KNX Panasonic Air Conditioners



Similar documents
IntesisBox KNX Modbus TCP master

IntesisBox KNX LG Air Conditioning

IntesisBox KNX Modbus RTU master

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

IntesisBox KNX Mitsubishi Heavy Industries AC

IntesisBox KNX - LON

IntesisBox Modbus Server SAMSUNG Air Conditioners

IntesisBox Modbus Server Fidelio IP

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

Modbus Server SAMSUNG Air Conditioners

IntesisBox Modbus Server - Mitsubishi Electric G50

IntesisBox ASCII Server - LON

Inwall Room Temperature Unit

Electronic Control Devices The European Product Catalogue 2007

LGAC-KNX PROGRAMMING MANUAL. Integrations V1.0 TECHNICAL SUPPORT. Tel (+34)

IntesisBox DK-RC-ENO-1iC. EnOcean Interface for DAIKIN Air Conditioners Compatible with SKY and VRV lines

Waveguide Access Point WGA631. Product Guide

TX OPEN RS232/485 module

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

OZS Web server. For LPB/BSB plants

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Product Manual. ABB i-bus KNX Data Logging Unit BDB/S 1.1. Intelligent Installation Systems ABB

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

Digital input modules

IntesisBox DK-RC-KNX-1

Inwall 4 Input / 4 Output Module

Electronic Control Devices The European Product Catalogue 2007

Rack mounted telephone- and leased line modem for industrial applications

Telephone- and leased line modem for industrial applications TD-36

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

KNX Interface. User Manual PM00A00IRI

How To Use A Power Supply On A Powerline 2.2 (Ai)

Product and functional description

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

QSE-CI-NWK-E Control Interface

PCS0100en Persy Control Services B.V. Netherlands

Energy Communication Unit (ECU)

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Unidirectional Transmitter/ Receiver Units Introduction

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Installation Guide. Wireless N Access Point EAP110/EAP120/EAP220

ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

User manual Compact Web PLC WP240 series IEC-line

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Foxboro Evo Process Automation System

Series LC6D/LC6C. To power supply PLC. LC6C dedicated teaching box P.971. Options P.973

RRV934. Multi-controller. Synco living

User Manual. EtherUSB

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

ZC-24DO CANopen I/O Module: 24 Digital Outputs

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

HMI display Installation Guide

FX07 Field Controller

ABB i-bus KNX Fan Coil Controller FC/S 1.1

USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

NX safety stand-alone

AXIS T81B22 DC 30W Midspan

1 Serial RS232 to Ethernet Adapter Installation Guide

Panasonic/Sanyo A/C Interface Modbus RTU Installation Instructions

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

OZW V2.0. Web server. Synco TM, Synco TM living

8-Port PoE Network Switch

Loop-IP6702 TDMoEthernet

HCR3.2/.. Chipcard reader HOTEL SOLUTION

PXM20-E. Operator unit DESIGO PX

HARTING econ 3000 Introduction and features

Application/Connection Examples

EDI Distributor Control Interface Wiring and Setup Instructions

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

B.IQ push button 3-5gang with room thermostat and display V2, flush-mounted x, x, x

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

Communication Capabilities via a Touch Screen or a Web Browser Further Expand Air-Conditioning Control Possibilities.

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Technical Manual MDT Rain sensor

ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide

TrueAlarm Fire Alarm Systems

Modbus RTU (RS-485) TCP/IP (Ethernet)

FX07 Field Controller

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Remote Monitoring and REC 501 Control Unit Product Guide

Megapixall Security Tools & Accessories

VOICE RECORDING SYSTEM ISDN PRI / BRI

HWg-STE HWg-STE PoE MANUAL

Long Reach PoE over Coaxial Extender Kit

HARTING mcon 1000 Introduction and features

MultiVOIP FX FXS-Only SIP Gateways

Transcription:

IntesisBox KNX Panasonic Air Conditioners Gateway for Panasonic ECOi and PACi system integration into KNX networks Up to 30 Outdoor units Up to 64 Indoor units PA-AC-KNX-64/128 EIA485 U1U2 line U1U2 line LinkBoxEIB Software EIA232 or Ethertnet IP Only needed for configuration Up to 30 Outdoor units Up to 64 Indoor units IntesisBox is a KNX device, capable of monitoring and controlling Panasonic ECOi and PACi indoor units connected to a Panasonic communication adaptor 1. Up to 64 indoor units and 30 outdoor units can be integrated within a single channel. If you use both channels, up to 128 indoor units can be integrated. IntesisBox simulates a KNX device and acts in the KNX system as another KNX device. The IntesisBox's KNX EIB interface connects directly to the EIB bus and is opto-isolated from the rest of the internal electronics. IntesisBox KNX series are configured using LinkBoxEIB, a software tool for Windows which is supplied along with the purchase of IntesisBox with no additional cost. With the standard installation of LinkBoxEIB, a Demo project for integration of ECOi and PACi systems is also installed. Using this demo project makes the engineering needed for this integration easy and quick, almost plug&play. There are two models of IntesisBox KNX Panasonic: Model supporting up to 64 indoor units. Ref: PA-AC-KNX-64 Model supporting up to 128 indoor units. Ref: PA-AC-KNX-128 1 CZ-CFUN2 is an accessory provided by Panasonic and should be acquired separately. TRADEMARKS: All trademarks and tradenames used in this document are acknowledged to be the copyright of their respective holders. 1 / 6

