Main Office Window Replacement



Similar documents
THIRD LAGUNA HILLS MUTUAL

NOTICE INVITING BIDS. CIVIC FACILITIES AIR CONDITIONING REPLACEMENT PROJECT, CIP No

Addendum No. 2 for Calcium Nitrate Treatment Solution. 1. Page 1, SOLICITATION DUE DATE/TIME: has been revised to read as follows:

Artist Application PASO ARTSFEST. Calling All Artists!

A site plan or floor plan clearly identifying the location(s) of all new replacement window(s)

(On behalf of the homeowners) The YUROK TRIBE REQUEST FOR PROPOSAL (RFP)

Electrical Contractor Pre-Qualification Packet. CHEM R/R Bus Duct & Generator (DMI) Project No. CP Notice No

San Joaquin General Hospital School of Radiologic Technology 2009 Prerequisite Verification

Mechanical Contractor Pre-Qualification Packet. SPSC N180 Computer Data Room Phase II. Project No. CP Notice No. Notice

NOTICE TO CONTRACTORS

Florida Department of Transportation 1000 NW 111 th Avenue, Room 6203 Miami, Florida

REPUBLIC OF KENYA OFFICE OF THE GOVERNOR NYERI COUNTY GOVERNMENT OF NYERI TENDER NO. CGN/49/

I Thomas Lumsden. PricewaterhouseCoopers LLP. 5 Accountants and Financial Advisors for Official Committee of Unsecured Creditors 6 83A

RDH Building Sciences Inc.

AGENDA STAFF REPORT. ASR Control

PREQUALIFICATION DOCUMENT FOR SUPPLIERS OF GOODS AND SERVICES ITEM:..

City of Glendale Window Replacement Information and Submittal Requirements

COUNTY ASSEMBLY OF MARSABIT P.O.BOX 29 MARSABIT

Garden Window. Montecito Series Vinyl Garden Window Architectural Manual

Ecorse Public Schools W. Outer Drive Ecorse, Michigan (313) / (313) (fax)

Katharine Teats House HABS No. CA Seventh Avenue San Diego San Diego County /J/Vf# <? California /WtO

TEST REPORT. Rendered to: INTERNATIONAL WINDOW Hayward, California. PRODUCT TYPE: Aluminum Hopper SERIES/MODEL: 7222

How To Get A College Loan From The California School District

ADVERTISEMENT FOR PREQUALIFICATION FOR THE FOLLOWING BID PACKAGES *RE-ADVERTISED*

Building Condition Assessment Report

This request for qualifications seeks the following type of service providers:

REQUEST FOR QUALIFICATIONS

WINDOWS AND PATIO DOORS

NOTICE: CALLING FOR PROPOSALS VOICE-OVER IP (VOIP) EQUIPMENT AND INSTALLATION ERATE ELIGIBLE SERVICES

FIELD TESTING SERVICES

ILLINOIS DEPARTMENT OF FINANCIAL AND PROFESSIONAL REGULATION INSTRUCTION SHEET MEDICAL CANNABIS DISPENSARY REGISTRATION FORM

REPUBLIC OF KENYA MINISTRY OF FOREIGN AFFAIRS AND INTERNATIONAL TRADE PRE-QUALIFICATION/REGISTRATION OF SUPPLIERS FY /

REQUEST FOR PROPOSAL SCHOOL PHOTOGRAPHY

BOROUGH OF HADDONFIELD CAMDEN COUNTY NEW JERSEY ARCHITECTURAL SERVICES RELATED TO THE HADDONFIELD LIBRARY REQUEST FOR PROPOSAL

The replacement or modification of existing windows shall comply with the following requirements:

From the Office of: MAHLUM ARCHITECTS 71 Columbia Street Floor 4 Seattle, WA 98104

Bids must be on the "BID FORM" provided and be submitted in a sealed envelope that is plainly marked "NEW VEHICLES BID".

TCGL invites offers for Sending Bulk s.

