Stratomaster Smart Single



Similar documents
SECURITY SYSTEM ADP-CAN

MGL Avionics CAN bus interface for Trig Avionics TT21/TT22 transponders

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

MTX-D Ethanol Content and Fuel Temperature Gauge User Manual

MTX-D, Oil Temperature/Pressure Gauge

NL708 (XWA11V) Walk-In Temp / Door /Alarm / Light Module

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

i ChatterBox! Motorcycle Security

Multi-Range Programmable DC Power Supplies 9115 Series

Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.

1993 ACCESSORIES & EQUIPMENT Volkswagen Instrument Panels. Volkswagen; EuroVan, Passat

LST In-Dash Digital Sonar Gauge. Installation & Operation Instructions

Velocity AV-2. Introduction. 1 Features. Artificial horizon and advanced magnetic compass indicator. Operating Manual English 1.04

Technical Specification. Generating Set with Waukesha engine burning natural gas

Leak Detection System

Introduction to Electronic Signals

ANTI-THEFT SYSTEM Volvo 850 DESCRIPTION & OPERATION BASIC ALARM ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems

SMART SENSOR COLLECTION

Multi-Range Programmable DC Power Supplies 9115 Series

Transmission electronic controls outline. Inputs- processing- outputs

VEHICLE THEFT/SECURITY SYSTEMS

PRODUCT PROFILE FEATURES

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

HERZ-Thermal Actuators

Electronically Controlled Clutchless or Variable Drive Compressors

A/C-HEATER SYSTEM - AUTOMATIC

Battery Tester. GxT Incorporated, Cheboygan MI, U.S.A. All Rights Reserved E040-01G. 40 & 42HD Operator s Manual

INSTALLATION INSTRUCTIONS BOOST CONTROLLER. Pro Control Input (Optional) Tach. Signal. Speed. Gray. Signal. Green Blue. Orange.

1 For All Non-Programmable Digital Thermostat

Diesel Engine Driven Generators Page 1 of 6

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

Operating ambient temperature range: 5ºC to 50ºC Storage temperature range: -30ºC to 70ºC

Cat Electronic Technician 2015A v1.0 Product Status Report 6/3/2015 4:41 PM

Air conditioning, electrical testing

Chevy Bel-Era

WeatherLink for Alarm Output. Introduction. Hardware Installation and Requirements. Addendum

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

LDG DTS-4/4R Desktop Coaxial Switch / Remote

BATTERY MANAGEMENT SYSTEM

User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS

TC-9102 Series Surface Mount Temperature Controllers

Install Guide 3M-50. Caution. Caution

Fire Alarm Control Panel. Family. Operating Manual

Application Engineering

Pulse Width Modulated (PWM) Controller for 12 Volt Motors

Kendrick Astro Instruments

GENERATORS CONTROL PANEL

Passive Anti -Theft System (PATS) Diagnostic Flowcharts. Issue: This bulletin provides diagnostic information for the Passive Anti-Theft System.

Technical Information

AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR. Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002

Models CT-001, CT-002 Owner s Manual

TS1 Ultra Sonic Tank Sender Training. 27 November 2007

CT-001, CT-001-Solar Owner s Manual

A4 Air Conditioning Control Circuit Troubleshooting Rev 7, 6/18/2009

Manual for Fire Suppression & Methane Detection System

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

Install Guide CT101. Caution. Caution

EDI Distributor Control Interface Wiring and Setup Instructions

MEASURE AND CONTROL INVENTORY MANAGEMENT CONSOLE (IMC) Console for stand alone use Console with PC interface, software & USB cable

WIRELESS REMOTE MONITORING OF CATHODIC PROTECTION SYSTEMS. John Hawkyard MICorr Deputy General Manager Rawabi Corrosion Technology Co Ltd Al-Khobar

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

Relays High Capacity 50 Amp Mini Relays Standard Mini Relays Micro Relays Power Relays Connector Modules

Driver Pant 8 and antenna switcher Ant 8. User manual

Operating Instructions

K9 Heat Alarm Owners Manual HA-1520

APPLICATION NOTE. Measuring Current Output Transducers with Campbell Scientific Dataloggers. App. Note Code: 2MI-B Revision: 1

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

Fuel Alert FA-KRS-P21. Mounting instruction

Electrical Systems - IQAN Digital Control System. IQAN Control System Components

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Important: Always perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. P0106, P0107 P0107

