SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS



Similar documents
CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 79G SA 99G FILE NO. SA 79G SA 99G REFERENCE NO. SM700402

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER + SAP C181MA + SAP C181GA + SAP C181BA + SAP C241MA + SAP C241BA FILE NO.

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

Technical service manual 2009

14. Troubleshooting Guide

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

AIR CONDITIONER INSTALLATION MANUAL

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/

Appendix - Controllers 179

How To Measure Temperature On A Thermostat

Air Conditioners Technical Data

HP switch LP switch Discharge thermo Comp. Surface thermo

ECOCIAT. Domestic hot water heat recovery unit

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

Failure code manual. content

BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL

How To Power A Car With A Fan And A Fan (Power)

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

SERVICE Manual AIR CONDITIONER AWH090ZE0K. 1. Precautions. 2. Product Specifications. 3. Installation and Operating Instructions

Use and Care Manual. Model CPA12KH AIR CONDITIONER

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

SERVICE MANUAL INDOOR UNIT

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

york air-conditioning products Residential & VRF News 2015

Room Air Conditioner SVC MANUAL(Exploded View)

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS

SERVICE MANUAL MSZ-HJ25VA MSZ-HJ35VA MSZ-HJ50VA INDOOR UNIT. No. OBH647. Models. Revision A: MSZ-HJ50VA- E1 has been added.

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS

Technical Service Manual. Version One

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

SiBE D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER ( Split system, air to air heat pump type )

SERVICE MANUAL MUZ-GE09NA MUZ-GE12NA MUZ-GE15NA MUZ-GE18NA MUZ-GE24NA MUY-GE09NA MUY-GE12NA MUY-GE15NA MUY-GE18NA MUY-GE24NA OUTDOOR UNIT

13. Troubleshooting. Indoor unit s LED indication of Corona DC inverter unit. Indoor unit s LED indication of Alfa DC inverter unit

Troubleshooting Your Refrigerator

ABNORMAL OPERATION Error code Display. Specifics Error Code. Subsection Error Code. Subsection and Specifics Error code target

USER S MANUAL HSC-24A

SiUS Service Manual. Inverter Pair Wall Mounted Type K-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

WALL MOUNTED SPLIT TYPE AIR CONDITIONER

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

MDT5N25 & MTD5N40 SERVICE PARTS

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

SERVICE MANUAL INDOOR UNIT

AFE424 SERVICE PARTS

TMS TANK MANAGEMENT SYSTEM

Split Type Inverter Room Air Conditioner OPERATION MANUAL

SiUS Service Manual. Inverter Pair FTXS-L Series FDXS-L Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

AIR-CONDITIONER SPLIT TYPE

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

ESPD8-301R MODEL ESP-D FAN COIL UNIT TROUBLESHOOTING GUIDE

SERVICE MANUAL REFRIGERATION

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

OWNER S MANUAL VMH 09/12/18/27/36 InverterFlex

Operating Instructions Split System Air Conditioner

SYLLABUS For BASIC TRADE COURSE (360 Hours) On REFRIGERATION AND AIR CONDITIONING

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

0.8 GWHN09EANK3A1A/I (OR GWHN09EANK3A2A/I) 1060/960/860/ / Cross flow fan 1. Aluminum fin-copper tube *25.4*228.6 MP24BA 1.

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

INDOOR UNIT/OUTDOOR UNIT

HERZ-Thermal Actuators

AUTOMOTIVE AIR CONDITIONING SYSTEM.

SERVICE & MAINTENANCE MANUAL

Split units TH with hermetic compressors

Room Air Conditioner Service and Parts Manual

Air Conditioners. Technical Data. Wall Mounted Unit. RX-JV/GV

Portable Air Conditioner

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL


CS-XE9EKE CU-XE9EKE CS-XE12EKE CU-XE12EKE

User Manual THR840DUK Digital Thermostat

Split Type Room Air Conditioner. KSWM units

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

Split Air Conditioner

Transport Air Conditioning TRANSPORT AIR CONDITIONING OPERATOR S MANUAL. for SPLIT SYSTEM. Bus Air Conditioning Units.

