New Deluxe Wall Mounted Heat Pump Series EXTERIOS



Similar documents
AIR CONDITIONING and HEAT PUMP PRODUCTS

AIR CONDITIONING and HEAT PUMP PRODUCTS

york air-conditioning products Residential & VRF News 2015

AIR CONDITIONING & HEAT PUMP PRODUCTS

Air Conditioning & Heat Pump Products

FTQ. Daikin Inverter Ducted Heat Pump

ECO-AIR AIR CONDITIONING

SANYO Air Conditioners & Heat Pumps

DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS

HIGH-EFFICIENCY DUCTLESS INDOOR COMFORT

FTXS. Wall Mount Heat Pump or Cooling Only

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

Air C r Conditioning & H g & Heat Pu at Pump Pro Produc u ts Revised Aug. 08

Heat Pump Product Brochure 2015/2016. Premier Series Hi-Wall Split Systems. Everyday Comfort

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

AIR CONDITIONING and HEAT PUMP PRODUCTS

m-series Ultimate comfort where it matters most Mseries.MrSlim.ca PRODUCT CATALOGUE

Submitted to Reference Approval Construction Unit Designation Schedule #

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle

Mini-Split Air Conditioners and Heat Pumps for Residential and Light Commercial Applications

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

FULL DC INVERTER SYSTEMS

2010 Duct-Free Splits Line Card

Contents. Part 1 General Information Part 2 Outdoor Units Part 3 Installation Part 4 Troubleshooting 73

1116, Suenaga, Takatsu-ku, Kawasaki , Japan

Cooling kw Heating kw

Air Conditioners Technical Data

26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.

HP switch LP switch Discharge thermo Comp. Surface thermo

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

DUCTED AIR CONDITIONING SOLUTIONS

Ductless Systemss A COMFORTABLE, CONVENIENT SOLUTION BUILT TO A HIGHER STANDARD. READ ONLY

USER S MANUAL HSC-24A

CAB LCAB HACAB RMP/AMP CC CY/YY RVP CUSTOM CU

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System

FHQ. Ceiling Suspended Heat Pump or Cooling Only

Inverter Air Conditioning for Light Commercial Use

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

Residential and Light Commercial Air Conditioning Systems

DESIGN & TECHNICAL MANUAL

NEW 3-PIPE ECOi MF2 SERIES

Samsung Room Air Conditioning

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Room Air Conditioner SVC MANUAL(Exploded View)

SiUS Service Manual. Inverter Pair FTXS-L Series FDXS-L Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

REMOTE CONTROL MANUAL

FCQ. Roundflow Cassette Heat Pump or Cooling Only

Unico Inverter. Unique and efficient.

SERVICE MANUAL MUZ-GE09NA MUZ-GE12NA MUZ-GE15NA MUZ-GE18NA MUZ-GE24NA MUY-GE09NA MUY-GE12NA MUY-GE15NA MUY-GE18NA MUY-GE24NA OUTDOOR UNIT

emura Form. redefined.

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

SiBE D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump

SiUS Service Manual. Inverter Pair Wall Mounted Type K-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

FBQ. DC Duct Heat Pump or Cooling Only

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

The Benefits Really Add Up

Hot Water. Heat pump water heaters. Residential and Commercial R410a

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Comfort... where you need it, when you need it. Ductless Mini-Split Systems

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

Energy Efficiency. Energy Efficient Home Cooling:

Ductless Heat Pumps. Gary Nordeen January

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

How To Make A High Efficiency Thermostat

PRODUCT CATALOG. Indoor Units

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

Appendix - Controllers 179

Ductless Mini-Split Systems. Comfort... where you need it, when you need it

14. Troubleshooting Guide

AIR-CONDITIONER SPLIT TYPE

Failure code manual. content

LG Duct-Free Split Systems Product Overview. LG comfort solutions that you never thought possible

More than Air Conditioning. Catalogue 2004/2005. Air Conditioning Program R 407C R 410A

Duct Free Split Air ConditionerS

air conditioners how to choose a cooling system

OWNER S MANUAL VMH 09/12/18/27/36 InverterFlex

Glossary of Heating, Ventilation and Air Conditioning Terms

-~ available. Power consumption during operation is substantially less than that of lower rated

innovative comfort solutions

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS

SERVICE MANUAL OUTDOOR UNIT MUZ-A09NA,- 1,- U1,- U2 MUZ-A12NA,- U1 MUZ-A15NA,- U1 MUZ-A17NA,- U1 MUY-A15NA MUY-A17NA MUY-A24NA,- 1,- U1,- U2

