TECHNICAL SPECIFICATION TYPE ATESO ALFA



Similar documents
Frequently Asked Questions. Air Top Diesel Heaters. 2000STC, Evo 40 & Evo 55

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Thermo Top - Troubleshooting Tree

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

Diesel Generating Set

HEAVY DUTY STORAGE GAS

Luft-Heizgeräte 03/2003. Workshop Manual. Air Heaters. Air Top 2000 ST. Type Air Top 2000 ST B (petrol) Type Air Top 2000 ST D (diesel)

Thermo 90 S Thermo 90 S-ADR. Thermo 90 ST Thermo 90 ST-ADR. Water heaters. Workshop manual. (Transport of hazardous goods)

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Luft-Heizgeräte 03/2003. Workshop Manual. Water heaters. Thermo Top V. Type Thermo Top V (Petrol) Type Thermo Top V (Diesel)

Thermo 230 Thermo 300 Thermo 350 with control unit 1572 model.30 and up

Air conditioning, electrical testing

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Troubleshooting and Repair Instructions. The troubleshooting and repair instructions are applicable to the following unit versions only

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Fossil fuel heating equipment

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

Air Top 2000 ST D (Diesel) Air Top 2000 ST B (Gasoline)

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

Oil / Air Cooling Units for mechanical engineering and mobile hydraulics

Contact Details. Please note that some of the contact details on this PDF document may not be current.

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS ELECTRIC HEATING UNITS MODEL: ETA / EKI

HEATER, AIR CONDITIONING AND VENTILATION

Oil - kerosene burners

HYDRONIC D5S/SC DIAGNOSTIC AND REPAIR MANUAL

MH 3M & 4M. High pressure washers with hot benefits

FLEXIT S4 R S6 R S7 R

ECOCIAT. Domestic hot water heat recovery unit

ONE STAGE LIGHT OIL AND KEROSENE BURNERS

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS Ex t IIIC T Da, Da/Db, Db IP 66

Technical Specification. Generating Set with Waukesha engine burning natural gas

Electric Coolant Pumps. Always at the Correct Temperature

94210E L7 X W. User Manual. Air Handling Unit Loft Models with water-based heating

Air Top 3500/ Circuit Diagrams

Electric Flow Boiler

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

Transporter Current Flow Diagram No. 80 / 1

CONTOIL DFM 8EDM. Table of contents. Mounting and operating instructions

Air Top 3500 ST. Air Top 5000 ST. Workshop manual. Air heaters

Thermo 90 S B (Gasoline) Thermo 90 S D (Diesel) Thermo 90 ST B (Gasoline) Thermo 90 ST D (Diesel)

E - THEORY/OPERATION

Transformer oil cooler ALFA A02

HERZ-Thermal Actuators

O-I DUBI PLANT FANS Quotation Spec Data & Specifications

PLANAR-2D-12/24. Contents


Oil, Gas and Dual Fuel Burners

STERILIZERS, LABORATORY DRYING OVENS

HeatSource HS1800 Heater

GeniSys 12V. Model Description / Applications. Advanced 12 Vdc Burner Control

Annex-A TECHNICAL SPECIFICATION

A/C-HEATER SYSTEM - AUTOMATIC

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

Emission Control Systems Warranties

Diesel Engine Driven Generators Page 1 of 6

Material test chamber with mechanical convection


AVR Pellet Control Board Installation/Service Instructions

MovinCool Office Pro Series. The Portable Spot Cooling Solution

LAND ROVER FUEL INJECTION SYSTEMS

Powertrain DTC (P000-P0999) for EOBD Vehicles (Directive 98/69/EC of the European Parliament)

C18 ACERT Fire Pump Tier bkw/ rpm

SERVICE INSTRUCTIONS

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

The Yachtmans Choice...

Solid Oxide Fuel Cell Gas Turbine Hybrid Power Plant. M. Henke, C. Willich, M. Steilen, J. Kallo, K. A. Friedrich

CHAPTER 7 THE SECOND LAW OF THERMODYNAMICS. Blank

Weiss Mobile Air Conditioning Systems

- mark gas burners Cuenotherm NC.4 - NC.6 - NC kW.

Electric Rotary Actuator - On/Off or programmable control actuator

Incubator with mechanical convection

AIR CONDITIONING LIFE EXTENDER ACX10 FIELD INSTALLATION AND PERFORMANCE EVALUATION

Split Controller. User Manual SM-SS-F 2009/01/04

UDSA - UDSBD unit heater

Groupes Marins Infos et tarifs

OIL BURNERS LOW PRESSURE, DESIGNED FOR COMBUSTION OF LIGHT FUEL OIL, MEDIUM FUEL OIL-1P, WASTE OILS.

