Datasheet Overview The EC-Net AX building management system (BMS) is a comprehensive Web-based platform powered by the Niagara AX Framework. Its open structure creates a common development and management environment for the integration of BACnet, LONWORKS, Modbus, and other standards. is a fl exible network server used in applications where multiple Niagara AX - based EC-BOS AX stations or multiple IP and Wi-Fi product series are networked together. A graphical user interface provides traditional building management functions such as scheduling, trending, alarming, historical data collection and advanced energy management applications. Applications Integrate a variety of devices and protocols into a common distributed automation system Create a network environment with comprehensive database management, alarm management and messaging services Features & Benefits Graphical Engineering Toolset provides a comprehensive, graphical toolset that enables users to build rich applications in a drag-and-drop environment. By wiring components together, developers build control strategies, alarming and scheduling applications as well as browser-based displays and reports. Database Drivers Optional SQL and Oracle drivers enable seamless data transfer to these industry standard databases. Reduced Development Time Reduces development time by merging automation, IT and Internet technologies in a single solution. With an EC-BOS AX, advanced webservices applications, such as BACnet/IP, TCP/ IP, HTTP, XML, SOAP, and obix, can be implemented so that you can read data, send commands, and respond to alarms in real-time from anywhere using any standard web browser.
Multi-protocol, Multi-Vendor Connects to almost any embedded device, regardless of manufacturer or communication protocol, as a result of the common environment created by Niagara AX s open Java-based Framework. Integrates geographically dispersed, multi-vendor devices into an interoperable application to save time and money. Model Selection Versions is available in the following capacity range. Software maintenance is required when purchasing software see the following page. 0 1 2 3 10 100 UNL Demo with 0 Niagara network connections - for managing IP devices only. Includes standard drivers. Software Maintenance Agreement (SMA) must be purchased in conjunction with Supervisor software. with 1 Niagara network connection. Includes standard drivers. Software Maintenance Agreement (SMA) must be purchased in conjunction with Supervisor software. with 2 Niagara network connections. Includes standard drivers. Software Maintenance Agreement (SMA) must be purchased in conjunction with Supervisor software. with 3 Niagara network connections. Includes standard drivers. Software Maintenance Agreement (SMA) must be purchased in conjunction with Supervisor software. with 10 Niagara network connections. Includes standard drivers. Software Maintenance Agreement (SMA) must be purchased in conjunction with Supervisor software. with 100 Niagara network connections. Includes standard drivers. Software Maintenance Agreement (SMA) must be purchased in conjunction with Supervisor software. with Unlimited Niagara network connections. Includes standard drivers. Software Maintenance Agreement (SMA) must be purchased in conjunction with Supervisor software. Additional licence of Demo. Includes all standard drivers and EC-Net AX Pro. Purchase this version for internal use, ex. technician's laptops. 2/6
Initial Maintenance Plan Software maintenance is required when purchasing software. The minimum initial software maintenance plan is 18 months. Optional 3 or 5 year maintenance may be substituted. These software maintenance plans are ordered separately according to the version chosen. See the price list for more details. Maintenance Plan Renewal If Maintenance coverage is not purchased for any period, the price of Maintenance for the next period for which it is purchased will be (a) the Maintenance fee for the period(s) for which Maintenance was not purchased, up to a maximum of 5 years; and (b) the Maintenance fee for the next year. These software maintenance plan renewals are ordered separately according to the version. See the price list for more details. Core Capacity Upgrades Core upgrades add extra Niagara connection capacity to the software. The following options are available. Niagara Connection Adder Adds one additional Niagara connection to. 100 Upgrade UNL Upgrade Upgrades "small" ( 0 through 10) to 100 Niagara connections. Will maintain any Niagara Connection Adder that were added to original license. Upgrades 100 to unlimited Niagara connections. Database Drivers Many open protocol IP drivers are included with. However, the following database drivers must be purchased separately if required. EC-DR-S-DB-MYSQL EC-DR-S-DB-ORCL EC-DR-S-DB-SQL EC-DR-S-DB-CSV MYSQL Database driver. Oracle 11G Database driver. SQL Database driver. CSV Database driver. 3/6
