quality of their precision air conditioning units and is able to offer high availability systems with 99.999% reliability. Precise humidity control Excellent reliability with 24 hrs/day continuous load Precision air conditioning unit: Controlled dehumidification 0 h 1 h Comfort air conditioning unit: Uncontrolled dehumidification Months/year January February March April May June July August September Precision air conditioning October (8,760 hrs/year) November December Comfort air conditioning (1,200 hrs/year) 0 12 24hrs 5

Circulating Air A Breath of Fresh Air for Sensitive Technology Most precision air conditioning systems for IT, telecommunications and technology rooms are circulating air systems designed specifically for the individual thermal loads that occur. The more technology is installed in a room and the greater the waste heat from the hardware, the more care is required in planning and designing the air distribution. STULZ precision air conditioning units enable you to base your planning on maximum reliability regardless of whether the performance requirements are simple or complex. MiniSpace If you need precise, reliable and economical air conditioning for small technology and server rooms, the MiniSpace series provides a space-saving, microprocessor controlled solution. MiniSpace Cooling capacity, total kw 5 23 Cooling capacity, sensible kw 5 21 Air volume m 3 /h 2,000 7,000 Compact DX and CW If you need to reliably dissipate heavy thermal loads and keep an eye on your investments, Compact DX and CW represent a professional solution based on proven technology. Compact DX, single and double circuit Cooling capacity, total kw 17 104 Cooling capacity, sensible kw 17 89 Air volume m 3 /h 5,500 24,000 Compact CW Cooling capacity, total kw 12 118 Cooling capacity, sensible kw 11 96 Air volume m 3 /h 3,200 20,000 Compact DX MiniSpace Compact CW 6

AirBooster Mounted in the false floor, the AirBooster conveys up to 1,200 m 3 /h of cold air directly to the front of a high-density rack. This is three times the amount delivered by conventional ambient air coolers and is normally sufficient for targeted rack cooling. AirBooster Air volume m 3 /h 1,200 Rated electrical input W 85 7

Circulating Air CyberAir DX and Dual Fluid Units Cooling capacity, total kw 18 104 Cooling capacity, sensible kw 18 89 Air volume m 3 /h 5,200 24,000 CyberAir Low Noise DX and Dual Fluid Units Cooling capacity, total kw 18 73 Cooling capacity, sensible kw 18 66 Air volume m 3 /h 4,900 18,400 CyberAir CW Units Cooling capacity, total kw 30 146 Cooling capacity, sensible kw 26 120 Air volume m 3 /h 6,500 29,000 CyberAir CW2 Units Cooling capacity, total kw 26 103 Cooling capacity, sensible kw 24 89 Air volume m 3 /h 7,500 26,000 8

Maximum Performance for a Reliable Infrastructure With the development of its CyberAir precision air conditioning series, STULZ is setting new standards in energy efficiency, compact design and serviceability. If you want cutting-edge air conditioning technology and to cut your operating costs, put your trust in CyberAir s innovative EC fan technology and new control concepts. 12% Less Space For a cooling capacity of 42 kw, a CyberAir precision air conditioning unit requires an installation area of just 1 m 2. Central Control and Monitoring of Modular Systems State of the art control engineering means that up to 31 CyberAir precision air conditioning units can be combined into a single network and integrated into central building services systems. This gives you full control of your air conditioning at all times. Up To 60% Less Energy In contrast to conventional technology, CyberAir precision air conditioning units incorporate state of the art EC fan technology and feature a free cooling option. This cuts energy costs by up to 60%. 5 db(a) Less Noise Noise-absorbing materials that meet the Öko-Tex 100 standard, ingenious fan configuration and smooth, optimal air path reduce the noise emissions from CyberAir precision air conditioning units by more than 5 db(a). 9

High-Density Reliable Dissipation of Isolated Thermal Loads Modern server technologies have higher performance but take up less and less space. This can lead to high thermal loads at isolated points, which are difficult to eliminate with conventional air conditioning technology. This is why STULZ CyberChill server racks are directly cooled with water. This enables thermal loads of up to 35 kw per rack to be reliably dissipated. They can either be added to existing data centres or utilised as a stand-alone solution. 10

CyberChill Water Cooling, When Air is Not Enough If the thermal loads in server racks exceed 5 kw, conventional air conditioning systems cannot deliver sufficient air. CyberChill uses a recirculation air cooling circuit to cool the servers, removing the intense local heat load by means of an air to water exchanger. 11

Water Cold Water Systems Efficient and Reliable Water is the most efficient medium for heat transfer. This is why water is increasingly being used to cool technical equipment in ICT and medical technology. Demand control concepts and free cooling options ensure that energy consumption is low. This enables you to cut your operating costs and reduce the burden on the environment. 12

