Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance



Similar documents
LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Determination of Anabolic Steroids in Horse Urine by SPE and LC-MS/MS

A Novel Approach to Low Volume Sample Preparation

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

Oasis HLB Cartridges and 96-Well Plates

Rapid Screening Method for Illicit Drugs, Using an Advanced Solid Core UHPLC Column and UHPLC System with MS/MS Detection

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

Thermo Scientific HyperSep Solid Phase Extraction Method Development Guide

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method

Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS

Thermo Scientific Chromatography Columns and Consumables Your world of. chromatography

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

UPLC-MS/MS Analysis of Aldosterone in Plasma for Clinical Research

Utilization of Rapid LC-MS for Screening and Quantitative Analysis of Pesticides in Food Matrix using an Exactive Plus Benchtop Orbitrap Platform

How To Test For Contamination In Large Volume Water

Sensitive steroid analysis on a new High Speed Triple Quadrupole LC/MS/MS. Mikaël LEVI Shimadzu France

Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation

High sensitivity assays using online SPE-LC-MS/MS -How low can you go? Mohammed Abrar Unilabs York Bioanalytical solutions, York, UK

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

High-Throughput 3-D Chromatography Through Ion Exchange SPE

Determination of Tetracycline Antibiotics in Milk Using a Simple Strong Cation-Exchange SPE Cleanup Procedure and LC-MS/MS Analysis

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

Method Development of LC-MS/MS Analysis of Aminoglycoside Drugs: Challenges and Solutions

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

GENERAL UNKNOWN SCREENING FOR DRUGS IN BIOLOGICAL SAMPLES BY LC/MS Luc Humbert1, Michel Lhermitte 1, Frederic Grisel 2 1

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

Comparison of the Reversed-Phase Selectivity of Solid Core HPLC Columns

Ultra Fast UHPLC-LCMSMS Method Development in Clinical Drug Monitoring

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

Click on Table of Contents. Then type desired page number & click OK.

Standard Analytical Methods of Bioactive Metabolitesfrom Lonicera japonica Flower Buds by HPLC-DAD and HPLC-MS/MS

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

A Determination of Veterinary Drug Residues in Milk Using Polymeric SPE and UHPLC-MS/MS Analysis

AppNote 1/2014. Automated Hydrolysis, DPX Extraction and LC/MS/MS Analysis of Pain Management Drugs from Urine KEYWORDS ABSTRACT

Empore. 96-Well Solid Phase Extraction Plates. Technical Information. Instructions for Use. Product Characteristics. Product Description

Purification of reaction mixtures using flash chromatography.

Thermo Scientific Mass Spectrometric Immunoassay (MSIA)

Gas Chromatography Liner Selection Guide

SIMULTANEOUS DETERMINATION OF TELMISARTAN AND HYDROCHLOROTHIAZIDE IN TABLET DOSAGE FORM USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

Thermo Scientific Syncronis HPLC Columns. Technical Manual

Solid Phase Extraction Products PAGE: 1. Introduction of Solid Phase Extraction (SPE) Why Choose Nano-Micro Tech SPE

The Automated SPE Assay of Fipronil and Its Metabolites from Bee Pollen.

Introduction. Methods. Sample Processing

Using Natural Products Application Solution with UNIFI for the Identification of Chemical Ingredients of Green Tea Extract

Accelerate your Quantitative LC/MS Workflows with a Fully Integrated UHPLC-QQQ Platform

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

CORESTA RECOMMENDED METHOD N 72

A Complete Solution for Method Linearity in HPLC and UHPLC

United States Department of Agriculture Food Safety and Inspection Service, Office of Public Health Science

Determination of Haloacetic Acids and Dalapon in Drinking Water by SPE and GC/ECD*

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

New drugs of abuse? A case study on Phenazepam & Methoxetamine

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

APPLICATIONS MANUAL. Ifosfamide in blood serum Ingredients in blood serum Organophosphorus pesticides in tea leaf... 5

Sample Preparation for Forensic Toxicology and Clinical Research. Part 1: Sample Preparation Options

Analysis of Free Bromate Ions in Tap Water using an ACQUITY UPLC BEH Amide Column