REQUEST FOR PROPOSAL (RFP) Facility Condition Assessment Services and Capital Planning and Management Software (CPMS)

A Complete Solution CREATING WALLS THAT DEFINE SPACE

U.S. Department of Justice. March 11, 2014

SWAN POINT YACHT & COUNTRY CLUB

TOWN of NEW BOSTON. Bid Package. Refurbishment and Upgrade of Basement of the New Boston Town Hall

REQUEST FOR PROPOSALS

STATE LIFE INSURANCE CORPORATION OF PAKISTAN Health & Accident Insurance, Peshawar Zone

Steve Brinkman Alain Pinel Realtors 167 S San Antonio Road Los Altos, CA RE: Foundation Inspection for 162 Del Monte Ave. Los Altos, CA 94022

California Building Officials 54th Annual Business Meeting March 14-17, 2016

STATE OF FLORIDA DEPARTMENT OF BUSINESS AND PROFESSIONAL REGULATION DIVISION OF FLORIDA LAND SALES, CONDOMINIUMS, AND MOBILE HOMES

WINDOW AND DOOR REPLACEMENT REQUIREMENTS

SILICON VALLEY INTERNET CAPITAL 301 UNIVERSITY AVENUE, PALO ALTO, CALIFORNIA

LOWEST FLOOR GUIDE I. LOWEST FLOOR DETERMINATION

INVITATION TO BID CITY OF HOPKINSVILLE

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

Series 3502 Thermal Series 3902 Fixed Thermal Architectural Grade Horizontal Sliding Window

CLEANING CONTRACT BID SPECIFICATIONS

LOWEST FLOOR GUIDE I. LOWEST FLOOR DETERMINATION. Previous Section Table of Contents

Foundation Evaluation Report for PROPERTY ADDRESS Houston, Texas August 30, Prepared for:

RELOCATION OF BUILDINGS

Tuscany Series Vinyl Replacement Windows 3-Part Specification

western transforming space window systems series 670 a new option for hinged window line

ANSWERING A PERSONAL INJURY, PROPERTY DAMAGE OR WRONGFUL DEATH COMPLAINT

Case PJW Doc 460 Filed 08/27/14 Page 1 of 3 IN THE UNITED STATES BANKRUPTCY COURT FOR THE DISTRICT OF DELAWARE : : : : : : : :

HomeSpec REPORT SUMMARY

Request for Proposal CONSTRUCTION MANAGEMENT

How To Bid On A Building Project In San Jose

SPACE LOCATION, ALLOCATION, LAYOUT AND MEASUREMENT STANDARDS POLICIES

The Cabin Shell Series

SERVICE PROVIDER CRITERIA AND CONTRACT REQUIREMENTS

REQUEST FOR PROPOSALS (RFP) For: Water Damage Repairs 1495 N. Tucker Ridge Rd. Okeechobee, FL 34974

CITY OF PORTSMOUTH PORTSMOUTH, NH Purchasing Department. Annual Fuel Bid - #01-14 INVITATION TO BID

CONTRACTOR REGISTRATION APPLICATION CALIFORNIA UNIFORM PUBLIC CONSTRUCTION COST ACCOUNTING ACT (CUPCCAA)

INSTRUCTIONS TO BIDDERS

Request for Proposal MAINTENANCE SERVICES FOR NEC TELEPHONE SYSTEMS. Luzerne County Information Technology Department LUZERNE COUNTY PENNSYLVANIA

Quality Building Products for over 50 Years

Vinyl Replacement Windows

REQUEST FOR PROPOSAL windows,sliding glass door repair and replacement contractors

ITEM NO. DESCRIPTION BIDDER CODE NO. UNIT COST UNIT COST 1 GALLON 5 GALLON. 1 Oil Base Exterior House Paint Mobille Paint 5-18 $29.

7:00 p.m. Regular Meeting April 9 12

Pumphouse Museum at the Historic Ottawa Beach Parks Park Township

Office Space Standards and Guidelines


ASBESTOS INSPECTION REPORT 2 Delaware Street, 38 and 39 North Henry Court South Burlington, VT AIP 84

International Peace Support Training Centre Westwood Park P O Box Karen, Kenya

Please note that exhibitor move out will not be permitted prior to 8:05 p.m and must be complete by 9:30pm.