CyberCool CSO and CLO Outdoor Chillers: Outdoor Installation for Demanding Jobs CyberCool Outdoor Chiller units are cold water systems that use speed controlled fans, timed controllers and low-noise, highly efficient scroll compressors to achieve excellent energy efficiency and quiet operation. An optional controller is available that automatically selects Free cooling, Mixed mode and Compressor cooling, reducing energy consumption by up to 40 % compared to conventional controllers. In addition to the CyberCool CSO, the noise reduced CyberCool CLO design is available. This unit provides the same options but operates at a noise level around 10 db(a) lower, making it ideal for use in areas that are sensitive to noise. CyberCool Outdoor Chiller CSO Cooling capacity kw 36 235 CyberCool Outdoor Chiller CLO Cooling capacity kw 36 157 CyberCool Indoor Data Chiller: Cooling Water with Minimal Space With their compact design, CyberCool Indoor Data Chillers produce enough cooling water for a cooling capacity of up to 100 kw and yet require an area of just 0.89 m 2. They fit through standard doors or and lifts, can be combined on a modular basis into redundant systems with 99.999 % reliability and can be installed in areas of buildings that are sensitive to noise. CyberCool Indoor Data Chiller CSI Cooling capacity kw 21 100 CyberCool Pump&Transfer: Compact System Separation Connecting high-density racks to the central cold water supply requires hydraulic separation to minimise the water quantity, pressure and risk of leaks in sensitive IT areas. CyberCool Pump&Transfer provides this separation and, as a twin circuit system, allows a redundant cold water supply to be set up. CyberCool Pump&Transfer Cooling capacity kw 20 100 CyberCool CyberCool Pump&Transfer CyberCool Indoor Data Chiller 13

Circulating Air Air Conditioning Units for Telecommunications Containers, shelters, base stations, distribution centres and switch cabinets for telecommunications make special demands in terms of air conditioning technology. The Telecom-Line includes the ideal design for every situation factory tested, filled with cooling agent and ready to operate immediately. 14

» Wall-Air: Air conditioning unit for outdoor wall mounting» Tel-Air: Air conditioning unit for vertical indoor installation» Split-Air: Split air conditioning unit for indoor and outdoor installation» Wind-Air: Window air conditioning unit for complete or partial indoor and outdoor installation» Mini-Air: Switch cabinet air conditioning unit for vertical indoor installation» Compact-Air: Switch cabinet air conditioning unit for vertical outdoor installation» X-Line: Air/air heat exchanger for switch cabinets Wall-Air Cooling capacity, total kw 3.8 20.8 Cooling capacity, sensible kw 3.8 19.5 Air volume m 3 /h 1,000 5,700 Tel-Air Cooling capacity, total kw 3.8 11.1 Cooling capacity, sensible kw 3.8 10.4 Air volume m 3 /h 1,000 3,000 Split-Air Cooling capacity, total kw 3.8 8.4 Cooling capacity, sensible kw 3.8 7.8 Air volume m 3 /h 1,000 2,150 Wind-Air Cooling capacity, total kw 3.8 8.8 Cooling capacity, sensible kw 3.4 7.8 Air volume m 3 /h 1,000 2,700 Mini-Air Cooling capacity kw 0.8 3.9 Air volume m 3 /h 220 1,150 Compact-Air Cooling capacity kw 0.8 3.9 Air volume m 3 /h 220 1,150 X-Line Specific heat transfer W/K 60 130 Split-Air Tel-Air Wall-Air Compact-Air Mini-Air X-Line Wind-Air Split-Air 15

C1002 Standard controller with 4-digit 7-segment LED display Key pad Integrated sequencing for connecting two units C1010 4-line text based LC display Sequencing for up to 35 units Continuous condensing pressure regulation Software update and system configuration using hardware key (optional) Separate control unit for remote control (optional) C6000 Chiller LCD graphic display Integrated sequencing for up to 6 units High pressure management Free cooling management Continuous condensing pressure regulation C7000 High redundance and availability due to autonomous controllers Integrated sequencing for up to 31 units Zone operation Filter control management CW standby management Free cooling control User interface with graphic display and remote control (optional) 16