Quick and Sensitive Analysis of Multiclass Veterinary Drug Residues in Meat, Plasma, and Milk on a Q Exactive Focus LC-MS System

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008)

Analysis of Polyphenols in Fruit Juices Using ACQUITY UPLC H-Class with UV and MS Detection

for SolEx TM HRP Cartridges SolEx TM HRP RSLC Columns

Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension

An Automated Method for the Selective Solid Phase Extraction of Zearalenone from Wheat Using Molecularly Imprinted Polymers

Cliquid Drug Screen & Quant Software for Routine Forensic Toxicology. great interest in forensic, toxicological and clinical research laboratories.

Basics of SPE Technology & Mechanisms. Pieter Grobler, Sigma-Aldrich RSA

Solid Phase Extraction for Water Analysis. presented by

How To Use An Acquity Qda Detector

AppNote 1/2012. Rapid Cleanup and Comprehensive Screening of Pain Management Drugs in Urine using Automated Disposable Pipette Extraction and LC-MS/MS

Thermo Scientific Dionex Chromeleon 7 Chromatography Data System Software

Analysis of Pesticides in Vegetables Using the Agilent 1260 Infinity Analytical SFC System with Triple Quadrupole MS Detection

A feasibility study of the determination of B-group vitamins in food by HPLC with Mass Spectrometric detection. LGC/R/2011/181 LGC Limited 2011

Opiates in Urine by SAMHSA GC/MS

LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)

Online SPE-LC-APCI-MS/MS for the Determination of Steroidal Hormones in Drinking Water

Application Note # LCMS-92 Interlaboratory Tests Demonstrate the Robustness and Transferability of the Toxtyper Workflow

SUCRALOSE. White to off-white, practically odourless crystalline powder

Method development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report

Conversion of a USP Gas Chromatography Method to Convergence Chromatography: Analysis of Atropa Belladonna

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

ORGANIC SAMPLE PREPARATION

Agilent Enhanced Matrix Removal Lipid LOSE THE LIPIDS, FIND YOUR ANALYTES

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

Innovative vs Traditional

A Generic Kit-Based Approach for Quantifying Monoclonal Antibody Drugs Through Direct Digestion of Discovery Study Samples

ABRF 2004 Poster# P55-S Displacement Chromatography Effects Can Cause Highly Selective Sampling of Peptides During Solid Phase Extraction Cleanup

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

The basic division explosives for forensic purposes is shown in Fig. 1

Transcription:

Thermo Scientific SOLA SPE cartridges and plates Technical Guide Join the revolution unparalleled performance

Join the revolution next-generation SPE Thermo Scientific SOLA products revolutionize Solid Phase Extraction (SPE). This first fritless SPE product range provides greater reproducibility with cleaner, more consistent extracts. SOLA products provide unparalleled performance characteristics compared to conventional SPE, phospholipid removal and protein precipitation products. This includes: Higher levels of reproducibility Higher levels of extract cleanliness Reduced solvent requirements Increased sensitivity The proprietary manufacturing process involved in the production of SOLA products provides an SPE product which eliminates issues normally associated with conventional loose-packed SPE products, by combining the polyethylene frit material and media components into a uniform sorbent bed, removing the need for frits (Figure 1). No voiding No channeling Reproducible packing time after time Figure 1: SOLA eliminates common issues associated with conventional SPE

The manufacturing process has the additional benefit of removing extractables from component parts, resulting in cleaner sample extracts. SOLA products provide reduced failure rates, higher analysis speeds and lower solvent requirements, which are critical in today s laboratory environment. The increased performance delivered by SOLA products provides higher confidence in analytical results and lowers cost without compromising ease of use or requiring complex method development. Conventional SPE cartridges and well plates are packed with a loose powder of silica or polymeric material positioned between two frits. These packed beds are potentially prone to settling and voiding in production or transportation. This creates phase channeling and packing irreproducibility, resulting in reduced recovery and reproducibility in analytical results (Figure 2). Voiding Channeling Flow through Packing inconsistency Figure 2: Examples of conventional SPE product issues Technical Guide 3