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

Residential and Light Commercial Air Conditioning Systems

All the best brands all under one roof

LG Electronics AE Company, Commercial Air Conditioning

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Air Conditioner CU-XE9PKUA CU-XE12PKUA CS-XE9PKUA CS-XE12PKUA. Destination U.S.A. Canada WARNING

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

DESIGN & TECHNICAL MANUAL

Trane Ductless Systems. Get comfortable with a smart solution. READ ONLY

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

Thru-the-wall AIR CONDITIONERS COOL ONLY HEAT PUMPS ELECTRIC HEAT

Operating Instructions Split System Air Conditioner

GREE, MAKING BETTER AIR CONDITIONERS

Transcription:

New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013

New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History Breakthrough technologies such as the inverter enable the highest energy efficiency* in the industry. Thanks to this exceptional performance, you enjoy even more comfort. EXTERIOS Indoor o Unit CS-XE9PKUA A/ CS-XE12PKUA Wireless Remote Controller 7

SEER 28.5 No.1 * High Energy Efficiency Breakthrough technologies, such as the inverter, enable the highest energy efficiency* in the industry. Thanks to this exceptional performance, you will enjoy even more comfort. *CS/CU-XE9PKUA as of March 2013 LOW AMBIENT OPERATION Powerful Heating at Low Ambient Operation Heating is still possible even if the temperature drops as low as 0 F for reliable heating in even the harshest winter. Inverter Technology Panasonic s inverter provides optimum power control and extremely efficient operation by changing the power supply frequency. The result is speedy, flexible operation using less electricity. Panasonic ductless split system designed to care for you With more than 50 years of experience of exporting to more than 125 countries around the world, Panasonic is unquestionably one of the leaders in the air conditioning business. With more than 200 million compressors produced, you are assured the high quality of Panasonic s air conditioners. 8

New added unique features Advanced Inverter Technology Less Energy and More Comfort The inverter constantly adjusts compressor rotation speed to provide optimum performance at all times. This extremely precise operation enables quick cooling or heating while reducing power consumption compared to conventional noninverter units. Reduces Electricity Consumption Panasonic Inverter air conditioners are designed to give you the exceptional energy savings performance while ensuring you stay comfortable at all times. Constant Comfort Precise temperature control with a wide power output range enables an inverter air conditioner to meet different room occupancy levels thus ensuring constant comfort. Quick Cooling (Heating) Panasonic Inverter air conditioners can operate with higher cooling power during the start up period to cool the room faster than non-inverter models. Inverter Indoor Quiet Operation Panasonic Inverter air conditioner s indoor operating noise has been reduced by 5dB as the Inverter constantly varies its output power to enable more precise temperature control. Even Wider Output Power Range Minimum capacity Rated capacity 2,800Btu/h 8,700Btu/h Maximum capacity 12,000Btu/h The Advantages of Inverter Control Comparing inverter and non-inverter air conditioners to cars The graph shows XE9PKUA s wide power output range during cooling. *Image of output power fluctuation Cooler Adjusts the accelerator and thus runs more economically. The accelerator can't be adjusted, so you spend a long time getting comfortable, then soon become uncomfortable. Room temperature Uncomfortable Comfortable Reaches the comfortable zone quickly. Keeps the temperature comfortable all the time. Setting Temperature Less Cool Uncomfortable START Runs at a fixed speed and takes longer to reach the comfort zone. The room gets too cold, then too warm. Inverter air conditioner Non-inverter air conditioner 9

