Product description NCC Data Center



Similar documents
World s Greenest High Performance Data Center

Data Centre Stockholm II, Sweden Flexible, advanced and efficient by design.

Facility Summary. Facility Condition Summary. Seattle School District David T. Denny International Infrastructure. Facility Components

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

SAMPLE SCHEDULE OF VALUES APPLICATION & CERTIFICATE FOR PAYMENT

Occupancy: Assembly (A-3) and Business -Includes offices, seminar rooms, classrooms, and café facility. Duke University Medical School

NORTHERN VIRGINIA ONE (NoVa) DATA CENTER OVERVIEW

50 St Mary Axe London EC3

PROJECT COST ESTIMATES & FEASIBILITIES

EXAMPLE OF A DATA CENTRE BUILD

100 Locust Avenue, Berkeley Heights, New Jersey P R O P E R T Y O F F E R I N G

Technical specifications. Containerized data centre NTR CDC 40f+

Hamilton-Wentworth Catholic District School Board Event Listing By Ascending Event Year

LITITZ MUTUAL INSURANCE COMPANY 2 North Broad Street Lititz, Pennsylvania - MAIN OFFICE -

Green House, Hungary

Datacentre Studley. Dedicated managed environment for mission critical services. Six Degrees Group

So you want to build a data centre? Look what s coming from BICSI! Matt Flowerday Capitoline FZC mflowerday@capitoline.org

Data Centre Testing and Commissioning

ModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape

Park View Place. Compass. House. Royal Wharf Gardens Endeavour. House. Thameside. Sienna. House. House. Apartments Townhouses.

Saint Cloud Business Center

Cannon T4 Modular Data Centres. For Outside Deployment & Challenging Environments

Commercial Building Valuation Report

IBM Twin Data Center Complex Ehningen Peter John IBM BS 2011 IBM Corporation

Reference: BRM A0 July 18 th, Cursory Visual Review of Various Below Grade Spaces and Exposed Foundation Walls

Executive Flight Office & Hangar

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

KIEWIT CM/GC Enabling/Utilities

48. AQUARIUM. Aquarium. Classification: Cluster: Location: Close to junction of Inselrhue and Loiter Way, Belle Isle. Total Area: No.

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION

FLORIDA STATE UNIVERSITY INTERNATIONAL PROGRAMS VALENCIA "GOLD" STUDY CENTER

Biznet Technovillage Data Center

Rockwool Flexi Insulation Application Guide

MEMORANDUM. General: Foundation:

Specialty Environment Design Mission Critical Facilities

This 5 days training Course focuses on Best Practice Data Centre Design, Operation and Management leading to BICSI credits.

All Weather Hall. Efficient, multipurpose & quick to build

TechPractices: Home Front Homes:

SUBSTANTIAL IMPROVEMENT OR SUBSTANTIAL DAMAGE NOTICE TO PROPERTY OWNER

COMMERCIAL PLAN SUBMISSION FOR NEW CONSTRUCTION AND/OR RENOVATIONS

SPACE TYPE: AUTOMATED DATA PROCESSING CENTER (ADP) (MAINFRAME)

Building Condition Assessment Report

Data Centre Harbour Exchange Square Campus, London Access to unrivalled connectivity.

University of St Andrews. Energy Efficient Data Centre Cooling

Commercial Building Valuation Report

BPC Green Builders. Green building for new and existing homes. Health Comfort Energy

Containment Solutions

BUILDING SAFETY UNIT

Data Centre Basiglio, Milan Flexible, advanced and efficient by design.

Notice to Property Owners

Seattle Public Schools Building Excellence IV Projects Under Construction

Tour of new eircom Data Centre Blanchardstown by Dervan Engineering Consultants 11 th March 2015

AT&T Internet Data Center Site Specification - Phoenix Area (Mesa, AZ)

Our data centres have been awarded with ISO 27001:2005 standard for security management and ISO 9001:2008 standard for business quality management.