Technical information The following information highlights the advantages associated with SOLA products over conventional loose-packed SPE products. Improved reproducibility and recovery Figure 3 shows the reproducibility and recovery levels of SOLA products for three test probes; caffeine, hydrocortisone and carbamazepine when compared to two equivalent loose-packed, low bed weight, competitor products. The data shows that SOLA products outperform competitor products, even when utilizing the recommended generic competitor methodology. Error bars illustrate significantly lower variability sample-to-sample for SOLA products compared to conventional SPE products, ensuring you achieve the correct result time after time. SOLA precision (%RSD) 2.7 Competitor (i) precision (%RSD) 21.8 Competitor (ii) precision (%RSD) 7.8 1% 9% 8% 7% % Recovery 6% 5% 4% 3% 2% 1% % Caffeine Hydrocortisone Carbamazepine SOLA Competitor (i) Competitor (ii) Figure 3: SOLA shows significantly higher reproducibility and recovery levels Caffeine Hydrocortisone Carbamazepine Method SOLA precision (%RSD) Competitor (i) precision (%RSD) Competitor (ii) precision (%RSD) 4.4 3.3 2.7 23.9 2.5 21.8 12.1 1.4 7.8 Condition: Equilibrate: Load: Wash: Elute: 2μL methanol 2μL water 1mL sample 2μL 5% methanol in water 2μL methanol 4 Technical Guide

Improved reproducibility Figure 4 highlights the reproducibility of SOLA products with three test probes; caffeine, hydrocortisone and carbamazepine when compared to an equivalent loose-packed, low bed weight, competitor product. The data shows that SOLA products have consistent recoveries across all thirty test samples. The conventional loose-packed SPE product from competitor (i) shows that on average one in every four samples gives a significantly lower recovery. This results in inconsistencies in results. In comparison, SOLA products provide significantly higher levels of reproducibility, which is vitally important for high-throughput studies. This improved reproducibility is further demonstrated in Figure 5, which shows that SOLA products have more uniform flow-though characteristics compared to the equivalent loose-packed, low bed weight, competitor products. Caffeine SOLA Competitor (i) 12.% 1.% % Recovery % Recovery % Recovery 8.% 6.% 4.% 2.%.% 5 1 15 2 25 3 35 Sample number Hydrocortisone SOLA Competitor (i) 12.% 1.% 8.% 6.% 4.% 2.%.% 5 1 15 2 25 3 35 Sample number Carbamazepine SOLA Competitor (i) 12.% 1.% 8.% 6.% 4.% 2.%.% 5 1 15 2 25 3 35 Sample number Figure 4: Shows inconsistency of loose-packed products compared to SOLA products 25. 2. Air flow ml/min 15. 1. 5.. 5 1 15 2 25 3 35 SOLA Competitor (i) Competitor (ii) Sample number Figure 5: The consistent flow rate of SOLA products compared to equivalent loose-packed products Technical Guide 5

Reproducibility in plasma Due to their nature, biological matrices such as plasma present a difficult challenge in obtaining reproducible results. The excellent performance characteristics of SOLA products provide high levels of reproducibility, even when dealing with these difficult matrices. This has been demonstrated by the extraction of rosuvastatin from human plasma using a SOLA 96 well plate. Figure 6 shows the precision data for extractions of a fixed concentration of analyte across the entire plate. This can be visually observed in Figure 7, which shows randomly selected overlaid chromatograms of rosuvastatin. Precision (%RSD) Rosuvastatin (area of 96 replicates) 5.4 d6-rosuvastatin (area of 96 replicates) Response ratio (of 96 replicates) 3.9 2.7 1 75 1.59 Figure 6: Precision (%RSD) data for rosuvastatin Relative Abundance 5 25 1.52 1.54 1.56 1.58 1.6 1.62 1.64 Figure 7: Overlaid chromatograms of rosuvastatin Higher sensitivity and lower solvent consumption Figure 8 shows that SOLA products achieve excellent recovery levels even with low volumes of extract solvents, resulting in a more concentrated analyte and increased sensitivity. Additional cost and time saving benefits can be achieved from reduced sample dry-down time and solvent usage. These low-volume extractions would be significantly compromised when using a conventional loose-packed, low bed weight, SPE product. See Figure 9. 14.% 12.% % Recovery 1.% 8.% 6.% 4.% 2.% 1µL 15µL 2µL 25µL 3µL 5µL.% Caffeine Hydrocortisone Carbamazepine Figure 8: High recovery levels are achieved with SOLA products at low elution volumes, resulting in increased sample concentrations and sensitivity 6 Technical Guide