ECONAVI with Intelligent Eco Sensors Panasonic has employed ECONAVI (Human Detection Technology) in its air conditioners. Since in 2007 and has perfected the feature since its launch. Panasonic is now introducing ECONAVI air conditioner to the US market. ECONAVI sensors moderate the temperature. This smart technology monitors and senses when there are people in the room and determines how much activity is occurring, then automatically adjusts the temperature setting accordingly for optimum operation. The area search mode uses sensors that can detect activity in the room and direct cooling to the occupied area. The low activity detection mode monitors the room, decreasing cooling when there is less movement, while the absence detection feature switches to a slightly less powerful cooling mode when there is no one in the room at all. Absence Detection ECONAVI detects human absence from the room and raises the target temperature. Area Search ECONAVI detects changes in human movements and direct the cooling to the occupied area to avoid the cooling in unoccupied area of the room. Activity Detection ECONAVI detects changes in activity levels and reduces the cooling power by adjusting set temperature. DETECT CONTROL DETECT CONTROL DETECT CONTROL No one is in the room. Detects absence. Gradually modulates cooling power by setting the new target temperature (set temp +4 F) Only one person in the room. Reduces the loss of cooling in the unoccupied area of the room. Level of activity is decreased. Detects low activity. Reduces cooling power by setting new target temperature (set temp +2 F) ECONAVI in cooling mode: *The target temperature set by ECONAVI will be restored automatically to the set temperature when the new condition is detected. Area Search Directs airflow to wherever you are in the room. Activity Detection Adjusts cooling and heating power to your activities. Absence Detection Reduces cooling and heating power when you are not in the room. Human Activity Sensor How Does ECONAVI Human Activity Work? Present Absent Enter Room Low activity High activity Normal activity Exit Room Out 1 2 3 4 5 +4 F Set Temperature 20min. +2 F 20min. +2 C +4 F -2 F -4 F 1 Hour -4 F Fan Speed Set Speed Set Speed Max Medium Fan Set Speed Legend: Set Temperature Cooling Power Heating Power Remark: Set temperature on remote control display remains unchanged. 10

Wall-Mounted Heat Pumps XE9PKUA / XE12PKUA EXTERIOS NEW Indoor Unit CS-XE9PKUA / CS-XE12PKUA Wall Mounted Heat Pumps Outdoor Unit CU-XE9PKUA / CU-XE12PKUA (optional) Wireless Remote Controller Wired Remote Controller (CZ-RD516C) (Optional) Wall Mounted Heat Pumps Model No. XE9PKUA XE12PKUA Unit Model No. Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit CS-XE9PKUA CU-XE9PKUA CS-XE12PKUA CU-XE12PKUA Performance & Electrical Ratings Capacity Cooling Btu/h 8,700(2,800~12,000) 11,500(2,800~14,000) Heating Btu/h 12,000(3,000~18,000) (10,600 at 17 F) 13,800(3,000~23,000) (13,500 at 17 F) Moisture Removal High Pints/H 1.3 2.3 Dry Air Flow High CFM 405 530 SEER Cooling 28.5 25.5 EER Cooling 16.1 14.35 HSPF Heating 12.5 12.0 Power Supply V, Phase, Hz 230/208V, 1PH, 60Hz 230/208V, 1PH, 60Hz Running Amps Cooling A 2.5/2.8 3.8/4.2 Heating A 4.0/4.5 5.2/5.8 Power Input Cooling W 540(150-850) 800(150-1,050) Heating W 860(150-1,650) 1,150(150-2,100) Back-up Heater kw --- --- Fuse or Circuit Breaker Capacity A 15 20 Features Controls Microprocessor Microprocessor Low Ambient Control Eqipped Equipped Wireless Remote Controller Included Included Wired Remote Controller (optional) CZ-RD516C CZ-RD516C Fan Speeds 5 Speeds + Auto 5 Speeds + Auto Timer 24hr Program 24hr Program Air Deflection Horizontal Manual Manual Vertical Automatic Automatic Air Filter Washable + Anti Microbial Filter Washable + Anti Microbial Filter Refrigerant R-410A R-410A Refrigerant control Electric Expansion Valve Electric Expansion Valve Operation Sound In(Hi / Lo/ Q-Lo) db-a 42 / 25 / 20 45 / 28 / 20 Outdoor(Hi) db-a 48 49 Refrigerant Piping Type Flare Flare Discharge inches 1/4 1/4 Suction inches 3/8 1/2 Refrigerant Pipe Length Ft. Max. 66 Max. 66 Elevation Difference* Outdoor Above Ft. Max. 49 Max. 49 Outdoor Below Ft. Max. 49 Max. 49 Dimensions & Weight Indoor Unit Outdoor Unit Indoor Unit Outdoor Unit Height inches 11-5/8 27-3/8 11-5/8 27-3/8 Width inches 34-9/32 34-15/32 34-9/32 34-15/32 Depth inches 10-1/16 12-5/8 10-1/16 12-5/8 Net Weight Lbs. 24 97 24 97 * This is maximum elevation difference when the indoor unit is located above the outdoor unit. (Refer to the table on the P.34 in the catalog for more detail.) 11 ECONAVI Room Freeze Protection Wireless Control Wired Control Self Diagnose Dry 5 Fan speeds Air Sweep Louver Microprocessor Control Autochange over Night setback Hot Start 24hr timer