Device Integration Packs Device Integration Packs add extra device connection capacity to the software. The following options are available. 10 25 50 100 200 Supports up to 10 devices or 500 points (Standard drivers included). Supports up to 25 devices or 1,250 points (Standard drivers included). Supports up to 50 devices or 2,500 points (Standard drivers included). Supports up to 100 devices or 5,000 points (Standard drivers included). Supports up to 200 devices or 10,000 points (Standard drivers included). Platform Requirements Processor Intel Pentium IV, 2 GHz or higher, Core 2 Duo also acceptable Operating System Microsoft Windows XP Professional, Windows 2003 or 2008 Server (if Microsoft IIS is disabled), Vista Business, or Windows 7, 8.1 & Server 2012 Mozilla Firefox or Internet Explorer 5.0 or later For the 64 bit, the required OS is Windows XP Professional-64 bit or Windows 7 64-bit Memory 1 GB minimum, 2GB or more recommended for large systems, 8 GB or more recommended for the Windows 64 bit version Hard Drive 1 GB minimum, 5 GB for applications that need more archiving capacity Display Video card and monitor capable of displaying 1024 x 768 pixel resolution or greater Hardware As required by the operating system Network Support Ethernet adapter (10/100MB with RJ-45 connector) Network Connection Full time high-speed ISP connection recommended for remote site access (i.e. T1, ADSL, cable modem); 56KB modem minimum Minimum Requirements 1 : EC-Net AX version 3.8 and higher EC-BOS AX version 3.6.406, 3.7.108, 3.8.38 and higher 1. If you require EC-Net ax supervisor for version 3.7 or earlier, then you need to order a legacy version of. 4/6
System Architecture Unified Building Management System Visualization, Enterprise Software & Apps ENVYSION EC-Net AX EnerVue EC-Net AX Security Mobile Apps - Native Network Management, Archiving, & Global Funtions Internet Ethernet, TCP/IP, BACnet/IP, XML, HTTP, obix, FOX, Web Services Local Applications Integration, Multiprotocol / Multi-location & Data Normalization Wi-Fi Hotspot EC-BOSAX EC-gfxProgram mydc Control mydc AirBalancing System & Equipment - Controls & Display - HVAC & Lighting System Controller HORYZON ECx-400 System Controller ECB-650 M-BUS Gateway ECL-650 EC-BOSAX Security Remote I/O EC-BOSAX Remote Reader ECx-420 EC-Light Wi-Fi Adapter Wi-Fi ECB-400 ECL-410 Wi-Fi Adapter ECB-203 VAV Controller Room Controls - HVAC & Lighting - Sunblind / Shade VAV Controller Room Devices and Field Devices ECB-PTU ECB-VAV ECx-Light VAV Controller Wireless Adapter Open-to-Wireless ECx-Light ECB-300 ECL-253 ECB-VAV ECL-VAV ECB-PTU ECL-PTU ECx-Light ECx-Light Room Devices Card Key CTR-DALI MS2 & EC-Remote RFR EnOcean Light Switch EC-Multi-Sensor & EC-Remote EC-Smart-Vue Field Devices RCL-Light EC-Smart-Comfort Smart-Light Smart-Blind EC-Smart-Air ECW-Sensor Variable Frequency Drive Variable Frequency Drive Energy/Flow Meter Flow Sensor DALI Fixture 1 Heat Meter DALI Fixture 2 Variable Frequency Drive Heat Meter Energy Meter BACnet MS/TP Energy Meter Energy Meter EnOcean BACnet IP Subnet Modbus RTU Energy/Flow Meter BACnet MS/TP HVAC, Smart Room Control, Custom Applications and Energy Metering Reader Relay LONWORKS TP/FT Subnet Keypad M-Bus LONWORKS TP/FT Wiegand DALI Lighting and Sunblind Control Access Control Distech Controls offers an extensive range of best-of-breed, performance-proven field devices that complement our building automation offering. This comprehensive line of field devices - including a variety of Distech Controls labelled products - offers a complete, cost effective solution, from design to installation., Distech Controls, 2015, all rights reserved. Distech Controls, the Distech Controls logo, Innovative Solutions for Greener Buildings,, EC-NetAX are trademarks of Distech Controls Inc. LONWORKS, and LONMARK are trademarks of Echelon Corporation; NiagaraAX Framework is a trademark of Tridium, Inc.; BACnet is a registered trademark of the American Society of Heating, Refrigerating and Air-Conditioning Engineers. All other trademarks are the property of their respective owners. EnOcean Wireless Communication Infrared or Radio Communication Wi-Fi Communication * Availability subject to regional standards and regulations
Specifications subject to change without notice., Distech Controls, Innovative Solutions for Greener Buildings, and the Distech Controls logo are trademarks of Distech Controls Inc. Niagara AX Framework is a trademark of Tridium Inc. All other trademarks are property of their respective owner., Distech Controls Inc., 2014 to 2015. All rights reserved. 6/6 05DI-DSNETAX-50