PHYSICS 111 LABORATORY Experiment #3 Current, Voltage and Resistance in Series and Parallel Circuits

The Child Reminder System Installation Manual

HVAC-32A. Operation Manual. Specifications. Digital Multistage Air Conditioning Controller with inbuilt Outside Air Economy function

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Electronic Controls / LCD Display

Renewable Energy Test Station (RETS) TEST PROCEDURES FOR SOLAR TUKI

LMS-480M, LMS-480DF & GlobalMap 4800M

D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST

Inverter / Charger Installation General Operations and AC and DC Connections

OWNER S MANUAL 2.5/3.0 ACS PANEL (ADVANCED CONTROL SYSTEM) 7725 Lougheed Highway Burnaby, BC V5A 4V8 Canada

************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D

DCS Series 1 kw, 1.2 kw, & 3 kw

HPC Radiator Fan Control Module with Sensor PN:

Business/ Home GSM Alarm System

Unit 7: Electrical devices LO2: Understand electrical sensors and actuators Sensors temperature the thermistor

Button 1 Button 2. Button 3 Button 4. Programmed Remote Transmitter. Button Function Condition

InHome Water Leak Detection Package

Signature and ISX CM870 Electronics

LAND ROVER MANUAL CONTENTS APPLICATIONS GENERAL OPERATION SPECIAL FUNCTIONS REMOTE CONTROL PROGRAMMING

RVR Hybrid System Installer Instructions RVR Hybrid System Controller Installation Instructions

Centro-Matic Automatic Lubrication Systems System Controls

INSTRUMENT PANEL Volvo 850 DESCRIPTION & OPERATION ACCESSORIES & EQUIPMENT Volvo Instrument Panels

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

Introduction to the iefis Explorer

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

Advantium 2 Plus Alarm

Transcription:

Stratomaster Smart Single TP-1 Combined Oil or fuel pressure gauge Oil or Coolant temperature gauge The TP-1 Temperature/Pressure gauge is a 2.25 instrument intended for display of either the following seelctions: Oil temperature, Coolant temperature, Oil pressure, Fuel pressure, Oil temperature and Oil pressure, Coolant temperature and Fuel pressure, Oil temperature and Fuel pressure. The TP-1 gauge can be programmed by the user for a variety of temperature/pressure ranges and can be adapted to many types of senders, both for temperature and pressure. Temperature can be measured using standard NTC senders as well as the MGL semiconductor sensors. Pressure can be measured using standard VDO automotive senders as well as linear pressure transducers. Both temperature and pressure can activate a programmable alarm. This results in a contact closure that is typically used to switch a warning lamp.

The main display The display can be configured in one of seven modes. Here we use the combined oil temperature and oil pressure display as example. Oil temperature Oil pressure Alarm level (maximum) Alarm level (minimum) Setting up the TP-1 Press the Menu key to enter the menu. You can move forward and backwards in the menu by using the + and keys. To change or select a menu item, move the highlight to the desired item and then press the Menu key. To end an edit or function, press the Menu key again. To exit the menu and continue normal operation, select the ***Done*** function and press the Menu key. Note, all changes you have initiated during your session will only be remembered by the instrument if you exit the menu using the ***Done*** function. DP:. Use this function to setup how you want to use your TP-1. You have a choice of seven basic modes of operation. These are:

Coolant temperature, usually water temperature of your water cooled engine. Uses standard NTC senders or semiconductor senders available from MGL Avionics. Oil temperature. Usually the temperature of the oil in your sump (crankcase). Uses standard NTC senders or semiconductor senders available from MGL Avionics. Oil pressure. The pressure of your oil supply as measured after the oil pump / pressure regulator. Uses standard automotive pressure senders such as available from VDO. Fuel pressure. The pressure of your fuel supply as measured after the fuel pump and pressure regulator (if any). Normally uses standard VDO pressure senders with fuel isolation kit available from VDO. Combined oil temperature and oil pressure display. Most oil sump or dry sump lubricated engines require monitoring of both oil temperature and oil pressure making this option very valuable.