1. IntesisBox capacity Element Capacity Notes Max Group Address 4000 Total number of KNX Groups that can be used in IntesisBox. 2. KNX Interface KNX/EIB interface Bus coupler parameters Interactivity with KNX/EIB system Points parameters per point Internal KNX TP1 (EIB) opto-isolated bus coupler unit for direct connection to EIB bus. Connector: 2 poles plug-in screw terminal block. Physical address. The points can be read from KNX. Configurable individually per point. The points can be written from KNX. Configurable individually per point. A write request can be sent to KNX following a change in the point s value. Configurable individually per point. The point value can be updated with a read request sent to KNX when IntesisBox starts up or after bus reset detection. Configurable individually per point. Multiple KNX group addresses can actuate on the same IntesisBox s point. Generic fields. Point description. Useful to identify the point s location into the Modbus system. Active (Yes/No). Useful to deactivate points maintaining the configuration for later use. KNX/EIB related fields. Group address (in format P/I/S or P/S). Is the sending group address. Listening addresses (in format P/I/S or P/S separated by comma). The gateway will listen for write requests for these listening addresses, when received then it will act as if they were for the main group address defined. This is very useful to translate actions to the Panasonic system coming from different KNX commands, for example from an individual start/stop button and also from a general start/stop button. R. Specifies if the point accepts read requests from KNX. W. Specifies if the point accepts write requests from KNX. T. Specifies if a write request will be sent to KNX when the point s value changes. U. Specifies if the point s value must be updated with a read request sent to KNX when the gateway starts up or after a bus reset detection. If U is specified in this field, the read request will be of the main group address. If U2 is specified in this field, the read request will be of the first listening address defined. EIS (Datapoint). See EIS supported below. KNX EIS (Datapoints) supported The configuration of this part must be done in co-operation with the engineer in charge of setting up the whole KNX system. Some of the data to introduce in this part must be supplied by the KNX engineer. Switching (1 bit) Counter (8 bits) Counter (16 bits) Float (16 bits) DPT 1.100 (1 bit) DPT 20.105 (8bits) TRADEMARKS: All trademarks and tradenames used in this document are acknowledged to be the copyright of their respective holders. 2 / 6

3. Panasonic Interface Property Datapoint Type Flags W R T U On/Off 1 Switching (1bit) W R T Mode::Cool EIS 14 (8bit) W R T DPT 20.105 (8bit) W R T DPT 1.100 (1bit) W R T Start/Stop AC Unit 0 OFF, 1 ON Description 0 Cool, 1 Heat, 2 Fan, 3 Dry, 4 Auto 0 Auto, 1 Heat, 3 Cool, 9 Fan, 14 Dry 0 Cool, 1 Heat Mode::Heat Mode::Dry Mode::Fan Mode::Auto Only one of these objects will be set / read to 1 at the same time (all objects will be updated on bus upon a Mode change) Set Temperature EIS 5 Float (2byte) W R T Fan Speed 14 Counter (8bit) W R T FanSpeed::Auto FanSpeed::Low FanSpeed::Mid FanSpeed::High Temperature Set Point (only integer numbers allowed) -15..60 ºC AC Fan Speed 0 Auto, 1 Low, 2 Mid, 3 High Only one of these objects will be set / read to 1 at the same time (all objects will be updated on bus upon a FanSpeed change) Air Direction 14 Counter (8bit) W R T Filter Sign 1 Switching (1bit) R T Filter Sign clear 1 Switching (1bit) W T Error Code 10 Counter (16bit) R T Room Temperature EIS 5 Float (2byte) R T IU Exist 1 Switching (1bit) R T RC Prohibition OnOff 1 Switching (1bit) W R T RC Prohibition Mode 1 Switching (1bit) W R T RC Prohibition SetPoint 1 Switching (1bit) W R T RC Prohibition FanSpeed 1 Switching (1bit) W R T RC Prohibition AirDirection 1 Switching (1bit) W R T AC Air Direction 0 Horizontal. 4 Vertical; 5 Swing Filter status 0 No alarm, 1 Filter sign present Filter Alarm Reset 1 Filter sign reset Error Code More info in User Manual Room Temperature (only integer numbers) Read: -35ºC to 92ºC Indoor Unit present in the System 0 Not present, 1 Present TRADEMARKS: All trademarks and tradenames used in this document are acknowledged to be the copyright of their respective holders. 3 / 6

