Z5375 T Base plate Mounting instructions (1.1 EN)



Similar documents
R60 USB to CAN interface Manual (1.5 EN)

TI 313 (1.0 EN) d&b Remote network - Integration

Owner s Manual Gantry Cranes

Rack installation instructions

EKX Passive Loudspeakers

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

CA-6050 Solar Power Unit. User Guide. Designed to work with the Norsonic range of sound level meters to provide a DC supply in remote locations.

Table of Contents WARNING SYMBOLS AND DEFINITIONS

Unpacking, Installation, and Customization

W8VDQ. User s Guide. The Martin Experience. All material Martin Audio Ltd. Subject to change without notice.

CONTENTS TOOLS REQUIRED: Ratchet 13mm Socket 10mm Socket Phillips Screwdriver Pliers Panel Removal Tool. Amp Installation

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

Changing the SIM in a BANDIT Product s GSM Card

16/32 Channel 1U Rack Mount CCTV Power Supply

Auto-belay Cable Replacement Process

EXPLORE 4-Leg Teaming Table with Screen Share Assembly Instructions

4 in 1 Strength Station

STEEL-RITE II or III COMMERCIAL SECTIONAL DOOR Owner s Manual Supplement Model NOTICE TO USER

Software Newsletter April 2016

SELF-STEERING AXLE TABLE OF CONTENTS

Installation Instructions

FPU SYSTEMS OPERATION MANUAL BOH OFFICE MODULE (INCLUDING REPAIR PARTS & SPECIAL TOOL LIST) BOH FPU Field Pack/up Units CHAPTER 5

6 inch A-Arm Lift Kit WARNING: / installation instructions. will fit CLUB CAR DS. included:

IN00419 (rev A) Aqua 6 Glide Quadrant and Off-set Quadrant Enclosure

Operating, Installation, and Maintenance Instructions

42U/45U 28" Wide Rack Installation & Service Guide

AMU PROFESSIONAL VIDEO AND AUDIO MONITORING UNIT OPERATOR'S HANDBOOK ISSUE A3

DCF Optimized Rack System

HYDRAULIC TABLE CART 500-LB.

GEK-90214B. GE Lift Truck. User s Guide 144D2933G1 144D2912G1 144D2911G5

Structural Holding System

I BEAM TRACK INSTALLATION

In-Ground Basketball System Owners Manual

Installation instructions, accessories - Handsfree for cellular phone, system B, entry level

Installation Instructions

Chapter 10 - Scaffolding Systems

STEADYfast Stabilizer Installation Notes Fifth Wheel and Travel Trailers 11/23/13

Instructions for assembly of your Pop-Up Display

BLADE S-MAX Cabinet for Blade Server

Advantium 2 Plus Alarm

All-Season Sunroom Sliding Glass Door Installation Instructions

Instrument panel. Volkswagen Touareg - Instrument panel. Special tools, testers and auxiliary items required. Release lever T10039

10 TON HYDRAULIC PRESS

R70 Ethernet to CAN interface Manual (1.4 EN)

ENGLISH FORK GUIDE 2013

SAFETY & OPERATING INSTRUCTIONS

INSTRUCTION BOOK FOR. Dual Monitor Video Conferencing Cart

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

Installation Instructions S

EVID Compact Sound Speaker System

Remote Head REMO ONE. Code Manual

R70 Ethernet to CAN interface Software reference manual (1.3 EN)

CELO5. User & Installation Manual.

HP Laser Jet 2400 Series Fixing Drive Side Plate Assembly Fixing Drive Side Plate Assembly- RM page 1

UPLIFT Height Adjustable Standing Desk (T-Frame) DIRECTIONS FOR ASSEMBLY AND USE - - ALSO - - Watch our assembly video

Vision Engravers and Routers PRE-Installation Guide Vision Engraving & Routing Systems

Contents. The d&b System reality. 4. The Stage monitors. 8. The MAX2 monitor. 10. The M6 monitor. 11. The M4 monitor. 12. The M2 monitor.

These Installation Instructions are valid for antennas in the following version:

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

Owner s Manual & Safety Instructions

AMPSEAL* Automotive Plug Connector and Header Assembly

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

Elecraft K3 KPA3 Power Connector Replacement Revision A Review, April 16, 2012 Copyright 2012, Elecraft, Inc. All Rights Reserved

SERVICE PARTS LIST PAGE 1 OF 6 BASE ASSEMBLY SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 12" DUAL BEVEL COMPOUND MITER SAW B27A

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

No Phone Line II-48 System

Water Pump Replacement

GENUINE PARTS INSTALLATION INSTRUCTIONS

Depending on which elastic support you have you can secure the V2 power unit to the following seat bracket tubes: EXTERNAL DIAMETER 27.

Kiosk Group, Inc. ASSEMBLY INSTRUCTIONS FOR THE STANDALONE. EXQUISITE ipad KIOSK. For ipad Version Tablets.