FOXAIR 60/50 ALL MODELS

SERVICE MANUAL INDOOR UNIT MSZ-EF35VEW MSZ-EF22VEB - - E1 MSZ-EF25VEB E1 MSZ-EF35VEB - - E1 MSZ-EF35VEB E1 MSZ-EF35VES - E1 - E1 MSZ-EF22VEW -

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

PANASONIC TROUBLE SHOOTING GUIDE

Transcription:

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER INDOOR UNIT AH-129 AH-MP14 OUTDOOR UNIT AU-129 AU-MP14 CONTENTS SPECIFICATIONS...2 EXTERNAL DIMENSIONS...4 WIRING DIAGRAMS...5 ELECTRICAL PARTS...6 MICROCOMPUTER CONTROL SYSTEM...7 PRINTED WIRING DIAGRAM...8 FUNTIONS...10 TROUBLESHOOTING...14 REFRIGERATION CYCLE AND PERFORMANCE CURVES...16 DISASSEMBLING PROCEDURE...17 REPLACEMENT PARTS LIST...25 SHARP CORPORATION SHARP CORPORATION 1

CHAPTER 1. PRODUCT SPECIFICATION [1] SPECIFICATION 1. AH-129 / AU-129 ITEMS INDOOR UNIT OUTDOOR UNIT AH-129 AU-129 Cooling capacity kw 3.50 Moisture removal Liters/h Electrical data Phase Single Rated frequency Hz 50 Rated voltage V 220 Rated current A 5.1 Rated input * W 1090 Power factor % 97-99 Compressor Type Hermetically sealed rotary type Model RH207VXGT Oil charge 520cc (DIAMOND MS56) Refrigerant system Evaporator Slit fin and Grooved tube type Condenser Slit fin and Grooved tube type Control Capillary tube Refrigerant volume 960g Noise level High db(a) 39 48 Mid. db(a) 33 Low db(a) 29 Fan system Drive Direct drive Air flow quantity High m3/min. 10.2 27 Mid. m3/min. 9.6 Low m3/min. 8.7 Fan Cross flow fan Propeller fan Connections Refrigerant coupling Flare type Refrigerant tube size Gas, Liquid 3/8", 1/4" Drain piping mm O.D φ 18 Others Safety device Compressor : Internal protector Fan motor : Thermal fuse / Protector Fuse, Micro computer control Air filters Polypropylene net (Washable) Net dimensions Width mm 790 730 Height mm 278 540 Net weight Depth mm kg 198 10 250 34 2

2. AH-MP14 / AU-MP14 ITEMS INDOOR UNIT OUTDOOR UNIT AH-MP14 AU-MP14 Cooling capacity kw 3.50 Moisture removal Liters/h Electrical data Phase Single Rated frequency Hz 50 Rated voltage V 220 Rated current A 5.1 Rated input * W 1090 Power factor % 97-99 Compressor Type Hermetically sealed rotary type Model RH207VXGT Oil charge 520cc (DIAMOND MS56) Refrigerant system Evaporator Slit fin and Grooved tube type Condenser Slit fin and Grooved tube type Control Capillary tube Refrigerant volume 960g Noise level High db(a) 39 48 Mid. db(a) 33 Low db(a) 29 Fan system Drive Direct drive Air flow quantity High m3/min. 10.2 27 Mid. m3/min. 9.6 Low m3/min. 8.7 Fan Cross flow fan Propeller fan Connections Refrigerant coupling Flare type Refrigerant tube size Gas, Liquid 3/8" φ, 1/4" Drain piping mm O.D φ 18 Others Safety device Compressor : Internal protector Fan motor : Thermal fuse / Protector Fuse, Micro computer control Air filters Polypropylene net (Washable) Net dimensions Width mm 790 730 Height mm 278 540 Net weight Depth mm kg 198 250 10 34 3

[2] EXTERNAL DIMENSION 1. Indoor unit (AH-129 / AH-MP14) 790 198 278 2. Outdoor unit (AU-129 / AU-MP14) 515 135 72 730 250 136 81 540 299 324 37.5 12 58 4.5 14 165 167.5 4

[3] WIRING DIAGRAM Indoor Unit (AH-129) Indoor Unit (AH-MP14) Outdoor (AU-129 / AU-MP14) 5

