0.8 GWHN09EANK3A1A/I (OR GWHN09EANK3A2A/I) 1060/960/860/ / Cross flow fan 1. Aluminum fin-copper tube *25.4*228.6 MP24BA 1.

Size: px
Start display at page:

Download "0.8 GWHN09EANK3A1A/I (OR GWHN09EANK3A2A/I) 1060/960/860/760. 8 / 1 0.2 Cross flow fan 1. Aluminum fin-copper tube 7 2-1.5 559*25.4*228.6 MP24BA 1."

Transcription

1 2 Model Function Rated Voltage Rated Frequency Total Capacity (W) Power Input (W) Rated Input (W) Rated Current (A) Air Flow Volume (m 3 /h) Dehumidifying Volume (l/h) C.O.P / EER (W/W) Indoor unit Model of Indoor Unit Fan Motor Speed (r/min) (H/M/L) Output of Fan Motor (w) Input of Heater (w) Fan Motor Capacitor (uf) Fan Motor RLA(A) Fan Type-Piece Diameter-Length (mm) Evaporator Pipe Diameter (mm) Row-Fin Gap(mm) Coil length (l) x height (H) x coil width (L) Swing Motor Model Output of Swing Motor (W) Fuse (A) Sound Pressure Level db (A) (H/M/L) Sound Power Level db (A) (H/M/L)*** Dimension (W/H/D)( mm) Dimension of Package (L/W/H)( mm) GWHN07EANK3AA OR GWHN09EANK3AA OR GWHN07EANK3A2A GWHN09EANK3A2A COOLING HEATING COOLING HEATING V V 50Hz 50Hz 236W(7900Btu/h) 2500W(8500Btu/h) 2637W(9000Btu/h) 2785W(9500Btu/h) /-/-/- 420/-/-/ / /3.22 GWHN07EANK3AA/I (OR GWHN09EANK3AA/I (OR GWHN07EANK3A2A/I) GWHN09EANK3A2A/I) 060/960/860/760 8 / 0.2 Cross flow fan φ97*538 Aluminum fin-copper tube *25.4*228.6 MP24BA.5 PCB 3.5A 38/35/32/28 48/45/42/38 70X250X80 755X260X35 060/960/860/760 8 / 0.2 Cross flow fan φ97*538 Aluminum fin-copper tube *25.4*228.6 MP24BA.5 PCB 3.5A 38/35/32/28 48/45/42/38 70X250X80 755X260X35

2 HUMMER Model of Outdoor Unit Compressor Model Compressor Type L.R.A. (A) Compressor RLA(A) Compressor Power Input(W) Overload Protector GWHN07EANK3AA/O GWHN09EANK3AA/O QXA-B02uC30 QXA-B06uC30 Rotory Rotory B H B H Outdoor unit Connecti on Pipe Throttling Method Starting Method Working Temp Range ( ) Condenser Pipe Diameter (mm) Rows-Fin Gap(mm) Coil length (l) x height (H) x coil width (L) Fan Motor Speed (rpm) (H/M/L)** Output of Fan Motor (W) Fan Motor RLA(A) Fan Motor Capacitor (uf) Air Flow Volume of Outdoor Unit Fan Type-Piece Fan Diameter (mm) Defrosting Method Climate Type Capillary Capillary Capacitor Capacitor -5~46-5~46 Aluminum fin-copper tube Aluminum fin-copper tube *400.5* *406* Axial fan Axial fan Auto defrost Auto defrost T T I I IP24 IP24 Isolation Moisture Protection Permissible Excessive Operating Pressure for the Discharge Side(MPa) Permissible Excessive Operating Pressure for the Suction.2.2 Side(MPa) Sound Pressure Level db (A) (H/M/L) Sound Power Level db (A) (H/M/L) Dimension (W/H/D)( mm) 720X430X X430X260 Dimension of Package (L/W/H)( mm) 765X350X X350X490 Net Weight /Gross Weight (kg) 25/29 25/29 Refrigerant Charge (kg) R40a/0.53 R40a/0.7 Length (m) 4 4 Outer Diameter Max Distance Liquid Pipe (mm) Height (m) Φ6(/4 ) 5 Φ6(/4 ) 5 Gas Pipe (mm) Length (m) Φ9.52(3/8 ) 0 Φ2(/2 ) 0 The above data is subject to change without notice. Please refer to the nameplate of the unit.

3 Model Function Rated Voltage Rated Frequency Total Capacity (W) Power Input (W) Rated Input (W) Rated Current (A) Air Flow Volume (m 3 /h) Dehumidifying Volume (l/h) C.O.P / EER (W/W) Model of Indoor Unit GWHN2EBNK3AA OR GWHN2EBNK3A2A COOLING 3224W(000Btu/h) V 50Hz /3.22 HEATING 3575W(2200Btu/h) GWHN2EBNK3AA/I (OR GWHN2EBNK3A2A/I) Indoor unit Fan Motor Speed (r/min) (H/M/L) Output of Fan Motor (w) Input of Heater (w) Fan Motor Capacitor (uf) Fan Motor RLA(A) Fan Type-Piece Diameter-Length (mm) Evaporator Pipe Diameter (mm) Row-Fin Gap(mm) Coil length (l) x height (H) x coil width (L) Swing Motor Model Output of Swing Motor (W) Fuse (A) Sound Pressure Level db (A) (H/M/L) Sound Power Level db (A) (H/M/L)*** Dimension (W/H/D)( mm) Dimension of Package (L/W/H)( mm) Net Weight /Gross Weight (kg) 200/00/980/ / 0.28 Cross flow fan φ97*583 Aluminum fin-copper tube *25.4*228.6 MP24BA.5 PCB 3.5A 40/38/35/3 50/48/45/4 770X250X80 80X278X /2

4 HUMMER Outdoor unit Connecti on Pipe Model of Outdoor Unit Compressor Model Compressor Type L.R.A. (A) Compressor RLA(A) Compressor Power Input(W) Overload Protector Throttling Method Starting Method Working Temp Range ( ) Condenser Pipe Diameter (mm) Rows-Fin Gap(mm) Coil length (l) x height (H) x coil width (L) Fan Motor Speed (rpm) (H/M/L)** Output of Fan Motor (W) Fan Motor RLA(A) Fan Motor Capacitor (uf) Air Flow Volume of Outdoor Unit Fan Type-Piece Fan Diameter (mm) Defrosting Method Climate Type Isolation Moisture Protection Permissible Excessive Operating Pressure for the Discharge Side(MPa) Permissible Excessive Operating Pressure for the Suction Side(MPa) Sound Pressure Level db (A) (H/M/L) Sound Power Level db (A) (H/M/L) Dimension (W/H/D)( mm) Dimension of Package (L/W/H)( mm) Net Weight /Gross Weight (kg) Refrigerant Charge (kg) Length (m) Liquid Pipe (mm) Outer Diameter Gas Pipe (mm) Height (m) Max Distance Length (m) GWHN2EBNK3AA/O C-RV33HC Rotory B H Capillary Capacitor -5~46 Aluminum fin-copper tube *506* Axial fan 400 Auto defrost T I IP X540X X590X360 35/40 R40a/ Φ6(/4 ) Φ9.52(3/8 ) 5 0 The above data is subject to change without notice. Please refer to the nameplate of the unit.

5 Model Function Rated Voltage Rated Frequency Total Capacity (W) Power Input (W) Rated Input (W) Rated Current (A) Air Flow Volume (m 3 /h) Dehumidifying Volume (l/h) C.O.P / EER (W/W) Indoor unit Model of Indoor Unit Fan Motor Speed (r/min) (H/M/L) Output of Fan Motor (w) Input of Heater (w) Fan Motor Capacitor (uf) Fan Motor RLA(A) Fan Type-Piece Diameter-Length (mm) Evaporator Pipe Diameter (mm) Row-Fin Gap(mm) Coil length (l) x height (H) x coil width (L) Swing Motor Model Output of Swing Motor (W) Fuse (A) Sound Pressure Level db (A) (H/M/L) Sound Power Level db (A) (H/M/L)*** Dimension (W/D/H)( mm) Dimension of Package (W/D/H)( mm) Net Weight /Gross Weight (kg) COOLING GWHN8EDNK3A2A HEATING V~ 50Hz /500/ / 3.0 GWHN8EDNK3A2A/I 250/080/ uf 0.2 Cross flow fan φ92 X 66 Aluminum fin-copper tube ( 铝 箔 铜 管 ) Φ X324X25.4 MP24BA 2 PCB 3.5A Transformer 0.2A 43/39/33 53/49/43 830X285X X 370 X 285 /4

6 HUMMER Outdoor unit Connecti on Pipe Model of Outdoor Unit Compressor Model Compressor Type L.R.A. (A) Compressor RLA(A) Compressor Power Input(W) Overload Protector Throttling Method Starting Method Working Temp Range ( ) Condenser Pipe Diameter (mm) Rows-Fin Gap(mm) Coil length (l) x height (H) x coil width (L) Fan Motor Speed (rpm) (H/M/L)** Output of Fan Motor (W) Fan Motor RLA(A) Fan Motor Capacitor (uf) Air Flow Volume of Outdoor Unit Fan Type-Piece Fan Diameter (mm) Defrosting Method Climate Type Isolation Moisture Protection Permissible Excessive Operating Pressure for the Discharge Side(MPa) Permissible Excessive Operating Pressure for the Suction Side(MPa) Sound Pressure Level db (A) (H/M/L) Sound Power Level db (A) (H/M/L) Dimension (W/D/H)( mm) Dimension of Package (W/D/H)( mm) Net Weight /Gross Weight (kg) Refrigerant Charge (kg) Length (m) Outer Diameter Max Distance Liquid Pipe (mm) Gas Pipe (mm) Height (m) Length (m) GWHN8EDNK3A2A/O C-RV90HA Hermetic motor compressor B E Capillary Capacitor -7 T 43 Aluminum fin-copper tube ( 铝 箔 铜 管 ) X660X uF 2000 Axial fan 473 Auto defrost T I IP X680X X720X428 46/50 R40A/.05 4 Φ6(/4 ) Φ2(/2 ) 5 0 The above data is subject to change without notice. Please refer to the nameplate of the unit.