CHARLOTTE COUNTY Community Development Department

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Recommendations for Measuring and Reporting Overall Data Center Efficiency

hong kong//china data center specifications tel: fax: internet + intellectual property + intelligence

Building Condition Assessment Report

FOR RENT PRODUCTION AND COMMERCIAL FACILITIES ALONG WITH A SOCIAL AND OFFICE SURFACE MARR BUSINESS PARK 10 NAD DRWINĄ STREET IN KRAKÓW

Town of Sandwich Facilities Department Summary of Building Repairs from Prior 5 7 Years List Updated August 7, 2015

PLEASE REFER TO YOUR INDIVIDUAL QUOTE

Hunter College school of Social Work Thesis Proposal

DATACENTER Vienna 1. Scalable, Safe and Innovative

TAX APPRAISAL DISTRICT OF BELL COUNTY STORES & COMMERCIAL IMPROVEMENT CLASSIFICATION GUIDE

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

EMC DURHAM CLOUD DATA CENTER

NetXtend Flex Series Integrated Outdoor Enclosure Solution. Outside Plant for Business-Critical Continuity

School Construction Authority Architecture & Engineering

We care about. Environmentally-Friendly Building Products from Renewable Resources. natural building products. Product range overview

Think Of Us First! When It s Time to Distribute Your Plans

N O W A V A I L A B L E

Datacentre London 1. Dedicated managed environment for mission critical services. Six Degrees Group

ALWAYS ON GLOBALSWITCH.COM

Optimum Climate Control For Datacenter - Case Study. T. Prabu March 17 th 2009

INDUSTRIALS COLD STORAGE FACILITIES

Integrated Solar Radiant Systems

Data Center Industry Leaders Reach Agreement on Guiding Principles for Energy Efficiency Metrics

Cody Park One of Ark s high integrity data centre campus sites

APC APPLICATION NOTE #92

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Dow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems

Global Data Center & Colocation Facilities

Building Code Clarifications - 7. Fire Resistance

DRAPER ELEMENTARY SCHOOL

As close to perfection. development and production. Modular data center

ORANGE UNIFIED SCHOOL DISTRICT SCHOOL FACILITIES MASTER PLAN NEEDS ASSESSMENT

Pre-Drywall Inspection Report

Datacentre South London Data sheet

SCHEMATIC AND PROJECT BUDGET APPROVAL EAST CAMPUS NURSING EDUCATION AND CLASSROOM

Recommendations for Measuring and Reporting Overall Data Center Efficiency

LEED PRESENTATION OUTLINE

Cooling a hot issue? MINKELS COLD CORRIDOR TM SOLUTION

Building Permits: When are they required?

Composite Panel Firewall Systems

Verizon SMARTS Data Center Design Phase 1 Conceptual Study Report Ms. Leah Zabarenko Verizon Business 2606A Carsins Run Road Aberdeen, MD 21001

Transcription:

Product description NCC Data Center

Concept General As one of the largest actors in the Nordic construction industry, NCC Construction plays a leading role in shaping the future of our society. After building one of Europe s largest data centers, Facebook in Luleå, we are now preparing ourselves and the market for the rapidly growing demand for data storage. Part of this work has been to design a concept for a multipurpose data center that will shorten lead times in the development of new projects. This concept can be used both when NCC Construction acts as the developer of a facility as well as when NCC Construction acts as contractor only. The concept is the result of a co-operation between NCC Construction and Data Center specialists Enaco. It uses best practices from both small and large data centers with robust and efficient technical solutions that will work throughout the Nordic region. Concept The triple focus for the concept NCC Data Center is energy usage efficiency, flexibility and reliability. Energy usage efficiency The concept is designed for a PUE level below 1.15. The concept is designed for waste heat, e.g. to district heating systems. It will be possible to use self-produced power, e.g. solar panels or wind power. The concept will be certified in accordance with LEED or BREEAM depending on location and customer requirements. Flexibility The concept is flexible in size, a pay as you grow principle. Raised floor in the data hall. Cooling system with liquid coolant gives flexibility in both layout and waste heat. It can easily be divided for different users with different needs. Reliability A well-integrated design based on best practices and local conditions Locating a Data Center in Sweden offers many advantages: Sweden is ranked as number three, after US and UK, in The Data Centre Risk Index 2013. Europe s lowest electricity prices Stable and green grid Stable political and economic conditions Cool climate perfect for Data Centers Well-functioning building process NCC Construction has been in operation for more than one hundred years. 1

