Measurement by Ion Selective Electrodes



Similar documents
Ion Selective Electrodes

Nitrogen, Ammonia. Known Addition ISE Method 1 Method Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table

Direct ISE Method Method to 1000 mg/l Na + Sodium ISE

ph Measurement and Control

DISSOLVED OXYGEN PROBE

Milwaukee USER MANUAL

Professional Plus. Calibration Tips

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

User Guide Dissolved Oxygen Probes

Common Problems with Online Water Quality Analyzers. Greg Macy Director AquatiPro LLC

SenTix 950 SenTix 980

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

ph Measurements of Common Substances

Appendix D lists the Field Services Standard Operating Procedures. Appendix E lists the Biological Monitoring Standard Operating Procedures.

USEPA Electrode Method Method 8156

Direct Measurement Method Method to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor

MODEL 970 DISSOLVED OXYGEN METER OPERATING MANUAL

Experiment 4 (Future - Lab needs an unknown)

DR/4000 PROCEDURE. CHLORINE, Free

Standard methods in water analysis

Handbook. Thermo Scientific. ph Electrode Selection Handbook

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

LACHAT METHOD NUMBER D Rev 1, 21 March 2011 SCOPE AND APPLICATION Approximately g CN/L g CN/L. 09e

CONDUCTIVITY SENSOR. Description D0382. Figure 1. The Conductivity Sensor

Measuring the Conductivity of Pure Water Using USP<645>

Determination of sodium with the ion-selective

Texas Commission on Environmental Quality

A Potentiometric Analysis of Fluoride Ion in Toothpaste

Measuring ph in Water or CaCl2 Using a ph Meter. Compiled by Darren Murray, June 30, 2011 TABLE OF CONTENTS OVERVIEW 3

Ion-selective Measurements

9. Analysis of an Acid-Base Titration Curve: The Gran Plot

Figure 1. A voltaic cell Cu,Cu 2+ Ag +, Ag. gas is, by convention, assigned a reduction potential of 0.00 V.

ELECTROCHEMISTRY. Theory and Practice

Standard Operating Procedure for Total Kjeldahl Nitrogen (Lachat Method)

USEPA 1 FerroVer Method 2 Method to 3.00 mg/l Fe Powder Pillows or AccuVac Ampuls

6 H2O + 6 CO 2 (g) + energy

Neutralizing an Acid and a Base

Chlorine, Total. DPD Method 1 Method to 5.00 mg/l Cl 2 Test 'N Tube Vials. Test preparation. Instrument-specific information

Care, Maintenance, and Storage of YSI 6-Series Probes and Sondes

4.0 EXPERIMENT ON DETERMINATION OF CHLORIDES

OxyGuard. Dissolved Oxygen Probe

5.0 EXPERIMENT ON DETERMINATION OF TOTAL HARDNESS

PN /rev. D December Theory and Practice of ph Measurement

Customer application report

PROCEDURE COVERSHEET. Document Section: CHEMISTRY Author: JOANNE WONG Date Authored: JAN In Use Date: 2/1/2011 Discontinued Date:

Name: Class: Date: 2 4 (aq)

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

LZV585 (B) The 1-cm path is aligned with the arrow on the adapter

Gel-filled ph Electrode

Method 8155 NITROGEN, AMMONIA (0 to 0.50 mg/l NH 3 -N) For water, wastewater, seawater

Experiment 8 - Double Displacement Reactions

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Instruction Manual HI Portable Waterproof Microprocessor Dissolved Oxygen Meter

TITRATION CURVES, INDICATORS, AND ACID DISSOCIATION CONSTANTS

Information on measuring ammonia in water. Dr. Jürgen Schleicher

Determination of calcium by Standardized EDTA Solution

DISSOLVED OXYGEN METER Model : DO-5509

Electrochemistry Revised 04/29/15

High Purity Water Resistivity/ Conductivity Measurement

Dissolved Oxygen Probe (Order Code DO-BTA or DO-DIN)

Care and use guide. Contents. a handy solution made easy. page

FerroVer Method 1 Method to 3.0, 1.0 to 30.0 and 10.0 to mg/l Fe Powder Pillows

Features, Limitations & Potential Errors

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

Winemaker s Guide to Chemistry Analysis

Halogen Free: What, Why and How. Presented by : Jim Cronin Environmental Monitoring and Technologies, Inc.