7 Model Function Rated Voltage Rated Frequency Total Capacity (W) Power Input (W) Rated Input (W) Rated Current (A) Air Flow Volume (m 3 /h) Dehumidifying Volume (l/h) C.O.P / EER (W/W) Indoor unit Model of Indoor Unit Fan Motor Speed (r/min) (H/M/L) Output of Fan Motor (w) Input of Heater (w) Fan Motor Capacitor (uf) Fan Motor RLA(A) Fan Type-Piece Diameter-Length (mm) Evaporator Pipe Diameter (mm) Row-Fin Gap(mm) Coil length (l) x height (H) x coil width (L) Swing Motor Model Output of Swing Motor (W) Fuse (A) Sound Pressure Level db (A) (H/M/L) Sound Power Level db (A) (H/M/L)*** Dimension (W/D/H)( mm) Dimension of Package (W/D/H)( mm) Net Weight /Gross Weight (kg) COOLING GWHN24ECNK3A2A HEATING V~ 50Hz /670/ GWHN24ECNK3A2A/I 200/050/ / 0.4 Cross flow fan φ96 X 797 Aluminum fin-copper tube Φ X340.5X25.4 MP35XX 2.5 PCB 3.5A Transformer 0.2A 48/45/42/39 58/55/52/49 020X228X30 078X390X325 5/20

8 HUMMER Outdoor unit Connecti on Pipe Model of Outdoor Unit Compressor Model Compressor Type L.R.A. (A) Compressor RLA(A) Compressor Power Input(W) Overload Protector Throttling Method Starting Method Working Temp Range ( ) Condenser Pipe Diameter (mm) Rows-Fin Gap(mm) Coil length (l) x height (H) x coil width (L) Fan Motor Speed (rpm) (H/M/L)** Output of Fan Motor (W) Fan Motor RLA(A) Fan Motor Capacitor (uf) Air Flow Volume of Outdoor Unit Fan Type-Piece Fan Diameter (mm) Defrosting Method Climate Type Isolation Moisture Protection Permissible Excessive Operating Pressure for the Discharge Side(MPa) Permissible Excessive Operating Pressure for the Suction Side(MPa) Sound Pressure Level db (A) (H/M/L) Sound Power Level db (A) (H/M/L) Dimension (W/D/H)( mm) Dimension of Package (W/D/H)( mm) Net Weight /Gross Weight (kg) Refrigerant Charge (kg) Length (m) Outer Diameter Max Distance Liquid Pipe (mm) Gas Pipe (mm) Height (m) Length (m) GWHN24ECNK3A2A/O ASH275CV-C8LU rotary compressor 内 置 Capillary Capacitor -7 T 43 Aluminum fin-copper tube Φ X660X m 3 /h Axial fan Φ472 Auto defrost T I IP X42X700 00/450/755 59/64 R40/.7 4 Φ9.52 Φ6 5 0 The above data is subject to change without notice. Please refer to the nameplate of the unit.

9 HUMMER 3 Indoor Unit Air inlet Front Panel Filter Air outlet Outdoor Unit Air inlet Air outlet

10 4 Overall and Installing Dimension of Indoor Unit Air inlet grill Left Tube-exit Sign Top View Right Tube-exit Sign Rear View Ceiling Model W(mm) H(mm) D(mm) 7K 9K K

11 HUMMER Air inlet grill Left Tube-exit Sign Top View Right Tube-exit Sign Rear View Ceiling Model W(mm) H(mm) D(mm) 7K 9K K K K

12 Overall and Installing Dimension of Outdoor Unit 320 over over over over Bolt Nut Wrench

13 HUMMER Handle over over over over Bolt Nut Wrench

14 Unit over over over over Bolt Nut Wrench

15 HUMMER Unit Nut Bolt Wrench

16 5 HUMMER

17

18 6 Manual of functions of remote controller and operation method Manual of functions of remote controller for 9K,2K units 6.. Temperature parameter The room setting temperature(tpreset) The room ambient temperature (Tamb) 6..2Basic Functions Once energized, the compressor should in no way be restarted unless after 3-minute time interval at least. For the first energization, the compressor will be started without 3-minute lag. The compressor, once started,will not be stopped within 6 minutes with the change of room temperature. Cooling Mode Cooling Conditions and Process When T amb. T preset +, the unit will run under cooling mode, in which case the compressor and outdoor fan will start and the indoor fan will run at setting speed. When T amb. T preset -, the compressor and the outdoor fan will stop, the indoor fan will run at setting speed. When T preset - <T amb.< T preset +, the unit will maintain its original operating status. Under this mode, the switch valve will not be powered on, and the setting temperature range is6 ~30. T preset + T preset - T amb 6 min. 3 min. 6 min. Start cooling Original operating status Stop cooling Compressor Outdoor fan Indoor fan Preset speed Protection Antifreeze Protection Run Stop If it is detected that the system is under antifreeze protection, the compressor and outdoor fan will be stopped, and the indoor fan will run at setting speed. When antifreeze protection is released and the compressor has stopped for 3 minutes, the unit will resume its original operating status. During antifreeze protection Compressor Outdoor fan Indoor fan 3 min. Preset speed DRY Modes Run The conditions and process of DRY When T amb. > Tpreset+2, the unit will run under DRY cooling mode, in which case the compressor and outdoor fan will be started and the indoor fan will run at low speed. When T preset -2 T amb. T preset +2, the unit will run under DRY mode, in which case the indoor fan will keep run at low speed, the compressor and the outdoor fan will be stopped after 6 minutes. After 4 minutes,the compressor and the outdoor fan will be restarted. The dehumidifying process is so repeated in cycle. When T amb.< T preset -2, the compressor and outdoor fan will be stopped, the indoor fan will run at low speed.. Under this mode, the switchover valve will not be powered on, and the setting temperature range is6 ~30. Stop

19 T preset +2 T preset -2 T amb 6 min. 6 min. 4 min. 4 min. Cooling Dry Stop Compressor Outdoor fan Indoor fan low speed Run Stop Protection Antifreeze Protection Upon meeting the cooling condition, if it is detected that the system is under antifreeze protection, the compressor and outdoor fan will be stopped,and the indoor fan will run at low speed. When antifreeze protection is released and the compressor has stopped for 3 minutes, the complete unit will resume its original operating status. Upon meeting the dehumidify condition, if it is detected that the system is under antifreeze protection, the com -pressor and outdoor fan will be stopped,and the indoor fan will run at low speed. When antifreeze protection is released and the compressor has stopped for 4 minutes, the complete unit will resume its original operating status HEAT Mode (there is no this mode for cooling only unit) The conditions and process of heating When Tamb Tset +2,the system enters heating running, in this case, the reversal valve, compressor, outer fan enter simultaneously running.the indoor fan will delay at most for 2min to run. When Tamb Tset +4,the compressor and outdoor fan will stop, but the reversal valve is still with power on, the indoor unit will run at setting fan speed for 60s then will stop. When Tset +2 <Tamb < Tset +4,the unit will maintain its original operating status. Under this mode, the switchover valve will be powered on, and the setting temperature range is6 ~30. Tset Tset Tamb. 6Min. 3Min. 6Min. Stop heating Original running state Start heating Compressor Outer fan Inner fan 2Min. Setting fan speed 2Min. Setting fan speed Reversal valve Conditions and processes of defrost Running Stop This unit adopt intelligent defrosting,it can defrost according to the frosting conditions,dual 8 display H Protection High Temp. Protection If it is detected that the evaporator tube temperature is too high, the outdoor fan will be stopped. When the tube temperature resumes to normal, the outdoor fan will be restarted. Noise Silencing Protection: If the unit is stopped by pressing ON/OFF, the reversal valve will be stopped after 2-minute lag; or 2 minutes will be delayed upon mode switching Fan mode Under FAN mode, only the indoor fan runs at setting speed. Compressor and outdoor fan motor stop running Auto Mode Under this mode, the system will automatically select its run mode (cool, dehumidify, heat or fan) with the change of ambient temperature. For protection function, same as under cooling and heating mode.

20 3.Other controls. Memory function Memory contents: Mode, up and down swing, Light, Setting temp., Setting fan speed, Ordinary setting Fahrenheit/Centigrade, after powered off, and powered on, it will run at the memory contents. If no timer setting function in last remote control order, the system will memorize the last remote control order, the system will memorize the last remote control order and work with last remote control setting. In the last remote control order, there is ordinary timer function, if power off happen beffore the timer arrived, the system will memorize the last remote control timer function, and will recalculate. If there is timer function in last remote control order, but timer has arrive, system will run at timer on or timer off and power off, after repowered on, the system will run at the mode before power off. Timer function.ordinary Timer setting: T imer on: Under unit off, the timer on function could be set up, if timer on has arrived, controller will run at setting mode, the timer interval is 0.5hr, setting range is hrs. Timer off: Under unit off, the timer off function could be set up, if timer off has arrived, controller will run at setting mode, the timer interval is 0.5hr, setting range is hrs. Timer setting for hour: Timer on: if system is running, to set timer on, the system will continue to run, if unit is off to set up timer on, when timer on has arrived, the system will run at pressetting mode. Timer off: If system is off to set up the timer off, when to set up timer off, the unit will stand by, when unit is on, to set up timer off, when the timer off arrived, the system will stop to work. Timer setting change: W hen system is in Timer status, can set up timer on and timer off by wireless remote control, to reset up Timer also, the system will run at last setting status. When system is running, at the same time to set up Timer on and Timer off, the system will keep the present setting status, when time arrived, system will stop to work. W hen system stop, at the same time to set up Timer on and Timer off, the system will stop, untile the timer arrived, the system will start to work. Hereafter, when timer of timer on in every day arrived, it will run the presetting modes, after timer off arrived, the system will stop. (3) Auto button After powered on, press this button, it will run at Auto mode, when repressed, the unit will turns off. (4) Buzzer The controller is powered on and detect the signal received, the buzzer will beep. (5) Sleep function Under cooling or dehumidifying mode, the preset temperature will automatically rise by, ine hour after setting of sleep program and rise by after 2hours. Under heating mode, the preset temperature will automatically decrease by program and decrease by another after 2hours. one hour after setting of sleep