SOLA products exhibit recovery and reproducibility levels at low extraction volumes which are significantly better than conventional loose-packed, low bed weight, competitor products. 1.% % Recovery 8.% 6.% 4.% 2.%.% -2.% 15µL 2µL 25µL Elution Volume SOLA Competitor (i) Competitor (ii) The error bars illustrate significantly lower variability sample-to-sample for SOLA compared to conventional SPE products. This ensures correct results time after time, even at low elution volumes. Conventional loose-packed SPE products are unable to compete with the reproducibility or recovery levels of SOLA products at these low elution volumes. Caffeine 1.% 8.% % Recovery 6.% 4.% 2.%.% -2.% 15µL 2µL 25µL Elution Volume Significantly higher recovery levels are achieved with SOLA products at an elution volume of 15µL for caffeine, hydrocortisone and carbamazepine compared to competitor loose-packed SPE products. SOLA Competitor (i) Competitor (ii) Hydrocortisone 1.% 8.% % Recovery 6.% 4.% 2.%.% -2.% 15µL 2µL 25µL Elution Volume SOLA Competitor (i) Competitor (ii) Carbamazepine Figure 9: SOLA products recovery and reproducibility at lower extraction volumes Technical Guide 7

Cleanliness of extract SOLA products proprietary manufacturing process provides a cleaner product and, as a result, a cleaner sample extract. This is shown in Figure 1, where SOLA products are compared against competitor (i) conventional loose-packed SPE product, which have both been extracted with acetonitrile, dichloromethane and methanol, respectively. 1 9 SOLA Competitor (i) 8 Relative Abundance 7 6 5 4 3 2 1. 1. 2. 3. 4. 5. 6. 7. Acetonitrile extract comparison: SOLA products versus competitor (i) 1 9 SOLA Competitor (i) 8 Relative Abundance 7 6 5 4 3 2 1. 1. 2. 3. 4. 5. 6. 7. Dichloromethane extract comparison: SOLA products versus competitor (i) 1 9 SOLA Competitor (i) 8 Relative Abundance 7 6 5 4 3 2 1. 1. 2. 3. 4. 5. 6. 7. Methanol extract comparison: SOLA products versus competitor (i) Figure 1: SOLA products are significantly cleaner than the equivalent loose-packed SPE product from competitor (i) 8 Technical Guide

SOLA products offer greater selectivity, reproducibility and cleanliness of sample extract, compared to other sample preparation technologies such as protein precipitation and phospholipid removal plates. This is exemplified in Figure 11, which shows MS contour plots from these respective technologies. It can be seen that SOLA products provide cleaner sample extracts resulting in greater confidence in your analytical results. 15 15 1 1 95 95 9 9 85 85 8 8 75 75 7 7 65 65 6 m/z 6 m/z 55 55 5 5 45 45 4 4 35 35 3 3 25 25 2 2.5 1. 1.5 2. 2.5 3. 3.5 4. 4.5 5. 5.5 6. 6.5 7. 15.5 1. 1.5 2. 2.5 3. 3.5 4. 4.5 5. 5.5 6. 6.5 7. 15 Protein precipitation Phospholipid removal plate 15 1 95 9 Significantly more interferences have been removed using SOLA AX 85 8 75 7 65 6 m/z 55 5 45 4 35 3 25 2.5 1. 1.5 2. 2.5 3. 3.5 4. 4.5 5. 5.5 6. 6.5 7. 15 SOLA AX Figure 11: MS contour plots from protein precipitation, phospholipid removal plates and SOLA AX Technical Guide 9