The Theory of ph Measurement

Operator Quick Guide EC SENSOR

Introduction. The following definitions may help you better understand the components of the data report.

Precipitation Titration: Determination of Chloride by the Mohr Method by Dr. Deniz Korkmaz

Decomposition. Composition

Phosphorus, Reactive (Orthophosphate)

Chemistry 119: Experiment 7. Potentiometric Titration of Ascorbic Acid in Vitamin C Tablets

Global Water Instrumentation, Inc.

W1 WORKSHOP ON STOICHIOMETRY

XI. Methods of Analysis DETERMINATION OF POTASSIUM CARBONATE CALCULATIONS REAGENTS PROCEDURE

Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater

Removing Heavy Metals from Wastewater

Determiniation of Flouride Ion in Well Waters of Eastwood School District, Wood, County, Ohio

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

Thermo Scientific Orion AQUAfast Powder and Tablet Reagent Chemistry User Guide

Chapter 16: Tests for ions and gases

Eutech 2700 Series. Bench Meters. ph ORP ION Conductivity TDS Salinity Resistivity Dissolved Oxygen Temperature

AIRMoN, ph and Conductivity Field Measurement

1.4 This method is capable of measuring DO in the range of 0.20 to 20 mg/l.

Experiment 18: ph Measurements of Common Substances. Experiment 17: Reactions of Acids with Common Substances

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline

To determine the equivalence points of two titrations from plots of ph versus ml of titrant added.

IB Chemistry. DP Chemistry Review

ATOMS. Multiple Choice Questions

How To Remove Ammonium From Water

hij GCSE Additional Science Chemistry 2 Higher Tier Chemistry 2H SPECIMEN MARK SCHEME Version 1.0

ph Alkalinity of Water

Electrical Conductivity of Aqueous Solutions

User Guide. RDO Optical Dissolved Oxygen Sensor

Chloride and Salinity

CALIFORNIA DEPARTMENT OF PUBLIC HEALTH ENVIRONMENTAL LABORATORY ACCREDITATION PROGRAM Accredited Fields of Testing

SINGLE RANGE DS METERS Operation Instructions

Total Suspended Solids Total Dissolved Solids Hardness

Acid Dissociation Constants and the Titration of a Weak Acid

Transcription:

Measurement by Ion Selective Electrodes Adrian Vazquez May 8, 2012 Why Use Ion Selective Electrodes? Responsive over a wide concentration range Not affected by color or turbidity of sample Rugged and durable Rapid response time Real time measurements Low cost to purchase and operate Easy to use 2 1

Why Use ISE s? There are many types of ISE applications: Ammonia in water or wastewater Residual chlorine in water or wastewater Chloride in water or wastewater Cyanide in water or wastewater Fluoride in drinking water Nitrate in drinking water or wastewater 3 Why Use ISE s? EPA approved methods Acidity Alkalinity Ammonia Bromide Chloride Residual Chlorine Cyanide Fluoride Total Kjeldahl Nitrogen (TKN) Nitrate Dissolved Oxygen/BOD ph Sulfide 4 2

What Are ISE s? Electrodes are devices which detect species in solutions Electrodes consist of a sensing membrane in a rugged, inert body 5 How Do ISE s Work? If two solutions are separated by an ion-permeable membrane, they will equilibrate: 6 3

How Do ISE s Work? If the membrane is permeable to only one species, a charge quickly develops which opposes further movement The charge is proportional to the difference in concentration on the two sides The total number of ions that diffuse is very small 7 How Do ISE s Work? The reference electrode completes the circuit to the sensing electrode (ISE) Reference electrodes have a small leak to establish contact with the sample The reference solution (usually KCl) in contact with the reference keeps the reference potential constant 8 4