Intelligent Control and Central Monitoring of Precision Air Conditioning STULZ s intelligent CompTrol control concepts ensure reliable operation of precision air conditioning units and cold water systems. Setpoint entry and adjustment, unit monitoring and operating data output using separate control units, PC or connection to existing building services systems. This allows you to maintain an overview and keep control at all times. Interfaces to Building Services and Internet The STULZ MIB7000 (Multifunctional Interface Board) has an integrated sequencing function for up to 32 units. The RS485/RS232 serial interfaces support all standard building services systems. The STULZ WIB7000 (Web Interface Board) communicates using the IP protocols SNMP and HTTP. Configuration and operation are browserbased. The STULZ LIB7000 (Lon Interface Board) enables all units to be integrated into LonWorks technology. C4000 C5000 C1002 C1010 C6000 C7000 Gateways for STULZ controller systems Data protocol Gateways SDC C7000 Advanced/MIB7000 Modbus C7000 Advanced/MIB7000 P90 C7000 Advanced/MIB7000 ALARM Remote monitoring and control SNP Network bus Saia bus C7000 Advanced/MIB7000 C7000 Advanced/MIB7000 C7000 Advanced/MIB7000 BACnet MIB7000 SMS Display/ visualization Ni bus LonTalk SNMP MIB7000 LIB7000/LIB7000 + MIB7000 WIB7000 HTTP WIB7000 N2 bus METASYS Unigyr bus CFE E-mail Operation Sinec L2 bus CP524 Alarm/ ZLT Remote maintenance HTTP/ SNMP Customer 17

18

STULZ Expertise and Partnership Bring Tailored Solutions STULZ precision air condition units feature optimum quality and reliability. From individual units with a cooling capacity from 0.3 kw through to modular systems with several megawatts of capacity, STULZ offers a complete range of products that provide optimum solutions for every situation. Air conditioning experts support you in design, realization, installation and maintenance of your system. In case of emergency, the STULZ service organisation provides rapid assistance and maximum availability. Reliable Air Conditioning Available Worldwide Whether it is in Rio, New York, Shanghai or Tokyo: Operators of ICT systems throughout the world rely on precision air conditioning technology from STULZ. Put your trust in STULZ with our 30 years of experience, high availability quality products, expert advice and reliable service. Wherever you need us, we are not far away. www.stulz.com/global 19

STULZ HEADQUARTER D STULZ GmbH Holsteiner Chaussee 283. 22457 Hamburg Sales Germany, Tel.: +49(40)55 85-306 Sales International, Tel.: +49(40)55 85-269 Fax: +49(40)55 85-308. products@stulz.de STULZ SUBSIDIARIES AUS E STULZ AUSTRALIA PTY LTD Unit 21, 287 Victoria Rd. Rydalmere NSW 2116 Tel.: +61(2)96 38 70 00. Fax: +61(2)96 38 70 22. sales@stulz.com.au STULZ ESPAÑA S.A. Calle Lluvia Nº 1. 28918 Leganés (Madrid) Tel.: +34(91)517 83 20. Fax: +34(91)517 83 21. info@stulz.es F STULZ FRANCE S. A. R. L. 107, Chemin de Ronde. 78290 Croissy-sur-Seine Tel.: +33(1)34 80 47 70. Fax: +33(1)34 80 47 79. info@stulz.fr GB I IN STULZ U. K. LTD. First Quarter. Blenheim Rd.. Epsom. Surrey KT 19 9 QN Tel.: +44(1372)74 96 66. Fax: +44(1372)73 94 44. sales@stulz.co.uk STULZ S.P.A. Via Torricelli, 3. 37067 Valeggio sul Mincio (VR) Tel.: +39(045)633 16 00. Fax: +39(045)633 16 35. info@stulz.it STULZ-CHSPL PVT. LTD. 006, Jagruti Industrial Estate. Mogul Lane, Mahim. Mumbai - 400 016 Tel.: +91(22) 56 66 94 46. Fax: +91(22) 56 66 94 48. info@stulz.in NL STULZ GROEP B. V. Industriecentrum Bovenkerk. Postbus 75. 1180 AB Amstelveen Tel.: +31(20)54 51 111. Fax: +31(20)64 58 764. stulz@stulz.nl PL USA STULZ POLSKA SP. Z O.O. ul. Włodarzewska 69. 02 384 Warszawa Tel.: +48(22)883 30 80. Fax: +48(22)824 26 78. info@stulz.pl STULZ AIR TECHNOLOGY SYSTEMS (SATS), INC. 1572 Tilco Drive. Frederick, MD 21704 Tel.: +1(301)620 2033. Fax: +1(301)662 5487. info@stulz-ats.com 09-06 e. IWS. Weidmann STULZ GmbH, Hamburg Technical data subject to changes without notice. STULZ the natural choice Close to you worldwide. with expert contacts in our STULZ subsidiaries, and our exclusive global network of sales and service partners. Our five production plants are in Europe, North America and Asia. www.stulz.com/global