Location Location NCC can offer our Data Center concept to several locations in Sweden. The Stockholm area is, understandably, a very attractive location. There are also a number of sites in the northern part of Sweden that have been thoroughly investigated and prepared for new Data Center locations on behalf of Business Sweden and its local member organizations. The sites are ready-to-build and they meet the high demands for access to renewable power and high connectivity. Suitable areas for location of NCC Data Center in Sweden NCC Data Center HH2 HH1 Greenfield 2 Hydro power plant ready-to-built site Example of ready-to-build site 2

Property NCC Data Center NCC Data Center main entrance 3 Deliveries

Facts NCC Data Center Two floor DC on total 20,000 m2, scalable from 5,100 m2 and up. Fully developed 10,200 m2 data floor, scalable from 2,500 m2 and up. Scalable from 2 to 16 MW of critical power Scalable from 612 to 4896 racks, height 42 unit, size 600 x 1200 mm PUE level <1,15 Redundancy level N+1 10 month construction time LEED certified Exterior Substructure Footings and slab on grade. Superstructure Steel beams and columns. Precast concrete deck. Exterior walls, ground floor Precast concrete sandwich panels. 120 mm insulated metal panel walls at generator building. Roof Waterproof membrane. Fire protection According to the Swedish regulations. 4

Building Interior Ceiling, ground floor Concrete. Sound insulation in s with a high noise level. Acoustical ceiling tiles in offices etc. Walls, ground floor Painted plasterboard on steel studs, fire and sound rated as required. Concrete firewalls. Concrete walls around stairwell and elevator. Floor finishes, ground floor Linoleum carpets in offices etc. Ceramic tiles in toilets and shower s etc. Surface treated concrete in storage s and technical s. Access floors in electrical s. Floor finishes, 1st floor Walls, 1st floor Surface treated and sealed concrete. Access floors on precast concrete slab. Firewalls of Insulated metal panels. Concrete walls around stairwell and elevator. Installations Heating Air treatment Cooling Lighting Fire alarm Fire suppression system Security system Power Backup power UPS Internal waste heat from data center. to local heating distribution systems. Traditional HVAC system with heat Cooling system with liquid coolant and free cooling function. Hot aisle containment with in-row cooling. LED lighting and option optic daylight system Traditional smoke/heat detectors with early detection system in the server halls connected to the fire brigade. Flexible to customer demands. Flexible to customer demands. Scalable from 2 to 8 2000 MVA transformers. Primary voltage 20 kv, secondary voltage 400 V 50Hz. Scalable from 3 to 12 generator sets, 3000 kva Scalable from 2 to 8, 2000 kw Options Wind power NCC is one of the larger operators in ongoing wind energy development in Scandinavia. If you need a data center with an innovative, renewable energy profile, or if you need to secure a competitive electricity price, then NCC, with its cluster of companies, is the right partner for you. Wind power 5

Ground floor, technical and staff areas Foam Diesel Tanks Foam Diesel Tanks Foam Diesel Tanks Foam Diesel Tanks Com Com Com Com Com Com Com Com Com Com Com Com Com Com Com Office Reception Fire suppression Control Stairs First floor, ser ver halls Hot aisle containment Server hall D1 D Server racks CS In-row cooler 1:200 SERVER HALL FÖRHANDSKOPIA PLAN 2 DEL D1 2015-01-19 More detailed drawings can be found at www.ncc.se/en/products-and-services/ncc-data-center/ 6

Contact person: Ola Daleke ola.daleke@ncc.se +46 8 585 516 97 Johan Gustafsson johan.gustafsson@ncc.se +46 920 73464 www.ncc.se January 2015, with reservation for printing errors and changes such as material, color, etc. For more information, please contact NCC.