INSTALLATION INSTRUCTIONS for Bifold Doors (JII103)

1 Ton Telescoping Gantry Crane

39HQ Airovision Air Handling Units

POLE MOUNT SYSTEM-3 INSTALLATION

Installation Instructions

Installation information. METTLER TOLEDO MultiRange Floor scales / Pit scales

SIMPLEX UNICAN LOCKS CHANGING THE CODE / COMBINATION 900 Series 1000 Series L1000 Series LP1000 Series EE1000 Series 2000 Series 2015 Series

EXCAVATOR SAFETY TRAINING

GEH6290. Mechanism Circuit Breaker. Handle Operating Mechanism Cat. No. Type NEMA 1, 3R, 12, 13 NEMA 4/4X Cat. No. Cat. No. Series Instruction

Installation Instructions

Express5800/120Ed. Rack Mount Kit Installation Procedures PN:

VOT-320. VOT-320V0xxL VOT-320V0xxH. Quick Installation Guide

ReadyKart Mobile Processing Station Instructions for Use

ATS Overhead Table Shelf System INSTRUCTION MANUAL

The completely Ethernet-based. protocol enables several imode devices to be linked, using easily-sourced. cables and components.

Achat 208 HL / 208 HR passive mid-range speaker. user manual

Abena Vac Instruction Manual

HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in

2003 ACCORD - Automatic Transmission Removal

WARNING! Failure to follow these inspection procedures can cause personal injury and property damage.

E2600 DSA E-Series iscsi Disk Arrays. en Quick Install Guide

AstroSystems Digital Setting Circles for Zhumell, GSO, Apertura and Astro-Tech

19 DYNAmax Free Standing Server C A B I N E T s

New method, replacement of window and window lift, front door

HP Laser Jet 4200/4240/4250/4300/4350 Swing Plate

Check for deteriorated, shifting or missing tie-down pads. Replace if needed.

************* OWNER'S MANUAL BAMF800/2 BAMF1250/2 BAMF1800/2 BAMF2200/2 BAMF2600/2 BAMF1200/4 BAMF1600/4 BAMF2000/1D BAMF4000/1D BAMF5500/1D

SETTING UP YOUR 6000 SERIES TIME RECORDER

FTC DIY Mountain Build Guide

Transcription:

Z5375 T Base plate Mounting instructions (1.1 EN)

Contents 1. Scope of supply...3 2. Intended use...3 3. Preparations...3 T10 cabinets...3 4. Setup of the assembly...5 5. Maintenance and care...7 Storing/transport...7 Cleaning...7 Inspections...7 6. Disposal...7 General Information Z5375 T Base plate Mounting instructions Version 1.1 EN, 12/2012, D2999.EN.01 Copyright 2012 d&b audiotechnik GmbH; all rights reserved. Keep this manual with the product or in a safe place so that it is available for future reference. d&b audiotechnik GmbH Eugen-Adolff-Strasse 134, D-71522 Backnang, Germany Telephone +49-7191-9669-0, Fax +49-7191-95 00 00 E-mail: docadmin@dbaudio.com, Internet: www.dbaudio.com

Z5375 T Base plate 1. Scope of supply Please verify the shipment for completeness and proper condition of the items. Qty. d&b Code Description 1 Z5375 T Base plate [1] 1 including hand bolt M20 x 25 [2] Fig. 1:Z5375 T Base plate 1 D2999.INT Mounting instructions 2. Intended use The Z5375 T Base plate must only be used in conjunction with d&b T10 loudspeakers as described in these mounting instructions. Installation and setup should only be carried out by qualified and authorized personnel observing the valid national Rules for the Prevention of Accidents (RPA). GROUND USE: 3 x T10 MAX. 6 x T10 MAX. WHEN CONNECTED TO SUB NOT FOR FLOWN USE Fig. 2: Z5375 T Base plate, intended use The Z5375 T Base plate is designed to support up to three T10 Line array cabinets in a ground stacked setup and is equipped with three rubber feet. The Z5375 T Base plate is not intended for flown use. The angle of the lowest cabinet can be set in the range from +5 to 8. When used on top of d&b subwoofers such as Q-SUB, E15X-SUB, B4-SUB or V-SUB, the T Base plate is secured to the subwoofer using the M20 flange in the top panel of the subwoofer. It can then support a column of up to six T10 cabinets. 3. Preparations T10 cabinets Altering the HF dispersion on T10 cabinets When setting up T-Series arrays and ground stacks set the T10 cabinets to line source mode. Swapping between point and line source setups is performed by simply rotating the horn by 90. The horn is easily accessible from outside of the cabinet and can be rotated without any tools or removal of the front grill. This is achieved through apertures on the cabinet sides by a mechanism that provides detents at both the line and point source positions. Fig. 3: Rotating the horn (shown without front grill for better illustration) The line source mode is indicated by a label on the horn marked with LINE as shown in the picture below. Z5375 Mounting instructions (1.1 EN) Page 3 of 8