21 (6) Turbo function The turbo function is available in Cool and Heat modes. (7) Dry function Dry function is available in Cool and Dehumidifying modes. (8) Auto fan speed control In this mode, indoor fan can run with Hig, Mid, Low speeds. (9) Up and down swing control After powered on, the lower swing motor will firstly rotate the guide louver to position 0, close up the air outlet vent; After unit turned on, if to set up swing function, when indoor fan stop running, the guide louver will stop at current position, inner fan motor is running, guide louver will resume to swing.from Cool, Dry, Fan modes to Heat mode, the guide louver will be opened at C position, when turn on swing will run at (A-D); from Heat mode to Cool, Dry, Fan mode, the fan louver will turn to B position, if turn on the swing, it will run at (A-D). (0) Displayer Running figure and mode figure display After powered on, the figure will be displayed, then only Power/running indicator turn on. When using remote conroller to open the unit, it will turn on, at the same time to display current setting running modes. Dual 8 display When the unit is turned on, after powered on, the nixie tube will display the setting temp.(setting range is 6-30 ). Under Auto mode, cooling and fan will display 25, heating will display 20, cooling only control display 25. LCD Display When cooling and dehumidifying, the Cool and indicator will turn on, when heating, the Heat and Run indicator will turn on, when in fan mode, the indicator will turn on. () PG motor lock protection When turn on the fan motor, if motor continuously run for a while and the running speed is very slow, in order to prevent motor automatically self-protection, it will stop running and display lock; If currently turns unit on, that dual 8 will display lock error code H6; If current is unit off, will not display the block error information.

22 Manual 2 of functions of remote controller This manual is applicable to 8K, 24K models, the centigrade is used for the following function manual, if there will be the Fahrenheit degree, that will be TF= TCX Temperature parameter The room setting temperature(tpreset) The room ambient temperature (Tamb) Basic Functions Once energized, the compressor should in no way be restarted unless after 3-minute time interval at least for the first energization, the compressor will be started without 3-minute lag. The compressor, once started, will not be stopped within 6 minutes with the charge of room temperature. Cooling Mode Cooling Conditions and Process When Tamb. Tpreset, the unit will run under cooling mode, in which case the compressor and outdoor fan will start and the indoor fan will run at setting speed. When Tamb. Tpreset, the compressor and the outdoor fan will stop, the indoor fan will run at setting speed. When Tpreset Tamb. Tpreset, the unit will maintain its original operating status. Under this mode, the four-way valve will not be powered on and the setting temperature range is The displayer displays running signal, cooling signal and setting temperature. Preset amb. Start cooling Original operating status Preset Compressor Outdoor fan Indoor fan min. min. min. Preset speed Stop cooling Run Stop Protection Antifreeze Protection If it is detected that the system is under antifreeze protection, the compressor and outdoor fan will be stopped, and the indoor fan will run at setting speed. When antifreeze protection is released and the compressor has stopped for 3 minutes, the unit will resume its original operating status. During antifreeze protection Compressor Outdoor fan Indoor fan 3 min. Preset speed Run Stop Over current protection If it is detected that the system amperage exceeds the specified value(about 22 A), the main unit will enter into the status that only the fan is running. After 3 minutes and overcurrent protection is released, the main unit will resume its original operating status.if it is 6 times continuously detected overcurrent protection (if the compressor has run over 6 mins continuously, the times of protection will be cleared),the main unit will be stopped on standby,the nixietube will display error code "E5", power indicator will blink and it is need to restart the unit by the wireless remote control. DRY Modes

23 DRY Modes When Tamb. Tpreset 2, the unit will run under DRY cooling mode, in which case the compressor and outdoor fan will be started and the indoor fan will run at low speed. When Tpreset 2 Tamb. Tpreset 2, the unit will run under Dry mode, in which case the indoor fan will keep run at low speed, the compressor and outdoor fan will be stopped after 6mins. After 4 minutes, the compressor and outdoor fan will be restarted. The dehumidifying process is so repeated in cycle. When Tamb. Tpreset 2, the compressor and outdoor fan will be stopped, the indoor fan will run at low speed. Under this mode, the switchover valve will not be powered on and the setting temperature range is Tpreset Tpreset Tamb. min. min. min. min. Start cooling Dehumidifying Stop running Compressor Outdoor fan Indoor fan Preset speed Run Stop Protection Antifreeze Protection Under dehumidifying and cooling mode, i f it is detected that the system is under antifreeze protection, the compressor and and outdoor fan will be stopped, and the indoor fan will run at low speed. When antifreeze protection is released and the the compressor has stopped for 3 minutes, the complete unit will resume its original operating status. Upon meeting "run 6 mins and stop 4 mins" dehumidify condition, if it is detected that the system is under antifreeze protection,the compressor and outdoor fan will be stopped, and the indoor fan will run at low speed. When antifreeze prote- Other protection ction is released and the compressor has stopped for 4 minutes, the complete unit will resume its original operating status. The other protections are the same with that under Cool mode. HEAT Mode (there is no this mode for cooling only unit) The conditions and process of heating When Tamb Tset 2,the system enters heating running, in this case, the reversal valve, compressor, outer fan enter simultaneously running.the indoor fan will delay at most for 2min to run. When Tamb Tset 4,the compressor and outdoor fan will stop, but the reversal valve is still with power on, the indoor unit will run at setting fan speed for 60s then will stop. When Tset 2 Tamb Tset 4,the unit will maintain its original operating status. Under this mode, the switchover valve will be powered on and the setting temperature range is Tpreset Tpreset Tamb. 6Min. 3Min. 6Min. Stop heating Original running state Start heating Compressor Outer fan Inner fan 2Min. Setting fan speed 2Min. Setting fan speed Inner fan Running Conditions and processes of defrost This unit adopt intelligent defrosting,it can defrost according to the frosting conditions,dual 8 display H Protection Anti-high temperature protection Stop

24 If it is detected that the evaporator tube temperature is too high, the outdoor fan will be stopped. When the tube temperature resumes to normal, the outdoor fan will be restarted. Noise Silencing Protection If the unit is stopped by pressing ON/OFF, the reversal valve will be stopped after 2-minute lag; or 2 minutes wi l l be delayed upon mode switching. Over current product The overcurrent protection is the same with the the over current protection under cool mode. Fan mode Under FA N mode, only the indoor fan runs at setting speed.the RUN indicator will be bright. Double 8 module indicator will display the setting temperature. When stand by, the power indicator is bright but the unit does not run. Auto Mode Under this mode, the system will automatically select its run mode (cool, dehumidify, heat or fan) with the change of ambient temperature. For protection function, same as under cooling and heating mode. Other controls Timer function Ordinary Timer setting: timer on: Under unit off, the timer on function could be set up, if timer on has arrived, controller will run at setting mode, the timer interval is 0.5hr, setting range is hrs. Timer off: Under unit off, the timer off function could be set up, if timer off has arrived, controller will run at setting mode, the timer interval is 0.5hr, setting range is hrs. Timer setting for hour: Timer on: if system is running, to set timer on, the system will continue to run, if unit is off to set up timer on, When timer on has arrived, the system will run at pressetting mode. Timer off: If system is off to set up the timer off, when to set up timer off, the unit will stand by, when unit is on, to set up timer off, when the timer off arrived, the system will stop to work. Timer setting change: When system is in Timer status, can set up timer on and timer off by wireless remote control, to reset up Timer also, the system will run at last setting status. When system is running, at the same time to set up Timer on and Timer off, the system will keep the present setting status, when time arrived, system will stop to work. When system stop, at the same time to set up Timer on and Timer off, the system will stop, untile the timer arrived, the system will start to work. Hereafter, when timer of timer on in every day arrived, it will run the presetting modes, after timer off arrived, the system will stop. Auto button After powered on, press this button, it will run at Auto mode, when repressed, the unit will turns off. Buzzer The controller is powered on and detect the signal received, the buzzer will beep. Sleep function Under cooling or dehumidifying mode, the preset temperature will automatically rise by, ine hour after setting of sleep program and rise by after 2hours. Preset temp. Tpreset Tpreset Tpreset Tpreset hour 2hours 2hours above Under heating mode, the preset temperature will automatically decrease by program and decrease by another after 2hours. one hour after setting of sleep

25 Tpreset Tpreset hr. 2hrs. 2hrs. above Tpreset temp. Tpreset Turbo function The turbo function is available in Cool and Heat modes. Dry function Dry function is available in Cool and Dehumidifying modes. Auto fan speed control In this mode, indoor fan can run with Hig, Mid, Low speeds. Up and down swing control After powered on, the lower swing motor will firstly rotate the guide louver to position 0, close up the air outlet vent; After unit turned on, if to set up swing function, when indoor fan stop running, the guide louver will stop at current position, inner fan motor is running, guide louver will resume to swing.from Cool, Dry, Fan modes to Heat mode, the guide louver will be opened at D position, when turn on swing will run at (A-D); from Heat mode to Cool, Dry, Fan mode, the fan louver will turn to B position, if turn on the swing, it will run at (A-C). When unit is turned off, the guide louver will turn to position 0, the swing is only available after preset the swing function, and indoor unit is running. Note: When to set up at position L to B, A to C, B to D, the guide louver will swing between position W to D. Displayer Running figure and mode figure display After powered on, the figure will be displayed, then only Power/running indicator turn on. When using remote conroller to open the unit, it will turn on, at the same time to display current setting running modes. Dual 8 display When the unit is turned on, after powered on, the nixie tube will display the setting temp.(setting range is 6-30 ). When the preset temperature display signal has been received, the nixie tube will display the preset temperature; If the display ambient temperature signal has been received, the nixie tube will display the current indoor ambient temperature, if to set up others by remote controller that the display will maintain its status. At displaying ambient temperature, the unit received the remote control signal, it will display 5s preset temperature then turn to ambient temperature display. The ambient temperature sensor malfunction will display F; Indoor tube sensor will display F2, wire jumper cap protection displays C5. PG motor lock protection When turn on the fan motor, if motor continuously run for a while and the running speed is very slow, in order to prevent motor automatically self-protection, it will stop running and display lock; If currently turns unit on, that dual 8 will display lock error code H6; If current is unit off, will not display the block error information. Power-off Memory Memory contents: Mode, UP/DOWN Swing, light, Set temp, Set fan speed. After de-energized, and re-energized, the unit will start to run with the memory function automatically. The system, if the last remote control signal do not set timer function, will memorize the last remote control signal and run according to it. If the last remote control signal has set timer function, the system is de-energized before the set time,when re-energized, the system will memorize the timer function, the set time will recalculate. If the last remote control signal has set timer function and the system is de-energized after the set time, when re-energized, the system will memorize the running status before de-energized.