Combined coolant temperature and fuel pressure display. A suitable choice for many water cooled engines. Combined oil temperature and fuel pressure display. This is probably a rare choice given the options above. Temp in degrees Celsius or degrees Fahrenheit. Choose if you want your temperatures displayed in T Range Choose the range (maximum value) that you want to display on your temperature bargraph. You should select a value that is just larger than the maximum temperature you expect to never exceed. Note that the bargraph always starts indicating at ½ your selected maximum range. For example, assume you have selected 100 degrees as maximum value. The bargraph will start indicating from 50 degrees. T Alarm Select the alarm level you want to use for the temperature indication. The alarm level will be marked with a small triangle on the display if you choose a value that is within range of the bargraph. If you do not want to use the alarm, select a value that is higher than will be reached. WTP Select the type of sender you will be using for the water or oil temperature. You can choose either NTC senders (standard automotive) or MGL semiconductor probes. Standard senders are indicated by the choice STD and the MGL probes by PRC. Please note that the type of NTC sender depends on your choice of measuring water or oil temperature. Also note that incompatible probes may result in incorrect temperature readings. Pressure Select if you would like your pressures to be indicated in bar or psi. P Range

Choose the range (maximum value) that you want to display on your pressure bargraph. You should select a value that is just larger than the maximum pressure you expect to never exceed. The pressure bargraph starts indicating at zero pressure. Note that for most senders this would be equivalent to one bar (atmospheric pressure) at sea level. P Alarm Select the alarm level you want to use for the pressure indication. The alarm level will be marked with a small triangle on the display if you choose a value that is within range of the bargraph. If you do not want to use the alarm, select a zero value. Note that the alarm will be activated if pressure is BELOW your chosen level. PR Type Select the type of pressure sender you are using. VDO automotive pressure senders and similar types are resistive senders. They start with a small resistance at no pressure and the resistance increases with pressure. You need to select a resistance value equivalent to a pressure of 10 bar. You will find this value in the data sheets for your sender. Most senders have resistance values in the range of 200 to 400 ohms. You can select the resistance value in steps of 50 ohms from 50 ohm to 1000 ohm. In addition, you can select linear sensors. During the selection these are marked by the word bar after the value. You can select from 1bar to 10bar. Linear sensors typically are amplified semiconductor types. The instrument accepts a voltage reading from the sensor of 0V to 5V corresponding to zero pressure to the value to have selected. Contrast This function allows you to change the display contrast to your liking. You can select values from about 20 to 45. (can vary depending on display type). BL This function allows you to switch the display backlight on or off. ADC This function is for technical personal. It is not used during normal operation of the instrument. Operating the alarms If any alarm is activated, the corresponding item on the display will flash (either the temperature reading, pressure reading or both). At the same time the externally available alarm contact will close. The contact will remain closed until either any button is pressed to acknowledge the alarm or until the condition(s) that activated the alarm no longer exist. The external alarm contact can be used to switch an alarm indicator. The contacts are potential free allowing the contact to be used in existing indicator panels. It is possible to wire the alarm contacts of several smart singles in parallel should this be desired.

Technical specifications: Display temperature range (operational): -20 to +80 degrees C Supply voltage: +8 to +18V. +24/28V with optional pre regulator. Supply current: 25mA/50mA (backlight off/on) Temperature sensors: MGL NTC Water temperature: 900 Ohms at 20 degrees C and 93 ohms at 85 degrees C. MGL Precision semiconductor: Based on National Semiconductor LM335. Oil temperature: Resistance of 1000 ohms at 20 degrees C and 100 ohms at 85 degrees C. (fitted as standard to Rotax 912/914 engines) Pressure sensors: VDO, range 50 to 1000 ohms, 10 bar. Rotax 912/914 standard sender is 200 Ohms. VDO senders used to measure fuel pressure require the fuel isolation kit available from VDO. Linear types from 1bar to 10bar. 0V-05V range, pull-up resistor in instrument is 1K5 to 5V. Weight: 90 grams. Warranty: MGL avionics warrants their products for a period of one year from date of purchase against faulty workmanship. Warranty is limited to the replacement of faulty components and includes the cost of labor. Shipping costs are for the account of the purchaser. Note for operation on supplies with inductive loads: Any operation of electronic instrumentation on power supplies that are subject to high voltages caused by operation of inductive loads (starter motors, solenoids, relays) are required to be fitted with suitable protection. All Smart Singles are guaranteed to withstand temporary over voltage up to 40V without additional protection. We recommend that measures are taken to prevent voltage transients in excess of this limit. MGL Avionics recommends the fitment of a fuse in line with a 33V transorb (available from MGL Avionics at low cost) to protect electronic instruments, radios and intercom systems. Only one such arrangement is required for a cluster of instruments. Please note that product warranty excludes damages caused by unprotected, unsuitable or incorrectly wired electrical supplies. This instrument is not certified by the FAA. Fitting of this instrument to certified aircraft is subject to the rules and conditions pertaining to such in your country. Please check with your local aviation authorities if in doubt. This instrument is intended for ultralight, microlight, homebuilt and experimental aircraft. Operation of this instrument is the sole responsibility of the pilot in command (PIC) of the aircraft. This person must be proficient and carry a valid and relevant pilots license. This person has to make him/herself familiar with the operation of this instrument and the effect of any possible failure or malfunction. Under no circumstances does the manufacturer condone usage of this instrument for IFR flights.