CHAPTER 2. ELECTRIC CIRCUIT [1] ELECTRIC PARTS 1. AH-129 / AU-129 DESCRIPTION MODEL REMARKS SITE Compressor RH207VXGT 220V, 50Hz, 1120W OUTDOOR Indoor fan motor CMOT-A448JBKZ 220-240V, 50Hz INDOOR Outdoor fan motor CMOTLB182JBEZ 220-240V, 50/60Hz OUTDOOR Indoor fan motor capacitor 450V, 2µF INDOOR Outdoor fan motor capacitor 400V, 2µF OUTDOOR Running capacitor 400V, 30µF OUTDOOR Transformer Primary ; AC 220 / 240V 50Hz Secondary ; AC15.3V, 50Hz INDOOR Fuse 250V, 2.5A INDOOR 2. AH-MP14 / AU-MP14 DESCRIPTION MODEL REMARKS SITE Compressor RH207VXGT 220V, 50Hz, 1120W OUTDOOR Indoor fan motor CMOT-A448JBKZ 220-240V, 50Hz INDOOR Outdoor fan motor CMOTLB182JBEZ 220-240V, 50/60Hz OUTDOOR Indoor fan motor capacitor 450V, 2µF INDOOR Outdoor fan motor capacitor 400V, 2µF OUTDOOR Running capacitor 400V, 30µF OUTDOOR Transformer Primary ; AC 220 / 240V 50Hz Secondary ; AC15.3V, 50Hz INDOOR Fuse 250V, 2.5A INDOOR 6

[2] MICRO-COMPUTER CONTROL SYSTEM 1. Electronic Control Diagram Indoor unit (AH-129 / AH-MP14) 7

2. PRINTED WIRING DIAGRAM 2.1 Indoor (AH-129) 8

2.2 Indoor (AH-MP14) 9

CHAPTER 3. FUNCTIONS [1] FUNCTION TEMPERATURE CONTROL CHARACTERISTIC 1.1. COOL operation In the "COOL" mode, the thermostat circuit is controlled by five thermostat lines (C1 thru C5). 2.2. DRY On the switch on, the compressor always starts to operate for 2 minutes with fan speed "DL". The microcomputer reads the room temperature 2 minutes after this first compressor operation. This room temperature is set as the preset temperature The preset temperature ranges t from ti 18 ll C to 32 C. When the room temperature is below 18 C, the preset temperature is set to 18 C, and when the room temperature is over 32 C, the preset temperature is set to 32 C. Dry operation is divided into three zones (Cooling zone, Dehumidifying zone and Circulating zone) by thermostat lines (D1 to D3), and the compressor and the fan motor are controlled in each zone as shown in Table. 18 32 Preset temperature (C ) 1.2. DRY In the "DRY" mode, the thermostat circuit is controlled by three thermostat lines (D1 thru D3). 18 32 Preset temperature (C ) 18 32 Preset temperature (C ) Compressor Fan speed Cooling zone (1) & (5) ON "DH" Dehumidifying zone (2) & (4) ON "DL" Circulating zone (3) OFF "DL" or OFF FAN SPEED Fan speeds are given by the indoor fan motor, "DL"~"CH" which are available in the following operation mode. OPERATION MODES 2.1. COOL operation NOTE: Fan speed may be changed, without warning. The compressor turns on or off, at the thermostat lines C3 and C4. The outdoor fan motor is also controlled with the compressor. Fan speed Fan switch Fan switch (AUTO) AH-129 / AH-MP14 (r.p.m) 800 DL DRY DH 890 CL COOL LOW 800 CAL 840 CM COOL MID COOL 980 CAH 1020 CH COOL HIGH 1170 FREEZE PREVENTIVE When the indoor pipe temperature falls below 3 C cool or dry operation for 3 minutes or more, the compressor is turned off. When the indoor pipe temperature rises above 7 C in cool or dry operation for 3 minutes or more, the compressor is turned on. 18 32 Preset temperature (C ) 10