26 7 Disassembly Procedures of Indoor Unit Operating Procedures / Photos Disassemble Front Panel Front Panel Pull open the front panel,lossen the clasp fixing on the front panel,then pull out the front panel Disassemble Filter Push the filter inward, and then pull it upward to remove it. Unscrew the screw fixing the top cover of electric box to remove the top cover. Filter Screw Cover of electric box Disassemble Guide Louver Manually bend the guide louver to loose the clasp at the guide louver. Remove the guide louver. Guide Louver Clasp

27 HUMMER Operating Procedures / Photos Clasp Disassemble Front Case Open the three screw covers at the front case, unscrew the three screws, pull open the clasp at the front case, and remove the front case. Screw Screw cover Front case Disassemble Electric Box Cover and indicator light panel Hold the electric box cover to press it inward so indicator light panel that the clasps on top loose and remove the electric box cover. Loosen one screw fising on the indicator light panel, Screw then pull out it. Electric Box Cover Clasp Disassemble Electric Box Remove the grounding wire of the evaporator. Remove the tube sensor. Disconnect the connecting cable of the indoor motor, use screwdriver to remove the screw fixing the electric box, and pull open the clasp at the side of the board of the indicator light. Take out the electric box. Grounding wire Screw

28 HUMMER Operating Procedures / Photos 7.Disassemble Water Tray Pull open the holding clasp on the left side of the water tray, disconnect the terminal of the stepping motor, lift and pull out the drainage pipe, and remove the water tray. Terminal Water Tray Clasp 8.Disassemble Evaporator Unscrew the screw to remove the rear pipe clamp. Remove the left and right screws at the evaporator, manually move the evaporator to loosen the clasp of its side plate from the groove. Carefully take out the evaporator and pay attention to protect the connecting pipe. Rear pipe clamp Screw Evaporator Screw

29 Operating Procedures / Photos Evaporator Screw 9.Disassemble Motor Unscrew the three screws fixing the motor clamp, and remove the motor clamp. Motor Clamp Loosen the holding nut at the shaft sleeve on the right side of the cross flow fan. Slightly lift and then pull out the motor. Screw Holding Screw Motor

30 Disassembly Procedures of Indoor Unit Operating Procedures / Photos.Disassemble Front Panel Pull open the front panel, take out the display window, then pull out the front panel along the groove (at the front case) fixing the front panel. Front Panel display window 2.Disassemble Filter Push the filter inward, and then pull it upward to remove it. Unscrew the screw fixing the top cover of electric box to remove the top cover. Filter 3.Disassemble Guide Louver Manually bend the guide louver to loose the clasp at the guide louver. Remove the guide louver. Guide Louver Clasp

31 Operating Procedures / Photos Clasp 4.Disassemble Front Case Open the three screw covers at the front case, unscrew the three screws, pull open the clasp at the front case, and remove the front case. Screw Screw cover Front case 5.Disassemble Electric Box Cover Hold the electric box cover to press it inward so that the clasps on top loose and remove the electric box cover. Electric Box Cover Clasp 6.Disassemble Electric Box Remove the grounding wire of the evaporator. Remove the tube sensor. Disconnect the connecting cable of the indoor motor, use screwdriver to remove the screw fixing the electric box, and pull open the clasp at the side of the board of the indicator light. Take out the electric box. Grounding wire Screw

32 HUMMER Operating Procedures / Photos Disassemble Water Tray Pull open the holding clasp on the left side of the water tray, disconnect the terminal of the stepping motor, lift and pull out the drainage pipe, and remove the water tray. Terminal Water Tray Clasp 8.Disassemble Evaporator Unscrew the screw to remove the rear pipe clamp. Remove the left and right screws at the evaporator, manually move the evaporator to loosen the clasp of its side plate from the groove. Carefully take out the evaporator and pay attention to protect the connecting pipe. Rear pipe clamp Screw Evaporator Screw 37

33 Operating Procedures / Photos Evaporator Screw 9.Disassemble Motor Unscrew the three screws fixing the motor clamp, and remove the motor clamp. Motor Clamp Loosen the holding nut at the shaft sleeve on the right side of the cross flow fan. Slightly lift and then pull out the motor. Screw Holding Screw Motor 38

34 HUMMER Operation procedures/pictures for outdoor uni(for 2K) Operating Procedures / Photos Top Cover Unscrew the screw fixing the handle,and then remove it upwards to take it out. Unscrew the 2 screws fixing left side of top cover and the screw fixing the right side to remove the top cover. Handle Unscrew the screws fixing the panel and turn right the front panel to remove it. Screws Unscrew the 2 screws fixing electric box,and then unscrew the 5 screws fixing the right side plate to remove it. Right Side Plate Screws

35 Operating Procedures / Photos Unscrew the screws fixing the electric box, and then pull out the inset block of lead-out wire of compressor and fan motor to take out the electric box. Screws Loosen the fastening nut fixing the axial flow fan with a spanner, and then take out the nut, spring gasket and flap gasket in turn. Nut Unscrew the 4 screws fixing the motor to take out the motor,and then unscrew the 2 screws fixing the motor support to take it out. Motor Motor Support

36 HUMMER Operating Procedures / Photos Unscrew the fastening nut of the four-way valve coil and remove the coil. Wrap the four-way valve with wet cotton and unsolder the 4 weld spots connecting the four-way valve to take it out. (Note: Refrigerant should be discharged firstly.) Welding process should be as quick as possible and keep wrapping cotton wet all the time. Be sure not to burn out the lead-out wire of compressor. Four-way Valve Respectively unsolder the weld spots of main capillary and auxiliary capillary to take off the capillary. Capillary Unscrew the three foot-nuts at the foot of the compressor. Unsolder the suction and the discharge pipes of the compressor,and then carefully remove the pipes to take out the compressor. Nut

37 Operation procedures/pictures for outdoor uni(for 2K) Operating Procedures / Photos Unscrew the screw fixing the big handle,and then remove it downwards to take it out. Screw Big Handle Unscrew the 2 screws fixing left side of top cover and the screw fixing the right side to remove the top cover. Screws Unscrew the 4 screws fixing the rear grill to remove it. Rear Grill Screws

38 HUMMER Operating Procedures / Photos Unscrew the 5 screws fixing the panel and dextrorotate the front panel to pull it out from groove. Screws Unscrew the 2 screws fixing electric box,and then unscrew the 5 screws fixing the right side plate to remove it. Screws Right Side Plate Screws Screw Unscrew the screws fixing the electric box, and then pull out the inset block of lead-out wire of compressor and fan motor to take out the electric box. Electric Box

39 Operating Procedures / Photos Loosen the fastening nut fixing the axial flow fan with a spanner, and then take out the nut, spring gasket and flap gasket in turn. Axial Flow Fan Nut Unscrew the 4 screws fixing the motor to take out the motor,and then unscrew the 2 screws fixing the motor support to take it out. Screws Motor Screws Unscrew the fastening nut of the four-way valve coil and remove the coil. Wrap the four-way valve with wet cotton and unsolder the 4 weld spots connecting the four-way valve to take it out. (Note: Refrigerant should be discharged firstly.) Welding process should be as quick as possible and keep wrapping cotton wet all the time. Be sure not to burn out the lead-out wire of compressor. Four-way valve Four-way valve coil Weld spots

40 HUMMER Operating Procedures / Photos Respectively unsolder the weld spots of main capillary and auxiliary capillary to take off the capillary. Capillary Unscrew the two bolts fixing gas valve and liquid valve.unsolder weld spots between gas valve and and air-return pipe to remove the gas valve. Unscrew the two bolts fixing liquid valve. Unsolder weld spots between liquid valve and capillary to remove the liquid valve. (Note:During unsoldering,wrap the valves with wet cloth to avoid damage for high temperature.) Liquid Valve Bolts Gas Valve Unscrew the three foot-nuts at the foot of the compressor. Unsolder the suction and the discharge pipes of the compressor,and then carefully remove the pipes to take out the compressor. Weld spots Nuts with washers

41 (8) Disassembly Procedures for Outdoor Unit Operating Procedures / Photos Unscrew the screw fixing the handle, then push it downwards to take it out. Unscrew the screws fixing the top cover, and then lift the top cover to remove it. Top Cover Screws Handle Screw Unscrew the screws fixing the front grill,and then lift it upwards to remove it. Front Grill Screws Unscrew the screws fixing the cabinet to remove it. Front side plate

42 HUMMER Operating Procedures / Photos Unscrew the 9 screws of the right side plate, then take down the right side plate. Right side plate unscrew the screw of electric box, pull out the Screw lead out insert of compressor, four-way valve and motor, then take down the electric box. Electric box cover Unsolder the pipeline connecting with valves ( to prevent soldering gun from burning out the chassis).unscrew 2 bolts fixing gas valve,and then unsolder the weld spot between pipeline and gas valve to remove gas valve. Unscrew the 2 bolts fixing liquid valve, and then unsolder the weld spots between pipeline and liquid valve to remove liquid valve. (Note:During unsoldering,wrap the valves with wet cloth to avoid damage for high temperature.) Liquid Valve Bolts Gas Valve

43 Operating Procedures / Photos Unscrew the nut fixing the fan with a spanner to take out the fan. Axial Flow Fan Nut Unscrew the screws fixing the motor support, and then lift it upwards to remove it. Unscrew the screws fixing the motor and pull out the connection line between it and electric box to remove it. Motor Terminal Screw of Motor Motor Support Screws Only for cooling and heating unit Unscrew the fixing nut of the four-way valve coil and remove the coil. Wrap the four-way valve with wet cotton and unsolder the 4 weld spots connecting the four-way valve to take it out. Welding process should be as quick as possible and keep wrapping cotton wet all the time. Be sure not to burn out the lead-out wire of compressor. Weld spots Four-way Valve