Failure to remove the matrix interferences in the primary sample preparation process can result in substantial carry over of phospholipids from sample-to-sample. Figure 12 shows MS contour plots of subsequent blank injections. This shows that there is considerable carry over when using protein precipitation or phospholipid removal products when compared to SOLA products. Removal of phospholipids are key to reducing ion suppression, obtaining improved sensitivity in MS detection and providing confidence in analytical results. It also prevents the need for costly column and system maintenance. 15 15 1 1 95 95 9 9 85 85 8 8 75 75 7 7 65 65 6 m/z 6 m/z 55 55 5 5 45 45 4 4 35 35 3 3 25 25 2 2.5 1. 1.5 2. 2.5 3. 3.5 4. 4.5 5. 5.5 6. 6.5 7. 15.5 1. 1.5 2. 2.5 3. 3.5 4. 4.5 5. 5.5 6. 6.5 7. 15 Protein precipitation Phospholipid removal plate 15 1 95 9 The subsequent blank injection shows a clean MS contour plot with SOLA AX 85 8 75 7 65 6 m/z 55 5 45 4 35 3 25 2.5 1. 1.5 2. 2.5 3. 3.5 4. 4.5 5. 5.5 6. 6.5 7. 15 SOLA AX Figure 12: MS contour plots of the subsequent blank injections - protein precipitation, phospholipid removal and SOLA AX 1 Technical Guide

SOLA product methods The previous data shows how SOLA products can outperform conventional loose-packed competitor SPE products, even when using competitor prescribed methodology. The generic SOLA product methods outlined below are designed to be a starting point for most sample extraction protocols. Generic method protocol for cartridge and 96 well plate formats. SOLA Reverse phase SOLA CX Mixed mode cation exchanger SOLA AX Mixed mode anion exchanger CONDITION: EQUILIBRATE: LOAD: WASH 1: 5µL methanol 5µL water 5 to 5µL of sample at 1mL/min 5µL 5% methanol in water ELUTE: 2µL - 5µL methanol CONDITION: EQUILIBRATE: LOAD: WASH 1: WASH 2: 5µL methanol 5µL water with 1% formic acid 5 to 5µL of sample at 1mL/min containing 1% formic acid 5µL water with 1% formic acid 5µL methanol with 1% formic acid ELUTE: 2µL - 5µL methanol with 1% ammonium hydroxide CONDITION: EQUILIBRATE: LOAD: WASH 1: WASH 2: 5µL methanol 5µL water with 1% ammonium hydroxide 5 to 5µL of sample at 1mL/min containing 1% ammonium hydroxide 5µL water with 1% ammonium hydroxide 5µL methanol with 1% ammonium hydroxide ELUTE: 2µL - 5µL methanol with 1% formic acid For more advice on how you can use SOLA products to improve your sample preparation, please visit the Chromatography Resource Center at www.thermoscientific.com/chromatography Technical Guide 11

Beta blockers from urine on SOLA CX atenolol, pindolol, metoprolol, propranolol, alprenolol SOLA CX SPE protocol Product: SOLA CX 1mg/mL cartridge p/n 619-2 Matrix: urine Condition: 5µL methanol Equilibrate: 5µL water Load: 2µL spiked urine Wash 1: 25µL water +.1% formic acid Wash 2: 25µL methanol +.1% formic acid Elute: 25µL 8:2 (v/v) DCM:IPA + 5% ammonium hydroxide Dry: under nitrogen Reconstitute: 2µL 9:1 (v/v) water:methanol HPLC conditions Instrumentation: Column: Mobile phase A: Mobile phase B: Thermo Scientific HPLC Thermo Scientific Accucore C18 5μm 5 x 2.1mm p/n 17126-5213 water +.1% formic acid methanol +.1% formic acid Gradient: t/min %A %B. 9 1 2.5 6 4 Flow rate:.7ml/min Column temperature: 45 C Injection volume: 1μL Detector wavelength: 22nm mau 14 12 1 8 6 4 2-2 -4-6.5 1. 1.5 2. 2.5 Compound Atenolol Pindolol Metoprolol Propranolol Alprenolol Precision (% RSD) 4.2 3.2 3.6 3.8 4.4 % Recovery 88 79 94 88 89 12 Application Notes