Power kva 17,4 18,9 Power kw 13,9 15,1 Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 0,8

Electrical Systems - IQAN Digital Control System. IQAN Control System Components

Failure code manual. content

SPECIALIST RENTAL PROVIDER HEATING & HOT WATER PACKAGES


Flex separation systems, S-separators

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

94122E FLEXIT L4 X/TT L7 X/TT. User Manual. Air Handling Unit Loft Models with Heat Recovery

PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

PANASONIC TROUBLE SHOOTING GUIDE

Specifications for Volkswagen Industrial Engine

POLYCITY. Technical measures and experiences at a 6 MW cogeneration plant with wood chip furnace POLYCITY

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

14. Troubleshooting Guide

Commercial Gas Furnace Upflow

ELECTRIC CENTRAL HEATING FLOW BOILER

Transcription:

Page: 1 of 5 TECHNICAL SPECIFICATION TYPE ATESO ALFA 1. GENERAL 1.1. Make (trade name of manufacturer): BRANO a.s. 1.2. Type and general commercial description(s): ATESO ALFA 1.2.1 1.2.2. Variants: Versions: D2 (diesel 2 kw) ** 12 and 24 V * 1.3. Location of that marking: At the label (usually) 1.4. Category of heater: Independent combustion heater 1.5. Name and address of manufacturer: BRANO a.s. Opavska 1000 747 41 Hradec nad Moravicí Czech Republic Regisetred in Companies Register at regional Court in Ostrava, Section B, Insert No.387 Reg.No.: 45193363 VAT Reg.No.: CZ45193363 1.6 Address (es) of assembly plant (s): BRANO a.s. SBU Commercial Vehicles Na Racanech 100 514 01 JILEMNICE Czech Republic ** D2 designation means: D... fuel is diesel, 2... max heating capacity is 2kW * To operate on 24V it is necessary to change the parameter tables in the control unit by diagnostic software

Page: 2 of 5 2. GENERAL CONSTRUCTION CHARACTERISTICS OF THE HEATER 2.1. 2.2 2.3 PRODUCT DESCRIPTION TECHNICAL SPECIFICATION SERVIS BOOK (http://breezeservice.webnode.cz/dokumenty/) 03-9940.186

Page: 3 of 5 2. GENERAL CONSTRUCTION CHARACTERISTICS OF THE HEATER 2.1 PRODUCT DESCRIPTION The heater is designed to heat the interior compartments of motor vehicles, box-van trucks, cabs of heavy machinery, caravans, immobile dwelling cells, yachts etc., either in recirculating operation only or with a possibility to intake the air from the outside area. It is not intended for installation into vehicles used for transport of hazardous freight. Heater ATESO ALFA is a heating device using the heat generated by burning diesel oil for heating of air, while its heating capacity can be regulated continuously. Apart from the heater itself the set comprises the following components allowing its right function: an electric pump, a cable harness, an intake silencer, an exhaust and parts necessary for installation in the vehicle. There is one variant of the heater - D2. D2 designation means: D... fuel is diesel, 2... max heating capacity is 2kW. There are two versions of the heater for voltage 12V and 24V. Heaters supplied from the factory are designed for 12V. To operate on 24V it is necessary to change the parameter tables in the control unit by diagnostic software. Main parts of the heater are: an aluminium heat exchanger, a combustion chamber, an electric motor with fans for heated air and combustion air, a housing, a rotation sensor, a flame indicator, an overheat thermostat, a glow plug and a control device with an output air sensor. Timer or manual control is possible to use for control of the heater. 2.2 TECHNICAL SPECIFICATION Heating capacity [W] 900-1800 Rated voltage [V] 12/24* Operating voltage range - 12V [V] 10,5 15 Operating voltage range - 24V [V] 21-30 Power consumption on startup [W] 110 10% Power consumption - in operation [W] 25 10% Fuel Diesel EN 590, light fuel oil, BIO-oil ČSN 65 6509

Page: 4 of 5 Fuel consumption [l/h] 0,10 0,22 Capacity regulation Continuously adjustable (within the ten steps) from min. to max Adjustable temperature range [ C] 1 30 El. motor speed max [RPM] 4800 50 El. motor speed min [RPM] 2800 50 Regulated speed [RPM] 1980 50 Temperature at purging [ C] 80 5 The temperature of heating air to open the fuse overheating [ C] 120 150 Temperature of the flame sensor at maximum capacity [ C] 200 300 Frequency of the pump at maximum capacity [Hz] 3,0 0,1 Hot air output (at backpressure 0Pa) [m 3 /hod] 85 Pressure in the fuel tank max [kpa] 10 Ambient operating temperature heating [ C] -40 to +65 Operating temperature range heating [ C] -40 to +40 Weight of the heater [kg] 2,2 Weight of the complete set [kg] 2,8 The electric installation conforms ČSN 30 4002 Electromagnetic compatibility corresponds EHK 010.04 Environmental resistance conforms to - el. pump and exhaust - other parts ČSN EN ISO 9227 NSS U24 U23

Page: 5 of 5 2.3 SERVIS BOOK (http://breezeservice.webnode.cz/dokumenty/) 03-9940.186 Service book is not part of this document, it can be found on the website: http://breezeservice.webnode.cz/dokumenty/