44 HUMMER Operating Procedures / Photos Unsolder the weld spots of capillary,valve and outlet pipe of condenser to remove the capillary. Prevent welding slag from blocking the capillary. Capillary Unsolder the pipeline connecting the compressor, and then unscrew the 3 foot-nuts fixing conpressor to remove it. Foot-nut

45 (24) Disassembly Procedures for Outdoor Unit Operating Procedures / Photos Top Cover Unscrew the screws fixing the top cover, and then lift the top cover to remove it. Unscrew the 3 screws fixing the front side plate to remove it. Screws Front Side Plate Unscrew the 4 screws fixing the rear grill to remove it. Rear Grill Unscrew the screws fixing the cabinet to remove it. Cabinet Screw

46 HUMMER Operating Procedures / Photos Unscrew the 2 screws fixing electric box to pull out the connection line between fan motor, compressor,four-way valve, and then lift the electric box to take it out. Electric box Screws Unscrew the screw of the right side plate, then take down the right side plate. Right side plate Unsolder the pipeline connecting with valves ( to prevent soldering gun from burning out the chassis). Unscrew 2 bolts fixing gas valve,and then unsolder the weld spot between pipeline and gas valve to remove gas valve. Unscrew the 2 bolts fixing liquid valve, and then unsolder the soldering spot between pipeline and liquid valve to remove liquid valve. (Note:During unsoldering,wrap the valves with wet cloth avoid damage for high temperature.) Liquid Valve Bolts Gas Valve

47 Operating Procedures / Photos Unscrew the nut fixing the fan with a spanner to take out the fan. Axial Flow Fan Nut Unscrew the screws fixing the motor support, and then lift it upwards to remove it. Unscrew the screws fixing the motor and pull out the connection line between it and electric box to remove it. Motor Terminal Screw of Motor Motor Support Screws Only for cooling and heating unit Unscrew the fixing nut of the four-way valve coil and remove the coil. Wrap the four-way valve with wet cotton and unsolder the 4 weld spots connecting the four-way valve to take it out. Welding process should be as quick as possible and keep wrapping cotton wet all the time. Be sure not to burn out the lead-out wire of compressor.

48 HUMMER Operating Procedures / Photos Unsolder the weld spots of capillary,valve and outlet tube of condenser to remove the capillary. Prevent welding slag from blocking the capillary. Capillary Unsolder the pipeline connecting the compressor, and then unscrew the 3 foot-nuts fixing conpressor to remove it. Foot-nut

49 8 Exploded View of Components and Parts of Indoor Unit

50 HUMMER Part Code No Description GWHN07EANK3AA/I GWHN09EANK3AA/I GWHN2EBNK3AA/I Qty Wall-Mounting Frame Rear Case assy Evaporator Pipe Cover Drainage Pipe Pipe Clamp Cross Flow Fan Fan Bearing Ring of Bearing Water Tray Cover Water Tray Connecting Lever Connecting Lever Manual Lever Evaporator Assy Evaporator Supporter Front Case Screw Cover Front Panel S S S 9 Filter Air Cleaner holder / / / / 2 Air Cleaner A / / / / 22 Guide Louver Remote Controller YKF Guide Louver Bearing Air Cleaner B / / / / 26 Tube Sensor Sensor Insert Swing Louver Stepping Motor Motor FN8G-PG Motor Clamp Wire Clip / / / / 33 Electric Box Cover Main Board Room Sensor Jumper Cap Fuse Power Cord Connecting Cable Terminal Board LED Board JD Transformer Electric Box Electric Box Cover S S S 45 Cable Clamp The above data are subject to be changed without notice.

51 Exploded View of Components and Parts of Indoor Unit

52 HUMMER No Description Part Code GWHN07EANK3A2A/I GWHN09EANK3A2A/I GWHN2EBNK3A2A/I Wall-Mounting Frame Rear Case assy Evaporator Pipe Cover Drainage Pipe Pipe Clamp Cross Flow Fan Fan Bearing Ring of Bearing Water Tray Cover Water Tray Connecting Lever Connecting Lever Manual Lever Evaporator Assy Evaporator Supporter Front Case Screw Cover Front Panel S S S 9 Filter Air Cleaner holder / / / / 2 Air Cleaner A / / / / 22 Guide Louver Remote Controller YKF Guide Louver Bearing Air Cleaner B / / / / 26 Tube Sensor Sensor Insert Swing Louver Stepping Motor MP24BA Motor FN8G-PG Motor Clamp Wire Clip / / / / 33 Electric Box Cover Main Board M504FJ Main Board M504F2J Room Sensor Jumper Cap Fuse Power Cord Connecting Cable Terminal Board LED Board DBL3A Transformer 4X26.5G Electric Box Electric Box Cover S S S 45 Cable Clamp Qty The above data are subject to be changed without notice.

53 Exploded View of Components and Parts of Indoor Unit

54 HUMMER No Description Part Code GWHN8EDNK3A2A/I Qty Wall-Mounting Frame Pipe clamp Hook Rear Case Evaporator Assy Cross Flow Fan Ring of Bearing Fan Bearing Left clamp of motor Drainage Pipe Water Tray Stepping Motor Gear Round Louver Connecting Lever Quadrate Louver Front Case Front Panel Filter(left) Filter(right) Remote control YKF display board DBL3A Screw Cover Guide Louver Guide Louver Motor MP24BA Right clamp of motor Bearing holder Motor FN20J-PG Electric Box Cover Covering plate Terminal board Electric box Main PCB M504F2NJ Transformer48X26J Wire clamp Rear clamp Power Cord Connecting Cable Signal Cable The above data are subject to be changed without notice.

55 Exploded View of Components and Parts of Indoor Unit

56 HUMMER No Description Qty Part Code GWHN24ECNK3A2A/I Wall-Mounting Frame Rear Case Fan Bearing Screw Cover Swing Louver Swing Link Swing Link Water Tray Guide Louver(up) Guide Louver(down) Cross Flow Fan Evaporator Assy Drainage Pipe Evaporator Support Filter Front Case Front Panel S 8 Remote Controller Displaying Light Board Electric Box Cover Wire Clamp Terminal Board T4B3A Electric Box Cover Main PCB Transformer Room Sensor 5k Tube Sensor 20k Sensor Insert Electric Box Lower Shield of Electric Box Upper Shield of Electric Box Stepping Motor MP35XX Motor Clamp Helicoid tongue Motor FN20C-PG Pipe Clamp Connecting Cable The above data are subject to be changed without notice.

GWHN07EANK3A1A GWHN09EANK3A1A

GWHN07EANK3A1A GWHN09EANK3A1A HUMMER GWHN07EANK3AA GWHN09EANK3AA GWHN07EANK3A2A GWHN09EANK3A2A HUMMER GWHN2EBNK3AA/I GWHN2EBNK3A2A/I GWHN2EBNK3AA GWHN2EBNK3A2A HUMMER Model Remarks 2 Model Function Rated Voltage Rated Frequency Total

More information

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0 Air Conditioner Service Manual 2 3 Model: AC-S13CG x 2 3 Content Technical specification.. 4 Performance curve.5 Outline & dimension of indoor unit..10 Outline & dimension of outdoor unit 11 Exploded view

More information

Split Type Inverter Room Air Conditioner

Split Type Inverter Room Air Conditioner Split Type Inverter Room Air Conditioner OPERATION MANUAL MODELS AY-X24LCJ AE-X24LCJ Thank you for choosing a SHARP air conditioner. Please read this manual thoroughly before using your air conditioner

More information

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM 11 5. EXPLOSION VIEW 12 6.

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM 11 5. EXPLOSION VIEW 12 6. TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE051220 Models TAC-09CHSA/GI TAC-12CHSA/GI CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM

More information

HYUNDAI SERVICE MANUAL HSH-I183NBE. Models WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS. No.TE121023

HYUNDAI SERVICE MANUAL HSH-I183NBE. Models WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS. No.TE121023 HYUNDAI WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE121023 Models HSH-I073NBE HSH-I123NBE HSH-I243NBE HSH-I093NBE HSH-I183NBE IMPORTANT NOTICE This service manual is intended for use by

More information

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER INDOOR UNIT AH-129 AH-MP14 OUTDOOR UNIT AU-129 AU-MP14 CONTENTS SPECIFICATIONS...2 EXTERNAL DIMENSIONS...4 WIRING DIAGRAMS...5 ELECTRICAL PARTS...6 MICROCOMPUTER

More information

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM 13 5. EXPLOSION VIEW 16 6

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM 13 5. EXPLOSION VIEW 16 6 TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE080528 Models KFTHP-12 KFTHP-18 KFTHP-24 CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL

More information

Technical Service Manual. for 13SEER Comfortstar Plus Air Conditioners

Technical Service Manual. for 13SEER Comfortstar Plus Air Conditioners Comfortstar Plus Introduction and features Technical Service Manual for 13SEER Comfortstar Plus Air Conditioners Model Remarks CHH024CD-13 Models & specifications Model CHH024CD-13 Function Cooling & Heating

More information

Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Service manual. Website: www.andico.com.au CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. Website: www.andico.com.au Service manual CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL. - ONLY FOR AUTHORISED SERVICE PERSONNEL. MODELS: MPK1-09CR-QB8 MPK1-12ER-QB6

More information

Marine Air Conditioners Service Manual

Marine Air Conditioners Service Manual GREE COMMERCIAL AIR CONDITION MARINE AIR CONDITIONERS Marine Air Conditioners Service Manual GREE ELECTRIC APPLIANCES INC. OF ZHUHAI 1 GREE COMMERCIAL AIR CONDITION MARINE AIR CONDITIONERS CONTENTS PRODUCT...2

More information

Split Type Inverter Room Air Conditioner OPERATION MANUAL

Split Type Inverter Room Air Conditioner OPERATION MANUAL Split Type Inverter Room Air Conditioner OPERATION MANUAL MODELS: AY-X09NCJ AE-X09NCJ AY-X12NCJ AE-X12NCJ AY-X18NCJ AE-X18NCJ AY-X24NCJ AE-X24NCJ AY-X28NCJ AE-X28NCJ Thank you for selecting SHARP Air-Conditioner.