LC-MS/MS method for the determination of enalapril and enalaprilat from human plasma using SOLA enalapril, enalaprilat, benazepril (IS) SOLA SPE protocol Product: SOLA 1mg/2mL 96 well plate p/n 639-1 Matrix: human plasma Condition: 1mL methanol Equilibrate: 1mL water Load: 2µL of spiked human plasma containing internal standard Wash: 2µL water +.1% formic acid Elute: 2 x 2μL methanol + 2% ammonia Dry: under nitrogen Reconstitute: 2μL 9:1 (v/v) water:methanol HPLC conditions Instrumentation: Column: Mobile phase A: Mobile phase B: Thermo Scientific HPLC Thermo Scientific Hypersil GOLD 1.9μm, 5 x 2.1mm p/n 252-5213 water +.1% formic acid acetonitrile +.1% formic acid Gradient: t/min %A %B. 9 1 1. 1 Flow rate:.6ml/min Column temperature: 7 C Injection volume: 2.5µL Compound % Recovery Precision (%RSD) Accuracy (%difference) 1 MS conditions Enalapril 81 6.6-1.5 Enalaprilat 85 6.6-7.3 Instrumentation: Thermo Scientific TSQ Vantage Ionization conditions: HESI Polarity: positive Spray voltage: 3V Vaporizer temp: 317 C Sheath gas pressure: 52psi Ion sweep pressure: psi Aux gas pressure: 43psi Capillary temp: 37 C Declustering voltage: V Collision pressure: 1.5 Cycle time (s):.2 Q1 (FWHM):.7 Q3 (FWHM):.7 Compound Enalapril Enalaprilat Benazepril (IS) Parent (m/z) 377.3 349.2 425.3 Products (m/z) 234.2 26.2 351.2 Collision energy (ev) 16 17 19 S-lens 85 8 93 Relative Abundance 75 5 25 Enalapril Relative Abundance.2.4.6.8 1. 1.2 1.4 1.6 1.8 2. 1 75 5 25 Enalaprilat.2.4.6.8 1. 1.2 1.4 1.6 1.8 2. Application Notes 13

Separation of bases and neutrals from human plasma and urine using SOLA CX procainamide, propranolol, amitriptyline, hydrocortisone, corticosterone, progesterone (IS) SOLA CX SPE protocol Product: SOLA CX 1mg/mL cartridge p/n 619-2 Matrix: human plasma and urine Condition: 1µL methanol Equilibrate: 1µL water Load: 35µL sample Wash: 35µL water + 2% formic acid Elute 1: 35µL methanol Elute 2: 35µL methanol + 5% ammonia dilute or dry and reconstitute as appropriate HPLC conditions Instrumentation: Column: Mobile phase A: Mobile phase B: Thermo Scientific HPLC Thermo Scientific Accucore RP-MS 2.6μm, 5 x 3mm p/n 17626-533 2mM ammonium acetate acetonitrile Gradient: t/min %A %B. 95 5.5 95 5 5. 5 95 mau 2 15 1 5-5 1 1 2 3 4 5 6 Neutral standard (top trace), Basic standard (bottom trace) showing compounds 2 and 5 co-eluting mau 8 7 6 5 1 4 3 2 1-1 -2-3 -4-5 1 2 Bases extraction 2 5 2 6 3 3 4 5 6 3 4 4 4 Flow rate:.8ml/min Column temperature: 25 C Injection volume: 1μL Detector wavelength: 254nm Pure standard Urine Compound % Recovery Precision (% RSD) 1. Procainamide 91.6 2.3 2. Propranolol 12.3 3.4 3. Amitryptyline 95.5 2.8 4. Progesterone Internal Standard 5. Hydrocortisone 96.7 2.7 6. Corticosterone 95.9 2.9 Compound % Recovery Precision (% RSD) 1. Procainamide 87.3 1.7 2. Propranolol 94.2 2.9 3. Amitryptyline 96.9 1.8 4. Progesterone Internal Standard 5. Hydrocortisone 98.5 1.3 6. Corticosterone 98.9 1.1 14 Application Notes mau 1 8 6 4 2-2 -4-6 -8-1 -12-14 -16 Neutral extraction 1 2 3 4 5 6 5 6 4 Plasma Compound % Recovery Precision (% RSD) 1. Procainamide 98.3 11.8 2. Propranolol 97.6 3.7 3. Amitryptyline 95.3 5.2 4. Progesterone Internal Standard 5. Hydrocortisone 91.4 4.6 6. Corticosterone 95.8 6.4