TEST RUN If the "AUX" button on the unit is pressed for 5 seconds or more during operation, cool test operation starts. The operation LED (red) flickers during test run. In cool mode continuous compressor on operation is performed. In dry mode the operation is in dehumidifying zone. When ONE-HOUR timer is set, the unit turns off automatically after one hour. The one hour timer operation has priority over other time operation, such as the TIMER ON and TIMER OFF. If the ONE-HOUR TIMER button is pressed again during operation, the unit OUTPUTS IN EACH OPERATION MODE Mode Valve Coil Outdoor Indoor Fan Motor Fan Motor O Cooling ON ON ON OFF Compressor O Circulating OFF OFF ON OFF U TIMER Cooling ON ON L/UL OFF } Dehumidiflying ON ON UL/D OFF 6.1. ON/OFF Timer When the unit operates during one hour after the OFF-time is set, tem- o Circulating OFF OFF D/OFF OFF perature setting is automatically shifted ((After 1H) (After 1.5H) (After 2H) in operation and dry operation). When the ON-timer is set in cool operation, operation starts before 0 to 30 minutes(depends on the room temperature) so that preset temperature is obtaind at set time. 6.2. 1 hour timer +0.33 C +0.66 C +1 C AUTOMATIC AIR CONDITIONING When automatic air conditioning is selected, the operation mode and preset temperature are set automatically according to the room temperature on starting operation. Room temperature Operation Mode Preset Temperature at operation start Above 28 C 26 C 26 C > 28 C COOL 25 C 24 C > 26 C 24 C Below 24 C DRY Room temperature at operation start When DRY mode is selected by the micro computer with AUTO operation, the fan speed lamps on the indoor unit panel will indicate identically with the fan speed symbols on the remote control dispaly, as the FAN speed setting is changed accordingly. Despite, POWER ON START If the connecting wire "POWER ON" (JP99) is cut on the PWB ass'y, when the power is supplied by turning on a circuit breaker, the air conditioner automatically starts of operation in "AUTO". (Refer to Printed Wiring Board.) AUTO RESTART 11.1. When JP5 is ON Power failuer occurs during operation, the unit will restart in the same operation mode as before recovery. 11.2. When JP5 is OFF Auto restart function is not available. AUTOMATIC FAN SPEED When the automatic fan speed is selected in cool operation, the fan speed is automatically changed by the thermostat lines C1 to C3 in cool operation. 11

[2] TEST MODE 1. AH-129 Keep pushing the "AUX." buttons and supply the power, the system will go to the test mode. In this mode, the output of operation is switched by pushing the ""AUX." button in the unit or the "OI" button in the remote controller. Normal outputs are shown in Table. STEP No. BUZZER OUTPUT "-" : NO CHECK, "O" : ON, "X" : OFF FAN LOUVER OUTDOOR LED 101 LED 102 LED 103 LED 104 RED YELLOW GREEN BLUE STEP0 BEEP2 O *1 O*2 O X X X X *1 : 7 C<(ROOM TEMP.)<42 C *2 : -2 C<(PIPE TEMP.)<45 C STEP1 BEEP1 X X O X O OPEN O MOTOR STEP2 BEEP1 O RPM X O X O X X STEP3 BEEP1 O *4 X X O X O *4 : O --- POWER ON INVALIDITY STEP4 BEEP1 O IC8 O O X O X X *4 : X --- POWER ON VALIDITY STEP5 BEEP1 O O O X O X O STEP6 BEEP1 X R.C. X O X O X X STEP7 BEEP1 X X X X O X O STEP8 BEEP1 X X O X O X X STEP9 BEEP1 O X O X O X O STEP10 BEEP1 O O O X X CLOSE O 1. AH-MP14 STEP No. BUZZER OUTPUT "-" : NO CHECK, "O" : ON, "X" : OFF FAN LOUVER OUTDOOR PLASMA MOTOR CLUSTER LED 101 LED 102 LED 103 LED 104 RED YELLOW GREEN BLUE STEP0 BEEP2 O *1 O*2 O O X X X X *1 : 7 C<(ROOM TEMP.)<42 C *2 : -2 C<(PIPE TEMP.)<45 C STEP1 BEEP1 X X O X O OPEN O X STEP2 BEEP1 O RPM O O O O X X O STEP3 BEEP1 O *4 X X O X O O *4 : O --- POWER ON INVALIDITY STEP4 BEEP1 O IC8 O O X O X X X *4 : X --- POWER ON VALIDITY STEP5 BEEP1 X O O X O X O X STEP6 BEEP1 X R.C. X O X O X X X STEP7 BEEP1 X X X X O X O X STEP8 BEEP1 X X O X O X X X STEP9 BEEP1 O X O X O X O X STEP10 BEEP1 O O O X X CLOSE O X 12