More information

Technical Service Manual. Version One

Technical Service Manual. Version One [Gree Central Air Conditioner] Technical Service Manual Ducted type unit 2.3KW-16KW Version One GREE ELECTRIC APPLIANCES.INC.OF ZHUHAI - 1 - FG Series wind pipe blowing air-conditioning unit Section One:

More information

york air-conditioning products Residential & VRF News 2015

york air-conditioning products Residential & VRF News 2015 york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter

More information

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2 SERVICE MANUAL Room Air Conditioner Multi Split Wall-Mounted Type Indoor FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2 NOTE: Before servicing the unit, please read this at first. Always contact with

More information

ChapterⅠ Introduction to Products

ChapterⅠ Introduction to Products AI RCONDI TI ONI NG SYSTEMS Model s : UMATCH I NVERTER Ser vi cemanual Ser vi cemanual ChapterⅠ Introduction to Products 1. Kinds of Products Universal outdoor unit Duct type Floor ceiling type Cassette

More information

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 79G SA 99G FILE NO. SA 79G SA 99G REFERENCE NO. SM700402

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 79G SA 99G FILE NO. SA 79G SA 99G REFERENCE NO. SM700402 TECHNICAL & SERVICE MANUAL SA 79G SA 99G FILE NO. WINDOW TYPE AIR CONDITIONER Model No. Product Code No. Destination SA-79G-A 1 851 005 18 General (50Hz) & Europe SA-99G-A 1 851 005 19 SA 79G SA 99G REFERENCE

More information

Technical service manual 2009

Technical service manual 2009 MULTI SPLIT TYPE, HEAT PUMP AIR CONDITIONERS Technical service manual 2009 KSIM MULTI ZONE SERIES R410A DC Inverter multi Series Models KSIM20912-H216 KSIM30912-H216 KSIM40912-H216 CONTENT 1. Product features

More information

Appendix - Controllers 179

Appendix - Controllers 179 Version: 200703 Appendix - Controllers 179 -3- -4- -5- -6- -7- -8- 2. Specifications 2.1 Specifications for inverter units item Model AB182ACERA Function cooling heating Capacity kw 5.01.8--5.8 5.22.0---6.2

More information

Portable Air Conditioner

Portable Air Conditioner Portable Air Conditioner Owner's Manual Model:3 in 1 12,000 Btu/h Series 3 Please read this owner s manual carefully before operation and retain it for future reference. CONTENTS 1. SUMMARY...1 2. PORTABLE

More information

High Wall EVHC 09 to 12 DSAAAR

High Wall EVHC 09 to 12 DSAAAR High Wall EVHC 09 to 12 DSAAAR SERVICE MAUAL EVHC-09 / EVHC-12 SM-EVHC-D-09-12GB 05-10 121 COTETS Safety Cautions...1 Operation of wireless remote control...4 Emergency operation...9 Product Specifications...10

More information

How To Power A Car With A Fan And A Fan (Power)

How To Power A Car With A Fan And A Fan (Power) SPLIT TYPE ROO AIR CONDITIONER CEILING WALL TYPE INVERTER Indoor unit AWYZLBC AWYZLBC AWYZLBC AWYZLBC Outdoor unit AOYZLBC AOYZLBL AOYZLBC AOYZLBL CONTENTS SPECIFICATIONS................... OUTLINE AND

More information

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/ SERVICE MANUAL Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/ FS2MI-147HFD FS2MI-187HFD FS3MI-217HFD FS3MI-277HFD FS4MI-277HFD FS4MI-367HFD FS5MI-367HFD NOTE: Before servicing the

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASYG07LECA ASYG09LECA ASYG12LECA ASYG14LECA AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC R410A CONTENTS

More information

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05 TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation

More information

Wall Mounted Mini Split Heat Pump Air Conditioner

Wall Mounted Mini Split Heat Pump Air Conditioner Wall Mounted Mini Split Heat Pump Air Conditioner OPERATING AND INSTALLATION MANUAL Model: KFIHP-09-ID / KFHIP-09-OD KFHHP-12-ID / KFHHP-12-OD Indoor Unit. Outdoor Unit. Thank you for selecting Soleus

More information

Heat Pump Water Heater IOM Manual

Heat Pump Water Heater IOM Manual Heat Pump Water Heater IOM Manual Installation Operation & Maintenance This manual is intended as an aid to qualified service personnel for proper installation, operation and maintenance of the heat pump

More information

SERVICE MANUAL. Domestic Air Conditioner. Model. Feature HW-05LN03

SERVICE MANUAL. Domestic Air Conditioner. Model. Feature HW-05LN03 Domestic Air Conditioner SERVICE MANUAL Model HW-05LN03 Feature Anti-mold filter Mechanical control Easy clean filters Slide chassis 4-way airflow direction 2 cool settings, 2 fan settings Serial Number:

More information

DUCT TYPE SPLIT AIR CONDITIONER SERVICE MANUAL. T1/R410A/50Hz (GC201303- )

DUCT TYPE SPLIT AIR CONDITIONER SERVICE MANUAL. T1/R410A/50Hz (GC201303- ) DUCT TYPE SPLIT AIR CDITIER SERVICE MANUAL T1/R410A/50Hz (GC201303- ) CTENTS PRODUCT...2 1 MODELS LIST... 2 2 NOMENCLATURE... 3 3 FUNCTI... 4 3.1 Features-outdoor units...4 3.2 Features-indoor units...4

More information

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS ELECTRICAL SAFETY This appliance is for indoor use only. Always turn off the unit and unplug

More information

Split Air Conditioner

Split Air Conditioner Split nditioner plit itsplit ir onditioner Split Split Split Split Split User s WNER'S 'S ER'S For s: AWI/AWO-21HPR1 Delta AWI/AWO-25HPR1 Delta AWI/AWO-32HPR1 Delta AWI/AWO-53HPR1 Delta AWI/AWO-65HPR1

More information

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI

SERVICE INSTRUCTION R410A. SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER Universal Floor / Ceiling Duct / Cassette Wall Mounted / Floor type INVERTER MULTI R410A Models Indoor unit Outdoor unit AB*14LBAJ AB*18LBAJ AB*F14LAT

More information

Failure code manual. content

Failure code manual. content Failure code manual content 一 wall split AC series 2 二 floor standing AC series. 4 三 portable AC series.. 5 四 dehumidifer 6 五 DC inverter single split series...7 六 DC inverter multi-split series 10 1 一

More information

14. Troubleshooting Guide

14. Troubleshooting Guide 14. Guide 14.1 Refrigeration Cycle System In order to diagnose malfunctions, ensure the air conditioner is free from electrical problems before inspecting the refrigeration cycle. Such problems include

More information

SWIMMING POOL HEAT PUMP Owners Manual

SWIMMING POOL HEAT PUMP Owners Manual SWIMMING POOL HEAT PUMP Owners Manual This manual refers to the 17.0kw and 21.0kw models only. The heat pump unit is sold with a 1 year warranty. In addition there is a 2 year parts warranty on the compressor

More information

Change for Life. Service Manual

Change for Life. Service Manual Change for Life Service Manual MODELS: GWH09RB-K3DNA2C(CB301001100) GWH09RB-K3DNA2C(CB301001102) GWH09RB-K3DNA3C(CB302000900) GWH09RB-K3DNA3C(CB302000901) GWH09RB-K3DNA5C(CB304000500) GWH09RB-K3DNA6C(CB305000100)

More information

INSTALLATION INSTRUCTIONS AIRCOMMAND IBIS ROOFTOP AIRCONDITIONER

INSTALLATION INSTRUCTIONS AIRCOMMAND IBIS ROOFTOP AIRCONDITIONER \ INSTALLATION INSTRUCTIONS AIRCOMMAND IBIS ROOFTOP AIRCONDITIONER Suitability: The IBIS caravan rooftop aircondioner is suitable for installation on caravans and motorhomes provided the roof structure

More information

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW AOU12RLFW AOU15RLS SERVICE INSTRUCTION SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTEDtype INVERTER Models Indoor unit Outdoor unit ASU 9RLF ASURLF ASU5RLS AOU 9RLFW AOURLFW AOU5RLS R40A CONTENTS. DESCRIPTION OF EACH CONTROL

More information

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty Codes Room Air Conditioner range: Indoor unit alarm s If timer lamp flashes for 1 second on, 1 second off, this indicates pre heating on the coil during heating mode and is not an error. If timer lamp

More information

WALL MOUNTED SPLIT TYPE AIR CONDITIONER

WALL MOUNTED SPLIT TYPE AIR CONDITIONER WALL MOUNTED SPLIT TYPE AIR CONDITIONER MANUAL 8 OM-G12-ACSON CONTENTS - Operating Guide page 1 - G12 Remote Controller Indication page 2 - Indicator Lights page 4 - Installation of Aroma page 5 - Auto

More information

AIR CONDITIONER INSTALLATION MANUAL

AIR CONDITIONER INSTALLATION MANUAL INSTALLATION MANUAL AIR CONDITIONER Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by

More information

HP switch LP switch Discharge thermo Comp. Surface thermo

HP switch LP switch Discharge thermo Comp. Surface thermo 1 Specifications Zubadan Model Name PUHZ-SHW80VHA PUHZ-SHW11VHA PUHZ-SHW11YHA Power supply (phase, cycle, voltage) 1φ, V, Hz 1φ, V, Hz 3φ, 0V, Hz Max. current A 9.5 35.0 13.0 Breaker size A 3 16 Outer

More information

evo+ Installation, Service & Troubleshooting DUCTLESS SYSTEM

evo+ Installation, Service & Troubleshooting DUCTLESS SYSTEM evo+ DUCTLESS SYSTEM Installation, Service & Troubleshooting Models: GWH09AB-A3DNA2B GWH12AB-A3DNA2B GWH09AB-D3DNA2D GWH12AB-D3DNA2D GWH18AB-D3DNA2D GWH24AB-D3DNA2D Table of Contents Safety Precautions

More information

USER S MANUAL HSC-24A

USER S MANUAL HSC-24A AIRREX AIR CONDITIONER USER S MANUAL HSC-24A Thank you for purchasing an AIRREX AIR CONDITIONER. BEFORE operation please read this user s manual carefully. Keep this manual readily available. It is ESSENTIAL

More information

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA USER S MANUAL FH052EAV1 FH070EAV1 E HNIKA PORTUGUÊS ENGLISH ESPAÑOL ITALIANO DEUTSCH FRANÇAIS System Air Conditioner (Cooling and Heating) E S F I P D G DB98-29263A(1) Safety Precautions Register your

More information

U-MATCH Air Conditioners. Service Manual. T1/R410a/50Hz

U-MATCH Air Conditioners. Service Manual. T1/R410a/50Hz U-MATCH Air Conditioners Service Manual T1/R410a/50Hz GREE ELECTRIC APPLIANCES INC. OF ZHUHAI 1 CONTENTS PRODUCT...2 1 MODELS LIST...2 1.1 Outdoor Unit...2 1.2 Indoor Unit...3 2 NOMENCLATURE...4 3 FUNCTION...5

More information

The figures in this manual may be different with the material objects, please refer to the material objects for reference.