Functionality of the cabinet's rigging mechanism Front link mechanism - Slide out the Front link until it is fixed in place. Splay link mechanism - Release both Locking pins and fold out the Splay link. Preset splay angles on T10 cabinets The splay angles between T10 cabinets can be set in the range from 0 to 15 in 1 steps. The splay angles are set at the central rear rigging strands of the T10 cabinets. Z5375 Mounting instructions (1.1 EN) Page 4 of 8

Interconnecting the cabinets The T10 cabinets are interconnected by their Front links on both sides of the cabinet front and the Splay links on the center rigging strand at the cabinet's rear. Front links Once the Front links slide into the respective track of the next cabinet, the cabinets are interconnected by inserting the Locking pins on both sides of the cabinet. Splay links Fold out the Splay links of the T10 cabinets and hook them into the preset Locking pins on the rear rigging strand of the next cabinet. Once the Splay link is hooked in, the second Locking pin must be inserted. The second Locking pin acts as a "safety pin" to secure the Splay link from possible hooking off and to fix the set splay angle. 4. Setup of the assembly WARNING! Always secure ground stacked setups against movement and possible tipping over. Preparations - Prepare the cables and link cables according to the number of amplifier channels and cabinets used. - Ensure the HF sections of the T10 cabinets to be used are set to Line source. 1. Prepare the the T Base plate T10 Groundstack - Place the T Base plate on the ground. T10/SUB Groundstack - Connect the T Base plate with the M20 threaded insert of the respective subwoofer using the M20 hand bolt. 2. Add the first cabinet - Release the locking pins on both sides of the cabinet front. - Attach the cabinet to the T Base plate. - Insert the Locking pins of the Front links on both sides of the cabinet. Z5375 Mounting instructions (1.1 EN) Page 5 of 8

3. Set the angle of the first cabinet The angle (vertical aiming) of the lowest cabinet can be set in the range from +5 to 8. The desired angle is set using the corresponding hole of the Splay link of the Base plate and the hole grid of the rear rigging strand of the T10 cabinet. The derived scale is shown in the graphic opposite. The notch at the top of the Base plate's Splay link is intended to simplify the mechanical setup and provides a +2 offset in relation to the hole of the link. To set the angle proceed as follows: - Fold out the Splay link of the cabinet. - Lift the back of the cabinet - Insert the first Locking pin into the corresponding hole of the rear rigging strand of the cabinet. Example: To achieve a 5 downtilt of the first cabinet, insert the first Locking pin (support pin) into the 5 hole of the cabinet. - Fold up the Base plate's link into the rear rigging strand and lower the cabinet's back into the notch of the link. - Insert the second Locking pin (safety pin) into the 3 hole of the cabinet to secure the link of the Base plate. 4. Add the next cabinet - Slide out the Front link at bottom cabinet. - Fold out the Splay link. - Release the Locking pins on both sides of the cabinet front. - Attach the cabinet to the first cabinet. - Insert the Locking pins of the Front links on both sides of the cabinet. To attach further cabinets, proceed in the same manner. Z5375 Mounting instructions (1.1 EN) Page 6 of 8

5. Set the desired splay angle - On the rear, set the splay angles between the cabinets as follows: - Preset the desired splay angle on the top cabinet by inserting one Locking pin. - Fold up the Splay link of the cabinet below into the rear rigging strand of the upper cabinet. - Lift the upper cabinet by hand until the hook of the Splay link has hooked into the preset Locking pin. - Insert the second Locking pin (safety pin) to secure the Splay link. 5. Maintenance and care Storing/transport The surface treatment temporarily protects the Base plate against moisture. However, ensure the Base plate is in a dry state when storing and transporting it. During transport ensure the Base plate is not stressed or damaged by mechanical forces. Use suitable transport cases. Cleaning Regularly clean and lubricate the Base plate using WD-40 or a similar product. Inspections To eliminate the potential risk of accident due to malfunctioning of the Base plate, regularly carry out a visual and functional inspection. If the Base plate fails to operate correctly and/or safely, it must be withdrawn from use immediately. Carry out a visual inspection of the Base plate for obvious deformation and damage (e.g. cracks and corrosion). 6. Disposal Please dispose of this product according to the respective national regulations. Ensure that damaged rigging components are disposed of so that they cannot be used again. Z5375 Mounting instructions (1.1 EN) Page 7 of 8

d&b audiotechnik GmbH, Eugen-Adolff-Str. 134, D-71522 Backnang, Germany, Phone +49-7191-9669-0, Fax +49-7191-95 00 00 D2999.EN.01, 12/2012 d&b audiotechnik GmbH