4. tool LinkBoxEIB Visual engineering tool, ease of use, for IntesisBox s configuration and monitoring compatible with Microsoft Windows operating systems, supplied with the purchase of IntesisBox with no additional cost. Multi-window tool allowing to monitor simultaneously the communication activity with both protocols (systems) and the real time values for all the points allowing to modify any value (very useful for test purposes), console window showing debug and operation status messages, and configuration windows to configure all the IntesisBox s parameters and points. Points' configuration in plain text files (tab separated) for easy and quick configuration using Microsoft Excel (very useful in projects with a lot of points). Allows configuring the IntesisBox s parameters and points while in off-line, this is, not connected to the gateway. You can configure/modify the IntesisBox's parameters comfortably in the office and later download the configuration to the IntesisBox in the field. Connection to the IntesisBox for configuration downloading and signals monitoring using a serial COM port of the PC (serial cable also supplied). Allows configuring all the external protocols available for IntesisBox KNX series. Upgrades for this software tool available free of charge whenever a new protocol is added to the IntesisBox KNX series. Multi-project tool allowing to have in the engineer s PC the configuration for all the sites where different IntesisBox KNX series gateways have been installed. Multi-language tool, all the language-dependent strings are in a plain text file (tab separated) for easy modification or addition of new languages. A list of system commands is available to send to the IntesisBox, for debugging and adjust purposes (Reset, Date/time consultation/adjust, Firmware version request ). TRADEMARKS: All trademarks and tradenames used in this document are acknowledged to be the copyright of their respective holders. 4 / 6

5. Mechanical & Electrical characteristics Enclosure Plastic, type PC (UL 94 V-0). Dimensions: 107mm x 105mm x 58mm. Color Light Grey / RAL 7035. 9 to 30Vdc +/-10%, Max.: 125mA. 24Vac +/-10% 50-60Hz, Max.: 127mA Power Must use a NEC Class 2 or Limited Power Source (LPS) and SELV rated power supply. Terminal wiring (for power supply and low-voltage signals) Mounting KNX port Plug-in terminal block for power connection (2 poles). Per terminal: solid wires or stranded wires (twisted or with ferrule) 1 core: 0.5mm 2 2.5mm 2 2 cores: 0.5mm 2 1.5mm 2 3 cores: not permitted Wall. DIN rail EN60715 TH35. 1 x KNX TP1 (EIB) opto-isolated (Plug-in screw terminal block 2 poles). Ethernet port 1 x Ethernet 10Base-T (RJ45) port 1 x EIA485 Plug-in screw terminal block (2 poles). 1 x Power. LED indicators 2 x KNX port activity (Tx, Rx) 2 x Ethernet port (LNK, ACT) Console port EIA232. (DB9 female connector, DCE). SELV Via console port 2. Firmware Allows upgrades via console port. Operational temperature 0 C to 40 C Operational humidity 5 to 95%, non condensing Protection IP20 (IEC60529). RoHS conformity Compliant with RoHS directive (2002/95/CE). CE conformity to EMC directive (2004/108/EC) and Low-voltage directive (2006/95/EC) Norms and standards EN 61000-6-2 ; EN 61000-6-3 ; EN 60950-1 ; EN 50491-3 Power Ethernet RJ45 and monitoring KNX TP-1 (EIB) - + CMN 24Vac 9-30Vdc Max.125 ma 24Vac Max.127mA 50-60Hz - + ETH IntesisBox www.intesis.com KNX TP-1 (EIB) PC Console Ethernet RJ45 Not supplied Only needed for configuration or monitoring Panasonic EIA485 Console wire 1.8 m long. DB9 Female - DB9 Male standard. It is supplied. LinkBoxEIB Only needed for configuration 2 Standard cable DB9male-DB9female 1,8 meters long is supplied with the device for connection to a PC COM port for configuring and monitoring the device. The configuration software, compatible with Windows operating systems, is also supplied. TRADEMARKS: All trademarks and tradenames used in this document are acknowledged to be the copyright of their respective holders. 5 / 6

6. Dimensions External dimensions Power Ethernet port port KNX port 58 mm Console port 107 mm 105 mm Free space recommended in the install location of the device, with spacing enough for external connections. 100 mm 115 mm 130 mm TRADEMARKS: All trademarks and tradenames used in this document are acknowledged to be the copyright of their respective holders. 6 / 6