Installing the TP-1 Temperature sender Pressure sender Ground (-) Alarm lamp TP-1 Temperature and Pressure gauge Alarm +12V- DC Fuse 33V Transorb protection device Power switch Positive supply (+12V from battery) Negative supply (airframe ground) Connect the supply terminals to your aircraft s power supply (you need a dropping resistor or preregulator for 24/28V systems). Install suitable power supply protection if you have a supply that can contain large voltage transients such as can be created by starter motors and solenoids. Ensure that the supply voltage will not drop below 8V during operation as this may result in incorrect readings. Install a suitable alarm lamp. Typically this would be a 12V/1W panel mount lamp (pilot lamp) available as accessory in most automotive supply shops. Temperature senders Three types of sender can be fitted: Water temperature senders (NTC types). A suitable sender with the same thread used by Rotax can be obtained from MGL Avionics. If you source your own sender, ensure that it has the following characteristics: 900 Ohms at 20 degrees C and 93 ohms at 85 degrees C. Oil temperature senders (NTC types). A standard automotive sender as fitted by Rotax to 912/914 engines can be used. It has the following characteristics: Resistance of 100 ohms at 85 degrees C and 1000 ohms at 20 degrees C. MGL Precision senders: These are senders containing a semiconductor temperature measurement device. They can be used for water or oil temperature. These senders are available in two types: An encapsulated version with a brass housing suitable for Rotax thread. A second uncommitted version contains only the sensor itself. This can be conveniently mounted inside an

existing sender housing after you remove the original insides of the sender. This is intended to give you a solution for unusual or difficult to obtain senders. Most NTC senders require a single wire connected as shown. The sender is grounded via the engine block. The ground terminal of the gauge input should be connected to the engine block. Some NTC senders have two wires. In this case it is not required that the sender housing itself is connected to the engine block. Wire the second wire as indicated (dotted line). Pressure senders Pressure senders come in two basic varieties. The first are the automotive types (for example from VDO), the second are the electronic types with linear output. Most pressure senders used for engines are piezo-resistive types. These tend to have a very low resistance at low pressures and a high resistance at their maximum pressure output. The resistance is approximately linear with pressure. The TP-1 allows you to choose the pressure sender type as described in the relevant section of this manual. Most automotive types have resistance ranges from 200 to 400 ohms. For example the oil pressure sender as installed in a Rotax 912/914 engine has a 200 ohm resistance for 10 bars pressure. Linear output senders that can be used with the TP-1 are those types that have their maximum output voltage of 5V at their maximum pressure output. This can be selected in the TP-1 from 1 to 10 bars. Senders can have either one or two wires, the two wire senders need one connection to ground. Wire them up as indicated in the drawing (dotted line as ground terminal). Please note that two wire senders may be sensitive to polarity. One of the two wires is a dedicated ground terminal that has to be connected to ground (minus of the battery or engine block). Senders that are grounded in the engine block Single wire senders require that their mounting arrangement (thread) has a very good electrical contact with the engine block. Avoid the use of any sealant or tapes as these may cause a bad electrical connection. Further to this it is very important that the engine block has a good electrical connection to the negative supply terminal of the TP-1. Any voltage drop caused by other equipment on the ground wire will cause incorrect readings. The best way to ensure a good connection is to wire a single connection between the TP-1 ground terminal (any of these terminals) to the engine block. Don t wire this anywhere else and do not allow any other equipment to use this wire as a current return path.