LC-MS/MS method for the determination of HCTZ and losartan from human plasma using SOLA CX HCTZ, losartan, furosemide (IS) SOLA CX SPE protocol Product: SOLA CX 1mg/mL cartridge p/n 619-2 Matrix: human plasma Condition: 1mL methanol Equilibrate: 1mL water Load: 1µL of spiked human plasma containing internal standard Wash: 2µL water +.1% formic acid Elute: 2µL acetonitrile + 3% ammonia Dry: under nitrogen Reconstitute 1µL 8:2 (v/v) water:acetonitrile HPLC conditions Instrumentation: Column: Mobile phase A: Mobile phase B: Thermo Scientific HPLC Thermo Scientific Accucore aq, 2.6 µm, 5 x 2.1mm p/n 17326-5213 water +.1% formic acid acetonitrile +.1% formic acid Gradient: t/min %A %B. 8 2 2. 3 7 Flow rate:.4ml/min Column temperature: 4 C Injection volume: 2.5µL % Recovery Precision (% RSD) Accuracy (% difference) 1 Low QC High QC Low QC High QC Losartan 65.8 6.1 4.3 11.3 11.6 HCTZ 86.4 3.3 1.6 7.6.5 MS conditions Relative Abundance 75 5 25 Instrumentation: Thermo Scientific TSQ Vantage Ionization conditions: HESI Polarity: + losartan / - HCTZ and furosemide Spray voltage: 3V Vaporizer temp: 3 C Sheath gas pressure: 6psi Ion sweep pressure: psi Aux gas pressure: 3psi Capillary temp: 3 C Declustering voltage: V Collision pressure: 1.5 Cycle time (s):.5 Q1 (FWHM):.7 Q3 (FWHM):.7 Losartan Relative Abundance.2.4.6.8 1. 1.2 1.4 1.6 1.8 2. 2.2 2.4 1 75 5 25.2.4.6.8 1. 1.2 1.4 1.6 1.8 2. HCTZ Compound HCTZ Losartan Furosemide (IS) Parent (m/z) 295.9 423.2 329.1 Products (m/z) 25. 269. 18. 27. 25. 385. Collision energy (ev) 24 2 35 2 22 16 S-lens 98 98 91 91 14 14 Application Notes 15

UV method for the determination of tricyclic antidepressants from human plasma using SOLA CX tricyclic antidepressants SOLA CX SPE protocol Product: SOLA CX 1mg/mL cartridge p/n 619-2 Matrix: human plasma Condition: 5µL methanol Equilibrate: 5µL water Load: 45µL 1:2 plasma + 1mM PBS buffer (ph 6.) Wash 1: 5µL water +.1% formic acid Wash 2: 5µL methanol +.1% formic acid Elute: 5µL acetonitrile + 5% ammonium hydroxide Dry: under nitrogen do not apply heat Reconstitute: 15µL 8:2 (v/v) water:acetonitrile HPLC conditions Instrumentation: Thermo Scientific HPLC Column: Thermo Scientific Hypersil GOLD 3μm, 15 x 2.1mm p/n 253-15213 Mobile phase: 7:3 (v/v) water +.1% formic acid /acetonitrile +.1% formic acid Run time: 7.5 minutes Flow rate:.4ml/min Column temperature: 3 C Injection volume: 1μL Detector wavelength: 254 nm mau 14 12 1 8 6 4 2-2 -4.5 1. 1.5 2. 2.5 3. 3.5 4. 4.5 5. 5.5 6. 6.5 7. 7.5 8. Compound Doxepin Imipramine Amitriptyline Precision (%RSD) Trimipramine (IS) 5 4.8 4 5.1 % Recovery 78.9 73.4 74.3 69.7 16 Application Notes