The Electrode Measurement System The meter measures the voltage potential (mv) difference between the sensing electrode and the reference electrode. Sensing electrode potential changes with sample concentration. Temp Probe Reference Half-Cell Meter/Amplifier Sensing Half-Cell Reference electrode potential does not change to compare sensing potential to. Current Flow 9 ISE Meters ISE meters report concentrations No manual calibration curves are required The potentials of known standards are stored in memory to produce a calibration curve The potential of the sample is then compared to the calibration curve to determine the concentration ISE meters generate sophisticated curves which are held in the meter s memory Run standards Run unknowns Read results 10 5

Types Of Sensing Electrodes Glass Membrane Solid State Liquid Membrane Gas Sensing 11 Glass Membrane Electrodes ph Sodium 12 6

Glass Membrane Electrodes Example: Sodium 0.02 detection limit Available in combination or half-cell versions Ross or Ag/AgCl references 13 Types Of Sensing Electrodes Solid State 14 7

Solid State Electrodes Bromide Cadmium Chloride Chlorine Copper Cyanide Fluoride Iodide Lead ph Silver Thiocyanate 15 Solid State Electrodes Sensing element is a solid crystalline material Store combination electrodes in dilute standard Store half-cell electrodes dry Polish solid state electrodes to rejuvenate 16 8

Solid State Electrodes Example: Chlorine EPA approved for drinking water or wastewater 0.01 detection limit Combination electrode 17 Types Of Sensing Electrodes Liquid Membrane 18 9

Liquid Membrane Electrodes Ammonium Calcium Chloride Fluoroborate Nitrate Perchlorate ph Potassium Surfactant 19 Liquid Membrane Electrodes Sensing membrane is an ion carrier dissolved in a soft plastic Store electrodes in dilute standard for short-term Store module dry in vial for long-term 20 10

Liquid Membrane Electrodes Example: Nitrate EPA approved for drinking water 0.1 ppm detection limit Available in combination or half-cell versions 21 Gas Sensing Electrodes Ammonia Carbon dioxide Nitrogen dioxide Oxygen 22 11

Gas Sensing Electrodes: Ammonia Gas sensing electrodes work by measuring the ph change caused by diffusion of the gas through a hydrophobic but porous membrane Ag/AgCl electrodes Internal filling solution Outer body Filling solution (NH 4 Cl, ph ~5) ph Sensing Glass Junction Gas Permeable Membrane NH 3 diffusion Thin response layer of electrolyte (ph increased) NH 3 + H 2 O NH + 4 + OH - 23 Ammonia ISE Measurement Measure from 0.01 ppm to 17,000 ppm ammonia Also use for ammonium and organic nitrogen Must adjust sample ph ph electrode Measures change in ph across the membrane EPA approved method for waste water Must pay attention to manufacturer s instructions 24 12

Ammonia Electrode Setup Glass sensing surface protruded relatively to the outer body (view without gas membrane) Membrane on outer body without the inner sensing stem (retaining cap not shown) Membrane on outer body with the inner sensing stem protruded (retaining cap not shown) 25 Ammonia Tips Tilt the electrode in sample or standard Rinse probe by immersion More effective than squirting with rinse bottle Does not disturb layer of inner fill solution between membrane and inner stem Conditioning electrode. Exposure to ammonia prior to calibration/use greatly improves performance 15 minutes in 1mg/L standard (with ISA) greatly improves performance 26 13

Ammonia Tips Electrode Assembly Get rid of air bubbles by tapping on electrode body. Pull gently on cable or move sensor up and down Rinsing Electrode Rinse generously between measurements, blot dry. Immerse rather than squirt. Position Electrode at Slant This will make easier to view and dislodge bubbles Inspect Membrane Surface Remove any bubbles from surface of membrane by wiggling or tapping electrode Electrode Storage If storing the electrode overnight or up to 1 week, store in the electrode fill solution Stirring Stir vigorously but avoid creating bubbles 27 Classic Ammonia ISE Assembly Soak inner body in fill solution for 2 hrs. Replace the membrane every 2-4 weeks Use tweezers to handle membrane Stretch membrane until taut Use 2.0-2.5 mls of fill solution Shake electrode down after assembly Pull on the electrode cable to allow fresh supply of fill solution to the membrane but re-calibrate after this is done 28 14