The figures in this manual may be different with the material objects, please refer to the material objects for reference. CONTENTS Operation and maintenance Notices for operation Notices for use Names and functions of each part Operation of wireless remote control Emergency operation Clean and care Troubleshooting Installation

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL SAP-KRV9AEH + SAP-CRV9AEH SAP-KRV12AEH + SAP-CRV12AEH FILE NO. Destination: Europe DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. SAP-KRV9AEH SAP-KRV12AEH Product

More information

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t

More information

SERVICE MANUAL MUZ-GE09NA MUZ-GE12NA MUZ-GE15NA MUZ-GE18NA MUZ-GE24NA MUY-GE09NA MUY-GE12NA MUY-GE15NA MUY-GE18NA MUY-GE24NA OUTDOOR UNIT

SERVICE MANUAL MUZ-GE09NA MUZ-GE12NA MUZ-GE15NA MUZ-GE18NA MUZ-GE24NA MUY-GE09NA MUY-GE12NA MUY-GE15NA MUY-GE18NA MUY-GE24NA OUTDOOR UNIT SPLIT-TYPE AIR CONDITIONERS Revision B: Descriptions regarding the outdoor fan motor have been corrected. Please void OBH549 REVISED EDITION-A. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH549 REVISED

More information

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact: 7610.478.16 8/99 INSTRUCTION MANUAL Models 8005, 8010, 8015 For Sales & Service please contact: CENTRAIR Air Systems & Supplies Phone: 705-722-5747 Fax: 705-722-5458 Email: sales@centrair.ca Website: www.centrair.ca

More information

2 NOMENCLATURE 3 FUNCTION 4 PRODUCT DATA

2 NOMENCLATURE 3 FUNCTION 4 PRODUCT DATA CONTENTS PRODUCT... 2 1 MODELS LIST... 2 1.1 Outdoor Unit... 2 1.2 Indoor Unit... 3 2 NOMENCLATURE... 4 3 FUNCTION... 4 4 PRODUCT DATA... 5 4.1 Product Data at Rated Condition... 6 4.2 Operation Range...

More information

MDT5N25 & MTD5N40 SERVICE PARTS

MDT5N25 & MTD5N40 SERVICE PARTS MDTN & MTDN0 SERVICE PARTS This parts list contains the service parts and wiring diagrams for this model. Check the model number of the machine requiring the parts to be sure that this is the correct parts

More information

PANASONIC TROUBLE SHOOTING GUIDE

PANASONIC TROUBLE SHOOTING GUIDE A General Guide To Room Style Products Pipework Pipe sizes and lengths should be as the relevant Technical Guide Both lines should be insulated No line accessories or oil traps should be fitted In cooling

More information

SiUS091133. Service Manual. Inverter Pair FTXS-L Series FDXS-L Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

SiUS091133. Service Manual. Inverter Pair FTXS-L Series FDXS-L Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Service Manual Inverter Pair FTXS-L Series FDXS-L Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair FTXS-L Series FDXS-L Series Cooling Only Indoor Unit FTXS30LVJU

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL CSKE1NB41 & CZ18BT1U + CUKE1NK1 CSKE18NB4UW & CZ18BT1U + CUKE18NKU DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Body (Panel) CSKE1NB41 (CZ18BT1U) CSKE18NB4UW (CZ18BT1U)

More information

Split Air Conditioner

Split Air Conditioner Split Air Conditioner Thank you for choosing our product. For proper operation, please read and keep this manual carefully. If you have lost the Owner s Manual, please contact the local agent or visit

More information

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1 SPLIT-TYPE AIR CONDITIONERS Revision A: MUZ-GE42/50VA(H) - E1 has been added. Please void OBH516. OUTDOOR UNIT SERVICE MANUAL HFC utilized R410A. OBH516 REVISED EDITION-A Models MUZ-GE25VA - E1 MUZ-GE25VAH

More information

OWNER S MANUAL VMH 09/12/18/27/36 InverterFlex

OWNER S MANUAL VMH 09/12/18/27/36 InverterFlex OWNER S MANUAL VMH 09/12/18/27/36 InverterFlex Version C Single, Dual, Tri or Quad Zone Ductless Mini-Split System Heat Controller, Inc. 1900 Wellworth Ave. Jackson, MI 49203 (517)787-2100 www.heatcontroller.com

More information

Service Manual. MODEL: GWC09KF-K3DNA5A GWH09KF-K3DNA5A GWC12KF-K3DNA5A GWH12KF-K3DNA5A (Refrigerant R-410A) GREE ELECTRIC APPLIANCES,INC.

Service Manual. MODEL: GWC09KF-K3DNA5A GWH09KF-K3DNA5A GWC12KF-K3DNA5A GWH12KF-K3DNA5A (Refrigerant R-410A) GREE ELECTRIC APPLIANCES,INC. Service Manual MODEL: GWC09KF-K3DNA5A GWH09KF-K3DNA5A GWC12KF-K3DNA5A GWH12KF-K3DNA5A (Refrigerant R-410A) GREE ELECTRIC APPLIANCES,INC.OF ZHUHAI Summary and features Summary and features Indoor Unit GWC09KF-K3DNA5A/I

More information

SERVICE MANUAL REFRIGERATION

SERVICE MANUAL REFRIGERATION SERVICE MANUAL REFRIGERATION ELECTROLUX HOME PRODUCTS S.p.A. Publication no. Spares Operations Italy 599 36 16-90 Corso Lino Zanussi, 30 031117 I - 33080 PORCIA / PN (ITALY) ITZ/SERVICE/AA Fax +39 0434

More information

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC Portable Evaporative Air Cooler OWNER S MANUAL Read and save these instructions before use Model: CL30XC Power rating: 250 Watts Voltage rating: 230 Volt, 50Hz Made in P.R.C. QUICK START GUIDE Fill with

More information

WINDOW ROOM AIR CONDITIONER

WINDOW ROOM AIR CONDITIONER WINDOW ROOM AIR CONDITIONER Installation and Operation Manual Electromechanical Remote Control CAPACITIES 220V - 60 HZ. 12,000; 18,000; 24000 BTU/HR 220V-240V - 50 HZ. 12,000; 18,000; 24000 BTU/HR Please

More information

IH 17025 E Sigma Island 90

IH 17025 E Sigma Island 90 INSTRUCTIONS FOR USE Kitchen extractor hood Type: IH 17025 E Sigma Island 90 Dear Customer!! You are now a user of the newest generation kitchen extractor hood type IH 17025 E Sigma Island 90. This hood

More information

Wall Mounted Unit Owner s Manual

Wall Mounted Unit Owner s Manual Models E2VI-09/E2VO-09 E2VI-12/E2VO-12 E2VI-18/E2VO-18 E2VI-24/E2VO-24 Wall Mounted Unit Owner s Manual Thank you for choosing INVENTOR air conditioning system. For correct use of this unit, please read

More information

HVAC SYSTEM (HEATER, VENTILATOR, AND A/C)

HVAC SYSTEM (HEATER, VENTILATOR, AND A/C) HVAC SYSTEM (HEATER, VENTILATOR, AND A/C) HEATER SYSTEM 1. Heater System A: GENERAL A semi-center type integrated air conditioning unit is used, where a high performance heater core and an evaporator core

More information

Split Air Conditioner User Manual BK 2600 BK 3500

Split Air Conditioner User Manual BK 2600 BK 3500 Split Air Conditioner User Manual BK 2600 BK 3500 1 l- Notices for operation If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly qualified person

More information

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved Sanyo Section : Section : Section : Section : Section : sip Modbus Guide Configuration Modbus Table Technical Specification Pinouts, Cable Connections & Wiring Alarm Fault Codes Issue : February 009 Section

More information

Service manual. Room air conditioner Split Wall-Mounted Type GC/CU-S05CR GC/CU-S07HR GC/CU-S09HR GC/CU-S12HR GC/CU-S18HR

Service manual. Room air conditioner Split Wall-Mounted Type GC/CU-S05CR GC/CU-S07HR GC/CU-S09HR GC/CU-S12HR GC/CU-S18HR Service manual Room air conditioner Split Wall-Mounted Type GC/CU-S05CR GC/CU-S07HR GC/CU-S09HR GC/CU-S12HR GC/CU-S18HR Climatic Control Corporation Wall-Mounted Split Type Content 1. Precaution 1 1.1

More information

9ASNA-A1-1202 SERVICE MANUAL SENVILLE AIRCONDITIONER DC INVERTER SPLIT WALL-MOUNTED TYPE

9ASNA-A1-1202 SERVICE MANUAL SENVILLE AIRCONDITIONER DC INVERTER SPLIT WALL-MOUNTED TYPE 9ASNA-A1-1202 SERVICE MANUAL SENVILLE AIRCONDITIONER DC INVERTER SPLIT WALL-MOUNTED TYPE CONTENTS 1. Precaution... 1 1.1 Safety Precaution... 1 1.2 Warning... 1 2. Function... 6 3. Dimension... 9 3.1 Indoor