Style Line Series Vinyl Windows & Doors

Window replacement guidelines

Plaisance 24. Sliding Systems. Sapa Building System

Transcription:

BOARD OF COMMISSIONERS P.O. BOX 249 ٠ AVILA BEACH CALIFORNIA 93424 JIM BLECHA President (805) 595-5400 ٠ Fax 595-5404 DAVE KIRK Vice President www.portsanluis.com BILL BARROW Secretary BRIAN KREOWSKI Commissioner STEPHEN A. McGRATH Harbor Manager DREW BRANDY Commissioner THOMAS D. GREEN Legal Counsel PHILLIP J. SEXTON, CPA Treasurer Invitation to Bid Main Office Window Replacement Sealed bids are due no later than: 1:00 P.M., Tuesday November 4th, 2014 Mandatory pre bid site visit (unless prior visit): 1:00 P.M., Tuesday October 28th, 2014 Meet at the Main Office Parking Lot near the entrance. 3950 Avila Beach Dr. Bid opening is public To submit a bid, complete the Bid Form and Return this entire packet in a sealed envelope plainly marked: BID WINDOW REPLACEMENT Failure to display this on your sealed bid envelope may result in bid disqualification. Faxed bids will not be accepted. US Postal Service express mail service is not available into Avila Beach. Use this address for regular mail: Use this address for Federal Express or other express mail service: Port San Luis Harbor District Port San Luis Harbor District PO Box 249 3950 Avila Beach Drive Avila Beach, CA 93424 Avila Beach, CA 93424 Phone: 805.595.5400 x0 Please contact the Planner/Analyst to obtain: 1. Instructions to Bidders 2. Bid Form Planner/Analyst Contact Information Chris Munson Telephone (805) 595 5431 or email chrism@portsanluis.com Page 1 of 4

Invitation for Bid Main Office Window Replacement Project Description: Port San Luis Harbor District (District) is requesting sealed bids to provide window replacement for the second floor of the Main Office building located at 3950 Avila Beach Drive. Six framed windows and six windows located in the gables which are glass only are to be replaced. The District desires to replace the framed windows with white interior, dark brown exterior, dual glazed windows as specified below. Quotes for both Milgard Tuscany vinyl replacement windows (or equal) and Milgard Quiet Line windows (or equal) are to be provided. The bids are to include the costs of installation, screens, coatings, grids, and removal of the old windows. Opening windows are to be sliding. Windows with grids are to include 5/8 flat interior, between the glass grids. Coatings are to be Dark Graylite 31 and Clear Low-E as noted in the following table. Measurements will need to be verified in person. The rake windows are to be glass only without fames. Currently one of the center rake windows has an air conditioning unit in half of it. The unit is to be removed and the whole section will be replaced with one piece of glass. Location Dimension Window Size Type Coating Aspect Harbor Manager 95.25" x 8030 XOX Framed w/ Grids Graylite 31 & Low E South "" 46.5" x 37.5" 4030 XO Framed w/ Grids Graylite 31 & Low E West Business Manager 70.5" x 6030 XOX Framed w/ Grids Graylite 31 & Low E South "" 46.5" x 24.5" 4020 XO Framed w/ Grids Low E East Admin. Analyst 70.5" x 6030 XOX Framed w/ Grids Low E North Hallway 22" x 38" 2030 OO? Framed w/ Grids Low E North East Rake See Exhibit A "" Glass Only Low E East "" See Exhibit A "" Glass Only Low E East "" See Exhibit A "" Glass Only Low E East West Rake See Exhibit A "" Glass Only Low E West "" See Exhibit A "" Glass Only Low E West "" See Exhibit A "" Glass Only Low E West ***All measurements approximate Page 2 of 4

EXHIBIT B MAIN OFFICE UPSTAIRS FRAMED WINDOWS ***All measurements are approximate*** 95.25" 20.5" 49.75" 20.5" 46.5" 37.5" South - Harbor Manager's Office West - Harbor Manager's Office (Opens vertically on both sides) 70.5" 46.5" 35" 24.5" South - Business Manager's Office East - Business Manager's Office (Opens vertically on both sides) 22" 70.5" ~38" 35" North - Stairwell (Does not open) North - Administrative Analyst's Office

EXHIBIT C MAIN OFFICE UPSTAIRS RAKE WINDOWS ***All measurements are approximate*** 23" 39.5" 35.5" 35.5" 30.5" 45" East Wall West Wall (Air conditioner to be removed and replaced with glass)