LC-MS/MS method for the determination of capecitabine from human plasma using SOLA capecitabine SOLA SPE protocol Product: SOLA 1mg/mL cartridge p/n 619-1 Matrix: human plasma Condition: 5μL methanol Equilibrate: 5μL water Load: 2μL spiked plasma Wash: 2μL 8:2 (v/v) water:methanol Elute: 25μL methanol Dry: under nitrogen Reconstitute: 2μL water HPLC conditions Instrumentation: Column: Mobile phase A: Mobile phase B: Thermo Scientific HPLC Thermo Scientific Accucore PFP 2.6μm, 3 x 2.1mm p/n 17426-3213 water acetonitrile Gradient: t/min % A %B. 1 5. 1 Flow rate: 1.mL/min Column temperature: 4 C Injection volume: 1μL MS conditions Compound Instrumentation: Thermo Scientific TSQ Vantage Ionization conditions: HESI Polarity: Negative Spray voltage: 25V Vaporizer temp: 35 C Sheath gas pressure: 75psi Ion sweep pressure:.5psi Aux gas pressure: 45psi Capillary temp: 3 C Declustering voltage: V Collision pressure: 1.5 Cycle time (s):.5 Q1 (FWHM):.7 Q3 (FWHM):.7 Capecitabine Precision (%RSD) 2.3 % Recovery 73.2 Relative Abundance 1 9 8 7 6 5 4 3 2 1..5 1. 1.5 2. 2.5 3. 3.5 4. 4.5 5. 5.5 6. Capecitabine Compound Capecitabine Capecitabine-D8 Parent (m/z) 358.3 366. Products (m/z) 154.2 153.7 Collision energy (ev) 21 21 S-lens 94 13 Application Notes 17

Summary Compared to conventional SPE loose-packed products, SOLA products deliver: Significantly increased reproducibility More consistent and higher recoveries High levels of extract cleanliness Reduced solvent requirements Increased sensitivity Greater sample throughput In today s demanding laboratory environment, where reproducibility, certainty of results and cost saving are fundamental requirements, SOLA products are an indispensible tool to provide confidence and first-time/every-time success in the analytical process. Conventional SPE is no longer an option. Join the revolution with SOLA products. Product information: SOLA products are available in 1mg/mL cartridge and 1mg/2mL 96 well plate formats. SOLA SPE Cartridges Description Bed weight Column volume (ml) Cat No. Quantity SOLA 1mg 1mL 619-1 1 SOLA CX 1mg 1mL 619-2 1 SOLA AX 1mg 1mL 619-3 1 SOLA 96 Well Plates Description Bed weight Column volume (ml) Cat No. Quantity SOLA 1mg 2mL 639-1 1 SOLA CX 1mg 2mL 639-2 1 SOLA AX 1mg 2mL 639-3 1 For more information on method development and applications visit www.thermoscientific.com/sola-spe 18 Technical Guide

www.thermoscientific.com/sola-spe Our unmatched portfolio and experience in applications and method development will guide you through any challenge, on any instrument. Discover the most comprehensive array of chromatography consumables and environmental sampling products available. Reagents and Standards GC Columns and Accessories HPLC and LC-MS Environmental Sampling Vials and Closures Sample Preparation Chromatography Resource Center Search our database of thousands of applications at www.thermoscientific.com/chromatography

Resources for Chromatographers Thermo Scientific HyperSep Columns Application Notebook Our new SPE Application Notebook includes over 15 application notes focused on Pharmaceutical/Biotech, Environmental, Food Safety and Forensic solutions. Visit www.thermoscientific.com/spe Chromatography Resource Center Our web-based resource center provides technical support, applications, technical tips and literature to help move your separations forward. Visit www.thermoscientific.com/chromatography 211 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. USA and Canada +1 8 332 3331 France +33 ()1 6 92 48 34 Germany +49 () 2423 9431 2 or 21 United Kingdom +44 ()1928 53411 Japan +81 3 5826 1615 China +86 21 68654588 +86 1 84193588 +86 2 83145199 8 81 5118 India +91 22 6742 9494 Australia 1 3 735 292 (free call domestic) New Zealand 8 933 966 (free call domestic) All Other Enquiries +44 () 1928 534 5 Technical Support North America +1 8 332 3331 Outside North America +44 () 1928 534 44 BRCCSSOLA1111