More information

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

Gree Solar Hybrid Hi Wall Inverter Air Conditioner Gree Solar Hybrid Hi Wall Inverter Air Conditioner Utilize the natural power of the sun to heat or cool your home. Find out more at www.greeonline.com Why Choose a Solar Hybrid Inverter? The new Gree Solar

More information

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español Split-type Air-Conditioner MXZ-3A30NA MXZ-4A36NA INSTALLATION MANUAL Refer to the installation manual of each indoor unit for indoor unit installation. English Français Español ATTENTION This manual mentions

More information

SiUS041111. Service Manual. Inverter Pair Wall Mounted Type K-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

SiUS041111. Service Manual. Inverter Pair Wall Mounted Type K-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Service Manual Inverter Pair Wall Mounted Type K-Series [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump Inverter Pair Wall Mounted Type K-Series Cooling Only Indoor Unit FTXN09KEVJU

More information

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan TABLE OF CONTENTS INTRODUCTION 2 IMPORTANT SAFEGUARDS...2 PACKAGE CONTAINS..2 NAMES OF PARTS.3

More information

FULL DC INVERTER SYSTEMS

FULL DC INVERTER SYSTEMS FULL DC INVERTER SYSTEMS INDIDUAL AND MODULAR DESIGN & FLEXIBLE COMBINATION commercial air conditioners SDV4 2011/2012 AIR CONDITIONING 1 WELCOME TO THE WORLD of SINCLAIR AIR CONDITIONERS Company operation

More information

SiBE12-625. D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump

SiBE12-625. D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump SiBE12-625 D-Series / E-Series [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump SUPER MULTI NX D-Series / E-Series Cooling Only Indoor Unit FTKS20D3VMW FTKS20CAVMB FDKS25CAVMB

More information

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

New Deluxe Wall Mounted Heat Pump Series EXTERIOS New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS

NO-FROST CUSTOMER SUPPORT INFORMATION INFORMATION ON THE NO-FROST TECHNOLOGY WHITE GOODS INFORMATION INFORMATION ON THE TECHNOLOGY The -Frost refrigerators are different from the other static refrigerators in terms of their operational system. In normal refrigerators, in the freezing section,the

More information

Split air conditioner Wall mounted Type Service manual

Split air conditioner Wall mounted Type Service manual Split air conditioner Wall mounted Type Service manual AUS-07C(H)53R010Lx AUS-07C(H)53R150Lx AUS-09C(H)53R150Lx AUS-09C(H)53R010Lx AUS-12C(H)53R150Lx AUS-12C(H)53R130Lx (X=1,2,3,4,5,6,14,15,16,...) CONTENTS

More information

Room Air Conditioners

Room Air Conditioners Installation and Operation Manual Room Air Conditioners Portable Range ECO8P Register your air conditioner Model information can be found on the CE label. Please register your product online at www.ecoair.org.

More information

Taurus Series YORK Window Air Conditioners

Taurus Series YORK Window Air Conditioners Taurus Series YORK Window Air Conditioners IOM IOWRCAG50220711A1 Warning 1. Before using the Air conditioner please read the instructions carefully. They contain important advise about the installation,

More information

Heat Pump Product Brochure 2015/2016. Premier Series Hi-Wall Split Systems. Everyday Comfort

Heat Pump Product Brochure 2015/2016. Premier Series Hi-Wall Split Systems. Everyday Comfort Heat Pump Product Brochure 2015/2016 Premier Series Hi-Wall Split Systems Everyday Comfort Everyday Innovation We design with you in mind. You ll find that Haier Heat Pump units are quiet, efficient and

More information

Wall Mounted Mini Split Heat Pump Air Conditioner

Wall Mounted Mini Split Heat Pump Air Conditioner Wall Mounted Mini Split Heat Pump Air Conditioner OPERATING AND INSTALLATION MANUAL Model: KFHHP-18-ID / KFHHP-18-OD Indoor Unit. Outdoor Unit. Thank you for selecting Soleus Air. To ensure proper operation,

More information

CS-XE9EKE CU-XE9EKE CS-XE12EKE CU-XE12EKE

CS-XE9EKE CU-XE9EKE CS-XE12EKE CU-XE12EKE Order No. MAC0512111C8 Air Conditioner CS-XE9EKE CU-XE9EKE CS-XE12EKE CU-XE12EKE TABLE OF CONTENTS PAGE 1 Safety Precautions----------------------------------------------- 3 2 Specifications -----------------------------------------------------

More information

Use and Care Manual. Model CPA12KH AIR CONDITIONER

Use and Care Manual. Model CPA12KH AIR CONDITIONER Use and Care Manual Model CPA12KH AIR CONDITIONER Introduction Thank you for choosing this air conditioner to provide you and your family with all of the "Home Comfort" requirements for your home, cottage

More information

*.ppt 11/2/2009 12:48 PM 1

*.ppt 11/2/2009 12:48 PM 1 Digital Compressor Controller *.ppt 11/2/2009 12:48 PM 1 Copeland Scroll Digital Controller Simple Controller That Enables OEM s To Use Digital Scrolls Relieves OEM From Developing Special Controllers

More information

Split Air Conditioner

Split Air Conditioner Split Air Conditioner C OWNER'S MANUAL ALPICAIR AIR CONDITIONERS Thank you for choosing AlpicAir air conditioner for correct operation, please read this owner's manual carefully before operating the unit

More information

Operation Manual of The Ducted Split Type Air-Conditioning Units

Operation Manual of The Ducted Split Type Air-Conditioning Units Operation Manual of The Ducted Split Type Air-Conditioning Units FSL-1100B-H-3F FSOL-1100B-3F Please read this manual carefully before operation and installation Preface FISHER ducted air-conditioning

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W MODE ALARM Portable Air Conditioner OWNER S MANUAL Read these instructions before use 8 Model: MF08CESWW Voltage rating: 115V~60Hz Power rating : 800W Customer Support : 1-800-474-2147 For product inquiries

More information

PORTABLE AIR CONDITIONER

PORTABLE AIR CONDITIONER VERY IMPORTANT! MODEL: GDC-AC9RW / GDC-AC9RCS GDC-AC9RCW / GDC-AC12RW GDC-AC12RB / GDC-AC12RCB GDC-AC12RCW INSTRUCTIONS FOR USE PORTABLE AIR CONDITIONER Do not install and use your portable air conditioner

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CHCSCS Voltage rating: 120V~60Hz Power rating : 1400W(Cooling) Power rating : 1350W(Heating) Customer Support : 1-800-474-21477

More information

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER TECHNICAL & SERVICE MANUAL CSKS12NB41 & CZ18BT1U + CUKS12NK1A CSKS18NB4UW & CZ18BT1U + CUKS18NKU CSKS18NB4UW & CZ18BT1U + CUKS18NKUA DC INVERTER SPLIT SYSTEM AIR CONDITIONER Indoor Model No. Body (Panel)

More information

PORTABLE AIR CONDITIONER

PORTABLE AIR CONDITIONER PORTABLE AIR CONDITIONER MAC 7500 Owner s Manual Air Conditioner Dehumidifier Oscillating Fan Please read this owner s manual carefully before operating the unit. POWERED BY 66126113.p65 17 INTRODUCTION

More information

INSTALLATION MANUAL. Address card EKAC10B

INSTALLATION MANUAL. Address card EKAC10B INSTALLATION MANUAL 88 44 µchiller compact 70 64 4a 4b G G0 power supply G G0 power supply 50 5 50 5 4a 4b 5a 5b 4 5a 5b Installation manual READ THIS MANUAL ATTENTIVELY BEFORE STARTING UP THE UNIT. DO

More information

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER + SAP C181MA + SAP C181GA + SAP C181BA + SAP C241MA + SAP C241BA FILE NO.

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER + SAP C181MA + SAP C181GA + SAP C181BA + SAP C241MA + SAP C241BA FILE NO. TECHNICAL & SERVICE MANUAL SAP K161GJA SAP K181GJA SAP K181MBA SAP K241GJA SAP K241MBA + SAP C161GA + SAP C161JA + SAP C181GA + SAP C181JA + SAP C181MA + SAP C181BA + SAP C241GA + SAP C241JA + SAP C241MA

More information

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS Céliera Corporation. All rights reserved. Unauthorized duplication, reproduction prohibited. CONTENTS SAFETY PRECAUTIONS...

More information

Split air conditioner Wall mounted Type Service manual. AUS-07H53R010Px AUS-09H53R010Px AUS-09H53R150Px AUS-12H53R130Px AUS-12H53R150Px (X=1,2,3,...

Split air conditioner Wall mounted Type Service manual. AUS-07H53R010Px AUS-09H53R010Px AUS-09H53R150Px AUS-12H53R130Px AUS-12H53R150Px (X=1,2,3,... Split air conditioner Wall mounted Type Service manual AUS-07H53R010Px AUS-09H53R010Px AUS-09H53R150Px AUS-12H53R130Px AUS-12H53R150Px (X=1,2,3,...) CONTENTS Contents Safety precautions Installation Block

More information

ALL IN ONE. Heat Pump Water Heater

ALL IN ONE. Heat Pump Water Heater ALL IN ONE Heat Pump Water Heater INSTALLATION AND OPERATION INSTRUCTIONS Please read this user s manual carefully before operate the unit. www.airtradecentre.com CONTENTS A. IMPORTANT REMARKS ------------------------------------------------------------------------------------------------

More information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W Portable Air Conditioner OWNER S MANUAL Read these instructions before use Model: MM14CCS Customer Support : 1-800-474-2147 Voltage rating: 115V~60Hz Power rating : 1400W For product inquiries or support

More information

WE-350 Series ¼ Turn Electric Actuator

WE-350 Series ¼ Turn Electric Actuator WE-350 Series ¼ Turn Electric Actuator Operation and Installation Manual Pg 1 (Rev. 020113) Table of Contents 1.0 General 1.1 Pre-Installation Inspection 1.2 Storage 1.3 Features & General Information

More information