[3] DIAGNOSIS PROCEDURE 1. AH-129 / AH-MP14 When indoor fan motor is out of order occurs, indoor fan motor and louver are all stopped and the operation LED(red) turns on or off synchronously with the timimg of the timer LED. When the thermistor for room temperature or pipe temperature is open or short state, the operation LED turns on or off synchrnoously with the timing of the timer LED by pushing continously for more than 5 seconds "AUX." button during suspension of operati Timing chart of Timer LED and Operation LED of DIAGNOSIS PROCEDURE. When "OI" button the remote controller or "AUX." button in the unit is pushed, the unit is free from DIAGNOSIS When PROCEDURE the louver unit is not properly installed, all lamps on the indicator panel will blink operation are all stop and Remote signal is not accept. 13

CHAPTER 4. TROUBLESHOOTING 14

CHAPTER 4. TROUBLESHOOTING 15

16

DISASSEMBLING PROCEDURE MODEL: AH-129,AH-MP14 [1] INDOOR UNIT Be sure to disconnect the power supply cord from the AC power outlet before starting the disassembly procedure. When reassembling the unitafter repairing, besure to install screws to their original positions. The screws used are not the same in specifications such as corrosion-resistant treatment, tip shape and length. After the air conditioner is repaired or parts or replaced, measure insulation resistance of the equipment using and insulation resistance meter. if the measured resistance is lower than 1M Ω, inspect parts and repair or replace defective parts. 1) Open the open panel. 5) Pushing the 2 hooks, disconnect the louver base(2) 2) Remove screw fixing the cord clamp. 6) Remove 2 air filters. 3) Remove the cord clamp. 7) Remove the Screw cover (use the(-)driver). 4) Remove the unit-to-unit wiring from the terminal board(4). 8) Remove the cover. 17

9) Remove 5 screws fixing the front panel. 14) Remove the control box. 10) Pull the front panel up. 11) Remove a screw fixing the Control box cover, and remove it 15) Remove the LED guide. 12) Remove the 2 screws fixing the control box. board 16) Pushing the 2 hooks of the holder, remove the display 13) Disconnect the thermistor. 17) Remove a screw fixing the holder. 18

18) Remove the holder. 21) Remove the screw fixing the evaporator ass'y and - evaporator. 22) Remove the drain guide. 19) Remove 2 screws fixing the holder. (AH-MP14) 23) Remove 2 screws fixing the evaporator. 20) Remove 2 screws fixing the PC cover. (AH-MP14) 24) Remove 2 screw fixing the evaporator and bushing holder. 19

25) Pull the evaporator ass'y up. 28) Remove the screw fixing cross flow fan. 26) Take out the left side of the drain pan. 29) Hold up the left side of evaporator, pull out cross flow fan Attention: In case of assembly. Part A is inserted into the drain part of the drain pan. 27) Take out the right side of the drain pan leaving drainhose in cabinet. 20

MODEL: AU-129,AU-MP14 [2] OUTDOOR UNIT 1) Loose a screw fixing the side cover 3) Loose the unit-to-unit cord. 2) Loose 2 screws fixing the terminal cover and 1 screw- 4) Loose 6 screws fixing the top panel. fixing the cord clamp. ( Right side view ) 21

( Left side view ) 5) Loose 5 screws fixing the front panel. (Right side view) ( Left side view ) ( Front view ) ( Front view ) 22

6) Cut 3 plastic bands. 9) Remove 3 terminals of compressor. 7) Remove 2 terminals. (connecting with fan condenser) 10) Loose 4 screw fixing the control box. 8) Remove the terminal cover. 11) Take out the control box 23

1. DISASSEMBLING PROCEDURE OF THE FAN 2. ASSEMBLING PROCEDURE OF COMPRESSOR COVER 1) Loose the fan nut and take out fan. 1) Remove: Unlace the fastenner and pull the compressor cover out from left side. [a) b)] 2) Assembly: Insert the compressor cover from left side, cover the tube and fasten. [b) a)] 2) Loose 4 screws fixing fan motor. 24