Classic Ammonia ISE Storage 9512BNWP Only Store in 10-100 ppm ammonia standard Between measurements store In 10 ppm standard with NaOH (ISA) Condition electrode in ph 4 buffer for several minutes before starting low level calibration 29 High Performance Ammonia ISE Hints Membranes and fill solution are NOT interchangeable between old and new electrodes! Do not stretch new membrane Just smooth over and pull tight Can use outer bodies with assembled membranes Fill electrode to just below fill level line Condition assembled electrode overnight in electrode fill solution Store the electrode in electrode fill solution or storage solution (951213) Between measurements use 1 ppm standard with 1 ml alkaline reagent Use Low Level Ammonia ISA (951210). Do not use standard ISA (951211) for any calibrations or measurements below 10 ppm Or use 1 ml of alkaline reagent (951011) per 100 mls sample or standard Do not reuse fill solution 30 15

Ammonia Trouble Shooting Tips Make sure you have fresh standards and are using the correct amount of ISA Verify the electrode been conditioned Check slope and drift of electrode If you have a poor slope or drift, change the membrane and fill solution. Recheck slope and drift Check electrode inner body. Gently handle inner body Stir vigorously but without creating bubbles 31 How Are ISE s Used? Direct measurement Incremental methods Titrations Gran methods 32 16

Direct Measurement Preferred method in most cases: Many samples with similar backgrounds High volume of samples Wide range of concentrations Easy Calibrate by comparison with known standards Read by preparing calibration curve or using ISE meter Precision is +/- 2% 33 Direct Measurement Calibrate every 2 hours Always calibrate with standards that bracket expected concentration range Always use at least two standards that are ten fold apart in concentration Slope range for monovalent ions: 54-60 mv Slope range for divalent ions: 26-30 mv 34 17

Direct Measurement Two-point calibration for linear portion of curve Low-level measurements require non-linear multi-point calibration or blank correction Use a meter which calculates the blank from the calibration curve No separate blank has to be run Equivalent to drawing a smooth curve through the lowest three calibration points and extrapolating to zero concentration 35 How Meters Calibrate Slope Slope Segmented Point-to-point calibration Auto-Blank for Low Levels Smooth curve through points 36 18

Incremental Methods Known addition Analate addition Known subtraction Analate subtraction 37 Known Addition A technique which adds a known amount of the species being measured into the sample This incremental method eliminates the need for a separate calibration curve for each sample Single, double, or multiple known additions possible 2-4 times more accurate than direct read 38 19

Known Addition Known addition is preferred when: Number of samples is small Backgrounds vary and cannot be fixed Working at very low levels Excess complexing agent is present 39 Practical Considerations Method interferences Electrode interferences Temperature effects 40 20

Method Interferences Many method interferences can be overcome by using Ionic Strength Adjusters ISA s are added to samples and standards to maintain constant background ISA s minimize ionic strength differences ISA s can complex interferences Example Fluoride may be complexed by aluminum ISA s can adjust ph to proper range 41 Temperature Effects A change in temperature will cause electrode response to shift and change slope On average, a 1 o C change in temperature gives rise to a 2% error for monovalent ISE s On average, a 1 o C change in temperature gives rise to a 4% error for divalent ISE s Temp ( 0 C) Slope (mv) 0 54.2 10 56.2 20 58.2 25 59.2 30 60.2 35 61.2 40 62.1 50 64.1 42 21

Temperature Effects Temperature compensation is possible only if the isopotential point of the electrode is used to adjust the calibration curve For most situations make sure standards and samples are at the same temperature 43 Troubleshooting Sequence Meter Standards Reference electrode Sensing electrode Sample Technique 44 22

Troubleshooting ph Problems Troubleshooting ISE Meters Use meter shorting strap Reading should be 0 mv +/- 0.2 mv Use meter self-test procedure Troubleshooting Standards Use Fresh Standards for calibration Verify expiration date Verify when standard was opened Stir standards during calibration 45 Making Accurate Measurements Maintain a constant reference potential Adjust ionic strength Remove method interferences Remove electrode interferences Operate at a constant temperature Stir standards and samples gently Bracket sample with standards 46 23

Thermo Scientific Contact us for any technical questions Technical Service: (800) 225-1480 Web site: www.thermoscientific.com/water 47 Q&A 48 24